BrandCampbell Scientific
ModelIRGASON
OriginUSA
TypeIntegrated Open-Path Eddy Covariance System
Operating Temperature−30 to +50 °C
Operating Pressure70–106 kPa (expandable)
Supply Voltage10–16 VDC
Average Power Consumption5 W @ 25 °C
Measurement Frequency60 Hz
Output Bandwidth Options5, 10, 12.5, 20 Hz
Data Output InterfacesSDM, RS-485, USB, Analog (CO₂/H₂O only)
Gas Path Length15.37 cm
CO₂ Accuracy±1% of reading
H₂O Accuracy±2% of reading
CO₂ Precision (RMS)0.2 mg/m³ (0.15 µmol/mol)
H₂O Precision (RMS)0.004 g/m³ (0.006 mmol/mol)
CO₂ Calibration Range0–1,000 µmol/mol (extendable to 3,000 µmol/mol)
H₂O Calibration Range0–72 mmol/mol (at 38 °C dew point)
CO₂ Temperature-Dependent Gain Drift±0.1% reading/°C
H₂O Temperature-Dependent Gain Drift±0.3% reading/°C
CO₂–H₂O Cross-Sensitivity±1.1×10⁻⁴ mol CO₂/mol H₂O
H₂O–CO₂ Cross-Sensitivity±0.1 mol H₂O/mol CO₂
Ultrasonic Anemometer Path LengthsVertical 10.0 cm, Horizontal 5.8 cm
Wind Speed Range (uₓ/uᵧ)±65 m/s
Wind Speed Range (u_z)±8 m/s
Wind Direction Range2.5°–357.5° (0–360° customizable)
Ultrasonic Temperature Range−50 to +60 °C
uₓ/uᵧ Offset Error<±8.0 cm/s
u_z Offset Error<±4.0 cm/s
Wind Direction Offset Error±0.7°
Gain Error (at ±5° tilt)<±2% reading
uₓ/uᵧ Precision (RMS)1 mm/s
u_z Precision (RMS)0.5 mm/s
Wind Direction Precision (1 m/s wind)0.06°
Ultrasonic Temperature Precision0.0025 °C
Total Mass6 kg
Warranty3 years from factory shipment or 17,500 operational hours, whichever occurs first
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCampbell Scientific
ModelCPEC310
OriginUSA
System TypeClosed-path eddy covariance flux measurement system
Power Consumption12 W @ 25°C
Operating Temperature−30 to +50°C
Operating Pressure Range70–106 kPa (expandable)
Measurement Frequency60 Hz
Output Rates5, 10, 12.5, or 20 Hz
Data InterfacesSDM, RS-485, USB, analog (CO₂/H₂O only)
Total Mass15.36 kg
Warranty1 year from shipment
Gas Analyzer Sample Cell Volume5.9 mL
Cutoff Frequency4.3 Hz
CO₂ Accuracy±1% of reading
H₂O Accuracy±2% of reading
CO₂ Precision (RMS)≤0.15 µmol/mol
H₂O Precision (RMS)≤0.006 mmol/mol
CO₂ Zero Drift±0.3 µmol/mol/°C
H₂O Zero Drift±0.05 mmol/mol/°C
CO₂ Gain Drift±0.1% reading/°C
H₂O Gain Drift±0.3% reading/°C
Cross-sensitivityCO₂ → H₂O: ±1.1×10⁻⁴ mol CO₂/mol H₂O
H₂O → CO₂±0.1 mol H₂O/mol CO₂
CSAT3A Path LengthsVertical 10.0 cm, Horizontal 5.8 cm
Wind Speed Rangeuₓ/uᵧ ±65 m/s, u_z ±8 m/s
Wind Direction Range2.5°–357.5° (0–360° customizable)
Sonic Temperature Range−50 to +60°C
Sonic Temperature Precision0.0025°C RMS