Empowering Scientific Discovery

Shanghai Baineng Instrumentation & Metering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41502
MaterialUV-stabilized white thermoplastic housing, anodized aluminum support frame, stainless steel mounting hardware
Dimensions20 cm (diameter) × 33 cm (height)
Net Weight1.1 kg
Shipping Weight~2.7 kg
Power Supply12–14 VDC @ 500 mA
Airflow Rate5–11 m/s (16–35 ft/s), dependent on sensor power draw
Radiative Error (Temperature)≤0.2 °C RMS at 1000 W/m² solar irradiance
Delta-T Error≤0.05 °C RMS under identical shielding exposure
Fan Lifetime>80,000 hours continuous operation at 25°C
Sensor CompatibilityRTD-based temperature probes (e.g., 41342), combined RH/T probes (e.g., 41382)
Output Options4–20 mA or 0–1 VDC
Operating EnvironmentOutdoor, all-weather, low-wind-speed microclimates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
Model33-627-02
Measurement Range10–95% RH
Accuracy±5% RH
Resolution1% RH
IP Rating (when installed)IPX4
Compatible SystemsAirmar 110WX, 120WX, 150WX, 200WX, 220WX Weather Stations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41342
Measurement Range−50 to +50 °C
Accuracy (at 0 °C)±0.3 °C (standard), ±0.1 °C (optional)
Time Constant42 s (with 43408 radiation shield)
Sensor Type1000 Ω Pt RTD, 4-wire configuration
Output OptionsResistance (41342), 0–1 VDC (41342VC), 4–20 mA (41342LC)
CalibrationSelectable °C or °F
Recommended Radiation Shield43502 (aspirated) or 41003P (multi-plate passive)
Recommended Cable2-pair shielded, 22 AWG (P/N 18641)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41382VC
Temperature Range-50 to +50 °C
Temperature Accuracy±0.3 °C @ 23 °C
Temperature Resolution0.1 °C
Relative Humidity Range0–100 %RH
RH Accuracy±1 %RH @ 20 °C
RH Stability<1 %RH/year
Response Time (with radiation shield)10 s
Output Signal0–1 VDC or 0–5 VDC (jumper-selectable)
Power Supply12–30 VDC
Operating Ambient Temperature-50 to +50 °C
DimensionsØ64 mm × 176 mm
Weight200 g
Sensor Type (Temp)Platinum RTD (Pt1000)
Sensor Type (RH)Rotronic Hygromer® capacitive polymer
Recommended Cable5-conductor shielded (Young P/N 18723)
Optional Radiation Shields43502 (aspirated), 41003P (multi-layer passive)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41342VC
Output Signal0–1 VDC
Sensor TypePt1000 RTD (4-wire)
Measurement Range−50 to +50 °C
Accuracy @ 0 °C±0.3 °C (standard), ±0.1 °C (optional)
Time Constant42 s (with Model 43408 radiation shield)
Calibration Options°C or °F
EnclosureWeatherproof terminal housing
Recommended Radiation ShieldModel 43502 (aspirated) or Model 41003P (multi-plate passive)
Recommended Cable2-pair shielded, 22 AWG (e.g., Part #18641)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVaisala
OriginFinland
ModelHMP60
Temperature Range−40 to +60 °C
Temperature Accuracy±0.6 °C (full range), ±0.5 °C (10–30 °C)
Temperature Resolution0.1 °C
Relative Humidity Range0–100 %RH
RH Accuracy±3 %RH (0–90 %RH, 0–40 °C), ±5 %RH (90–100 %RH, 0–40 °C)
Dew Point Range−40 to +60 °C
Dew Point Accuracy±2 °C (ΔT ≤ 15 K, 0–40 °C), ±3 °C (ΔT ≤ 15 K, −40–0 °C & 40–60 °C)
Output OptionsDual analog voltage (0–1 V, 0–2.5 V, 0–5 V, or 1–5 V DC), optional RS485 (Modbus RTU), optional 4–20 mA loop-powered output
Supply Voltage5–28 VDC (8–28 VDC with 5 V auxiliary output)
Typical Current Consumption1 mA (average), 5 mA (peak)
Warm-up Time2 s (analog), 1 s (digital)
Enclosure MaterialAISI 316 stainless steel housing, chrome-plated ABS grille filter (optional stainless steel filter)
IP RatingIP65
Mechanical InterfaceM12×1 thread, 10 mm depth
Connector4-pin M8 (IEC 60947-5-2)
Dimensions71 mm × Ø12 mm
Weight23 g (with 0.3 m cable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNK
OriginUSA
ModelDROP D2AG
Channel CountMulti-channel
IP RatingIP67 (30-min submersion)
Drop ResistanceMIL-STD-810G (1 m drop)
Operating Range–10°C to 55°C (14°F to 131°F)
Temperature Accuracy±0.5°C (±0.9°F)
Humidity SensingCapacitive Polymer Sensor
BatteryCR2032 Lithium Coin Cell (up to 4 months typical life)
Memory Capacity>7,000 temperature/humidity data points
Wireless ProtocolBluetooth® 4.0 Low Energy (BLE)
Max Wireless Range30 m (100 ft) line-of-sight
Dimensions24 × 46 × 60 mm
Weight34 g
Calculated IndicesHeat Stress Index (HSI), Dew Point Temperature, Temperature-Humidity Index (THI)
ComplianceRoHS, FCC Part 15, IC RSS-247
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41003
Dimensions12 cm (D) × 27 cm (H)
Weight (net)0.7 kg
MountingU-bolt clamp for masts up to 2 inches (50.8 mm) diameter
Sensor compatibility41003 — up to 16 mm diameter
Radiative error (at 1080 W/m² solar irradiance)≤0.4 °C RMS @ 3 m/s wind speed
Housing materialUV-stabilized white thermoplastic with high-reflectivity, low-thermal-conductivity disk
ComplianceDesigned per WMO Guide to Meteorological Instruments and Methods of Observation (CIMO Guide), ISO 4690:2022 (Environmental monitoring — Performance requirements for radiation shields), ASTM D7237-21 (Standard Practice for Evaluation of Radiation Shields for Air Temperature Sensors)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVaisala
OriginFinland
ModelHMP110
Temperature Range−40 to +80 °C
Temperature Accuracy±0.2 °C (0–40 °C), ±0.4 °C (−40–0 °C & 40–80 °C)
Relative Humidity Range0–100 %RH
RH Accuracy±1.7 %RH (0–90 %RH, 0–40 °C), ±2.5 %RH (90–100 %RH, 0–40 °C)
Resolution0.1 °C / 0.1 %RH
Power Supply5–28 VDC
Output OptionsDual analog (0–1 V, 0–2.5 V, 0–5 V, or 1–5 V DC), optional RS485 digital interface
IP RatingIP65
Housing MaterialStainless steel (AISI 316)
Sensor TypeVaisala HUMICAP® 180R (humidity), Pt1000 RTD Class F0.1 (temperature)
Dimensions71 mm × Ø12 mm
Weight23 g
Warm-up Time≤4 s (analog), ≤1 s (digital)
EMC ComplianceEN 61326-1
CalibrationTraceable to NIST-equivalent standards, supplied with ISO/IEC 17025-accredited calibration certificate
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNK
OriginUSA
ModelDROP D3
Channel CountMulti-channel
Dimensions6 × 4.5 × 2.3 cm
MountingWall-mountable
IP RatingIP67
Weight34 g
Bluetooth RangeUp to 30 m (100 ft) line-of-sight
Logging IntervalConfigurable from 2 sec to 12 hr
Battery LifeUp to 3 months (typical use, 1-min interval)
Memory Capacity16,384 data points per sensor
Operating Temperature–20 °C to 60 °C
Relative Humidity Range0–100 % RH (non-condensing)
Pressure Range300–1100 hPa
Accuracy (Temp)±0.5 °C (–10 to 50 °C)
Accuracy (RH)±3 % RH (20–80 % RH)
Accuracy (Pressure)±1.5 hPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDavis Instruments (USA)
OriginUSA
Model6382
Channel CountMulti-channel (up to 8 stations per console)
Operating Temperature–40 °C to +65 °C
Storage Temperature–45 °C to +70 °C
RH Range1–100% RH
RH Accuracy±3% (0–90% RH), ±4% (90–100% RH)
RH Resolution1% RH
RH Drift≤±2%/year
Temperature Range–40 °C to +65 °C
Temp Accuracy±0.5 °C
Temp Resolution0.1 °C
Update Interval10 s (temp), 50 s (RH)
Radio Frequency868.0–868.6 MHz
Transmit Power~8 mW
Line-of-Sight Rangeup to 300 m
Obstructed Range60–120 m
BatteryCR123 3 V lithium (8-month typical life)
Enclosure MaterialUV-stabilized PVC
Dimensions (Station)190 × 216 × 153 mm
Weight (Station)1.6 kg
Data Logging Memory128 KB non-volatile
Max Stored Records2560
Sampling Intervals1, 5, 10, 15, 30, 60, or 120 min
Console CompatibilityVP2 Console or Envoy Data Logger
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNK
OriginUSA
ModelDROP D2
Channel CountMulti-Channel
IP RatingIP67 (30-min submersion)
Drop ResistanceMIL-STD-810G (1 m drop)
Operating Range–10°C to +55°C (14°F to 131°F)
Temp Accuracy±0.5°C (±0.9°F)
Sensor TypeExternal-sealed thermistor & humidity sensor with thermal isolation
BatteryCR2032 lithium coin cell (up to 4 months typical life)
Memory Capacity>7,000 combined temperature/humidity data points
Wireless ProtocolBluetooth® 4.0 (BLE)
Max Bluetooth Range100 ft (30 m, line-of-sight)
Dimensions24 × 46 × 60 mm (1 × 1.8 × 2.4 in)
Weight34 g (1.2 oz)
App CompatibilityKestrel LiNK for iOS 6+ (iPhone 4s or newer, iPad 3rd gen+, iPod Touch 5th gen+) and Android 4.3+ with Bluetooth Smart® support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNK
OriginUSA
ModelDROP D3FW
Channel CountMulti-channel
Dimensions60 × 46 × 24 mm (2.36 × 1.81 × 0.94 in)
MountingWall-mountable with integrated D-ring
Enclosure MaterialEngineering-grade ABS plastic
Ingress ProtectionIP67
Shock ResistanceMIL-STD-810G compliant
Weight34 g (1.2 oz)
Wireless RangeUp to 30 m (100 ft) line-of-sight via Bluetooth® 4.0+
Logging IntervalConfigurable from 2 seconds to 12 hours
Memory CapacityUp to 13,000 data points per parameter
Battery LifeUp to 3 months (typical use, 1-min interval)
Operating Temperature–20 °C to 60 °C (–4 °F to 140 °F)
Relative Humidity Range5–95 %RH (non-condensing)
Pressure Range300–1100 hPa (mbar)
Accuracy (Temp)±0.5 °C (±0.9 °F) @ 25 °C
Accuracy (RH)±3 %RH @ 20–80 %RH
Accuracy (Pressure)±1.5 hPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41382LC2
Temperature Range-50 to +50 °C
Temperature Accuracy±0.3 °C (@ 23 °C)
Temperature Resolution0.1 °C
Relative Humidity Range0–100 %RH
RH Accuracy±1 %RH (@ 20 °C)
RH Stability<1 %RH/year
RH Response Time10 s (unshielded)
Temperature Response Time10 s (unshielded)
Output Signal4–20 mA (2-wire loop-powered)
Supply Voltage12–30 VDC
Max Current Draw46 mA
Sensor TypePt100 RTD (temperature), Rotronic Hygromer® (humidity)
Enclosure DimensionsØ64 mm × 176 mm
Weight200 g
Recommended Cable2-pair shielded, 22 AWG
Optional Radiation ShieldModel 43502 (aspirated) or Model 41003P (multi-plate)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDavis Instruments
OriginUSA
Model6420
Sensor TypeArtificial Leaf Resistive Sensor
Excitation Voltage3 V (nominal, bipolar)
Time Constant2 s
Cable Length12 m
Cable Specification4-conductor, 26 AWG
ConnectorStandard RJ-11
Substrate MaterialFiberglass + Ceramic Board
Conductive Grid MaterialCopper, Nickel, Gold
Mounting BracketAnodized Aluminum
Dimensions (L×W×H)102 mm × 58 mm × 58 mm
Weight0.4 kg
Output Range0–15 (dimensionless wetness index)
Accuracy±0.5 units
Resolution1 unit
Data Update Interval62.5–75 s
ComplianceDesigned for outdoor agricultural and ecological monitoring per ASTM E2797-21 (Standard Practice for Measuring Leaf Wetness Duration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNK
OriginUSA
ModelDROP D1
Channel CountSingle-Channel
IP RatingIP67 (30-min submersion)
Drop ResistanceMIL-STD-810G (1 m drop)
Operating Range–10°C to +55°C (14°F to 131°F)
Accuracy±0.5°C (±0.9°F)
Sensor TypeExternally mounted, thermally isolated precision thermistor
BatteryCR2032 lithium coin cell (typical 4-month life)
Memory Capacity>13,000 temperature readings
Dimensions24 × 46 × 60 mm (1 × 1.8 × 2.4 in)
Weight34 g (1.2 oz)
Wireless ProtocolBluetooth® Low Energy (BLE)
Max Wireless Range30 m (100 ft) line-of-sight
Data RetrievalReal-time and historical via Kestrel LiNK mobile app (iOS/Android)
Logging IntervalConfigurable (down to 2 s)
Time SyncAutomatic upon BLE connection
ComplianceRoHS, FCC Part 15, IC RSS-247
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNK
OriginUSA
ModelDROP D2HS
Temperature Range-10 to 55°C
Temperature Accuracy±0.5°C
Resolution0.1°C
Operating Environment-18°C to 60°C
Power SupplyUser-replaceable CR2032 coin cell
Dimensions6 × 4.5 × 2.3 cm
Weight34 g
IP RatingIP67 (30-min submersion)
Shock ResistanceMIL-STD-810G (1 m drop)
Data Capacity>7,000 temperature/humidity records
Battery LifeUp to 4 months (typical use)
Wireless RangeUp to 30 m (100 ft) via Bluetooth® 4.0+
Computation CapabilitiesHeat Stress Index (HSI), Dew Point Temperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCampbell
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSI-111
Instrument TypeFixed-Mount Infrared Radiometer
Measurement Range-40 to 70°C
Accuracy±0.2°C (-10 to 65°C), ±0.5°C (-40 to 70°C)
Consistency±0.1°C (-10 to 65°C), ±0.3°C (-40 to 70°C)
Repeatability±0.05°C (-10 to 65°C), ±0.1°C (-40 to 70°C)
Spectral Response8–14 µm
Field of View22° half-angle
Response Time<1 s
Operating Environment-55 to 80°C, 0–100% RH
Excitation Voltage2.5 VDC
Thermopile Output60 µV/°C (ΔT between target and sensor body)
Thermistor Output0–2500 mV
Signal ChannelsOne differential (thermopile), one single-ended (thermistor)
Dimensions2.3 cm (diameter) × 6 cm (length)
Weight190 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVaisala
OriginFinland
ModelHMP155
Temperature Range-80 to +60 °C
Temperature Accuracy±0.2 °C (at 20 °C, Pt1000 F0.1 per IEC 60751)
Relative Humidity Range0–100 %RH
RH Accuracy±1 %RH (15–25 °C, 0–90 %RH)
Resolution0.1 °C / 0.1 %RH
Operating Voltage7–28 VDC
Output Options0–1 V, 0–5 V, 0–10 V, RS485, Pt100 (4-wire)
Probe Dimensions267 mm × Ø40 mm
Weight86 g
Enclosure RatingIP66
Sensor ProtectionSintered PTFE Filter
Heating FunctionOptional continuous probe heating (XHEAT)
Chemical PurgeOptional
EMC ComplianceEN 61326-1 (Industrial Environment)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelAZ8829
Channel CountSingle-Channel
Temperature Range−40 to 85 °C (−40 to 185 °F)
Temp Accuracy±0.6 °C (−20 to 50 °C), ±1.2 °C (−40 to −20 °C and 51 to 85 °C)
Temp Resolution0.1 °C / 0.1 °F
RH Range0–100% RH
RH Accuracy±3% RH
RH Resolution0.1% RH
Memory Capacity16,000 data sets
Sampling Interval1 second to 2 hours
Display4-digit LCD with unit indicators (°C/°F/%RH/AL-H/AL-L)
InterfaceRS232 (9600 baud), IRDA
Power3.6 V Li battery (½AA, 1.2 Ah), ~2-year life
Dimensions80 × 55 × 22 mm
Weight26 g
EnclosureIP65-rated waterproof and abrasion-resistant housing
AlarmDual-color LED (red = out-of-limit alert
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDavis
Model6345
OriginUSA
Instrument TypeWireless Soil Moisture and Temperature Monitoring System
Operating Temperature (Host)−40 °C to +65 °C
Storage Temperature−45 °C to +70 °C
Power SupplyCR123A 3 V Li battery + 0.5 W solar panel
Battery Life8 months (no sun), up to 2 years (typical insolation)
Wireless Rangeup to 300 m (line-of-sight), 75–150 m (obstructed)
Radio Frequency868.0–868.6 MHz, 8 channels, ~8 mW output
Soil Moisture Sensor (6440)Resistive type, 0–200 cbar range, 1 cbar resolution, 4.6 m standard cable (extendable to 30 m)
Soil Temperature Sensor (6470)Thermistor-based, −40 °C to +65 °C, ±0.5 °C accuracy, 1 °C resolution, 4.6 m standard cable (extendable to 244 m on 22 AWG)
Data LoggingNon-volatile RAM + optional SD card storage
DisplayBacklit LCD console (151 × 86 mm active area)
Mounting Mast1 m galvanized steel tube, Ø33 mm
Host Dimensions158.75 × 57.15 × 200 mm
Host Weight0.49 kg (battery included, sensors excluded)
Console Dimensions270 × 156 × 41 mm
Console Weight0.85 kg (with batteries)
SoftwareWeatherLink v6.x (Windows/macOS), supports CSV export, time-series plotting, alarm thresholds, and multi-station aggregation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRainWise
OriginUSA
ModelTWD
Temperature Range0–50 °C
Accuracy±0.15 °C
Resolution0.10 °C
Sensor TypePrecision Thermistor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelHT200
Temperature Range0–30°C
Accuracy±0.3°C
Resolution0.01°C
Response Time0.15 s
Output ProtocolNMEA 2000®
Update Rate2 Hz
Supply Voltage9–50 VDC
Current Draw≤30 mA
Cable Length6 m
Housing CompatibilityP17, B17, SS577
Mounting Hole Diameter51 mm
NMEA 2000 LEN1
Weight (Bronze)1.3 kg
Weight (Stainless Steel)1.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelB17-HP
Temperature Accuracy±0.3°C
Temperature Resolution0.01°C
Response Time Constant5 s
Operating Temperature Range0–30°C
Supply Voltage6–28 VDC
Max Current Draw30 mA
Output ProtocolsNMEA 0183 / NMEA 2000®
Output SentenceYXMTW (NMEA 0183), PGN 130310 (NMEA 2000®)
Mounting Hole Diameter51 mm
Housing Material OptionsBronze, Stainless Steel, Plastic
Profile Height5 mm
Cable Length (Max)100 m
Weight1.3 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0