- All
- Favorite
- Popular
- Most rated
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | GC-9780B |
| Instrument Type | Portable Gas Chromatograph |
| Application Domain | Power Industry–Specific |
| Oven Temperature Range | 8 °C above ambient to 400 °C |
| Ramp Rate | 5 °C/min |
| Cool-down Rate | 350 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Control Range | 0–30 mL/min |
| Carrier Gas Pressure Control Range | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Detection Limits | 0.05–20,000 ppm (compound-dependent) |
| Analysis Cycle Time | <20 min |
| Quantitative Repeatability | ≤1% RSD |
| Qualitative Repeatability | ≤0.2% RSD |
| Baseline Noise | ≤0.1 mV |
| Baseline Drift | ≤0.5 mV/30 min |
| Pulsed Discharge Detector (PDD) Sensitivity | ≤1.0×10⁻¹¹ g/mL (for representative analytes) |
| Power Supply | 24 V DC (internal Li-ion battery, 21,000 mAh) |
| AC input | 220 V ±10%, 50 Hz |
| Dimensions | 640 × 585 × 420 mm |
| Weight | <50 kg |
| Power Consumption | ≤200 W |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | HA-2030 |
| Quotation | Upon Request |
| Application Domain | Power Industry Dedicated |
| Oven Temperature Range | Ambient to 450 °C |
| Oven Ramp Rate | 10 °C/min |
| Carrier Gas Pressure Range & Control | 0.4–0.8 MPa |
| Injector Maximum Operating Temperature | 50 °C |
| Injector Pressure Setting Range | 0–0.2 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HA-9680-L |
| Price Range | USD 28,000 – 52,000 |
| Instrument Type | Online Gas Chromatograph |
| Application Domain | Petrochemical Industry Specific |
| Explosion Protection Certification | NEPSI Certified EX d ib mb px II CT4 Gb |
| Sample Phase | Liquid |
| Injection Mode | Direct Liquid Injection |
| Regulatory Compliance | Meets IEC 60079-0, IEC 60079-1, IEC 60079-11 for Zone 1/2 hazardous areas |
| Thermal Management | Integrated heated sampling & transfer lines (up to 180 °C) |
| Detector Options | FID, TCD, PID (configurable) |
| Data Output | 4–20 mA analog, Modbus TCP, OPC UA |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC-9560-HD DGA System |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Power Industry–Specific |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Column Oven Cooling Time | <5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Operating Temperature | 399 °C |
| Injector Pressure Setpoint Range | 0–0.4 MPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detection Limits (as per DL/T 703–1999) | H₂ <2 µL/L, O₂ <5 µL/L, N₂ <5 µL/L, CO <2 µL/L, CO₂ <2 µL/L, Hydrocarbons <0.1 µL/L |
| Temperature Stability | ±0.1 °C across all zones (oven, injector, detectors, methanizer) |
| Detectors | Dual-channel TCD and FID with Ni-catalyst methanizer |
| Column Configuration | Parallel dual-column gas separation path |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC-9560-PDD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Dedicated High-Purity & Electronic Specialty Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | ~7 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–500 psi |
| Injector Total Flow Setpoint Range | 0–1000 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | GC-9560-HB |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Ramp Rate | 1–40 °C/min |
| Cooling Rate | ~7 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | Huai Chromatography |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9560-HC |
| Temperature Control Range | 0–400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Rate | 350→50 °C in ≤8 min |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Detection Limit (H₂ matrix, TCD) | O₂/N₂/CO/CH₄/CO₂ ≤ 0.1–2 ppm (3 mL sample) |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-9580-HD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry Dedicated |
| Temperature Control Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Time | ≤7 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | 8 °C above ambient to 400 °C |
| Carrier Gas Flow Range & Control | 1–1000 mL/min |
| Detector Configuration | PDHID S Pro+ (Pulsed Discharge Helium Ionization Detector) |
| Channel Options | Single-Channel or Multi-Channel Parallel Analysis |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560-HG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Ultra-High-Purity (UHP) Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Heating Rate | 1–40 °C/min |
| Cooling Rate | ~7 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization (PDHID) |
| Detection Limit | ≤1.0×10⁻¹⁰ g/mL (for organic compounds) |
| H₂ | 5 ppb, O₂/Ar: 10 ppb, N₂: 10 ppb, CH₄: 5 ppb, CO: 25 ppb, CO₂: 5 ppb |
| Temperature Control Precision | ±0.1 °C (eight independent zones) |
| Programmed Temperature Ramping | 8-step |
| Data Acquisition | 20 Hz, 24-bit A/D, dynamic range 10⁶ |
| Compliance | GB/T 28726–2012, GB/T 3634.2–2011, GB/T 14599–2008, GB/T 8979–2008, GB/T 4842–2006, GB/T 4844–2011, GB/T 17873–1999, GB/T 5829–2006, GB/T 5828–2006, HG/T 3633–1999, GB 10621–2006, GB/T 23938–2009, GB/T 28125.1–2011 |
| Brand | HA-Ai |
|---|---|
| Model | HA-H2 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Detection Principle | Thermal Conductivity Detection (TCD) |
| Maximum Permissible Error | ±1%–±10% FS |
| Zero Drift | ≤1% FS/24h |
| Span Drift | ≤3% FS/24h |
| Repeatability | ≤2% RSD |
| Compliance | GB/T 37154–2018, GB/T 24549–2009 |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HA-9680-D |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | 0–300 °C (operating range), max. ramp rate 10 °C/min |
| Carrier Gas Pressure Control Range | 0–0.6 MPa |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Explosion Protection Rating | Ex db IIC T4 Gb |
| Ingress Protection Rating | IP66 |
| Remote Control Interface | Web-based and WeChat Mini Program (cloud-connected) |
| Brand | Huaai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic (China-Made) |
| Model | Fuel Hydrogen Analysis System |
| Pricing | Upon Request |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-9560-PDD |
| Temperature Control Range | 0–400 °C |
| Ramp Rate | 0–40 °C/min |
| Cool-down Rate | 350 °C → 50 °C (typical) |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 psi |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDD) |
| Detection Limit for Trace Impurities | ≤5 ppb (v/v) in high-purity SiCl₄ matrix |
| Application Focus | Ultra-high-purity electronic-grade gas analysis (e.g., SiCl₄, SiHCl₃, SiH₂Cl₂, CH₃SiCl₂) |
| Column Configuration | Multi-oven column switching architecture with center-cutting valving |
| Sample Introduction | Backflush-capable, purged valve system with active guard gas routing |
| Pressure Calibration | Integrated automatic inlet pressure correction algorithm for variable-base-gas samples |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | Huaai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Fluorine-Containing Gas Analysis |
| Temperature Control Range | Ambient +8°C to 399°C |
| Oven Ramp Rate | 1–40°C/min |
| Oven Cool-Down Rate | ~7 min (from 350°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Operating Temperature | 399°C |
| Injector Pressure Setpoint Range | 0–0.4 MPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detector | Dual Corrosion-Resistant Thermal Conductivity Detectors (TCD) |
| Sampling | Negative-Pressure Sampling with 316L Stainless Steel Adsorption Vessel and PTFE-Sealed Valves |
| Valve Type | VICI 1/8" Six-Port and Four-Port Switching Valves |
| Software | PC-Based Bidirectional Remote Control with 6 Programmable Event Outputs for Valve/Pump Sequencing |
| Compliance | Designed for GLP-compliant HF gas analysis in semiconductor, fluoropolymer, and specialty gas manufacturing environments |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (PRC) |
| Model | GC-9560-HTP |
| Pricing | Upon Request |
| [Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC-9560-HD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry-Specific |
| Temperature Control Range | Ambient to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate | 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–800 mL/min] |
| Brand | Huaai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HA-9660-VOCs |
| Pricing | Upon Request |
| Compliance | HJ 1013–2018, HJ 1010–2018, HJ 1012–2018, GB 16297–1996, DB32/2862–2016, GB 18580–2017, HJ/T 400–2007 |
| Detection Principle | Gas Chromatography with FID/TCD/PDD Detectors |
| Sample Throughput | 50 mL/min |
| Carrier Gas | N₂/H₂/Ar/He (150 mL/min, 0.4 MPa) |
| Analysis Cycle | ≤2 min |
| LOD (NMHC) | ≤0.8 mg/m³ (≈0.13 µmol/mol) |
| Repeatability (RSD) | ≤2% |
| Linearity Error | ±2% F.S. |
| 24-h Drift | ±3% F.S. |
| Power | AC 220 V, 50–60 Hz, 400 W |
| Dimensions | 482 mm (W) × 222 mm (H) × 400 mm (D), 5U Rack-Mountable |
| Weight | 20 kg |
| Data Interface | RS-232/RS-485, Modbus RTU |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry Specific |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Rate | ~50 °C in ≈7 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HA-9680-H |
| Application Domain | High-Purity Hydrogen Gas Analysis |
| Oven Temperature Range | Ambient to 450 °C |
| Ramp Rate | 10 °C/min |
| Carrier Gas Pressure Control Range | 0.4–0.8 MPa |
| Injector Maximum Operating Temperature | 50 °C |
| Injector Pressure Setting Range | 0–0.2 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HA-9660-PDD |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 8°C above ambient to 400°C |
| Ramp Rate | 1–40°C/min |
| Cool-down Rate | 400°C to 50°C in 7 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min (electronic monitoring) |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa (8-step setting) |
| Injector Max Temp | 400°C |
| Injector Pressure Setting Range | 0–0.1 MPa |
| Injector Total Flow Setting Range | 0–50 mL/min |
| Detector | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Detection Limit | ≤5 ppb |
| Drift/Repeatability | ±1%–±5% |
| Sample Gas Flow | 50 mL/min |
| Sample Gas Pressure | 0.1 MPa |
| Sample Inlet | 1/4″ Swagelok SS |
| Carrier Gas | He |
| Carrier Inlet | 1/8″ Swagelok SS |
| Display | LED |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 400 W |
| Weight | 20 kg |
| Dimensions | 482 mm (W) × 222 mm (H) × 400 mm (D), 5U rack-mountable |
| Communication Interface | RS-232 / RS-485 |
| Protocol | Modbus |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | GC9560 |
| Price Range | USD 21,000 – 28,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Temperature Control Range | 0–400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Cooling Rate | 350 °C → 50 °C (typical) |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.5 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.5 MPa |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-1 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Ramp Rate | 1–40 °C/min |
| Cool-down Time | ~7 min (350 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Column Oven Precision | ±0.1 °C |
| Programmed Temperature Steps | 8-step |
| Hold Time per Step | 0–655 min (1-min increments) |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (n-hexadecane / isooctane) |
| FID Baseline Noise | ≤2×10⁻¹³ A |
| FID Drift | ≤2×10⁻¹² A/30 min |
| FID Linearity | ≥10⁶ |
| TCD Sensitivity | ≥2500 mV·mL/mg (n-hexadecane / isooctane) |
| TCD Baseline Noise | ≤20 µV |
| TCD Drift | ≤100 µV/30 min |
| TCD Linearity | ≥10⁴ |
| Dimensions | 655 mm (W) × 500 mm (H) × 480 mm (D) |
| Weight | ~48 kg |
| Power Supply | 220 V ± 22 V, 50 Hz, ≥2 kW |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560-PED |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Ultra-High-Purity Gas Analysis |
| Temperature Control Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Cooling Rate | 350 °C to 50 °C in ≤7 min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa (8-step programmable) |
| Carrier Gas Flow Control Range | 0–0.4 MPa (8-step programmable) |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.1 MPa |
| Injector Total Flow Setting Range | 0–50 mL/min |
| Detection Limit | Sub-ppb (e.g., 0.5–20 ppb depending on analyte and carrier gas) |
| Temperature Stability | ±0.1 °C |
| Programmable Temperature Program | 8-stage |
| Dimensions | 655 mm (W) × 500 mm (H) × 480 mm (D) |
| Weight | ~48 kg |
| Power Supply | 220 V ±22 V, 50 Hz, ≥2 kW |
Show next