BrandMETONE
OriginUSA
ModelBAM-1020
Measurement MethodBeta Ray Attenuation
Measured ParametersPM10, PM2.5
EPA CertificationEQPM-0798-122 (PM10 FEM), EQPM-0308-170 (PM2.5 Class III FEM)
ComplianceCE, NRC, TÜV, CARB, ISO 9001
Range0–1000 µg/m³ (configurable up to 10,000 µg/m³)
Detection Limit<1.0 µg/m³ (24-hr), <4.8 µg/m³ (1-hr)
Flow Rate16.7 L/min (adjustable 0–20 L/min)
FilterGlass fiber tape, 30 mm × 21 m per roll
Beta Source¹⁴C, 60 µCi ±15 µCi (t₁/₂ = 5730 yr)
Data Storage182 days of hourly records
Operating Temp–30 °C to +60 °C
RH ControlInternal heater, 10–99% RH setpoint
Power100–230 VAC, 50/60 Hz, <0.4 kW
Dimensions31 cm (H) × 43 cm (W) × 40 cm (D)
Weight24.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUNITEC
OriginItaly
ModelETL-BUS
PollutantsSO₂, H₂S, NH₃, C₆H₆, VOCs, CO, NO₂, O₃, CH₄, CO₂
PM MeasurementPM₁, PM₂.₅, PM₁₀
Sensor TechnologiesTF-MOS (Metal Oxide Semiconductor), Electrochemical (EC), NDIR (Infrared), Orthogonal Light Scattering (PM), OPC (Optical Particle Counter)
Operating Temperature−20 to +50 °C
Humidity Range10–95% RH (non-condensing)
IP RatingIP55
Power Supply12 VDC (with internal battery & 220 V AC adapter)
Power Consumption50–70 W
Dimensions1400 × 900 × 400 mm
Weight20 kg
ComplianceEU Directive 2008/50/EC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUNITEC
OriginItaly
ModelETL-One
Pollutants MeasuredSO₂, H₂S, CO₂, VOC, NH₃, C₆H₆, PM₁, PM₂.₅, PM₁₀
Sensor TechnologiesTF-MOS (metal oxide semiconductor), Electrochemical (EC), Non-Dispersive Infrared (NDIR), Orthogonal Light Scattering (for PM), Optical Particle Counting (OPC)
Operating Temperature−20 °C to +50 °C
Humidity Range10–95% RH (non-condensing)
Enclosure RatingIP55
Power Options220 VAC / 110 VAC / 12 VDC
Typical Power Consumption50–70 W
Dimensions540 × 710 × 310 mm
Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUNITEC
OriginItaly
ModelSENS-IT
Detection PrinciplesTF-MOS (CO, NO₂, O₃, C₆H₆, CH₄) / EC (NH₃, SO₂, H₂S, VOC) / IR (CO₂)
Measurement RangeCO: 0.1–80 ppm
NO₂/O₃10–250 ppb
C₆H₆0.1–30 ppb
CH₄1–1,500 ppm
NH₃7–100 ppm
SO₂/H₂S5–10,000 ppb / 2–3,000 ppb
VOC0.6–25 ppm
CO₂10–5,000 ppm
Accuracy±0.2 ppm (CO), ±10 ppb (NO₂/O₃), ±0.3 ppm (NH₃), ±20 ppb (SO₂), ±15 ppb (H₂S), ±0.1 ppm (VOC), ±50 ppm (CO₂)
Resolution0.1 ppm / 1 ppb / 0.1 ppm as applicable
Output0–5 V analog + RS485 digital
Operating Temp−20 to +50 °C
Humidity10–95% RH (non-condensing)
Dimensions50 × 50 × 90 mm (H)
Weight~200 g
HousingAnodized aluminum alloy
Power+12 VDC
Onboard ControlDigital thermal regulation, fan speed control, linearization, parameter configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUNITEC
OriginItaly
ModelETL3000
Measured PollutantsSO₂, H₂S, CO, NH₃, VOC, C₆H₆, NO₂, O₃, CH₄, CO₂
Sensor TechnologiesTF-MOS (Thick-Film Metal Oxide Semiconductor), Electrochemical (EC), Non-Dispersive Infrared (NDIR)
Operating Temperature−20 to +50 °C
Humidity Range10–95 % RH (non-condensing)
Enclosure RatingIP55
Dimensions370 × 522 × 210 mm
Weight10 kg
Power Options220 VAC / 110 VAC / 12 VDC
Max Power Consumption30 W
Data Logging1 Hz sampling, 15- or 60-min averaging, internal flash storage
CommunicationRS232 ASCII output, optional GSM/UMTS modem (VPN-capable)
Optional Add-onsIntegrated meteorological station, Class 1 noise monitor, solar power kit (panel + battery + charge controller), heating module for particulate sampling line
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUNITEC
OriginItaly
ModelDUST-IT2
Measurement PrincipleOptical Light Scattering
Measured ParametersPM₁₀ / PM₂.₅
Measurement Range0–2000 µg/m³
Sampling Flow Rate2 L/min
Detection Limit1 µg/m³
Flow Stability95%
Operating Temperature−20 to +50 °C
Operating Humidity0–95% RH
Enclosure MaterialAnodized Aluminum
Dimensions (W×H×L)200 × 297 × 121 mm
Weight~4 kg
IP RatingIP33
Power Supply100–240 V AC, 0.7 A, 50–60 Hz (optional 12 V DC, 2.1 A)
Communication InterfacesRS485 (Modbus RTU), optional 4–20 mA output or integrated WLAN module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTISCH
OriginUSA
ModelTE-20-800
Sampling Flow Rate28.3 L/min
Aerodynamic Diameter Range>9.0 µm to <0.3 µm
Stage Count8 impactor stages + pre-separator
Filter Diameter81 mm
MaterialAnodized aluminum alloy body with silicone O-rings
ComplianceMeets US EPA, OSHA, ACGIH, and ISO 21501-4 referenced cascade impactor performance criteria
Collection EfficiencyHigh-fidelity inertial impaction with minimized particle bounce and re-entrainment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirMetrics
OriginUSA
ModelMiniVol TAS
Flow Range0–10 L/min
Pressure Capability>30,000 Pa
Flow Stability±5%
Max Flow Error±5%
Continuous Operation Time at Max Flow & Backpressure60 h
Dimensions (Sampler)25.4 × 30.5 × 17.8 cm
Weight (Fully Configured)4.45 kg
Battery14.8 V / 118 Wh Li-ion (≥60 h runtime, 5 h recharge)
Filter Format47 mm cassette (EPA FRM-compliant)
Inlet TypeEPA FRM-designated PM₁₀ or PM₂.₅ cyclonic separator
Power OptionsAC/DC adapter (100–240 VAC, 47–63 Hz) or solar-compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAeroQual
ModelAQM 60
Measurement PrincipleElectrochemical & Metal Oxide Semiconductor (MOS) Sensor Array
Gas ParametersO₃, NO₂, CO, SO₂, CO₂, VOCs
Particulate MonitoringPM₁₀ (optional PM₂.₅)
Meteorological ParametersTemperature, Relative Humidity, Wind Speed, Wind Direction, Noise
Data Logging IntervalConfigurable down to 2-minute sampling
Communication InterfacesGSM/GPRS/UMTS modem, Ethernet (LAN/WLAN), RS232
Calibration TraceabilityNIST-traceable gas standards
Enclosure RatingIP65-rated weatherproof housing
Onboard StorageInternal flash memory (≥16 GB)
Power Supply12–24 V DC or solar-compatible