Sample Preparation Workstation
Filter
Showing 61–90 of 117 results
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | GASTORR PG-11 / GASTORR PG-12 |
| Flow Paths | 1 / 2 |
| Internal Chamber Volume | 62.0 mL |
| Max. Flow Rate | 50.0 mL/min |
| Ultimate Vacuum | 150 hPa |
| Vacuum Control Resolution | ±5 hPa |
| Wetted Materials | PTFE, ETFE, SUS316L, PEEK |
| Dimensions (W×H×D) | 66 × 180 × 285 mm (excl. protrusions) |
| Power Supply | AC 100–240 V, 50/60 Hz, 250 VA |
| Weight | 2.0 kg / 2.4 kg |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JT-GHX-DC |
| Light Source Compatibility | Mercury, Xenon, and Metal Halide Lamps (0–1000 W for Hg/Xe |
| Reaction Vessel Options | Quartz tubes (30 mL, 50 mL) or custom sizes |
| Sample Capacity | 8-position magnetic stirring (configurable to 6 or 12) |
| Cooling System | Dual-layer quartz cold finger with external recirculating chiller (cooling capacity >1000 W |
| temp range | −5 °C to 100 °C) |
| Safety | Overtemperature cutoff, radiation-shielded dark chamber with observation window, high-voltage lamp housing, integrated power sockets for lamps and stirrers |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JTZL-6C |
| Heating Method | 6-channel Far-Infrared Ceramic Heater (≤800 W per channel) |
| Distillation Capacity | 6 samples simultaneously |
| Distillation Rate | 12 mL/min |
| Temperature Range | Ambient to 320 °C |
| Endpoint Control | Dual-mode (gravimetric ±2 mL accuracy or timer 0–999 min) |
| Cooling System | Built-in air-cooled recirculating water unit |
| Display | 7-inch capacitive touch LCD |
| Single-Channel Temperature Control | Yes |
| Anti-Suck-Back | Electromagnetic vacuum valve |
| Power Supply | 220 V / 50 Hz |
| Flask Compatibility | Six 500 mL or 250 mL round-bottom flasks |
| Warm-up Time | 5–20 min |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AutoLiquid-Powder Dispensing System |
| Price Range | USD 260,000 – 390,000 (converted at ~1:0.77) |
| Capacity | 45 × 50 mL centrifuge tubes |
| Dispensing Accuracy | ±1 mg (powder & liquid) |
| pH Measurement Range | 0–14 pH, ±0.01 resolution |
| pH Adjustment Precision | ≥1 µL acid/base delivery via syringe pumps |
| Temperature Measurement | −5 to 105 °C, ±0.1 °C |
| Conductivity Range | 10–200 mS/cm |
| Mixing | Integrated magnetic stirring during dispensing and pH adjustment |
| Calibration | Automated weight-based tare calibration and pH electrode 2-/3-point calibration |
| Cleaning | Automated probe rinse cycles for pH and conductivity sensors |
| Powder Feed Options | Dual-feed module (vibratory feeder for fine powders |
| Liquid Delivery | 3 peristaltic pumps + 3 syringe pumps |
| Cycle Time | Full 45-formulation workflow (dispense, mix, pH/conductivity monitoring, adjustment, capping) completed in ≤8 hours |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cryo-Mill & Precision Weighing Workstation |
| Price Range | USD 260,000 – 390,000 |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LABMAN Automation Platform |
| Price Range | USD 270,000 – 410,000 (FOB UK, ex-works pricing |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | Plant Sample Grinding and Weighing System |
| Price Range | USD 260,000 – 390,000 |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Solid Sample Preparation Workstation |
| Price Range | USD 260,000 – 390,000 |
| Brand | LANYO |
|---|---|
| Model | FASP-01 |
| Origin | Beijing, China |
| Application | Soil, sediment, and dry solid environmental samples |
| Sieve Options | 10 mesh / 60 mesh / 100 mesh / 200 mesh (per GB/T 6003.1–2022) |
| Sample Throughput | 500–3000 g per run |
| Cycle Time | ~25 min per sample |
| Grinding Architecture | Two-stage non-metallic jaw crushing (coarse), followed by suspension-impact fine grinding |
| Mixing Method | 3D vibrational tumbling mixing (flip-and-lift principle) |
| Contamination Control | Full non-metallic wetted path |
| Cleaning Protocol | Tri-mode automated cleaning — rotary brush sweep + compressed air blow-off + vacuum suction with HEPA-filtered exhaust |
| Data Integrity | RFID & QR-code sample tracking |
| Compliance Standards | HJ/T 166–2004, GB 17378.5–2007, NY/T 395–2012, DZ/T 0130.4–2006, HJ/T 20–1998, EJ/T 428–1989, LY/T 1210–1999 |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Model | FASP-01Pro |
| Application Scope | Soil, sediment, solid waste, rock, and geological samples |
| Automation Level | Fully automated with 30-position auto-inlet & auto-outlet |
| Grinding Stages | Dual-stage (coarse jaw + fine impact) |
| Sieve Sizes | 10, 60, 100, 200 mesh per GB/T 6003.1–2022 |
| Integrated Functions | Grinding, homogenization, sieving, quartering, weighing, vial loading, RFID/QR traceability, auto-cleaning (brush + vacuum) |
| Compliance | HJ/T 166–2004, NY/T 395–2012, DZ/T 0130.4–2006, HJ/T 20–1998, EJ/T 428–1989, LY/T 1210–1999, and 102+ related national/regulatory standards for solid environmental sample preparation |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Model | FASP-05B |
| Sample Capacity | 5 dry soil samples per batch |
| Sieve Sizes | 10 mesh (2 mm), 20 mesh (0.85 mm), 60 mesh (0.25 mm), 100 mesh (0.15 mm), 200 mesh (0.075 mm) |
| Compliance | HJ/T 166–2004, NY/T 395–2012, DZ/T 0130.4–2006, GB/T 6003.1–2022 |
| Automation | Dual independent robotic arms, non-metallic grinding components, integrated barcode scanning & auto-cleaning |
| Software | Audit-trail enabled sample tracking, GLP-compliant reporting, automated data export (CSV/PDF) |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Model | FASP-05D |
| Price Range | USD 140,000 – 280,000 |
| Sample Capacity | 5 fresh-sample positions |
| Drying Temperature Control | 35 ± 5 °C |
| Grinding Temperature Limit | ≤ 40 °C |
| Sieve Mesh Options (per GB/T 6003.1–2022) | 10, 20, 60, 80, 100, 160, 200 mesh (up to 4 selectable) |
| Barcode Scanning | 2D matrix |
| Compliance | HJ/T 166–2004, NY/T 395–2012, DZ/T 0130.4–2006, HJ/T 20–1998, EJ/T 428–1989, LY/T 1210–1999, and 102 additional national standards for soil, sediment, and solid waste sample preparation |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FASP-05DB |
| Pricing | Available Upon Request |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FASP-30B |
| Pricing | Upon Request |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Model | FASP-CG |
| Application | Soil sample preparation per HJ/T 166-2004, NY/T 1121.1-2006, and related national standards |
| Sample throughput | 500–3000 g (dry basis) |
| Sieve aperture | 2 mm (10 mesh, per GB/T 6003.1-2022) |
| Grinding architecture | Dual-stage non-metallic grinding system |
| Contamination control | Metal-free grinding & handling path |
| Automation scope | Integrated coarse grinding, sieving, homogenization, weighing, aliquoting, vial loading, and in-situ cleaning |
| Data traceability | Full digital log with timestamped process events and auto-generated compliance reports |
| Vial capacity | 1–6 × 500 mL amber glass bottles with label-ready caps |
| Compliance framework | Supports GLP-aligned workflows, audit-ready electronic records, and 21 CFR Part 11–compatible data integrity (when deployed with validated software environment) |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Model | FASP-Geo |
| Application Scope | Soil, sediment, solid waste, bedrock, and geological samples |
| Automation Level | Fully automated, unattended operation |
| Compliance | ASTM D6913, ISO 11277, USP <1058>, EPA Method 5035A, HJ/T 166–2004, NY/T 395–2012, DZ/T 0130.4–2006, HJ/T 20–1998, EJ/T 428–1989, LY/T 1210–1999 |
| Sample Throughput | Up to 30 samples per batch |
| Sieve Standards | GB/T 6003.1–2022 (10, 60, 100, 200 mesh) |
| Grinding Stages | Dual-stage — coarse jaw crushing + fine impact milling |
| Weighing Accuracy | ±0.01 g (integrated high-precision load cell) |
| Cleanliness Protocol | Brush + vacuum suction + acoustic dampening |
| Footprint | <2 m² |
| Modularity | Configurable inlet/outlet positions |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Model | RLTD-05/10 |
| Sample Capacity | 5 positions |
| Drying Temperature Control | 35 ± 5 °C |
| Contact Materials | Metal-free (non-interfering with target elements) |
| Compliance | HJ/T 166–2004, NY/T 395–2012, DZ/T 0130.4–2006, HJ/T 20–1998, EJ 428–1989, LY/T 1210–1999 |
| Control System | Software-based real-time temperature feedback per drying chamber |
| Mixing Mechanism | Automated in-situ tumbling during drying cycle |
| Cleaning | Smooth, non-porous contact surfaces for residue-free decontamination |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HXO-CW30L |
| Price Range | USD 700 – 1,400 |
| Brand | MAKEWAVE |
|---|---|
| Model | MKX-X1G1A-1L |
| Chamber Volume | 20 L |
| Digestion Vessel Capacity | 1 L |
| Microwave Power | 0–800 W (PID-controlled, continuous non-pulsed) |
| Frequency | 2450 MHz |
| Temperature Range | 0–260 °C (fiber-optic sensing) |
| Pressure Range | 0–3 MPa (capillary pressure transducer) |
| Vessel Material | Inner TFM |
| Safety Features | Dual-metal flange + screw-lock sealing, burst-disk pressure relief, <5 mW/cm² microwave leakage |
| Compliance | Meets GB 4706.21 & GB 10436 national safety standards for microwave equipment |
| Control System | PLC-based touchscreen interface with real-time T/P/Pwr/time curve logging and USB data export |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Series | MKZ/MGZ |
| Price Range | USD 14,000 – 42,500 |
| Microwave Frequency | 2450 MHz |
| Max. Microwave Power | 1600 W (MKZ-G2A) / 3200 W (MKZ-G4A) / 8000 W (MGZ-G10A) |
| Cavity Volume | 28 L / 100 L / 300 L |
| Construction Material | AISI 304 Stainless Steel, Fully Welded Vacuum Chamber |
| Vacuum Level | −0.093 MPa (measured at Qingdao elevation) |
| Temperature Range | 0–300 °C (infrared non-contact measurement) |
| Pressure Monitoring | Full-range vacuum pressure sensor |
| Control System | PLC-based HMI with color touchscreen, multi-segment program storage & parameter export |
| Safety Compliance | Microwave leakage <5 mW/cm² (GB 10436-2008), interlocked door, explosion-proof design, corrosion-resistant coating (PTFE optional) |
| Dimensions (W×D×H) | 655×550×800 mm / 1360×800×1600 mm / 1550×900×1800 mm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Axis Pro |
| Pricing | Available Upon Request |
| Brand | NAYO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A96 |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VacuumSaturator |
| Vacuum Chamber Diameter | 200 mm |
| Maximum Dry Evacuation Time | 960 min |
| Maximum Wet Evacuation Time | 240 min |
| Ultimate Vacuum Pressure | ≤ −0.095 MPa |
| Dimensions (L×W×H) | 800 mm × 600 mm × 1200 mm |
| Net Weight | 30 kg |
| Vacuum Pump Power | 370 W |
| Pump Ultimate Pressure | ≤ 5 Pa |
| Control Mode | Digital Timer with Adjustable Setpoints |
| Safety Features | Overpressure Relief Valve, Sealed Chamber Interlock, Leak-Test Function |
| Brand | OMNI International |
|---|---|
| Origin | USA |
| Model | Prep 96 |
| Sample Capacity | 96 samples per run |
| Volume Range | 250 µL – 40 mL (in 5–50 mL tubes) |
| Speed Range | 500–28,000 rpm |
| Motor Configuration | Four 100 W brushless DC motors |
| Tip Compatibility | 7 mm & 12 mm OMNI Tips™ plastic homogenizer probes |
| Motion Profile | Dual-axis oscillatory motion (vertical + horizontal) |
| Noise Level | ≤75 dB(A) |
| Dimensions (W×D×H) | 95.2 cm × 64.8 cm × 72.9 cm (96.5 cm with lid open) |
| Weight | 57 kg |
| Certifications | TÜV, NRTL, CE, UKCA, RCM, KCC, FCC Part 15 |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | PRI-3000 |
| Price Range | USD 42,000–70,000 |
| Vacuum Channels | 15 |
| Ultimate Vacuum Pressure | 2 Pa |
| Pressure Measurement Range | 1–1000 Pa (Resolution: 0.1 Pa) |
| Heating Temperature Range | Ambient to 150 °C |
| Cryogenic Cooling | Integrated Compressor-Based System, Down to −100 °C |
| Sample Tube Volume | 5–15 mL |
| System Leak Rate | ≤1 Pa/min |
| Vacuum Pump Flow Rate | 5 L/s |
| Extraction Throughput | Up to 120 Samples/Day |
| Extraction Efficiency | >98% |
| Water Recovery Rate | 98–100% |
| Dimensions (W×D×H) | 100 × 60 × 95 cm |
| Sample Tube Interface | Flanged Borosilicate Glass Assembly |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PRI-8800 |
| Price Range | USD 42,000 – 70,000 |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | PRI-8800 Plus |
| Pricing | Upon Request |
| Sample Chamber Dimensions | 8 cm D × 50 cm H |
| Sample Positions | 9 |
| Temperature Range | −15 to 60 °C |
| Temperature Stability | ±0.05 °C |
| Avg. Ramp Rate (5–30 °C) | 1 °C / 5 min |
| Internal Cavity | 530 mm W × 530 mm D × 500 mm H |
| Auto-sampler Positioning Accuracy | 0.02 mm |
| Barometric Sensor Accuracy | ±0.05% FS |
| Soil Temp. Sensor Accuracy | ±0.15 °C |
| Gas Flow Rate | 1 L/min |
| Tubing | 1/8″ SS or PTFE |
| Purge Gas | Ambient air buffer or cylinder gas |
| Power | 100–240 VAC, 50/60 Hz |
| Overall Dimensions | 762 mm W × 950 mm D × 1700 mm H |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Auto IPS-6080 |
| Pricing | Upon Request |
| Sample Positions | 40 |
| Loading Tube Volume | 12 mL |
| Collection Vial Capacity | 4 mL (vials) or 7 mL (glass test tubes) |
| Compatible Column Format | Standard 3 mL immunoaffinity columns |
| Throughput | 10–15 samples/hour |
| Recovery Rate | ≥90% |
| Recovery RSD | ≤5% |
| Fluidic Architecture | Fully independent pneumatic and liquid pathways |
| Tubing Materials | PTFE, PEEK, PP |
| Elution Precision | Piston pump-based delivery, accuracy <1% |
| Reagent Level Detection | Non-contact real-time monitoring with auto-pause on low-volume alert |
| Reagent Line Priming | Automatic fill, rinse, and purge (air/N₂) |
| Air Bubble Detection | In-line real-time bubble sensing with automatic pause |
| Waste Handling | Vacuum-assisted active waste aspiration |
| Programmable Methods | ≥10 user-editable, saveable, and recallable protocols |
| Control System | 32-bit high-speed embedded distributed controller |
| Display | 10-inch full-color wide-view industrial touchscreen |
| Dimensions (L×W×H) | 550 × 460 × 450 mm |
| Weight | 30 kg |
| Operating Environment | 10–40 °C, 20–85% RH, 86.0–106.0 kPa |
| Power Supply | 220 V ±10%, 50 Hz, grounded |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MCS-3000 |
| Pricing | Available Upon Request |
| Brand | Pribolab |
|---|---|
| Model | MP2000S |
| Origin | Shandong, China |
| Construction | Aluminum oxide sample tray, food-grade stainless steel homogenizing probe |
| Dimensions (H×W×D) | 550 × 360 × 630 mm |
| Weight | 33 kg |
| Standard Tray Capacity | 6-position (compatible with 100 mL and 300 mL sample bottles) |
| Optional Trays | 10-position and custom configurations |
| Probe Speed Range | 0–25,000 rpm (10-step BLDC motor control) |
| Positioning Accuracy | < 0.5 mm (mechanical arm), repeatability < 0.1 mm |
| Cleaning System | Multi-solvent rinse + ultrasonic cleaning + reverse-rotation probe cleaning |
| Control Interface | Touchscreen with editable, savable homogenization methods |
| Homogenization Motion | Vertical amplitude adjustment during operation |
| Enclosure | Powder-coated steel housing with ergonomic 3D panel design |