Refrigeration Equipment
Filter
Showing 541–570 of 1585 results
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP Series |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP-100 |
| Pricing | Upon Request |
| Cooling Medium | Liquid Helium or Liquid Nitrogen |
| Temperature Range | <2 K to 325 K (LHe), 65 K to 325 K (LN₂) |
| Temperature Stability | ±50 mK |
| Sample Environment | Continuous-flow cryogenic vapor |
| Cool-down Time to 5 K | 30 min |
| Optical Window | Optional |
| Top-Loading Configuration | Yes |
| Rotatable Sample Stage | Yes |
| Mounting Orientation | Vertical (required below 4.5 K) |
| Helium Consumption | 0.5 L (cooldown from RT to 4.2 K), 1.3 L/h (steady-state @ 5 K) |
| Height | 762 mm |
| Internal Sample Chamber Diameter | 38.1 mm |
| Sample Insertion Depth | 31 mm |
| Optical Window Block Size | 82.6 mm square |
| Weight (unit only) | 7 kg |
| Shipping Weight (unit + transfer line) | 61 kg |
| Shipping Dimensions | 1905 × 990.6 × 431.8 mm |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP-FTIR / ST-FTIR / VPF-FTIR |
| Quotation | Upon Request |
| Temperature Range | 2 K to 500 K (STVP/ST), 65 K to 500 K (VPF) |
| Cooling Method | Liquid Helium (STVP/ST), Liquid Nitrogen (VPF) |
| Sample Environment | Flowing Vapor (STVP), High Vacuum (ST, VPF) |
| Temperature Stability | ±50 mK |
| Cool-down Time | ≤15 min to 5 K (STVP/ST), ≤15 min to 77 K (VPF) |
| Optical Access | Four Configurable Windows |
| Window Material Options | CaF₂, BaF₂, Sapphire, Polyethylene, Mylar, Silicon, Germanium (covering Far-IR to X-ray) |
| Translation Stage Travel | 51 mm |
| Sample Holder | 3-Position Rotatable Mount |
| Mounting Interface | Standard ISO-KF or CF Flange |
| Compatibility | Commercial FTIR Spectrometers (Bruker, Thermo Fisher, PerkinElmer, Nicolet) |
| Optional Accessories | Electrical Feedthroughs (DC, BNC, SMA, Triaxial), Custom Sample Stages (4-Probe, Plug-in, Optical), Vacuum-Compatible Thermometry (Cernox®, RuO₂, Diode) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP-NMR |
| Pricing | Upon Request |
| Temperature Range | <2 K (1.5 K in single-point mode) to 325 K (420 K optional) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Continuous-flow helium vapor |
| Cooling Method | Liquid Helium |
| Cool-down Time | 30 min to 5 K |
| Sample Chamber Internal Diameter | 55 mm |
| Installation Orientation | Vertical (required below 4.5 K) |
| Liquid Helium Consumption | 0.5 L (from RT to 4.2 K) |
| Approx. Weight (unit only) | 7 kg |
| Approx. Shipping Weight | 79 kg |
| Approx. Shipping Dimensions | 1905 × 990.6 × 431.8 mm |
| Compatibility | Optimized for 89 mm bore NMR magnets, customizable for other bores |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | VNF-100 |
| Cooling Method | Liquid Nitrogen (LN₂) |
| Temperature Range | 65 K to 325 K (VNF-100) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Flowing Nitrogen Vapor |
| Sample Types | Non-conductive & Conductive Solids, Liquids, Powders |
| Sample Exchange Time | ≤10 min |
| Cool-down to 77 K | ≤30 min |
| LN₂ Capacity | 1.2 L |
| Typical Hold Time | 6–8 h |
| Optical Window | Standard (VNF-100), Optional (VNF-100-TH) |
| Sample Chamber Inner Diameter | 30 mm (VNF-100), 22.35 mm (VNF-100-TH) |
| Height | 583 mm (VNF-100), 812.8 mm (VNF-100-TH) |
| Weight | 11.5 kg (net), 15.9 kg (shipping) |
| Shipping Dimensions | 762 × 508 × 431.8 mm |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | VPF-100 |
| Quotation | Upon Request |
| Cooling Method | Liquid Nitrogen (LN₂) Fill |
| Temperature Range | 65 K to 500 K (VPF-100), 65 K to 800 K (VPF-100-H) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (~10⁻⁴ Torr) |
| Sample Types | Conductive, Solid |
| Cool-down Time to 77 K | 15 min |
| LN₂ Hold Time at 77 K | 8 h (VPF-100), 5 h (VPF-100-H) |
| LN₂ Hold Time at 100 K | 4.5 h |
| LN₂ Hold Time at 200 K | 2.5 h |
| Optical Window | Standard |
| Height (approx.) | 583 mm |
| Sample Chamber Inner Diameter | 76.2 mm (VPF-100), 63.5 mm (VPF-100-H) |
| Sample Mounting Diameter | 31.75 mm |
| Net Weight (approx.) | 3.3 kg |
| Shipping Weight (approx.) | 9.1 kg |
| Shipping Dimensions (approx.) | 610 × 406 × 305 mm |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-1030 |
| Price | USD 2,750 (FOB Jiangsu) |
| Temperature Range | −10 to 100 °C |
| Temperature Stability | ±0.05 °C |
| Chamber Dimensions | 400 × 325 × 230 mm (L×W×H) |
| Capacity | 30 L |
| Circulation Pump Flow Rate | 15 L/min |
| Opening Dimensions | 310 × 280 mm |
| Construction | Full Stainless Steel Interior and Work Surface |
| Control System | Digital Microprocessor-Based PID Controller with Dual Internal/External Circulation Modes |
| Safety Protections | Compressor Overheat & Overcurrent Protection |
| Optional Accuracy | ±0.01 °C or ±0.001 °C (with high-stability sensor and advanced PID tuning) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-5E |
| Pricing | Available Upon Request |
| Temperature Control Range | 22.0 °C ± 2.0 °C |
| Alarm Thresholds | <20 °C or >24 °C |
| Oscillation Amplitude | 50 mm |
| Oscillation Frequency | 60 cycles/min |
| Oscillation Mode | Continuous horizontal reciprocating motion |
| Refrigeration System | Fan-cooled, R134a refrigerant |
| Compressor | Danfoss (Denmark) |
| Defrosting | Automatic |
| UV Sterilization | Integrated |
| Temperature Monitoring | Digital sensor with microprocessor control |
| Data Logging | Real-time LCD display with thermal printer interface |
| Ambient Operating Temperature | 5–35 °C |
| Input Voltage | 220–240 V AC, 50/60 Hz |
| Rated Current | 3.5 A |
| Cooling/Heating Power | 100 W each (IA-type) |
| External Dimensions (W×D×H) | 540 × 605 × 960 mm |
| Internal Chamber Dimensions (W×D×H) | 300 × 300 × 230 mm |
| Capacity | 5–10 platelet storage bags |
| Shelving | 5-tier adjustable rack |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LBSW-5E |
| Quotation | Upon Request |
| Temperature Control Range | 22.0 °C ± 2.0 °C |
| Alarm Thresholds | < 20 °C or > 24 °C |
| Oscillation Amplitude | 50 mm |
| Oscillation Frequency | 60 cycles/min |
| Oscillation Mode | Continuous horizontal reciprocating motion |
| Refrigeration System | Fan-cooled, R134a refrigerant |
| Compressor | Danfoss (Denmark) |
| Defrosting | Automatic |
| UV Sterilization | Integrated |
| Power Supply | 220–240 V AC, 3.5 A, 50/60 Hz |
| Cooling/Heating Power | 100 W each (IA-type) |
| External Dimensions (W×D×H) | 540 × 605 × 960 mm |
| Internal Chamber Dimensions (W×D×H) | 300 × 300 × 230 mm |
| Capacity | 5–10 platelet storage bags |
| Shelving | 5-tier adjustable stainless-steel racks |
| Ambient Operating Temperature | 5–35 °C |
| Data Logging | Real-time temperature recording with thermal printer output |
| Display | LCD interface with microprocessor-based control |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Integral 280 XTW |
| Cooling Method | Water-cooled |
| Temperature Range | –80 to +220 °C |
| Cooling Capacity | 9000 W |
| Temperature Stability | ±0.05 K |
| Circulation Pump Pressure | 3.1 bar |
| Circulation Flow Rate | 65 L/min |
| Reservoir Volume | 4.8–17.2 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 2050 PW |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –40 to +140 °C |
| Refrigeration Capacity | 15,000 W |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 6.0 bar |
| Pump Flow Rate | 120 L/min |
| Reservoir Volume | 11.1–36.3 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 230 TW |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –30 to 120 °C |
| Refrigeration Capacity | 2300 W |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 3.5 bar |
| Pump Flow Rate | 40 L/min |
| Reservoir Volume | 3.6–8.7 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 150 XT |
| Cooling Method | Air-Cooled |
| Temperature Range | -45 to 220 °C |
| Cooling Capacity | 1.5 kW (at 20 °C, Pump Level 8) |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 3.1 bar |
| Pump Flow Rate | 65 L/min |
| Reservoir Volume | 2.5–8.7 L |
| Operating Mode | Continuous |
| Heater Power | 3.5 kW |
| Max. Power Consumption | 3.7 kW |
| Noise Level | 60 dB(A) |
| Net Weight | 103 kg |
| Dimensions (W×D×H) | 430 × 550 × 760 mm |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 1590 XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | −90 °C to 220 °C |
| Refrigeration Capacity | 18.5 kW |
| Temperature Stability | ±0.05 °C |
| Circulation Pump Pressure | 3.1 bar |
| Circulation Flow Rate | 65 L/min |
| Bath Volume | 30.6 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 1850 XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | –50 °C to +220 °C |
| Refrigeration Capacity | 20,000 W |
| Temperature Stability | ±0.05 °C |
| Circulating Pump Pressure | 6.0 bar |
| Circulating Pump Flow Rate | 120 L/min |
| Bath Volume | 8.0–28.6 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 550XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | −50 °C to 220 °C |
| Cooling Capacity | 5800 W |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 3.1 bar |
| Pump Flow Rate | 65 L/min |
| Reservoir Volume | 4.8–17.2 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 950 XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | -50 °C to 220 °C |
| Refrigeration Capacity | 9500 W |
| Temperature Stability | ±0.05 °C |
| Circulation Pump Pressure | 3.1 bar |
| Circulation Flow Rate | 65 L/min |
| Reservoir Volume | 4.8–17.2 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP 100 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 4–80 °C |
| Refrigeration Capacity | 60 W (at 10 °C output) |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 0.8 bar |
| Circulation Flow Rate | 2.6 L/min |
| Bath Volume | 0.28 L |
| Operating Mode | Continuous |
| Display | High-Contrast OLED Graphic Screen |
| Interface | RS232 |
| Power Supply | 100–240 V, 50/60 Hz |
| Max. Power Consumption | 0.24 kW |
| Dimensions (W×D×H) | 175 × 301 × 266 mm |
| Net Weight | 6.5 kg |
| Noise Level | 57 dB(A) |
| Fluid Compatibility | Water, Water/Ethylene Glycol Mixtures (Non-Flammable Only) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP 250 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 4–80 °C |
| Refrigeration Capacity | 130 W (at 10 °C output) |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 0.8 bar |
| Circulation Flow Rate | 2.6 L/min |
| Bath Volume | 0.32 L |
| Operating Mode | Continuous |
| Heating Power | 400 W |
| Pump Max Flow (at zero head) | 3 L/min |
| Dimensions (W×D×H) | 261 × 368 × 312 mm |
| Weight | 12 kg |
| Noise Level | 57 dB(A) |
| Power Supply | 100–240 V, 50/60 Hz |
| Protection Class | IP20 |
| Fluid Compatibility | Water, Water/Glycol Mixtures (non-flammable) |
| Interface | RS232 |
| Display | High-contrast OLED Graphical Screen |
| Control Interface | 3-button intuitive navigation |
| Connection | Quick-release 1/4″ C-type fittings |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP L100 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 4–80 °C |
| Temperature Stability | ±0.1 K |
| Refrigeration Capacity (at 20 °C) | 0.12 kW |
| Circulating Pump Pressure | 0.8 bar |
| Flow Rate | 3 L/min |
| Bath Volume | 0.28 L |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Mode | Plug-and-Play |
| Refrigerant-Free Operation | Yes |
| Compatible Heat Transfer Fluids | Water, Water-Glycol Mixtures (Non-Flammable) |
| Dimensions (W×D×H) | 175 × 301 × 266 mm |
| Weight | ~6.2 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Microcool |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 °C to +50 °C |
| Refrigeration Capacity | 1200 W |
| Temperature Stability | ±0.5 K |
| Circulation Pump Pressure | 1.3 bar |
| Circulation Flow Rate | 35 L/min |
| Reservoir Volume | 7 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 1200 |
| Cooling Method | Air-Cooled |
| Temperature Range | –10 to +40 °C |
| Refrigeration Capacity | 1.20 kW at 20 °C (Ethanol) |
| Temperature Stability | ±0.5 °C |
| Pump Pressure | Up to 1.3 bar |
| Pump Flow Rate | 35 L/min |
| Reservoir Volume | 14.0 L |
| Operating Mode | Continuous |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.575 kg) |
| Dimensions (W × D × H) | 450 × 550 × 650 mm |
| Weight | 63 kg |
| Sound Pressure Level | 59 dB(A) |
| Max. Power Consumption | 1.15 kW |
| Max. Current | 6.5 A |
| Inlet/Outlet Thread | G 3/4" |
| Minimum Fill Volume | 7 L |
| Maximum Fill Volume | 14 L |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 250 |
| Cooling Method | Air-Cooled |
| Temperature Range | –10 to 40 °C |
| Refrigeration Capacity | 0.25 kW at 20 °C (ethanol) |
| Temperature Stability | ±0.5 K |
| Pump Max. Pressure | 0.35 bar |
| Pump Flow Rate | 16 L/min |
| Reservoir Volume | 2.0–4.0 L |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.085 kg) |
| Dimensions (W×D×H) | 200 × 350 × 465 mm |
| Weight | 25 kg |
| Noise Level | 60 dB(A) |
| Max. Power Consumption | 0.23 kW |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 350 |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 to 40 °C |
| Cooling Capacity | 0.35 kW (at 20 °C with ethanol) |
| Temperature Stability | ±0.5 K |
| Pump Pressure | up to 0.35 bar |
| Pump Flow Rate | 16 L/min |
| Reservoir Volume | 4.0–7.0 L |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.095 kg) |
| Noise Level | 60 dB(A) |
| Dimensions (W×D×H) | 240 × 400 × 500 mm |
| Weight | 34 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 600 |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 to 40 °C |
| Refrigeration Capacity | 0.60 kW at 20 °C (Ethanol) |
| Temperature Stability | ±0.5 °C |
| Pump Pressure | up to 1.3 bar |
| Pump Flow Rate | 35 L/min |
| Reservoir Volume | 4.0–8.0 L |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.295 kg) |
| Dimensions (W×D×H) | 240 × 400 × 500 mm |
| Weight | 50 kg |
| Noise Level | 57 dB(A) |
| Max. Power Consumption | 0.7 kW |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model Range | MC250, MC350, MC600, MC1200 |
| Temperature Range | −10 to +40 °C |
| Temperature Stability | ±0.5 K |
| Cooling Capacity (at 20 °C) | 0.25–1.2 kW |
| Max. Pump Pressure | 1.3 bar |
| Max. Pump Flow Rate | 2–14 L/min |
| Bath Volume | 2–7 L |
| Construction | Benchtop (MC250/MC350) and Floor-Standing (MC600/MC1200) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 240 EC |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Hybrid (Air- and Water-Cooled) |
| Temperature Range | -40 to 200 °C |
| Cooling Capacity | 600 W at 20 °C |
| Temperature Stability | ±0.05 K |
| Pump Pressure | 0.68 bar |
| Pump Flow Rate | 22 L/min |
| Reservoir Volume | 2.4–4.4 L |
| Internal Fill Volume | Minimal (Optimized for Rapid Thermal Response) |
| Refrigerant | R-449A (GWP 1397, compliant with EU Regulation (EU) No 517/2014) |
| Power Supply | 230 V, 50 Hz |
| Max. Power Consumption | 3.7 kW |
| Dimensions (W×D×H) | 300 × 430 × 675 mm |
| Weight | 40 kg |
| Compliance | DIN 12876 Class I |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 245 EC |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Hybrid (Air- and Water-Cooled) |
| Temperature Range | -45 to 200 °C |
| Cooling Capacity | 800 W at 20 °C |
| Temperature Stability | ±0.05 K |
| Circulating Pump Pressure | 0.68 bar |
| Circulating Pump Flow Rate | 22 L/min |
| Reservoir Volume | 2.4–4.4 L |
| Internal Fill Volume | Minimal (Optimized for Rapid Thermal Response) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 250 EC |
| Cooling Method | Hybrid (Air- and Water-Cooled) |
| Temperature Range | -50 to 200 °C |
| Temperature Stability | ±0.05 K |
| Refrigeration Capacity | 1.5 kW |
| Pump Pressure | 0.68 bar |
| Pump Flow Rate | 22 L/min |
| Bath Volume | 2.4–4.4 L |
| Heating Power | 2.5 kW |
| Internal Fill Volume | Minimal (Optimized for Rapid Thermal Response) |
| Refrigerant | R-452A (GWP 2140, compliant with EU Regulation (EU) No 517/2014) |
| Compliance | DIN 12876 Class I |
| Dimensions (W×D×H) | 300 × 430 × 675 mm |
| Weight | 48 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 290 EC |
| Cooling Method | Hybrid (Air- and Water-Cooled) |
| Temperature Range | –90 °C to +200 °C |
| Cooling Capacity | 800 W at 20 °C |
| Temperature Stability | ±0.05 °C |
| Circulating Pump Pressure | 0.68 bar |
| Flow Rate | 22 L/min |
| Reservoir Volume | 2.4–4.4 L |
| Heating Power | 2.5 kW |
| Max. Power Consumption | 3.7 kW |
| Refrigerants | R-452A (0.300 kg, GWP 2140) & R-170 (0.070 kg, GWP 3) |
| Compliance | DIN 12876, EU F-Gas Regulation (EU) No. 517/2014 |
| Interface Options | USB, Ethernet, RS-232/485, Profibus, EtherCAT, Analog I/O |
| Pump Type | LAUDA Varioflex (8-stage adjustable, pressure/suction capable) |
| Display | 5.7″ multi-touch color LCD |
| Programmability | 100 programs × 50 segments |
| User Management | Up to 20 users |
| Safety | Adjustable overtemperature protection with acoustic alarm |
| Dimensions (W×D×H) | 390 × 600 × 685 mm |
| Weight | 80 kg |