- All
- Favorite
- Popular
- Most rated
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05305 |
| Instrument Type | Cup Anemometer & Wind Vane Sensor |
| Resolution | 0.1 m/s |
| Measurement Range | 0–50 m/s (wind speed), 0–360° (wind direction) |
| Accuracy | ±0.2 m/s or ±1% of reading (wind speed), ±3° (wind direction) |
| Startup Wind Speed | 0.4 m/s (cup), 0.5 m/s (vane) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Output Options | AC pulse (3 pulses/rev), 0–5 VDC, or 4–20 mA |
| Housing Material | UV-stabilized polymer with stainless steel and anodized aluminum hardware |
| Bearing Type | Precision stainless steel ball bearings |
| Compliance | EPA PSD Guidelines, NRC RG 1.23, ANSI/ANS-18.1 |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver II |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–65 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Ingress Protection | IP66 |
| Housing Material | Stainless Steel |
| Certification | Lloyds Register Type Approved |
| Output Interfaces | 1 digital (RS-422/RS-485), 3 analog (4–20 mA or 0–10 V) |
| WMO Compliance | Wind averaging and gust algorithms aligned with WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Optional Feature | Integrated de-icing system |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver 70 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55°C to +70°C |
| Operating Humidity | 0–100% RH |
| Heating Power | 150 W (1 W/cm²) |
| Electrical Input | 7 A @ 24 VAC/DC |
| Wind Direction Range | 0–360° (dead-zone-free) |
| Calibration | NIST-traceable |
| Enclosure Material | Stainless steel |
| Ingress Protection | IP66 |
| Compliance | FAA AC 150/5220-9C, UK CAA CAP 744, ICAO Annex 3, WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No.8, 7th ed., 2008) |
| Brand | Vaisala |
|---|---|
| Origin | Finland |
| Model | WXT532 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±3% @ 10 m/s |
| Operating Temperature | −52 °C to +60 °C |
| Relative Humidity Range | 0–100% RH |
| Ingress Protection | IP65 (without mounting adapter), IP66 (with mounting adapter) |
| Output Options | SDI-12 v1.3, RS-232, RS-485, RS-422, NMEA 0183 v3.0 |
| Analog Outputs (optional) | 0–20 mA or 4–20 mA for wind speed and wind direction |
| Power Supply | 6–24 VDC |
| Typical Current Consumption | 3 mA @ 12 VDC (default measurement interval) |
| Heater Supply | 12–24 VDC / 12–17 VAC |
| Heater Current | 0.8 A @ 12 VDC, 0.4 A @ 24 VAC |
| Response Time | 0.25 s |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±3° @ 10 m/s |
| Wind Direction Resolution | 1° |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic 75 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Output Options | RS-232/RS-485 serial, dual analog (4–20 mA or 0–5 V), NMEA 0183 compliant |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05108-45 |
| Instrument Type | Cup Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±3% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +60°C |
| Operating Humidity | 0–100% RH |
| Bearing Material | High-Wear-Resistant Ceramic |
| Output Signal | Magnetic pulse (3 pulses per revolution |
| Propeller Diameter | 18 cm |
| Overall Height | 40 cm |
| Length (including propeller) | 57 cm |
| Mounting Tube Diameter | 34 mm (1-inch standard pipe) |
| Weight | 1.0 kg |
| Ice-Resistant Coating | Yes |
| Color Finish | Matte Black (enhances solar heating for passive de-icing) |
| Brand | NK |
|---|---|
| Origin | USA |
| Model | Kestrel 5400 |
| Instrument Type | Vane Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0.4–60 m/s |
| Accuracy | ±3% |
| Operating Temperature | −10 to 55 °C |
| Operating Humidity | 0–100% RH |
| IP Rating | IP67 |
| Data Logging Capacity | >10,000 timestamped records |
| Power | AA batteries (≈400 h typical life) |
| Wireless Connectivity | Bluetooth Smart® (Kestrel LiNK) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 86106 |
| Instrument Type | Ultrasonic Anemometer |
| Wind Speed Range | 0–75 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±2% (0–30 m/s), ±3% (30–70 m/s) |
| Wind Direction Range | 0–360° |
| Wind Direction Resolution | 0.1° |
| Wind Direction Accuracy | ±2° |
| Startup Threshold | 0.01 m/s |
| Response Time | <0.25 s |
| Operating Temperature | −40 to +60 °C |
| Relative Humidity | 0–100% RH |
| Output Options | NMEA 0183, RS-232/RS-485, Analog (0–5 V / 4–20 mA) |
| Enclosure Rating | IP65 |
| Dimensions | 29 cm H × 11 cm W |
| Weight | 0.4 kg |
| Power Supply | 10–30 VDC (heater: 24 VDC, 2.5 A for heated variants) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 81000V |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Wind Speed Range | 0–40 m/s |
| Accuracy | ±1% (0–30 m/s), ±3% (30–40 m/s) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Wind Direction Range | 0–360° |
| Elevation Angle Range | ±60° |
| Sonic Temperature Range | −50°C to +50°C |
| Output Options | RS-232 / RS-485 serial, 4-channel analog voltage input (81000V), sampling rate up to 160 Hz, user-selectable output frequency (4–32 Hz) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 09101 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±2% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Output Interface | RS-485 serial (RMY/NCAR/NMEA protocols) |
| Startup Wind Speed | 1.0 m/s |
| Bearing Type | Precision stainless steel ball bearing |
| Mounting | Standard 1-inch NPT pipe thread |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–50 m/s |
| Accuracy | ±1.5% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | 20 Hz (32 Hz optional) |
| Outputs | U, V, W velocity components, sonic temperature, speed of sound |
| Construction | Aluminum alloy and carbon fiber housing |
| Calibration | Optional traceable wind tunnel calibration per unit |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster HS |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | 32 Hz |
| Output Signals | U, V, W vector components, sonic temperature |
| Housing Material | Stainless steel |
| Analog I/O | 4-channel integrated electronics |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | GMX260 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±0.3 m/s (RMSE: 0.3 m/s at 0–10 m/s |
| Operating Temperature | −35 to +70 °C |
| Operating Humidity | 0–100 % RH |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±3° (0.5–40 m/s), ±5° (40–60 m/s) |
| Wind Direction Resolution | 1° |
| Output Protocols | RS232, RS422, RS485, SDI-12 v1.3, NMEA 0183, MODBUS (RTU & ASCII), ASCII |
| Output Frequency | 1 Hz, 1 min, 1 hour, or polled |
| Power Supply | 5–30 VDC |
| Power Consumption | 28 mA (nominal, 12 VDC, continuous, standard) |
| Enclosure Rating | IP66 & IP68 |
| Housing Material | UV-stabilized thermoplastic |
| Mounting | Compatible with 44.45 mm (1.75 in) mast/tube |
| Weight | 0.5 kg |
| Optional | Integrated GPS (provides position, altitude, UTC timestamp, and true wind vector correction for moving platforms) |
| Brand | Davis Instruments |
|---|---|
| Origin | USA |
| Model | 6332 |
| Instrument Type | Cup Anemometer with Integrated Wind Vane |
| Resolution | 0.1 m/s |
| Measurement Range | 0.5–89 m/s |
| Accuracy | ±5% of reading (±1 m/s, whichever is greater) |
| Operating Temperature | −40 °C to +65 °C |
| Operating Humidity | 0–100% RH |
| Wireless Transmission Range | Up to 300 m (line-of-sight), 75–150 m through obstacles |
| Power Source | Solar panel (0.5 W) + rechargeable CR-123A 3 V lithium battery |
| Battery Runtime | 8 months (no solar input), ≥2 years (typical solar exposure) |
| Data Storage Capacity | 2560 records |
| Logging Intervals | 1, 5, 10, 15, 30, 60, or 120 minutes |
| Communication Interface | RS-232 or USB |
| Baud Rate | 1200–19200 bps, half-duplex |
| Sensor Cable Length | 12 m (standard), up to 73 m optional |
| Wind Direction Range | 1–360° |
| Wind Direction Accuracy | ±3° |
| Wind Direction Resolution | 1° (digital), 22.5° (16-point compass) |
| ISS Housing Material | UV-stabilized ABS and polycarbonate |
| ISS Dimensions | 159 × 58 × 200 mm |
| ISS Weight | 0.48 kg |
| Mounting Mast Diameter | 33 mm (1.3″ OD) |
| Tripod Height | 1.77 m (total), 0.92 m mast height |
| Tripod Material | Galvanized steel |
| Control Console Operating Temp | 0–+60 °C |
| Console Display | Backlit LCD (151 × 86 mm active area) |
| Console Weight | 0.85 kg (with batteries) |
| Wireless Channel Support | Up to 8 remote stations per console |
| Brand | Davis Instruments |
|---|---|
| Origin | USA |
| Model | 7911 |
| Instrument Type | Cup Anemometer with Vane-Based Direction Sensor |
| Wind Speed Range | 0.5–89 m/s |
| Wind Speed Accuracy | ±5% or ±1 m/s (whichever is greater) |
| Wind Speed Resolution | 0.1 m/s |
| Wind Speed Sampling Interval | 2.25 s |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±7° |
| Wind Direction Resolution | 1° |
| Wind Direction Sampling Interval | 1 s |
| Operating Temperature | −40°C to +66°C |
| Operating Humidity | 0–100% RH |
| Housing Material | UV-stabilized ABS (vane), Polycarbonate (cups), Anodized Aluminum (crossarm) |
| Cable | 4-conductor, 26 AWG, standard RJ11 connector |
| Standard Cable Length | 12 m |
| Maximum Extended Cable Length | 42 m |
| Dimensions | 470 mm × 191 mm × 121 mm |
| Weight | 1.332 kg |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±2% @ 12 m/s |
| Operating Temperature | −35 to +70 °C |
| Relative Humidity Range | 5–100% RH |
| Output Options | RS-232/RS-485 serial, dual analog (4–20 mA or 0–5 V) |
| Status Code | Integrated diagnostic flag per data packet |
| Housing Material | UV-stabilized polycarbonate |
| Moving Parts | None |
| Compliance | IP66 rated, CE marked, RoHS compliant |
| Brand | Gill |
|---|---|
| Origin | UK |
| Model | WindObserver IS |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0 – 75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −30 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Certifications | ATEX II 2 G IIC T4 Ga, IECEx EXA 20.0029X, UKEX 20ATEX0002X |
| Compliance | UK CAA CAP 437, WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Output Options | Gill Serial Protocol, NMEA 0183, 4–20 mA (isolated), RS-485 |
| Power Supply | 12–30 VDC or 24 VAC |
| Ingress Protection | IP66 |
| Expected Service Life | >10 years in offshore environments |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 09106 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±2% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +50°C |
| Relative Humidity Range | 0–100% RH |
| Wind Direction Range | 0–360° |
| Wind Direction Resolution | 1° |
| Wind Direction Accuracy | ±2° |
| Startup Wind Speed (Propeller) | 1.0 m/s |
| Output Interface | RS-485 serial (RMY, NCAR, or NMEA protocol), configurable for polled or continuous mode |
| Power Supply | 11–24 VDC, 20 mA |
| Dimensions (H × L) | 37 cm × 55 cm |
| Propeller Diameter | 18 cm |
| Mounting Tube Diameter | 34 mm (1-inch standard pipe) |
| Sensor Weight | 1.0 kg |
| Shipping Weight | 2.3 kg |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | HS-100 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Operating Humidity | 0–100% RH |
| Output Frequency | 100 Hz |
| Wind Direction Range | 0–360° |
| Output Format | U/V/W orthogonal velocity components |
| Construction Material | Stainless steel |
| Compliance | Designed for GLP-compliant field deployment and long-term environmental monitoring |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 86000 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Wind Speed Range | 0–75 m/s |
| Accuracy | ±2% (0–30 m/s), ±3% (30–70 m/s), or ±0.1 m/s (whichever is greater) |
| Wind Direction Range | 0–360° |
| Wind Direction Resolution | 0.1° |
| Wind Direction Accuracy | ±2° |
| Startup Threshold | 0.01 m/s |
| Response Time | <0.25 s |
| Operating Temperature | −40°C to +60°C |
| Humidity Range | 0–100% RH |
| Output Options | RS-232/RS-485, 0–5 VDC analog, 4–20 mA current loop, SDI-12 |
| Enclosure Rating | IP65 |
| Dimensions | 29 cm H × 11 cm W |
| Weight | 0.4 kg |
| Power Supply | 10–30 VDC (standard), 24 VDC/2.5 A (heated model 86004) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05103 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±0.3 m/s or ±1% of reading |
| Operating Temperature | −50°C to +50°C |
| Relative Humidity Range | 0–100% RH |
| Startup Wind Speed (Propeller) | 1.0 m/s |
| Startup Wind Speed (Vane) | 1.1 m/s |
| Wind Direction Range | 360° mechanical, 355° electronic (5° dead zone) |
| Wind Direction Accuracy | ±3° |
| Output Options | AC pulse (3 pulses/rev), 0–5 VDC (05103V), or 4–20 mA (05103L) |
| Power Supply | 15 VDC (sensor only) |
| Housing Material | UV-stabilized polymer with stainless steel and anodized aluminum hardware |
| Bearing Type | Precision stainless steel ball bearings |
| Mounting | Standard 1-inch NPT pipe thread |
| Weight | 1.0 kg (sensor), 2.3 kg (shipping) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05106 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±3% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +60°C |
| Relative Humidity Range | 0–100% RH |
| Wind Direction Range | 360° mechanical, 355° electronic (5° dead zone) |
| Wind Direction Accuracy | ±3° |
| Startup Wind Speed | 1.0 m/s (propeller), 1.1 m/s (vane) |
| Output | Magnetic pulse (3 pulses/rev) for wind speed |
| Power Supply | 15 VDC excitation (sensor) |
| Dimensions | 55 cm length × 37 cm height × 18 cm propeller diameter |
| Mounting | Standard 1-inch NPT pipe thread |
| Weight | 1.0 kg (sensor only), 2.3 kg (shipping) |
| Brand | NK |
|---|---|
| Origin | USA |
| Model | 0801 |
| Instrument Type | Vane Anemometer Impeller |
| Resolution | 0.1 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55°C to +70°C |
| Operating Humidity | 0–100% RH |
| Compliance | Designed for use with Kestrel Series handheld environmental meters (e.g., Kestrel 4000, 5000, 5500, DROP series) |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | HS-50 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Operating Humidity | 0–100% RH |
| Output Rate | 50 Hz |
| Wind Direction Range | 0–360° |
| Output Format | U, V, W vector components |
| Construction | Stainless steel |
Show next