- All
- Favorite
- Popular
- Most rated
| Brand | Campbell Scientific |
|---|---|
| Model | CR800 |
| Origin | USA |
| Differential Input Channels | 3 (6 single-ended) |
| Analog Input Resolution | 13-bit A/D |
| Scan Rate | Up to 100 Hz |
| Operating Temperature Range | 0 to 40 °C |
| Voltage Measurement Resolution | 0.33 µV |
| Sleep Mode Current Draw | ~0.6 mA |
| Active Current Draw (w/o RS-232) | 1–16 mA |
| Active Current Draw (w/ RS-232) | 17–28 mA |
| Communication Interfaces | 1 × CS I/O port, 1 × RS-232 serial port |
| Supported Protocols | PakBus®, Modbus RTU/ASCII, SDI-12, SDM, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP |
| Onboard Memory | 4 MB (data + program storage) |
| Data Format | Tabular ASCII |
| Operating System | PakBus OS |
| Compatible Software | LoggerNet, PC400, Short Cut |
| Optional Peripheral | CR1000KD handheld display |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | M265LM |
| Frequency Bands | Low Band 42–65 kHz (Beamwidth 25°–16°), Medium Band 85–135 kHz (Beamwidth 16°–11°) |
| Output Power | 1000 W |
| Installation Type | In-hull Mount |
| Housing Material | Polyurethane Encapsulated Plastic |
| Transducer Window | Polyurethane |
| Cable Length | 10 m |
| Integrated Temperature Sensor | Yes |
| Weight | 6.2 kg |
| Total Bandwidth | 73 kHz |
| Compatible Frequencies | 50 kHz, 88 kHz, 107 kHz |
| Hull Compatibility | Solid Fiberglass Hulls Only |
| Proprietary Technology | Xducer ID® |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | PG/H |
| Construction | Anodized aluminum housing, stainless steel components, low-surface-tension polymer tipping bucket |
| Heating | Integrated thermostatically controlled heater (activates below 1°C) |
| Switch Type | Reed switch |
| Output | Momentary closure pulse (< 0.1 s duration) |
| Resolution Options | 0.1 mm, 0.2 mm, or 0.25 mm per tip |
| Accuracy | ±0.5% at 12.5 mm/h rainfall rate |
| Dimensions | 21.9 cm diameter × 31.75 mm height |
| Compliance | Designed for continuous outdoor deployment in accordance with WMO Guide to Instruments and Methods of Observation (CIMO Guide), ISO 9060:2018 Class B performance expectations for precipitation measurement |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41502 |
| Material | UV-stabilized white thermoplastic housing, anodized aluminum support frame, stainless steel mounting hardware |
| Dimensions | 20 cm (diameter) × 33 cm (height) |
| Net Weight | 1.1 kg |
| Shipping Weight | ~2.7 kg |
| Power Supply | 12–14 VDC @ 500 mA |
| Airflow Rate | 5–11 m/s (16–35 ft/s), dependent on sensor power draw |
| Radiative Error (Temperature) | ≤0.2 °C RMS at 1000 W/m² solar irradiance |
| Delta-T Error | ≤0.05 °C RMS under identical shielding exposure |
| Fan Lifetime | >80,000 hours continuous operation at 25°C |
| Sensor Compatibility | RTD-based temperature probes (e.g., 41342), combined RH/T probes (e.g., 41382) |
| Output Options | 4–20 mA or 0–1 VDC |
| Operating Environment | Outdoor, all-weather, low-wind-speed microclimates |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | B164 |
| Operating Frequencies | 50 kHz / 200 kHz |
| Beamwidth | 22° × 20° @ 50 kHz |
| Output Power | 1000 W |
| Mounting Type | Through-Hull (Low-Profile) |
| Housing Material | Bronze |
| Transducer Window | Polyurethane |
| Hole Diameter | 95 mm |
| Shaft Length | 71 mm |
| Cable Length | 10 m |
| Integrated Temperature Sensor | Yes |
| Tilt Options | 0°, 12°, or 20° |
| Maximum Hull Angle | 24° |
| Weight | 1.4 kg |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | 33-627-02 |
| Measurement Range | 10–95% RH |
| Accuracy | ±5% RH |
| Resolution | 1% RH |
| IP Rating (when installed) | IPX4 |
| Compatible Systems | Airmar 110WX, 120WX, 150WX, 200WX, 220WX Weather Stations |
| Brand | dataTaker |
|---|---|
| Origin | Imported |
| Model | DT82I |
| Analog Inputs | 6 single-ended / 4 differential / 2 three- or four-wire |
| Resolution | 18-bit |
| Sampling Rate | up to 40 Hz |
| Analog Output | 16-bit DAC, 0–10 V or 0–20 mA |
| Excitation Outputs | 5 V / 12 V selectable, max. 150 mA |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Communication Ports | RJ45, RS232 (host), RS232/RS485/RS422 |
| Protocols | MODBUS RTU (master/slave), MODBUS TCP/IP, ASCII, SDI12 |
| Power Supply | 10–30 VDC |
| Operating Temperature | −40 to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 900 g |
| Internal Storage | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB storage |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Built-in Battery | 6 V @ 1.2 Ah |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | P39 |
| Operating Frequency | 235 kHz |
| Mounting Type | Through-Hull Beam-Mount |
| Depth Range | 0.5–100 m (NMEA 0183), 0.5–150 m (NMEA 2000) |
| Speed Sensing | Paddlewheel with Grooved Flow Channel |
| Temperature Range | −10 to +40 °C |
| Temp Accuracy | ±0.5 °C |
| Beam Angle Adjustment | 0°–22° |
| Weight | 0.5 kg |
| Pressure Rating | 3 m |
| Pulse Resolution | 20,000 pulses per nautical mile |
| Power Supply | 10–28 VDC (NMEA 0183), 9–16 VDC (NMEA 2000) |
| Current Draw | <40 mA (NMEA 0183), <200 mA (NMEA 2000) |
| NMEA 2000 LEN | 4 |
| Compliance | IEC 60945 |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | CM599LH |
| Frequency Bands | Low Band 28–60 kHz (Beamwidth 23°–9°), High Band 130–210 kHz (Beamwidth 8°–4°) |
| Total Bandwidth | 112 kHz |
| Transmit Power | 2000–3000 W |
| Mounting Type | In-Tank Installation |
| Hull Compatibility | Solid Fiberglass |
| Enclosure Material | Epoxy-Resin Housing |
| Weight | 13.73 kg |
| Cable Length | 10 m |
| Integrated Temperature Sensor | No |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | M260 |
| Power Output | 1000 W |
| Operating Frequencies | 50 kHz / 200 kHz |
| Beamwidth | 19° @ 50 kHz / 6° @ 200 kHz |
| Installation Type | In-hull (through-hull cavity mount) |
| Housing Material | Polyurethane & plastic |
| Porthole Diameter | 30 mm |
| Mounting Stub Length | 121 mm |
| Cable Length | 10 m |
| Weight | 6.2 kg |
| Hull Tilt Compensation Range | 0–30° |
| Transducer Window Material | Polyurethane |
| Temperature Sensor | Not integrated |
| Compatible Hull Types | Fiberglass only |
| Minimum Vessel Length | 8 m |
| Proprietary Technology | XducerID® |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41342 |
| Measurement Range | −50 to +50 °C |
| Accuracy (at 0 °C) | ±0.3 °C (standard), ±0.1 °C (optional) |
| Time Constant | 42 s (with 43408 radiation shield) |
| Sensor Type | 1000 Ω Pt RTD, 4-wire configuration |
| Output Options | Resistance (41342), 0–1 VDC (41342VC), 4–20 mA (41342LC) |
| Calibration | Selectable °C or °F |
| Recommended Radiation Shield | 43502 (aspirated) or 41003P (multi-plate passive) |
| Recommended Cable | 2-pair shielded, 22 AWG (P/N 18641) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41382VC |
| Temperature Range | -50 to +50 °C |
| Temperature Accuracy | ±0.3 °C @ 23 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±1 %RH @ 20 °C |
| RH Stability | <1 %RH/year |
| Response Time (with radiation shield) | 10 s |
| Output Signal | 0–1 VDC or 0–5 VDC (jumper-selectable) |
| Power Supply | 12–30 VDC |
| Operating Ambient Temperature | -50 to +50 °C |
| Dimensions | Ø64 mm × 176 mm |
| Weight | 200 g |
| Sensor Type (Temp) | Platinum RTD (Pt1000) |
| Sensor Type (RH) | Rotronic Hygromer® capacitive polymer |
| Recommended Cable | 5-conductor shielded (Young P/N 18723) |
| Optional Radiation Shields | 43502 (aspirated), 41003P (multi-layer passive) |
| Brand | Vaisala |
|---|---|
| Origin | Finland |
| Model | WXT531 |
| Measurement Principle | Ultrasonic Rain Detection (RAINCAP®) |
| Output | Cumulative Rainfall (mm), Rain Duration (s), Rain Intensity (mm/h) |
| Range | 0–200 mm/h |
| Resolution | 0.01 mm |
| Accuracy | ±5% (field-dependent) |
| Rain Duration Resolution | 10 s |
| Rain Intensity Calculation | Sliding 1-minute average, 10-s step |
| Operating Temperature | −52 to +60 °C |
| Storage Temperature | −60 to +70 °C |
| Enclosure Rating | IP65 (without mounting gland), IP66 (with mounting gland) |
| Power Supply | 6–24 VDC |
| Typical Current Consumption | 3 mA @ 12 VDC (default measurement interval) |
| Heating Option | 12–24 VDC / 12–17 VAC, 0.8 A @ 12 VDC |
| Digital Interfaces | SDI-12 v1.3, RS-232, RS-485, RS-422 |
| Communication Protocols | ASCII Polling/Automatic Mode, NMEA 0183 v3.0 |
| Analog Outputs | 4–20 mA (optional, configurable per parameter) |
| Compliance | IEC 60945 (Maritime), EN 61326-1 (EMC), RoHS, CE |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | RGA |
| Housing Material | Anodized Aluminum & Stainless Steel |
| Sensor Type | Tipping Bucket |
| Switch Mechanism | Reed Switch |
| Output Signal | Momentary Pulse (< 0.1 s duration) |
| Resolution Options | 0.25 mm, 0.2 mm, or 0.1 mm per tip |
| Accuracy | ±0.5% at 12.5 mm/h rainfall rate |
| Effective Orifice Diameter | 21.9 cm |
| Height | 31.75 mm |
| Integrated Level Indicator | Yes |
| Mounting Compatibility | RainWise Monopod Stand |
| Brand | CAMPBELL |
|---|---|
| Origin | USA |
| Model | CR350 |
| Operating Temperature | -40 to +70 °C (standard, non-condensing) |
| Max Scan Rate | 10 Hz |
| Enclosure Material | High-impact polycarbonate (Recycling Code 7) |
| Analog Inputs | 4 single-ended or 2 differential (software-configurable) |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Terminals | 2 (VX1, VX2) |
| Communication Interfaces | USB Type-C 2.0, RS-232, RS-485 |
| 12 V Switched Power Outputs | 2 |
| Digital I/O | 7 (C1, C2, P_SW, SE1–SE4 |
| Input Range | -100 to +2500 mV |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40 °C |
| ADC Resolution | 24-bit |
| Power Supply Input (CHG) | 16–32 Vdc (max 1.1 A for charger/solar input) |
| Real-Time Clock Accuracy | ±1 min/month |
| Supported IP Protocols | Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS v1.2, DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, MQTT(S) |
| Communication Protocols | PakBus, PakBus Encryption, Modbus RTU/ASCII/TCP, DNP3, SDI-12 |
| CPU & Program Memory | 50 MB serial flash |
| Data Storage | 50 MB serial flash |
| Idle Current Draw | 0.5 mA (@ 12 Vdc) |
| Active Current Draw | 8 mA (@ 12 Vdc, processor always on) |
| Dimensions | 16.3 × 8.4 × 5.6 cm (6.4 × 3.3 × 2.2 in.) |
| Weight | 288–306 g (0.64–0.68 lb), depending on comms options |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | P75M |
| Output Power | 600 W |
| Operating Frequency | 80–130 kHz (Chirp) |
| Beam Width | 24°–16° (adjustable) |
| Max Depth Range | 213 m (700 ft) |
| Depth Accuracy | ±0.54% of reading |
| Depth Resolution | 0.01 m |
| Housing Material | Polyurethane (liquid-filled) |
| Weight | 0.45 kg (1.1 lb) |
| Hull Angle Compensation | 2°–20° adjustable |
| Compatible Hull Type | Solid fiberglass only |
| Transducer Mounting | Internal through-hull installation with Xducer ID® technology |
| Environmental Fill Fluid | Non-toxic, freeze-resistant coupling medium |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | PM265LH |
| Transmit Power | 1000 W |
| Low-Frequency Range | 42–65 kHz (Beamwidth: 25°–16°, Max Depth: 914 m) |
| High-Frequency Range | 130–210 kHz (Beamwidth: 10°–6°, Max Depth: 304 m) |
| Total Transducer Bandwidth | 103 kHz |
| Housing Material | Bronze |
| Mounting Options | Tank, Hull Cavity, Pocket/Kiel Mount |
| Transducer Window | Polyurethane |
| Operating Temperature Sensor | Integrated Fast-Response Thermistor |
| Compatible Hull Types | Solid Fiberglass Only (≥8 m LOA) |
| Weight | 5.2 kg |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT80G |
| Analog Inputs | 15 single-ended / 10 differential / 5 three- or four-wire |
| Resolution | 8-bit |
| Sampling Rate | up to 40 Hz |
| Vibrating Wire Channel | integrated, 500–5 kHz range, coil resistance 50–200 Ω, excitation pulse: 36 V @ 200 µs |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Communication | RJ45 (Ethernet), USB, RS232/RS485/RS422 |
| Protocols | MODBUS RTU/TCP, SDI-12, ASCII, HTTP, FTP, SMTP |
| Power | 10–30 VDC |
| Operating Temperature | −40 to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 1.5 kg |
| Internal Storage | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB drive |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Internal Battery | 6 V @ 1.2 Ah |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | UDST800 |
| Output | NMEA 0183 |
| Transducer Frequency | 4.5 MHz |
| Pulse Repetition Frequency | 0.5–12 kHz (adaptive) |
| Speed Range | 0.1–50 knots |
| Operating Temperature | −4 to 40 °C |
| Supply Voltage | 9–16 VDC |
| Average Current Draw | 125 mA @ 12 VDC |
| Housing Material | Plastic / Bronze / Stainless Steel |
| Housing Diameter | 51 mm |
| Weight | 1.4 kg (plastic) / 1.8 kg (bronze) |
| Compliance | EN 60945, IEC 61162-1/-2 |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41342VC |
| Output Signal | 0–1 VDC |
| Sensor Type | Pt1000 RTD (4-wire) |
| Measurement Range | −50 to +50 °C |
| Accuracy @ 0 °C | ±0.3 °C (standard), ±0.1 °C (optional) |
| Time Constant | 42 s (with Model 43408 radiation shield) |
| Calibration Options | °C or °F |
| Enclosure | Weatherproof terminal housing |
| Recommended Radiation Shield | Model 43502 (aspirated) or Model 41003P (multi-plate passive) |
| Recommended Cable | 2-pair shielded, 22 AWG (e.g., Part #18641) |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | B122 |
| Operating Frequency | 235 kHz |
| Depth Range | 0.5–180 m |
| Temperature Range | −10 to +40 °C |
| Temp Accuracy | ±0.5 °C |
| Max Hull Angle (with fairing) | 28° |
| Housing Material | Bronze |
| Power Supply | 9–16 VDC, <200 mA |
| Weight | 3.9 kg |
| Transducer Window | Urethane |
| Mounting Options | Through-hull (51 mm hole) or Low-profile via Adapter Ring |
| IP Rating | IEC 60945 Compliant |
| NMEA 2000 LEN | 4 |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | SS75M |
| Operating Frequency Range | 80–130 kHz |
| Output Power | 600 W |
| Beamwidth | 24°–16° (depending on tilt) |
| Transducer Mounting | Through-hull |
| Housing Material | Stainless Steel |
| Cutout Diameter | 70 mm |
| Shaft Length | 95 mm |
| Cable Length | 10 m |
| Integrated Temperature Sensor | Yes |
| Weight | 1.4 kg |
| Maximum Hull Deadrise Angle | 28° |
| Acoustic Window Material | Polyurethane |
| Compatible Hull Materials | Fiberglass, Wood |
| Chirp Bandwidth | 50 kHz |
| Target Detection Depth | Up to 3,000 m |
| Tilt Options | 0°, 12°, 20° |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | SS60 |
| Frequency Bands | 50 kHz / 200 kHz |
| Beam Width | 45° @ 50 kHz, 12° @ 200 kHz |
| Transmit Power | 600 W |
| Housing Material | Stainless Steel |
| Mounting Type | Low-Profile Through-Hull |
| Cutout Diameter | 60 mm |
| Stub Length | 68.5 mm |
| Cable Length | 10 m |
| Integrated Tilt Sensor | Yes |
| Integrated Temperature Sensor | Yes |
| Maximum Hull Tilt Compensation | 24° |
| Acoustic Window Material | Polyurethane |
| Weight | 1.4 kg |
| Recommended Hull Length | Up to 8 m (25 ft) |
| Compatible Hull Inclinations | 0°, 12°, 20° |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | M195 |
| Operating Frequencies | 30 kHz / 200 kHz |
| Depth Range | 0.4–200 m |
| Depth Accuracy | ±0.54% FS |
| Depth Resolution | 0.01 m |
| Temperature Sensor | 10 kΩ NTC thermistor |
| Temp Range | −5 to +60 °C |
| Temp Accuracy | ±0.05 °C |
| Temp Resolution | 0.09 °C |
| Output Protocols | NMEA 0183 (4800 baud), Echo-Envelope RS485 (921600 baud) |
| Power Supply | 9–40 VDC |
| Avg. Current Draw | 300 mA @ 12 VDC |
| Max. Power | 100 W |
| Submersible Depth | Up to 10 m |
| Cable | 15 m C304, 5-pair shielded twisted pair with polyurethane jacket |
| Housing Material | Seamless polyurethane (SeamCast™) |
| Certifications | CE, IEC 60945 |
| Reverse Polarity Protection | Yes |
| Weight | 6.5 kg |
| Dimensions | See official dimensional drawing |
Show next