Empowering Scientific Discovery

Shanghai Baineng Instrumentation & Metering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41502
MaterialUV-stabilized white thermoplastic housing, anodized aluminum support frame, stainless steel mounting hardware
Dimensions20 cm (diameter) × 33 cm (height)
Net Weight1.1 kg
Shipping Weight~2.7 kg
Power Supply12–14 VDC @ 500 mA
Airflow Rate5–11 m/s (16–35 ft/s), dependent on sensor power draw
Radiative Error (Temperature)≤0.2 °C RMS at 1000 W/m² solar irradiance
Delta-T Error≤0.05 °C RMS under identical shielding exposure
Fan Lifetime>80,000 hours continuous operation at 25°C
Sensor CompatibilityRTD-based temperature probes (e.g., 41342), combined RH/T probes (e.g., 41382)
Output Options4–20 mA or 0–1 VDC
Operating EnvironmentOutdoor, all-weather, low-wind-speed microclimates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41342
Measurement Range−50 to +50 °C
Accuracy (at 0 °C)±0.3 °C (standard), ±0.1 °C (optional)
Time Constant42 s (with 43408 radiation shield)
Sensor Type1000 Ω Pt RTD, 4-wire configuration
Output OptionsResistance (41342), 0–1 VDC (41342VC), 4–20 mA (41342LC)
CalibrationSelectable °C or °F
Recommended Radiation Shield43502 (aspirated) or 41003P (multi-plate passive)
Recommended Cable2-pair shielded, 22 AWG (P/N 18641)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41342VC
Output Signal0–1 VDC
Sensor TypePt1000 RTD (4-wire)
Measurement Range−50 to +50 °C
Accuracy @ 0 °C±0.3 °C (standard), ±0.1 °C (optional)
Time Constant42 s (with Model 43408 radiation shield)
Calibration Options°C or °F
EnclosureWeatherproof terminal housing
Recommended Radiation ShieldModel 43502 (aspirated) or Model 41003P (multi-plate passive)
Recommended Cable2-pair shielded, 22 AWG (e.g., Part #18641)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41003
Dimensions12 cm (D) × 27 cm (H)
Weight (net)0.7 kg
MountingU-bolt clamp for masts up to 2 inches (50.8 mm) diameter
Sensor compatibility41003 — up to 16 mm diameter
Radiative error (at 1080 W/m² solar irradiance)≤0.4 °C RMS @ 3 m/s wind speed
Housing materialUV-stabilized white thermoplastic with high-reflectivity, low-thermal-conductivity disk
ComplianceDesigned per WMO Guide to Meteorological Instruments and Methods of Observation (CIMO Guide), ISO 4690:2022 (Environmental monitoring — Performance requirements for radiation shields), ASTM D7237-21 (Standard Practice for Evaluation of Radiation Shields for Air Temperature Sensors)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRainWise
OriginUSA
ModelTWD
Temperature Range0–50 °C
Accuracy±0.15 °C
Resolution0.10 °C
Sensor TypePrecision Thermistor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelHT200
Temperature Range0–30°C
Accuracy±0.3°C
Resolution0.01°C
Response Time0.15 s
Output ProtocolNMEA 2000®
Update Rate2 Hz
Supply Voltage9–50 VDC
Current Draw≤30 mA
Cable Length6 m
Housing CompatibilityP17, B17, SS577
Mounting Hole Diameter51 mm
NMEA 2000 LEN1
Weight (Bronze)1.3 kg
Weight (Stainless Steel)1.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelB17-HP
Temperature Accuracy±0.3°C
Temperature Resolution0.01°C
Response Time Constant5 s
Operating Temperature Range0–30°C
Supply Voltage6–28 VDC
Max Current Draw30 mA
Output ProtocolsNMEA 0183 / NMEA 2000®
Output SentenceYXMTW (NMEA 0183), PGN 130310 (NMEA 2000®)
Mounting Hole Diameter51 mm
Housing Material OptionsBronze, Stainless Steel, Plastic
Profile Height5 mm
Cable Length (Max)100 m
Weight1.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41342LC
Output Signal4–20 mA
Measurement Range−50 to +50 °C
Accuracy (at 0 °C)±0.3 °C (±0.1 °C optional)
Time Constant42 s (with Model 43408 radiation shield)
Sensor Type1000 Ω Pt RTD (IEC 60751 Class B, standard
EnclosureWeatherproof junction box
CalibrationConfigurable for °C or °F output scaling
Recommended Radiation ShieldModel 43502 (aspirated) or Model 41003P (multi-plate passive)
Cable Recommendation2-pair shielded, 22 AWG (e.g., Part #18641)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0