Refrigeration Equipment
Filter
Showing 511–540 of 1585 results
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | LX-09A |
| Instrument Type | Integrated |
| Cooling Method | Water-cooled |
| Temperature Control Range | 8–35 °C |
| Temperature Stability | ±1.0 °C |
| Refrigeration Capacity | 900 W @ 25 °C |
| Circulation Pump Pressure | 1.5 bar |
| Flow Rate | 4 L/min @ 1.5 bar |
| Reservoir Volume | 9 L |
| Operating Mode | Continuous |
| Refrigerant | R-134a |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 400 × 590 × 541 mm |
| Temperature Resolution | 0.1 °C |
| Total Power Consumption | 660 W |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | LXS-15 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-cooled |
| Temperature Control Range | 8–35 °C |
| Temperature Stability | ±1 °C |
| Refrigeration Capacity | 3000 W |
| Circulation Pump Pressure | 4 bar |
| Circulation Flow Rate | 12.1 L/min |
| Reservoir Volume | 6 L |
| Control System | PID-based LCD Microprocessor Controller |
| Refrigeration Technology | Hot Gas Bypass (Continuous Modulation, Non-Cycling) |
| Heat Exchanger Type | Plate-type |
| Refrigerant | Eco-friendly, Non-CFC/Non-HFC (Compliant with ISO 5149 & EN 378) |
| Pump | Imported Low-Noise Centrifugal Pump |
| Fluid Compatibility | Deionized or Distilled Water Only |
| Safety Features | Overpressure Relief Bypass, Dry-run Protection, High-Temperature Cut-off, Reservoir Level Sensor |
| Brand | LabS |
|---|---|
| Origin | Guangdong, China |
| Model | FL-0904A / FL-1105A |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–40 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 1600–2700 W |
| Circulating Pump Pressure | 1.0 bar |
| Circulating Pump Flow Rate | 42 L/min |
| Reservoir Volume | 8.5 L |
| Heat Exchanger Material | Stainless Steel |
| Compressor | Premium Industrial-Grade |
| Refrigerant Option | R134a or Eco-Friendly Alternative (Optional) |
| Noise Level | Low-Noise Operation |
| Control System | Microprocessor-Based Digital Controller |
| Dual-Circuit Capability | Internal + External Loop Support |
| Remote Control Interface | Optional 0–10 V or Dry Contact Input |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FD-1E-80 |
| Price | USD 7,050 (FOB Shanghai) |
| Condenser Temperature | ≤ −80 °C |
| Ultimate Vacuum | < 20 Pa |
| Ice Capacity | 4 kg/24 h |
| Condenser Dimensions | Φ200 × 200 mm |
| Chamber Material | Transparent Acrylic Bell Jar |
| Refrigeration System | Dual-Stage Cascade Compressor |
| Power Supply | 220 V, 50 Hz, 1300 W |
| Overall Dimensions | 492 × 540 × 800 mm |
| Sample Compatibility | T-manifold with up to 8× Ø24 mm glass vials or 24× standard culture tubes |
| Data Display | Digital LED panel for real-time condenser temperature and chamber pressure |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FD-1L (Stoppering Type) |
| Price | USD 5,300 (FOB Beijing) |
| Condenser Temperature | < −80 °C (empty) |
| Freeze-Drying Area | 0.08–0.12 m² (3 stainless steel trays, Ø200 mm) |
| Ultimate Vacuum | < 10 Pa (empty) |
| Total Power Consumption | 900 W (500 W lyophilizer + 400 W 2 L rotary vane pump) |
| Dimensions (W×D×H) | 400 × 550 × 650 mm |
| Input Power | 220 V ±10%, 50 Hz, 1000 W max |
| Display | LED digital readouts for condenser temperature and chamber pressure |
| Control Interface | Touch-sensitive membrane keypad |
| Gas Inlet | Motorized solenoid valve for nitrogen or inert gas backfilling |
| Chamber | Transparent acrylic bell jar with ambient-temperature drying |
| Construction | 304 stainless steel work surface and condenser housing |
| Refrigeration System | Imported hermetic dual-stage cascade compressor unit |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | H35 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | −5 to 35 °C |
| Cooling Capacity | 350 W (at 20 °C ambient) / 500 W (at 25 °C ambient) |
| Temperature Stability | ±0.3 °C |
| Circulation Pump Pressure | 1.0 bar |
| Circulation Flow Rate | 3.5 L/min |
| Reservoir Volume | 1.8 L |
| Operation Mode | Continuous |
| Control Technology | PID Digital Temperature Control + Hot Gas Bypass Compressor Modulation |
| Heat Exchanger | Plate-Type |
| Refrigerant | R134a (CFC-free, ozone-friendly) |
| Display | Backlit LCD |
| Brand | LabTech |
|---|---|
| Model | H35 |
| Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –5 to 35 °C |
| Temperature Stability | ±0.3 °C |
| Refrigeration Capacity | 350 W / 500 W |
| Circulation Pump Pressure | 1.0 bar |
| Flow Rate | 3.5 L/min |
| Reservoir Volume | 1.8 L |
| Operation Mode | Continuous |
| Control Technology | PID + Hot Gas Bypass |
| Heat Exchanger | Plate-Type |
| Refrigerant | R134a (CFC-free) |
| Power Consumption | Optimized for low-energy continuous operation |
| Compliance | Designed per IEC 61000-6-3 (EMC), IEC 61010-1 (Safety), and ISO 9001 manufacturing standards |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | H500 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Stability | ±0.2 °C |
| Design Architecture | Separated Refrigeration and Heat Dissipation Units |
| Low-Temperature Operation Capability | Functional at outdoor ambient temperatures down to −25 °C |
| Control Interface | Full-Color Touchscreen with Real-Time Multi-Parameter Display |
| Safety System | 13 Diagnostic Alarm Codes |
| Operational Flexibility | 12 Configurable System Parameter Sets |
| Hot Gas Bypass Technology | Integrated |
| PID Digital Temperature Control | Standard |
| Brand | LabTech |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LCW-4000 Series |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 8–35 °C |
| Refrigeration Capacity | 1.2–5.0 kW |
| Temperature Stability | ±0.2 °C |
| Circulation Pump Pressure | 4.0 bar |
| Circulation Flow Rate | 17.1 L/min |
| Reservoir Volume | 20–40 L |
| Operating Mode | Continuous Duty |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | –40 °C to +100 °C |
| Temperature Stability | ±0.05 °C (at setpoint, under stabilized conditions) |
| Bath Material | Seamless 304 Stainless Steel |
| Interface | RS485 for Remote Monitoring and Control |
| Safety Features | Dual High/Low Temperature Alarm, Low-Level Liquid Alarm |
| Circulation Mode | Switchable Internal/External Loop via Manual Knob |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SH150-3000 |
| Temperature Control Range | 8–35 °C |
| Cooling Capacity | 3000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Flow Rate | 12.1 L/min @ 4 bar |
| Reservoir Volume | 3.5 L |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | SMART Series |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 8–35 °C (Low-Temperature Models: −20 to 35 °C) |
| Refrigeration Capacity | 1000 W (@25 °C ambient) |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 3 bar (43.5 psi) |
| Flow Rate | 6.4 L/min |
| Reservoir Volume | ~5 L |
| Operating Mode | Continuous Duty (Hot Gas Bypass Control) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SMART Series |
| Instrument Type | Integrated Unit |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 8–35 °C |
| Cooling Capacity | 700–3000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 1.0–6.0 bar |
| Circulation Flow Rate | 3.5–12.1 L/min |
| Reservoir Volume | 1.8–3.5 L |
| Operation Mode | Continuous |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-100 |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum |
| Typical Cool-Down Time | 1–2 h |
| Vibration Level | Not Specified |
| Optical Window | Yes |
| Window Diameter | 83–85 mm |
| Cold Head Mounting | Flexible (User-Defined Orientation) |
| Recommended Compressor Maintenance Interval | 13,000 h |
| Approximate Height | 56–84 cm |
| Approximate Weight | 16–29 kg |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-300S |
| Cooling Type | Closed-cycle cryocooler |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cool-down Time | 1.5–2.5 h |
| Vibration Level | <40 nm (RMS) |
| Optical Window | Yes |
| Window Diameter | 38 mm to 85 mm |
| Cold Head Mounting | Flexible (user-configurable orientation) |
| Recommended Cryocooler Maintenance Interval | 13,000 hours |
| Approximate Height | 71–99 cm |
| Approximate Weight | 17–30 kg |
| Compliance | Designed for integration into ISO/IEC 17025-compliant labs and GLP/GMP-adjacent research environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-300ST |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cooling Time | 1.5–2.5 h |
| Design | Compact, Magnet-Compatible |
| Optical Window | None |
| Cold Head Mounting | Flexible (Arbitrary Orientation) |
| Approximate Weight | 17–30 kg |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-400 |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 500 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cool-down Time | 1.5–3 h |
| Optical Window | Yes (83–85 mm diameter) |
| Vibration Level | <40 nm (RMS) |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Dimensions (H) | 61–89 cm |
| Weight | 16–30 kg |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-400H |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | 5 K to 800 K |
| Sample Environment | High-Vacuum Chamber |
| Typical Temperature Stability | ±50 mK |
| Cooling Time (to base temperature) | 2–2.5 h |
| Optical Window Diameter | 83–85 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Vibration Level | <40 nm (RMS, at sample stage) |
| Cold Head Mounting | Flexible (top-mount configuration standard) |
| Weight | 16–30 kg |
| Height | 66–94 cm |
| Compliance | Designed for ASTM E220, ISO/IEC 17025-compliant lab environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-800 |
| Price | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4.5 K to 300 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange Gas (He) |
| Optical Window | Optional |
| Sample Loading | Top-Access |
| Sample Chamber Inner Diameter | 38 mm |
| Rotatable Sample Stage | Yes |
| Cool-Down Time | 2–2.5 h |
| Cryocooler Mounting | Bottom-Mounted |
| Vibration-Induced Linewidth Broadening | ≤0.01 mm/s (Δv/v) |
| Approximate Height | 142–168 cm |
| Weight | 27.2 kg (cryostat only) |
| Window Block Outer Diameter | 57.2 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Sample Exchange Time | ~5 min |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-900 |
| Quotation | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 800 K (2 K optional) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange Gas |
| Sample Types | Solid, Liquid, Powder |
| Sample Exchange Time | <10 min |
| Rotatable Sample Stage | Yes |
| Cool-down Time | 3–4 h |
| Cold Head Position | Top-Mounted |
| Optical Window | Standard (CCS-900), Optional (CCS-900-T) |
| Approximate Height | 114 cm (CCS-900), 114–168 cm (CCS-900-T) |
| Approximate Weight | 48 kg (CCS-900), 45–50 kg (CCS-900-T) |
| Sample Chamber Diameter | 38.1 mm |
| Customizable Chamber Dimensions | 28.6 mm, 38.1 mm, 60.3 mm |
| Window Block Diameter | 95.3 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-TRAP / CCS-TRAP-H |
| Pricing | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <8 K to 325 K / <9 K to 500 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum |
| Cool-down Time | 1–1.5 h |
| Cold Head Position | Bottom-Mounted |
| Approx. Height | 91.4 cm / 96.5 cm |
| Approx. Weight | 19.1 kg |
| Recommended Refrigerator Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-XG |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Vibration Level | <40 nm (RMS) |
| Typical Temperature Stability | ±50 mK |
| Cool-Down Time | 2–3 h |
| Optical Window Diameter | 83–85 mm |
| Approximate Height | 66–94 cm |
| Approximate Weight | 17–30 kg |
| Recommended Cold Head Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-XG-UHV |
| Price | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Ultra-High Vacuum (UHV) |
| Bake-Out Temperature (Cold Head Removed) | 200 °C |
| Cool-Down Time | 2–3 h |
| Vibration Level | <40 nm (RMS) |
| Cold Head Position | Top-Mounted |
| Optical Window | Not Standard |
| Approximate Height | 559–660 mm |
| Weight | Configuration-Dependent |
| Recommended Cold Head Maintenance Interval | 10,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | RGC |
| Cooling Medium | Helium (gaseous & liquefied) |
| Operating Principle | Closed-loop cryogenic recirculation with pulse-tube or GM-based cold head |
| Compatible Cryostats | Lake Shore ST-100, ST-300, ST-400, ST-500, STVP series |
| Base Temperature (with ST-500) | ≤3.3 K (RGC4-20), ≤3.5 K (RGC4-15), ≤3.9 K (RGC4-12), ≤4.3 K (RGC4-10) |
| Cooling Power @ 5 K | up to 280 mW (RGC4-20) |
| Vibration Level (ST-500 + RGC) | <50 nm RMS (1–100 Hz) |
| Sample Exchange | Cold-insertion compatible (no warm-up required) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | SHI-950 |
| Cooling Type | Closed-cycle refrigeration |
| Temperature Range | 1.5 K to 800 K (300 mK with optional He-3 insert) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange gas |
| Sample Types | Solid, liquid, powder |
| Sample Exchange Time | <10 min |
| Cool-down Time | 8–9 h |
| Sample Cooling Time | ~80 min |
| Cryocooler Mounting | Top-mounted |
| Rotation Capability | Yes |
| Optical Window | Standard (configurable) |
| Sample Chamber Diameter | 51 mm (customizable) |
| Window Block Size | 108 mm square (standard) |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Approximate Height | 142–168 cm |
| Approximate Weight | 113.4 kg |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ST Series |
| Pricing | Available Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-100 |
| Cooling Method | Liquid Helium or Liquid Nitrogen Continuous-Flow |
| Temperature Range | 2 K to 500 K (ST-100) / 2 K to 800 K (ST-100-H) |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (~10⁻⁵ Torr typical) |
| Optical Access | Yes, with standard optical windows |
| Cool-down Time | ≤15 min to 5 K |
| System Mass (excl. cryolines) | ~4.6 kg |
| Initial Cryogen Consumption (LHe, RT → base T) | 0.4 L |
| Steady-State LHe Consumption @ 5 K | 0.6 L/h |
| LN₂ Consumption @ 80 K | 0.1 L/h |
| Vacuum Requirement (initial) | ~10⁻³ Torr |
| Mounting Orientation | Omnidirectional |
| Sample Compatibility | Solid, thermally conductive specimens |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-300 |
| Temperature Range | 2 K to 500 K |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (Typical Operating Pressure: ~10⁻⁵ Torr) |
| Cooling Medium | Liquid Helium (down to 2 K) or Liquid Nitrogen (down to 77 K) |
| Cool-down Time to 5 K | ≤15 min |
| System Mass (excl. Transfer Lines) | ~4.6 kg |
| LN₂ Consumption @ 80 K | 0.1 L/h |
| LHe Consumption @ 5 K | 0.6 L/h |
| Initial LHe Fill (RT → Base Temp) | 0.4 L |
| Vacuum Requirement (Initial) | ~10⁻³ Torr |
| Optical Access | Standard Integrated Windows |
| Mounting Orientation | Omnidirectional |
| Compatibility | RGC Helium Recirculation Cryocooler (Helium-Free Operation) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-400 |
| Cooling Method | Liquid Helium (with optional RGC helium recirculator) |
| Temperature Range | 2 K to 500 K (ST-400) |
| Base Pressure | ≤1×10⁻¹¹ Torr |
| Temperature Stability | ±50 mK |
| Cool-down Time to 5 K | ≤15 min |
| Sample Environment | High-vacuum or ultra-high vacuum (UHV) chamber |
| Sample Mounting | Customizable sample holders (optical, DC, 4-probe, plug-in) |
| Optical Window Options | X-ray to THz spectral range |
| Electrical Feedthroughs | DC, BNC, SMA, triaxial |
| Initial LN₂ Consumption @ 80 K | 0.1 L/h |
| Liquid Helium Consumption @ 5 K | 0.6 L/h |
| System Mass (excl. transfer lines) | ~4.6 kg |
| Required Initial Pump-down | ~10⁻³ Torr |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-500 |
| Temperature Range | 3.5 K to 475 K |
| Sample Environment | High Vacuum (1×10⁻⁵ Torr typical) |
| Vibration Level | ±15 nm RMS |
| Working Distance | As low as 1 mm |
| Cool-down Time | ~30 min to 5 K |
| Thermal Stability | ±50 mK |
| Optional Vacuum Extensions | LGV Large Vacuum Shroud, Superconducting Magnet & Electromagnet Integration Kits |
| Optical Window Options | X-ray to THz transmission range |
| Electrical Feedthrough Options | DC, BNC, SMA, Triaxial |