Spectroscopy Instruments
Filter
Showing 1381–1410 of 2631 results
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Scanning Mode | Motorized Automatic Wavelength Selection |
| Compliance | CE-marked, ISO/IEC 17025-compatible operation environment |
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | P8 |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±0.3 nm |
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Single-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 200–1000 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Setting | Motorized Auto-Scanning |
| Display | 128×64 Dot-Matrix LCD |
| Data Output | USB 2.0 Standard Interface |
| Print Output | Parallel Port |
| Power Supply | AC 220 V / 50 Hz or 110 V / 60 Hz |
| Dimensions | 490 × 360 × 210 mm |
| Net Weight | 12 kg |
| Light Sources | Imported Deuterium Lamp & Tungsten-Halogen Lamp |
| Cuvette Compatibility | 5–100 mm Pathlength |
| Lamp Mounting | Plug-in Socket Design |
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | V-1200 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 325–1000 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Setting | Automatic |
| Display | 128 × 64 Dot-Matrix LCD (0.1 nm Resolution) |
| Absorbance Range | –0.3 to 3.0 A |
| Transmittance Range | 0–200% T |
| Light Source | Tungsten Halogen Lamp |
| Data Interface | USB Standard Port |
| Print Interface | Parallel Port |
| Power Supply | AC 220 V / 50 Hz or 110 V / 60 Hz |
| Dimensions | 480 × 360 × 210 mm |
| Weight | 12 kg |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-F |
| Type | Flow Injection Chemiluminescence (FICL) Analyzer |
| Detection Principle | Photomultiplier Tube (PMT)-based chemiluminescence detection with integrated flow injection manifold and electrochemical compatibility |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Software Interface | Windows-native USB communication protocol (USB 2.0 compliant), real-time data streaming to host PC |
| Brand | MPM |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | P7 |
| Instrument Architecture | Dual-Beam |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized Auto-Search |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MS-96 |
| Price Range | USD 42,000 – 70,000 |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MSHyperSIS-VNIR |
| Price Range | USD 14,000 – 43,000 (FOB) |
| Operating Principle | Push-broom scanning |
| Imaging Mode | 3D spatial-spectral data cube acquisition |
| Deployment Platform | Terrestrial (ground-based) |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 0.025 nm (FWHM) |
| Spatial Resolution | 1392 × 1040 pixels |
| Total Field of View (TFOV) | 5° |
| Instantaneous Field of View (IFOV) | 0.05° |
| Frame Rate | 25–120 fps |
| Standard Lens Focal Length | 17 mm |
| Vertical FOV | 40° |
| Horizontal FOV | 70° |
| Scan Speed | ≤100 images/s (CCD-dependent) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | UV-3200 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.03% T at 220 nm and 360 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Photometric Accuracy | ±0.2% T (0–100% T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A) |
| Photometric Repeatability | ≤0.15% T (0–100% T), ±0.001 A (0–0.5 A), ±0.002 A (0.5–1 A) |
| Baseline Flatness | ±0.0015 A (200–1000 nm) |
| Drift | ±0.001 A/h at 500 nm |
| Noise | ±0.0005 A |
| Display | 320 × 240 LCD |
| Scan Speed Options | High/Medium/Low (up to 3800 nm/min) |
| Data Interface | USB |
| Print Interface | Parallel Port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions | 590 × 420 × 260 mm |
| Weight | 20 kg |
| Brand | MupuDa |
|---|---|
| Origin | Shanghai, China |
| Model | UV-6100 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03%T at 220 nm and 360 nm |
| Photometric Accuracy | ±0.002 A (0–0.5 A), ±0.004 A (0.5–1.0 A), ±0.2%T (0–100%T) |
| Photometric Repeatability | ≤0.001 A (0–0.5 A), ≤0.002 A (0.5–1.0 A), ≤0.15%T (0–100%T) |
| Baseline Drift | ±0.0003 A/h (at 500 nm, after warm-up) |
| Baseline Flatness | ±0.0005 A |
| Noise Level | 0.0003 Abs (at 500 nm) |
| Scan Speed | High/Medium/Low, up to 3800 nm/min |
| Photometric Range | –4 to +4 A, 0–200%T, 0–9999 C |
| Display | 320 × 240 dot-matrix LCD |
| Data Interface | USB port, parallel printer port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions | 590 × 420 × 260 mm |
| Weight | 26 kg |
| Brand | MVI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Vista-IR |
| Instrument Category | Laser-Based Infrared Spectrometer |
| Instrument Type | Laboratory Benchtop System |
| Wavenumber Range | 760–4400 cm⁻¹ |
| Spatial Resolution | <10 nm |
| Spectral Resolution | <2 cm⁻¹ |
| Scan Rate | 10 spectra/sec |
| Signal-to-Noise Ratio | 100:1 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NAKE 750 |
| Price | USD 7,200 (Refurbished) |
| Instrument Type | Benchtop |
| Excitation Source | High-Energy Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Channels | Configurable (up to 32 fixed channels + 4 programmable PMT positions) |
| Operating Environment | 10–40 °C, <80% RH |
| Power Supply | 220 V AC, 16 A, 2.5 kVA |
| Dimensions (L×D×H) | 105 × 85 × 120 cm |
| Weight | 350 kg |
| Brand | NanoAppo |
|---|---|
| Origin | Tianjin, China |
| Model | EasyPeak |
| Type | SERS Enhancement Substrate |
| Substrate Composition | Colloidal Silver (Ag) and Colloidal Gold (Au) Nanoparticle Suspensions |
| Storage Condition | 4 °C |
| Shelf Life | Ag-based: 8 months |
| Au-based | 3.5 months |
| Detection Limit (Ag) | 3 × 10⁻⁶ mol/L (2-mercaptopyridine probe) |
| Detection Limit (Au) | 3 × 10⁻⁹ mol/L (Rhodamine 6G probe) |
| Enhancement Factor (Au) | >10⁹ |
| Compliance | Designed for ASTM E1840-23 and ISO/IEC 17025-compliant Raman workflows |
| Software Compatibility | Compatible with standard Raman spectrometer control software (e.g., Thermo Fisher OMNIC, Horiba LabSpec, Renishaw WiRE) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | NANOCOLOR® UV/VIS Spectrophotometer with Reference Detection Technology (RDT) |
| Wavelength Range | 190–1100 nm |
| Light Sources | Tungsten-halogen lamp (vis) and deuterium lamp (uv) |
| Optical System | Single-beam stabilized optics |
| Wavelength Accuracy | ±1 nm |
| Wavelength Resolution | 0.3 nm |
| Spectral Bandwidth | <4 nm |
| Absorbance Range | ±3.0 E (200–900 nm) |
| Absorbance Accuracy | ±0.005 E (0.0–0.5 E) |
| Absorbance Linearity | <0.5% at 2.0 E |
| Stray Light | <0.05% |
| Measurement Modes | Predefined test methods, absorbance, transmittance, factor, multi-wavelength, kinetics, full-spectrum scan, turbidity |
| Cuvette Compatibility | Round tubes (Ø16 mm outer / Ø14 mm inner), rectangular cuvettes (10, 20, 50 mm pathlength) |
| Data Storage | 1000 GLP-compliant measurements with audit trail |
| Display | Color backlit LCD touchscreen |
| Interface | 1× USB, 2× RS-232 (bidirectional) |
| Environmental Operating Conditions | 10–40 °C, ≤80% RH (non-condensing) |
| Power Supply | 110–240 V AC, 50/60 Hz, 60 VA |
| Dimensions (L×W×H) | 390 × 285 × 155 mm |
| Weight | 6.5 kg |
| Compliance | CE-marked per Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC (incl. 92/31/EEC) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | NanoDrop Lite |
| Optical Design | Dual-Beam |
| Detector | Photodiode Array |
| Wavelength Range | 260–280 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 0.5 nm |
| Wavelength Accuracy | ±0.2% T |
| Stray Light | 0.01% T |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NanoDrop Eight |
| Optical Design | Dual-beam |
| Detector | CCD Array |
| Wavelength Range | 190–850 nm |
| Wavelength Automation | Fully Automatic |
| Spectral Bandwidth | ≤1.8 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% T |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NanoGenius Plus |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Spectral Range | 176–2500 cm⁻¹ |
| Excitation Wavelength | 1064 nm |
| Compliance | FDA 21 CFR Part 11, USP <858>, Ph. Eur. 2.2.48, JP 2.26, ChP 2020 Raman Spectroscopy General Chapter |
| Application Focus | GMP-compliant raw material identity testing (RMIT), incoming material verification, counterfeit detection |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NS1 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Models | EasyPeak™ Au Colloidal Sol, EasyPeak™ Ag Colloidal Sol |
| Price Range | USD 7,000 – 14,000 |
| Instrument Category | SERS Enhancement Reagents (Consumable/Accessory for Raman Spectrometers) |
| Spectral Range | Not Applicable (Substrate-Level Material) |
| Spectral Resolution | Not Applicable |
| Spatial Resolution | Not Applicable |
| Minimum Wavenumber | Not Applicable |
| Spectral Reproducibility | Not Applicable |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | NCS (National Center for Steel & Iron Research) |
| Instrument Type | Floor-standing |
| Excitation Method | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Line Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Analytical Channels | 48 |
| Dispersion | 0.55 nm/mm (1st order), 0.275 nm/mm (2nd order) |
| Optical Resolution | < 0.01 nm |
| Selectable Spectral Lines | 240 |
| Dimensions (W×D×H) | 139 cm × 80 cm × 117 cm |
| Weight | ~400 kg |
| Power Supply | 220 V ±10%, Single-phase, 10 A, 2.5 kVA |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | OPA-1000 |
| Pricing | Upon Request |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Model | OPA-500 |
| Optical System | Czerny-Turner spectrometer with 500 mm focal length |
| Grating | 2700 lines/mm |
| Linear dispersion | 0.7407 nm/mm |
| Spectral resolution | ≤0.01 nm |
| Wavelength range | 160–650 nm |
| Excitation source | High-stability continuous spark source, no pre-burn required |
| Data acquisition rate | 100 kHz |
| Scanning platform | Siemens CNC-controlled 3-axis system (X: 360 mm, Y: 247 mm, Z: 350 mm) |
| Positioning accuracy (bidirectional) | X-axis ±0.016/±0.010 mm, Y/Z-axis ±0.012/±0.010 mm |
| Repeatability (bidirectional) | ±0.008/±0.006 mm (X/Y/Z) |
| Maximum scan area | 300 × 200 mm |
| Sample weight capacity (uniform load) | 200 kg |
| Compressed air requirement | 0.6 MPa |
| Power supply | 220 VAC ±10%, 50 Hz |
| Dimensions (W×D×H) | 1929 × 1428 × 2016 mm |
| Scan patterns | Rectangular, circular, cross (“rice”), sector, and custom-defined contours |
| Data interface | Ethernet |
| Software compliance | Supports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit (Zn at 213.856 nm) | ≤0.003 µg/L |
| Precision (RSD) | ≤0.5% at 1 mg/L (n=10) |
| Short-term Stability (RSD) | ≤0.75% (500×LOD) |
| Long-term Stability (RSD) | ≤1.25% (500×LOD) |
| Wavelength Range | 165–800 nm (2400 g/mm grating) |
| Optical Resolution | ≤0.012 nm (2400 g/mm) |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Plasma 2000 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Zn at 213.856 nm ≤ 0.003 mg/L |
| Repeatability | RSD ≤ 0.5% (1 mg/L, n = 10) |
| Short-Term Stability | RSD ≤ 0.5% (500 × LOD) |
| Long-Term Stability | RSD ≤ 1.0% (500 × LOD) |
| Wavelength Range | 165–950 nm |
| Optical Resolution | 0.007 nm (at 200 nm) |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Plasma 3000 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Sub-ppt to ppt (ng/L–µg/L) |
| Precision | RSD ≤ 0.5% (1 mg/L, n = 10) |
| Short-Term Stability | RSD ≤ 0.5% (500×LOD) |
| Long-Term Stability | RSD ≤ 1.0% (4 h, 500×LOD) |
| Wavelength Range | 165–950 nm |
| Optical Resolution | 0.006 nm @ 200 nm |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 160–500 nm |
| Number of Detection Channels | 128 |
| Power Supply | 220 V ±10%, Single-Phase, 10 A, 2.5 kVA |
| Weight | 80 kg |
| Dimensions (W×D×H) | 470 × 872 × 435 mm |
| CCD Pixel Count | 3648 + 46 |
| Pixel Size | 8 µm |
| Optical Design | Paschen–Runge Mount with Holographic Concave Grating |
| Spectral Resolution (Pixel Level) | 0.005926 nm |
| Linear Dispersion | 0.7407 nm/mm |
| Argon Consumption | 60 mL/min (Standby), Tidal Purge Mode Enabled |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 130–800 nm (enabling detection of N, Li, Na, K, and other elements) |
| Spectral Coverage | Full-spectrum acquisition |
| Pixel Array | 3648 + 46 pixels |
| Pixel Size | 8 µm |
| Optical Architecture | Paschen-Runge mounting with holographic concave grating |
| Temperature Stability | ±0.1 °C via integrated thermostatic shielding |
| Argon Consumption | 60 mL/min in standby mode |
| MTBF | >3000 hours |
| Dimensions (W×D×H) | 470 × 872 × 435 mm |
| Weight | 100 kg |
| Power Requirement | 220 V ±10%, single-phase, 10 A, 2.5 kVA |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | CMOS Array |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 130–800 nm |
| Power Supply | 220 V ±10%, Single-Phase, 10 A, 2.5 kVA |
| Weight | 100 kg |
| Argon Consumption (Standby) | 60 mL/min |
| Optical System | Paschen-Runge Mount with Holographic Grating |
| Temperature Control Precision | ±0.1 °C |
| Startup Time (Cold) | 30 min |
| Startup Time (Hot) | 5 min |
| Brand | Neaspec |
|---|---|
| Origin | Germany |
| Configuration | Near-field infrared and terahertz pump-probe nanoscopy system with visible–NIR excitation and mid-IR/THz detection |
| Spatial Resolution | 20–50 nm |
| Temporal Resolution | down to 50 fs |
| Probe Spectral Ranges | 650–2200 cm⁻¹ (mid-IR) or 0.5–2 THz |
| Pump Laser Compatibility | tunable visible to near-infrared sources |