- All
- Favorite
- Popular
- Most rated
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Application | Field-Portable Soil & Environmental Analysis |
| Elemental Range | Mg to U |
| Detection Limit | 1 ppm (typical for heavy metals in soil matrices) |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | RSD ≤ 0.1% (for major elements under optimized conditions) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN600 |
| Application | Handheld/Portable |
| Element Range | Na–U |
| Detection Limit | 1 ppm |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Regulatory Compliance | RoHS II (2011/65/EU), CPSIA 2008, EPA Method 6200, California Proposition 65, US Safe Drinking Water Act |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Application | Field-Portable Ore & Geochemical Analysis |
| Elemental Range | Mg–U |
| Detection Limit | 1 ppm (typical, matrix-dependent) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV at Mn Kα (5.9 keV) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CTX Portable Benchtop XRF Analyzer |
| Application Mode | Benchtop/Portable |
| Industry Type | General-Purpose |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability (RSD) | ≤0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | M4 TORNADO PLUS |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | C (Z=6) to Am (Z=95) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Compliance | CE, RoHS, IEC 61000-4 series |
| Safety | IEC 62471 (LED/X-ray emission), EN 61326-1 |
| Brand | COX Analytical Systems |
|---|---|
| Origin | Sweden |
| Model | Itrax XRF |
| Configuration | Benchtop/Floor-standing |
| Application Domain | Geological & Sediment Core Analysis |
| Elemental Range | Na (11) – U (92) |
| Detection Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | S1 TITAN |
| Application | Handheld/Portable |
| Industry Type | General-Purpose |
| Elemental Range | Mg–U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Element Range | Mg–U |
| Detection Limit | 1 ppm–99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ±0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| X-ray Tube | 50 kV microfocus tube |
| Form Factor | Handheld (1.23 kg) |
| Compliance | ASTM F963, RoHS, USP <232>/<233>, EPA Method 6200, ISO 12885, IEC 62321 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/Floor-Standing |
| Element Range | Mg–U |
| Detection Limit | 1 ppm |
| Quantitative Range | 0.0001–99.99 wt% |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability (RSD) | ≤0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Excitation | Dual X-ray Tube Option with Up to 6 Automatic Filter Positions |
| Optics | Polycapillary Focusing Lens |
| Sample Stage | Motorized X-Y-Z with Turbo Drive |
| Imaging Mode | Real-time Elemental Mapping “On-the-Fly” |
| Vacuum Capability | Integrated Vacuum Chamber |
| Quantification Method | Fundamental Parameters (FP) Algorithm without Standards |
| Compliance | Fully Compatible with ISO 17025, ASTM E1621, and USP <233> for Elemental Impurities |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Application | Handheld/Portable |
| Element Range | Mg–U |
| Concentration Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | 0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | S2 PICOFOX (TXRF) |
| Configuration | Benchtop |
| Application Scope | General-Purpose |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | Down to 2 pg |
| Quantification Range | ppb to 100% |
| Energy Resolution | <125 eV at Mn Kα (FWHM, 100 kcps), <135 eV typical |
| Repeatability | ≤0.1% RSD |
| Detector | Fourth-Generation XFlash® Silicon Drift Detector (SDD) with Peltier Cooling |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN 300 |
| Application | Handheld/Portable |
| Industry-Specific Type | Non-Ferrous & Alloy Metals |
| Elemental Range | Mg–U (High-Performance Configuration) / Ti–U (Standard Configuration) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD (for major elements under controlled conditions) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITA |
| Application | Handheld/Portable |
| Element Range | Na (11) – U (92) |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Weight | 1.5 kg |
| Compliance | API RP 578, ASTM E2857, ISO 17025 (when operated under accredited conditions), FDA 21 CFR Part 11–ready software configuration |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | S1 TITAN |
| Application | Handheld / Portable |
| Industry Type | General-Purpose |
| Elemental Range | Mg–U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| X-ray Tube | 50 kV |
| Weight | 1.23 kg |
| Display | Integrated Color Touchscreen |
| Key Technologies | SharpBeam® X-ray Geometry Optimization, SMART®Grade Timing Algorithm, X-Flash® SDD |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Application | Handheld/Portable |
| Elemental Range | Mg–U |
| Detection Limit | 1 ppm to 99.99% w/w |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ±0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| X-ray Tube | 50 kV microfocus |
| Weight | 1.23 kg |
| Compliance | ASTM F963, RoHS, EU Directive 2011/65/EU, California Proposition 65, TPCH, USP <232>/<233>, ISO 17025-aligned operation |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | CTX |
| Application | Handheld/Portable Elemental Analysis |
| Element Range | Mg–U (standard), Cl–U (optimized for cosmetics), Ti–U (heavy metals focus) |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Operating Temperature | −10 °C to +40 °C |
| Sample Forms | Solids, powders, liquids, pastes, creams, gels, tablets |
| Regulatory Compliance | ASTM E2857, ISO 12885, USP <232>/<233>, FDA 21 CFR Part 11 (software-enabled), GLP/GMP-ready audit trail |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability (RSD) | ≤0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Spot Size | Adjustable down to ~25 µm |
| Excitation Source | Rh anode microfocus X-ray tube |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PICOFOX |
| Configuration | Benchtop |
| Application Type | General Purpose |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | down to 2 pg |
| Quantification Range | sub-ppb to 100% |
| Energy Resolution | <125 eV at Mn Kα (low count rate), <135 eV at Mn Kα (high count rate, 100 kcps) |
| Repeatability | ≤0.1% RSD |
| Detector | Fourth-generation XFlash® Silicon Drift Detector (SDD) with Peltier cooling |
| Sample Volume | 1–50 µL (liquids/suspensions), ≤10 µg (powders) |
| Automation Options | 1-position or 25-position auto-samplers |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | TRACER 5g |
| Application | Handheld/Portable |
| Instrument Type | General-Purpose Research-Grade ED-XRF |
| Industry-Specific Use | Geoscience & Mineral Exploration |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% RSD |
| Detector | Silicon Drift Detector (SDD) with 1 µm Graphene Window |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil and Atmospheric Environmental Monitoring |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Compliance | ASTM D7213, ISO 18562-2, EPA Method 6200 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D8 ENDEAVOR |
| Instrument Type | High-Resolution X-ray Diffractometer |
| Configuration | Floor-Standing |
| Power Options | 1 kW (ECO) / 3 kW |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.01° |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | CTX |
| Form Factor | Portable Benchtop |
| Elemental Range | Mg–U (standard), Ti–U (optimized), Cl–U (liquid/powder mode) |
| Energy Resolution | 145 eV (at Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Operating Temperature | –10 °C to +40 °C |
| Safety Features | Dual Interlock System, Visual Status Indicators (Amber/Red LEDs), Sample Presence Sensor, Password Protection, Pre-Start Radiation Alert |
| Power Options | Rechargeable Li-ion battery or 110/220 VAC adapter |
| Compliance | Designed for IEC 61010-1, IEC 62471, and aligned with ALARA principles for radiation safety |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Handheld Portable |
| Element Range | Mg–U |
| Detection Limit | 1 ppm |
| Concentration Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector Type | Silicon Drift Detector (SDD) |
| Compliance | CE, RoHS, FCC Class B, IEC 61000-4-2/3/4/6 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | CRONO |
| Application | Portable/Field-Deployable |
| Element Range | Na–U |
| Excitation Source | 50 kV / 100 µA X-ray Tube |
| Spot Size | 2 mm Diameter |
| Scan Speed | 20 mm/s |
| Measurement Distance | 1 cm (non-contact) |
| Detector | Silicon Drift Detector (SDD) |
| Spatial Coverage | Up to 60 cm × 45 cm |
| Energy Resolution | ≤130 eV at Mn Kα |
| Repeatability (RSD) | ≤0.1% for major elements |
| Front-End Electronics | CUBE CMOS preamplifier + DANTE digital pulse processor |
| Software | CRONO Control & Mapping Suite with real-time spectral visualization, pixel-wise spectrum storage, and automated PDF reporting |
Show next