Empowering Scientific Discovery

Shanghai Baineng Instrumentation & Metering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGeonica
OriginSpain
ModelSunTracker-3000
Power Consumption<3 W
Azimuth & Elevation Accuracy0.1° (passive), 0.02° (active with optional radiometer feedback)
Payload Capacity30 kg
Operating Temperature-20 to +60 °C
Relative Humidity0–100% RH
Weight25 kg
Dimensions460 × 490 × 490 mm
Drive MechanismPrecision worm-gear train
Torque35 N·m
Angular Velocity9.4°/s
Angular Acceleration136.4°/s²
MountingTripod base with dual bubble levels
Housing MaterialRust-resistant aluminum alloy, 304 stainless steel worm, bronze gear
Communication InterfaceRS-485 (external control module), RS-232/422/485 & Ethernet (METEODATA data logger)
Time SynchronizationInternet NTP or integrated GPS receiver
Positioning Update RateReal-time, 1 Hz (solar zenith and azimuth)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRMAR
OriginUSA
ModelTM275LHW
Power Output1000 W
Operating Frequency BandsLow Band 42–65 kHz (beam width 25°–16°), High Wideband 150–250 kHz (constant 25° beam width)
Max Depth Range914 m (low band), 152 m (high wideband)
Beam Mounting Angle Adjustment3°–21°
Housing MaterialSEALCAST™ seamless polyurethane encapsulation
Mounting TypeTransom-mount stainless steel bracket
Sensor Weight4 kg
Compatible Hull TypesAll hull materials (fiberglass, aluminum, wood, composites)
Hull Length Requirement≥10 m
Temperature SensorIntegrated fast-response thermistor
Total Frequency Span123 kHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRMAR
OriginUSA
ModelDX900+
Operating Frequency360 kHz
Depth Range60 m
Longitudinal Speed Range±60 knots
Transverse Speed Range±6 knots
Speed Accuracy±0.1 knots (≤10 kn), ±1% (>10 kn)
Speed Resolution0.01 knots
Temperature Accuracy±0.5 °C
Data Update Rateup to 10 Hz
Operating Temperature−15 °C to +55 °C
Power Supply9–16 VDC
Power Consumption5.0 W (DST variant), 2.5 W (ST variant)
Cable Length3 m (DST), 6 m (ST)
NMEA 2000® Load Equivalent Number (LEN)10
Weight1 kg
Housing MaterialMarine-grade corrosion-resistant alloy
Output ProtocolsNMEA 0183 (ST), NMEA 2000® (DST)
Wireless InterfaceBluetooth 5.0 for AIRMAR CAST™ app
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model05305
Instrument TypeCup Anemometer & Wind Vane Sensor
Resolution0.1 m/s
Measurement Range0–50 m/s (wind speed), 0–360° (wind direction)
Accuracy±0.2 m/s or ±1% of reading (wind speed), ±3° (wind direction)
Startup Wind Speed0.4 m/s (cup), 0.5 m/s (vane)
Operating Temperature−50°C to +50°C
Operating Humidity0–100% RH
Output OptionsAC pulse (3 pulses/rev), 0–5 VDC, or 4–20 mA
Housing MaterialUV-stabilized polymer with stainless steel and anodized aluminum hardware
Bearing TypePrecision stainless steel ball bearings
ComplianceEPA PSD Guidelines, NRC RG 1.23, ANSI/ANS-18.1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGill
OriginUnited Kingdom
ModelMetpak
Instrument TypePortable Weather Station
Enclosure RatingIP65
Operating Temperature−35 °C to +70 °C
Power Supply5–30 V DC (<16 mA @ 12 V, 1 Hz output)
Wind MeasurementUltrasonic (no moving parts)
Wind Speed Range0–60 m/s
Wind Direction Range0–359°
Wind Accuracy±2% @ 12 m/s (speed), ±3° @ 12 m/s (direction)
Air Temperature SensorPt100 1/3 Class B
Temp Range−35 °C to +70 °C
Temp Accuracy±0.1 °C
Relative Humidity SensorRotronic HygroClip HC2-53
RH Range0–100% RH
RH Accuracy±0.8% RH @ 23 °C
Barometric Pressure SensorHigh-precision capacitive
Pressure Range600–1100 hPa
Pressure Accuracy±0.5 hPa
Dew Point Accuracy±0.15 °C (at 23 °C ambient, 20 °C dew point)
Output ProtocolsASCII, NMEA 0183, SDI-12 v1.3, Modbus RTU/ASCII
Communication InterfacesRS232, RS422, RS485 (2-wire), SDI-12
Baud Rates4800–57600 (ASCII), 1200 (SDI-12)
Data Update Intervals1 s, 2 s, 4 s, or polled
MountingAnodized aluminum U-bracket for vertical masts Ø30–58 mm
Weight2.1 kg (including bracket)
MaterialsUV-stabilized white engineering plastic housing, anodized aluminum mounting hardware
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGILL
OriginUnited Kingdom
ModelMetPak Pro
Instrument TypePortable Weather Station
Enclosure RatingIP65
Operating Temperature−35°C to +70°C
Power Supply5–30 VDC (<26 mA @12 V, 1 Hz output)
Communication InterfacesRS232 / RS422 / RS485 (2-wire) / SDI-12 (user-selectable)
Output ProtocolsASCII, SDI-12 v1.3, NMEA 0183, Modbus RTU/ASCII
Data Logging Interval1 s / 2 s / 4 s / polled mode
Analog Inputs2 channels (0–5 V, 4–20 mA, or self-powered)
PT100 Input4-wire, IEC 60751 Class B compliant
Digital InputReed-switch or contact-closure for tipping-bucket rain gauge (up to 10 Hz)
ADC Resolution12-bit, ±0.1% of reading + 35 µV offset compensation
Wind MeasurementUltrasonic (GILL WindSonic), 0–60 m/s, 0–359°, ±2% @12 m/s (wind speed), ±3° @12 m/s (wind direction), resolution 0.01 m/s / 1°
Air TemperaturePt100, −35°C to +70°C, ±0.1°C accuracy, 0.1°C resolution
Relative HumidityRotronic HygroClip probe, 0–100% RH, ±0.8% RH @23°C, 0.1% RH resolution
Atmospheric PressureBarometric sensor, 600–1100 hPa, ±0.5 hPa, 0.1 hPa resolution
Dew Point TemperatureCalculated, ±0.15°C accuracy @23°C ambient / 20°C dew point, 0.1°C resolution
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVaisala
OriginFinland
ModelPWD22
Visibility Measurement Range (MOR)10–20,000 m
Accuracy±10% (10 m–10 km), ±15% (10–20 km)
Precipitation Detection Sensitivity≤0.05 mm/h (within 10 min)
Operating Temperature−40 °C to +60 °C
Power Supply12–50 VDC (electronics)
Power Consumption2 W (standard), 65 W (with heater)
Output InterfaceRS-232 / RS-485
Dimensions40.4 × 69.5 × 19.9 cm
Weight3 kg
Ingress ProtectionIP66
EMC ComplianceCISPR 16-1/-2, IEC 61000-4-2/-3/-4/-5/-6
Weather Type Recognition7 precipitation types (rain, freezing rain, drizzle, freezing drizzle, rain/snow mix, snow, sleet), fog, haze (smoke, dust), clear sky
Reporting StandardsWMO FM-12 (SYNOP), FM-15 (METAR), NWS code tables
Precipitation MeasurementIntensity, accumulation, new snow depth estimation
Optical PrincipleForward scatter
Calibration ReferenceCertified atmospheric transmissometer traceable to national standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBelfort (USA)
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelModel 6000
PriceUSD 9,200 (FOB US Port)
Discontinued — Replacement ModelModel 6400
Measurement PrincipleForward Scatter (42° scattering angle)
Range6 m to 80 km
Accuracy±10% or ±3 m (whichever greater)
Light SourceHigh-output infrared LED
Analog Outputs0–1 V, 0–5 V, 0–10 V, 4–20 mA
Alarm Outputs2-channel TTL (user-configurable thresholds)
Digital InterfaceRS-232 / RS-422, 300–38,400 baud
Operating Temperature−40 °C to +55 °C
Relative Humidity0–100 % RH
Power Supply110 VAC / 220–240 VAC / 12 VDC
Power Consumption12 W (standard), 17 W (with Ambient Light Sensor), 25 W (with heated shroud)
Dimensions978 mm × 343 mm × 425 mm
Weight8.75 kg
MountingU-bolt bracket
Max Wind Speed Tolerance60 m/s
Housing MaterialCorrosion-resistant aluminum alloy
Lens HeaterStandard
Optional Heated ShroudAvailable (Part No. 96916-01)
Calibration KitOptional (Part No. 90001)
ComplianceCE Marked
FCC Compliance47 CFR Part 15
Environmental CertificationIP65 equivalent
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHukseflux
OriginNetherlands
ModelSR20
Calibration TraceabilityWorld Radiometric Reference (WRR)
ISO 90602018 Classification: Secondary Standard
Measurement Range0–4000 W/m²
Spectral Range285–3000 nm
Sensitivity15 × 10⁻⁶ V/(W/m²)
Calibration Uncertainty< 1.2 % (k = 2)
Zero Offset (a)< 5 W/m² (unventilated), 2.5 W/m² (with VU01 ventilation unit)
Operating Temperature−40 to +80 °C
Temperature Response< ±1 % (−10 to +40 °C)
Directional Response ReportIncluded
Temperature Dependence CharacterizationIndividual quadratic polynomial provided per unit
Heating Power1.5 W @ 12 VDC
Output SignalAnalog voltage (mV)
Supply Voltage8–30 VDC
Integrated Temperature SensorPt100 or 10 kΩ thermistor
Cable Length5 m (extendable in 5-m increments)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelST850
OutputNMEA 2000® or Analog (selectable)
Speed Range2–45 knots (2–52 MPH)
Temperature Accuracy±0.5°C
Operating Temp−10°C to +40°C
Sampling Interval1 s
Pressure Rating3 m
Transducer Window MaterialPolyurethane
Hull Tilt Limit≤22°
Pulse Frequency17,000 p/nm (4.8 Hz per knot)
Supply Voltage9–16 VDC
Current Draw<200 mA
NMEA 2000 LEN2
ComplianceIEC 60945
Weight (Plastic/Bronze/Stainless)0.7 / 1.3 / 1.6 kg
Standard Cables6 m NMEA 2000, 9 m Analog
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelUST850
Output ProtocolsNMEA 0183, NMEA 2000®
Speed Range0.1–50 knots
Operating Temperature−4 to 40 °C
Transmit Frequency4.5 MHz
Pulse Repetition Frequency0.5–12 kHz (adaptive)
Supply Voltage9–16 VDC
Average Current Draw125 mA @ 12 VDC
Housing MaterialPlastic / Bronze / Stainless Steel
Through-Hull Diameter51 mm
Weight1.4 kg (plastic), 1.8 kg (bronze)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVaisala
OriginFinland
ModelWXT534
Instrument TypePortable Weather Station
Temperature Range−52 to +60 °C
Relative Humidity Range0–100 %RH
Atmospheric Pressure Range600–1100 hPa
Temp. Resolution0.1 °C
RH Resolution0.1 %RH
Pressure Resolution0.1 hPa
Temp. Accuracy±0.3 °C @ 20 °C
RH Accuracy±3 %RH (0–90 %RH), ±5 %RH (90–100 %RH)
Pressure Accuracy±0.5 hPa (0–30 °C)
Output OptionsSDI-12 v1.3, RS-232, RS-485, RS-422
Communication ProtocolsASCII auto/polling, NMEA 0183 v3.0
Power Supply6–24 VDC
Avg. Current Consumption0.1 mA (SDI-12 standby), 3 mA (typical, default interval), 15 mA (max, continuous measurement)
Heater Supply12–24 VDC / 12–17 VAC
Heater Current0.8 A @ 12 VDC, 0.4 A @ 24 VAC
Enclosure RatingIP65 (without mounting adapter), IP66 (with mounting adapter)
Operating Temp.−52 to +60 °C
Storage Temp.−60 to +70 °C
Weight<1.2 kg
DimensionsØ140 × 200 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginUSA
ModelD-50
Measurement ParameterspH, Temperature, ORP, Conductivity (D-54), Dissolved Oxygen (D-55), Ion Selective Electrode (ISE) capability (D-53)
Enclosure RatingIP67
Power SupplyDC 3 V (LR6 batteries)
Weight300–330 g
InterfaceRS-232C for PC/printer connectivity
DisplayBacklit LCD with dual-channel readout
Data LoggingAutomatic storage with timestamp
Self-Diagnostic FunctionYes
Electrode CompatibilityRuggedized waterproof pH/ORP probes, interchangeable sensor modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGill
OriginUnited Kingdom
ModelWindObserver II
Instrument TypeUltrasonic Anemometer
Resolution0.01 m/s
Measurement Range0–65 m/s
Accuracy±2% of reading
Operating Temperature−55 °C to +70 °C
Operating Humidity5–100% RH
Ingress ProtectionIP66
Housing MaterialStainless Steel
CertificationLloyds Register Type Approved
Output Interfaces1 digital (RS-422/RS-485), 3 analog (4–20 mA or 0–10 V)
WMO ComplianceWind averaging and gust algorithms aligned with WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008)
Optional FeatureIntegrated de-icing system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGill
OriginUnited Kingdom
ModelGMX500
TypePortable Weather Station
ComplianceWMO-compliant measurement architecture
Sensor TechnologyUltrasonic wind sensing, passive ventilated radiation shield, integrated barometric/thermohygrometric module
Communication InterfacesRS-232 / RS-422 / RS-485 (ASCII), SDI-12, NMEA 0183, MODBUS RTU, optional analog outputs
Optional ModulesGPS receiver (for true wind calculation, georeferenced timestamping, sunrise/sunset, solar position, MSL pressure correction)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRainWise
OriginUSA
ModelPVmet 330
Sensor TypesGlobal Solar Irradiance, PV Module Backsheet Temperature (up to 2), Air Temperature, Relative Humidity, Barometric Pressure, Wind Speed & Direction, Precipitation
CommunicationRS-485 Modbus RTU (standard), Optional Modbus TCP over Ethernet
ComplianceSunSpec Certified
Operating Temperature-40 °C to +60 °C
Power Supply10–30 VDC, 50 mA
Enclosure MaterialsPVC, ABS, Anodized Aluminum, Stainless Steel, Polycarbonate (LEXAN®/Makrolon® 2658)
Weight9.07 kg
Dimensions (L×W×H)91.44 × 50.8 × 33.02 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRainWise
OriginUSA
ModelMK-III-LR
Instrument TypePortable Weather Station
Wireless Frequency2.4 GHz ISM Band
Max Line-of-Sight Transmission Distance1600 m
Wind Speed Range0–67 m/s
Wind Speed Accuracy±2% FS
Wind Direction Accuracy±3°
Temperature Range−54 to +74 °C
Temp Accuracy±0.5 °C
Relative Humidity Range0–100% RH
RH Accuracy±2% (−40 to +85 °C)
Barometric Pressure Range300–1100 hPa
Pressure Accuracy±0.5 hPa @ 25 °C (temp-compensated)
Rainfall Resolution0.25 mm
Solar-Powered Battery Runtime60 days without sunlight
NIST-Traceable CalibrationYes
Enclosure MaterialsStainless steel, fiberglass, UV-stabilized PVC
Mounting OptionsTripod or Mono mounting bracket
ComplianceFCC Part 15, IC RSS-247, CE RED Directive (EU variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRMAR
OriginUSA
Model110WXS
TypePortable Weather Station
Measurement PrincipleUltrasonic Wind Sensing, Capacitive Humidity & Thermistor Temperature Sensing, Piezoresistive Barometric Pressure Sensing
Communication InterfaceRS-232 or RS-422
ComplianceIP66 Enclosure Rating, NEMA 4X Equivalent
Operating Temperature Range–40 °C to +70 °C
Power Supply9–36 V DC
Dimensions24.1 × 15.2 × 12.7 cm (L×W×H)
Weight1.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHukseflux
OriginNetherlands
ModelSR30-M2-D1
Spectral Range285–3000 nm
Calibration Uncertainty<1.2 % (k=2)
Measurement Range–400 to +4000 W/m²
Zero Offset<2 W/m²
Response Time (95%)4 s
Operating Temperature–40 to +80 °C
Temperature Response<±0.4 % (–30 to +50 °C)
Tilt Sensor Accuracy±1° (0–90°, –30 to +50 °C)
Power Consumption<3 W @ 12 VDC (heated/ventilated mode)
OutputModbus RTU over 2-wire RS-485
Cable Length5 m (standard)
ComplianceISO 9060:2018 Spectrally Flat Class A, IEC 61724-1:2017 Class A & B, WMO Performance Level I
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGILL
OriginUnited Kingdom
ModelWindObserver 70
Instrument TypeUltrasonic Anemometer
Resolution0.01 m/s
Measurement Range0–75 m/s
Accuracy±2% of reading
Operating Temperature−55°C to +70°C
Operating Humidity0–100% RH
Heating Power150 W (1 W/cm²)
Electrical Input7 A @ 24 VAC/DC
Wind Direction Range0–360° (dead-zone-free)
CalibrationNIST-traceable
Enclosure MaterialStainless steel
Ingress ProtectionIP66
ComplianceFAA AC 150/5220-9C, UK CAA CAP 744, ICAO Annex 3, WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No.8, 7th ed., 2008)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNK
OriginUSA
ModelKestrel 5400AG
Instrument TypeHandheld Weather Station
IP RatingIP67 (Dust-tight & Waterproof to 1m for 30 min)
PowerSingle AA battery (alkaline or lithium)
DisplayHigh-resolution, dual-color backlight LCD
Data Logging Capacity>10,000 timestamped records
Wireless ConnectivityBluetooth Low Energy (BLE) via Kestrel LiNK iOS/Android app
PC ConnectivityUSB cable or optional Kestrel LiNK Dongle (Windows/macOS)
ComplianceMeets ASTM E1982-22 (Standard Guide for Assessing Heat Stress in Livestock), ISO 7243 (Hot Environments — Estimation of the Heat Stress on Working Man), and ASABE EP470.4 (Environmental Stress Indices for Cattle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRainWise
OriginUSA
ModelEDL-WS
Instrument TypePortable Weather Station
Data Logger Memory Options128K / 256K / 512K / 1M (up to 2M optional)
Power Supply6 VDC, AC/DC adapter or solar panel compatible
Display2-line × 16-character LCD
Communication InterfaceRS232 standard, optional Ethernet, GPRS/CDMA, or wireless modules
Sampling Interval1, 5, 10, 15, 20, 30, or 60 minutes
Input Channels8 single-ended or 4 differential analog inputs + 3 digital inputs
Output OptionsRS232, optional 4–20 mA or 0–1 V analog outputs
Real-Time ClockIntegrated, battery-backed
Backup Battery Life10 years
Dimensions (Data Logger)19.5 × 10 × 4 cm
Enclosure RatingIP67 (Monopod mounting bracket)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRainWise
OriginUSA
ModelPVmet75
Instrument TypePV-Specific Meteorological Monitoring System
Communication InterfaceRS-485 Modbus RTU (standard), optional Modbus TCP via Ethernet
Solar Irradiance Range0–1750 W/m², Accuracy: ±5%, Resolution: 1 W/m²
Cosine Response Error±1% at 45°, ±5% at 75°
Air Temperature Range−40 to +80 °C, Accuracy: ±0.3 °C, Resolution: 0.1 °C, Thermal Time Constant: 30 s
Backsheet Temperature Range−40 to +80 °C, Accuracy: ±0.3 °C, Resolution: 0.1 °C, Thermal Time Constant: 270 s
Operating Ambient−40 to +60 °C, 0–100% RH
Power Supply10–30 VDC, 50 mA
Cable Length7.62 m
Enclosure MaterialsPVC, ABS, Anodized Aluminum, Stainless Steel, LEXAN®, Makrolon® 2658
Dimensions (L×W×H)58.42 × 25.4 × 20.32 cm
Weight2.26 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETONE
OriginUSA
ModelBAM-1020
Measurement MethodBeta Ray Attenuation
Measured ParametersPM10, PM2.5
EPA CertificationEQPM-0798-122 (PM10 FEM), EQPM-0308-170 (PM2.5 Class III FEM)
ComplianceCE, NRC, TÜV, CARB, ISO 9001
Range0–1000 µg/m³ (configurable up to 10,000 µg/m³)
Detection Limit<1.0 µg/m³ (24-hr), <4.8 µg/m³ (1-hr)
Flow Rate16.7 L/min (adjustable 0–20 L/min)
FilterGlass fiber tape, 30 mm × 21 m per roll
Beta Source¹⁴C, 60 µCi ±15 µCi (t₁/₂ = 5730 yr)
Data Storage182 days of hourly records
Operating Temp–30 °C to +60 °C
RH ControlInternal heater, 10–99% RH setpoint
Power100–230 VAC, 50/60 Hz, <0.4 kW
Dimensions31 cm (H) × 43 cm (W) × 40 cm (D)
Weight24.5 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0