Specific Surface Area and Pore Size Analyzer
Filter
Showing 1–30 of 97 results
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Autosorb 6100 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 |
| Specific Surface Area Range | 0.01 m²/g to unlimited |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Theoretical Basis | Vacuum Volumetric Method |
| Reproducibility | <1% RSD (per BAM Reference Material P115) |
| Ambient Operating Temperature | 15–35 °C |
| Temperature Control Accuracy | ±0.05 °C |
| Vacuum System | Dual-stage — Diaphragm Pump + Turbo-Molecular Pump |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PoreMaster eGaIn Filling Station |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static and Dynamic Mercury Intrusion Analogue (eGaIn-based) |
| Compatibility | Designed exclusively for Anton Paar PoreMaster main units and P-type penetrometers (0.5 mL × 1.5 in) |
| Safety Compliance | Mercury-free operation, ISO/IEC 17025-aligned workflow support, GLP-ready data handling |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nova 600BET / 800BET / 600 / 800 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | ≥ 0.01 m²/g (no upper limit) |
| Pressure Range | 1×10⁻⁴ to 0.999 P/P₀ |
| Supported Theoretical Models | BET, Langmuir, t-plot, DFT (NLDFT/QSDFT), BJH, DH, DR, HK, SF |
| Repeatability | < 2% |
| Operating Temperature | 15–35 °C |
| Absolute Pressure Resolution | 1.2×10⁻⁴ Torr |
| Relative Pressure Resolution | 1.5×10⁻⁷ P/P₀ |
| Pore Diameter Range | 0.35–500 nm (0.35–1.1 nm with CO₂ at 273 K) |
| Minimum Detectable Pore Volume | 1.2×10⁻⁸ cm³ |
| Integrated Degassing Stations | 4 (programmable, up to 425 °C) |
| Dewar Capacity | 2 L (up to 40 h operation) |
| Dimensions (D×W×H) | 44 × 63 × 84 cm |
| Weight | 63 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, max. 345 VA |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | 3H-2000PS1X |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (Static Capacity Method) |
| Number of Analysis Stations | 1–8 configurable |
| Specific Surface Area Range | 0.0005 m²/g to unlimited |
| Pressure Range | 10⁻² Pa |
| Repeatability | ≤ ±0.01 (relative standard deviation) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BSD-660 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Pore Size Range | 0.35–500 nm |
| Analytical Theories Supported | BET surface area, BJH pore size distribution (mesopores), DR & HK (Original) micropore analysis, DFT-based pore modeling, IASTL multi-component adsorption modeling |
| Repeatability | ≤0.5% RSD (certified standard reference materials) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660 Series |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | 10⁻² Pa (standard) |
| Test Theory | Static Volumetric Adsorption |
| Repeatability | ≤1% RSD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Model | BSD-660A3M |
| Analysis Stations | 3 / 6 / 9 / 12 |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | ≤1×10⁻² Pa (standard), optional turbomolecular pump for ≤1×10⁻⁸ Pa |
| Measurement Principle | Static Volumetric Gas Adsorption |
| Repeatability | <0.5% RSD for surface area, pore size, pore volume, and adsorbed quantity (certified reference materials) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | BSD-660A3M / BSD-660B3M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Static Capacity Method) |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Surface Area Range | ≥0.0005 m²/g (no upper limit) |
| Pore Diameter Range | 0.35–500 nm (Micropores: 0.35–2 nm |
| Mesopores | 2–50 nm |
| Macropores | 50–500 nm) |
| Total Pore Volume Range | ≥0.0001 cm³/g (no upper limit) |
| Pressure Ranges | 0–1000 torr, 0–1 torr, 0–0.1 torr (selectable) |
| Repeatability | ≤±1.0% |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A3MB3M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥ 0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | Standard: 1×10⁻² Pa |
| Optional Turbo-Molecular Pump | ≤ 1×10⁻⁸ Pa |
| Repeatability | < 0.5% RSD (certified reference material) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | BSD-660A3S |
| Instrument Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Pore Size Range | 0.35–500 nm |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Vacuum Level | ≤1×10⁻⁹ Pa |
| Temperature Control Accuracy | ±0.1 °C (RT–400 °C) |
| Quantitative Repeatability | <0.5% RSD (BET standard reference material) |
| Adsorption Gases | N₂, O₂, Ar, CO, CO₂, H₂, CH₄, C₂H₆ (non-corrosive & combustible) |
| Optional Thermal Control | –10–80 °C (with恒温 water bath) or 100 K–RT (with LNT level stabilization) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | BSD-660A3S / BSD-660B3S |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (BET, t-plot, DFT/NLDFT, BJH, HK, DA, etc.) |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Specific Surface Area Range | ≥0.0005 m²/g (no upper limit) |
| Pore Diameter Range | 0.35–500 nm (Micropores: 0.35–2 nm |
| Mesopores | 2–50 nm |
| Macropores | 50–500 nm) |
| Total Pore Volume Range | ≥0.0001 cm³/g (no upper limit) |
| Pressure Range | 1×10⁻⁸–1000 Torr |
| Vacuum Level | ≤1×10⁻⁹ Pa |
| Repeatability | ≤±1.0% RSD (BET surface area on certified reference materials) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6B3M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 (configurable) |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Repeatability | <0.5% RSD (standard reference material) |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Analysis Stations | 6 Mesopore Stations + 6 Micropore Stations |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | ≤10⁻² Pa (standard), optional molecular pump for ≤10⁻⁸ Pa |
| Repeatability | ≤1% RSD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Model | BSD-660A6M |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 (micro-pore configuration) |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | ≤1×10⁻² Pa (standard), optional turbo-molecular pump for ≤1×10⁻⁸ Pa |
| Repeatability | ≤1% RSD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 6 |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | 10⁻² Pa (standard), down to 10⁻⁸ Pa with optional turbomolecular pump |
| Repeatability | ≤1% RSD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6M / B6M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–1000 torr |
| Theoretical Capabilities | Adsorption/desorption isotherm measurement |
| Repeatability | ≤0.5% RSD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6MB6M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Ultimate Vacuum | ≤1×10⁻⁹ Pa |
| Theoretical Basis | Static Gravimetric/Volumetric Gas Adsorption |
| Repeatability | <0.5% RSD |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Gas Adsorption) |
| Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | 1×10⁻⁹ Pa (ultimate vacuum) |
| Repeatability | ≤±0.5% RSD (BET standard reference material) |
| Temperature Control | Programmable heating (room temp to 400 °C, ±0.1 °C accuracy) |
| Gas Compatibility | N₂, Ar, O₂, CO, CO₂, H₂, CH₄, C₂H₆, and optional corrosive gases (e.g., NH₃, SO₂) and vapors (e.g., H₂O, ethanol) |
| Compliance | ASTM D3663, ISO 9277, ISO 15901-1/2/3, GB/T 19587–2017, GB/T 21650.1–2008, GB/T 21650.2–2008, GB/T 21650.3–2011 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6S |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (Static Capacity Method) |
| Number of Analysis Stations | 1–4 |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | Ambient Pressure |
| Repeatability | ≤ ±1.0% |
| Vacuum Level | Up to 1×10⁻⁹ Pa |
| BET Surface Area Range | ≥0.0005 m²/g |
| Temperature Control Accuracy | Better than ±0.1°C (RT–400°C) |
| Adsorption Gases | N₂, O₂, Ar, CO, CO₂, H₂, CH₄, C₂H₆, etc. |
| Optional Functions | Cryogenic temperature control (100 K–80°C), corrosive gas compatibility, vapor adsorption, LIMS integration |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BSD-660A6S |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Static Capacity Method) |
| Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | 0–1000 torr & 0–1 torr (dual-range transducers) |
| Repeatability | ≤0.5% RSD (certified reference material) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6S/B3M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption (Manometric Method) |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Specific Surface Area Range | ≥0.01 m²/g |
| Pore Size Range | Micropores 0.35–2 nm, Mesopores 2–50 nm, Macropores >50 nm |
| Pressure Range | Up to 10 MPa |
| Repeatability | ≤±0.5% RSD (BET surface area on certified reference materials) |
| Vacuum Level | ≤1×10⁻⁹ Pa |
| Temperature Control Accuracy | ±0.1 °C (programmable from ambient to 400 °C) |
| Adsorption Gases | N₂, Ar, CO₂, O₂, CO, H₂, CH₄, C₂H₆, and corrosive gases (with optional configuration) |
| Vapor Adsorption | Optional with thermostatic bath (−10 to 80 °C) or liquid nitrogen temperature control (100 K to ambient) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Static Capacity Method) |
| Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Repeatability | ±0.01 (RSD) |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 12 |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | down to 1 × 10⁻⁹ Pa |
| Analytical Theory | Static Gravimetric/Volumetric Adsorption |
| Repeatability | ≤0.01% RSD (on certified reference materials) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | BSD-660MG |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 (configurable) |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | Ambient pressure (up to 1000 torr) with ultra-low-pressure capability down to P/P₀ = 1×10⁻⁸ |
| Repeatability | Quantitative error <0.5% RSD (BET standard reference material) |
| Vacuum System | Turbo-molecular pump achieving ultimate vacuum ≤1×10⁻⁸ Pa |
| Gas Compatibility | N₂, O₂, Ar, CO, CO₂, H₂, CH₄, C₂H₆ (non-corrosive & flammable gases) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | BSD-AD8 |
| Instrument Type | Specific Surface Area Analyzer Pre-treatment Unit |
| Analysis Stations | 8 |
| Pressure Range | Up to 1 atm (ambient) |
| Testing Principle | Dynamic Purge Method (Gas Flow Desorption) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BSD-PBx |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Operating Principle | Static Gas Pressure Method (Bubble Point & Gas Flow) |
| Number of Analysis Stations | 1 |
| Pore Size Range | 0.02 – 500 µm |
| Pressure Range | 0–1 bar & 0–40 bar (dual-range, auto-switching) |
| Test Theory | Gas Bubble Point Method |
| Repeatability | ±0.01 µm (on certified reference membranes) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BSD-PM |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (Gas Adsorption) |
| Number of Analysis Stations | 1–12 |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | 0–1000 Torr (with optional 0–0.1 Torr high-resolution sensor) |
| Repeatability | ≤±0.01% for surface area, ≤±0.02 nm for most probable pore diameter |
| Vacuum Level | PS Series — 4×10⁻² Pa |
| Degassing Stations | 2 independent thermal treatment stations (RT–400 °C, ±0.1 °C control accuracy) |
| Independent P₀ Station | Patented helical saturation vapor pressure station |
| Compliance Standards | GB/T 19587–2017, ISO 9277:2010, ISO 15901-1/2/3:2005–2007, GB/T 39713–2020, GB/T 21650.1–3, GB/T 13390–2008, GB/T 10722–2014, GB/T 7702.20–2008, GB/T 6609.35–2009 |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MR1 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Dynamic Gas Flow Adsorption Method |
| Analysis Stations | 1 Pre-treatment Station, 1 Analysis Station |
| Surface Area Range | >0.01 m²/g |
| Pressure Range | 0.30 (standard), 0.02–0.9 (upgraded) |
| Adsorptive Gases | He/N₂ or He/Kr mixtures |
| Pretreatment Temperature | Room Temperature to 400 °C |
| Repeatability | <±1% |
| Measurement Time per Sample | ~10 min (analysis only) |
| Compliance Option | FDA 21 CFR Part 11 & 3Q Validation Support |
| Control Interface | Integrated Touchscreen (standalone operation) |
| Dimensions | W350 × D368 × H553 mm |
| Brand | CDJX |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JB-5 |
| Instrument Category | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic (Flow) Method |
| Number of Analysis Stations | 4 |
| Measurement Range | 0.0005 m²/g to no upper limit |
| Repeatability | ≥99% |
| Calibration Standard | Certified Reference Materials per ISO 9277 & GB/T 19587–2004 |
| Carrier Gas | Ultra-High-Purity Helium (≥99.999%) |
| Adsorptive Gas | Ultra-High-Purity Nitrogen (≥99.999%) |
| Sample Tube Material | Borosilicate Glass (GG-17 U-tube) |
| Typical Analysis Time per Sample | 5–7 min |
| Operating System Compatibility | Windows XP / Windows 7 / Windows 10 |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Dimensions (L×W×H) | 700 × 300 × 600 mm |
| Software Features | Real-time data visualization, comparative analysis tools, audit-ready result export (CSV/PDF), GLP-compliant reporting templates |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | JB-2020 |
| Instrument Type | Specific Surface Area Analyzer |
| Principle | Dynamic (Flow-through) Nitrogen Adsorption |
| Number of Analysis Stations | 1 |
| Measurement Range | 0.0005 m²/g to unlimited |
| Pressure Control Range | 1–5 kPa (gauge) |
| Theoretical Basis | Dynamic nitrogen adsorption coupled with cryogenic adsorption thermodynamics and gas chromatographic response calibration |
| Operating Ambient Temperature | 10–36 °C |
| Repeatability Error | ≤ ±3% |
| Accuracy Error | ≤ ±3% |
| Sample Tube Material | High-temperature-resistant borosilicate glass (GG-type, U-shaped) |
| Carrier Gas | Ultra-high-purity helium (≥99.999%) |
| Adsorbate Gas | Ultra-high-purity nitrogen (≥99.999%) |
| Software Compatibility | Windows 7 / Windows 10 (32/64-bit) |
| Dimensions (W×D×H) | 700 × 360 × 710 mm |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Environmental Requirements | 5–35 °C ambient temperature |