| Brand | Neaspec |
|---|---|
| Origin | Germany |
| Model | o-FTIR |
| Instrument Type | Laboratory-based FTIR Spectrometer |
| Spatial Resolution | 10 nm |
| Spectral Resolution | 3.0 cm⁻¹ |
| Acquisition Speed | 3 spectra/s |
| Signal-to-Noise Ratio | 80:1 |
| Spectral Range | 0.5–20 µm (Visible to Mid-IR) |
| Illumination Mode | Reflection-mode AFM tip illumination |
| Detection | Interferometric scattering near-field detection with background-free architecture |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SWS6211 |
| Spectral Range | 1250–2500 nm |
| Interface | USB 2.0 |
| Detector | Single-element InGaAs photodiode |
| Optical Coupling | Fiber-optic (SMA 905 connector) |
| Power Consumption | <1.5 W |
| Dimensions | 72 × 52 × 32 mm |
| Weight | <120 g |
| Compliance | CE, RoHS, FCC Class B |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | Nicolet 6700, Nicolet 8700 |
| Instrument Type | Fourier Transform Infrared (FT-IR) Spectrometer |
| Spectral Range | 27,000–15 cm⁻¹ |
| Resolution | 0.09 cm⁻¹ (max), 0.4 cm⁻¹ (standard) |
| SNR | 50,000:1 (peak-to-peak, 1-min scan) |
| Interferometer | Digitally Controlled ETC-Driven VECTRA™ with 130,000 dynamic adjustments/sec |
| Light Source | Electronically Temperature-Controlled (ETC) EverGlo™ IR Source (US Patent #US5291022) |
| Detector Options | Plug-and-Play Mid-IR, Far-IR, UV-Vis, and Liquid-Nitrogen-Cooled MCT (18-h hold time) |
| Data Interface | USB 2.0 |
| Software Platform | OMNIC™ with FDA 21 CFR Part 11 Compliance Support |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | Nicolet FT-SPR |
| Pricing | Available Upon Request |
| Brand | NLIR |
|---|---|
| Origin | Denmark |
| Model | S2050-400 / S2050-1k / S2050-130k |
| Spectral Range | 2.0–5.0 µm |
| Full-Spectrum Readout Rate | up to 130 kHz |
| Sensitivity | −80 dBm/nm |
| Resolution | down to 2.5 cm⁻¹ (2048-pixel detector array) |
| Input | fiber-coupled (SMF-28, FC/PC optional) |
| Software Interface | native GUI + MATLAB/Python/C (DLL) APIs |
| Compliance | compatible with GLP/GMP data integrity workflows via timestamped, audit-trail-enabled acquisition logs |
| Brand | NLIR |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | S76120 Prototype |
| Spectral Range | 7.6–12 µm |
| Resolution | 8–10 cm⁻¹ |
| Full-Spectrum Readout Rate | 50 Hz |
| Sensitivity (Full Aperture) | 200 pW/nm (−67 dBm/nm) |
| Exposure Time | 1–200 ms |
| Field of View (FWHM, full angle) | 2.1° |
| ADC Bit Depth | 14-bit |
| Dark Noise RMS (100 ms) | 7 counts |
| Minimum Detectable Power (100 ms) | 200 pW/nm |
| Input Interface | Free-Space Optical |
| Polarization Sensitivity | Vertical |
| Max Operating Temperature | 30 °C |
| Dimensions (H×L×W) | 100 × 306 × 200 mm³ |
| Weight | 5 kg |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N25E-SWIR |
| Price | Upon Request |
| Spectral Range | 1000–2500 nm |
| Spectral Resolution | 10 nm |
| Spectral Sampling Interval | 6.3 nm |
| Effective Slit Length | 9.6 mm |
| Optical Throughput Efficiency | >50% |
| Relative Aperture | f/2.0 |
| Slit Width | 30 µm |
| Stray Light Level | 0.5% |
| Detector Type | Mercury Cadmium Telluride (MCT) |
| Detector Cooling | Thermoelectric (TE) |
| Full-Frame Pixel Count | 320 × 256 (240 active rows) |
| Pixel Size | 30 × 30 µm |
| A/D Output | 14-bit |
| Dynamic Range | 800:1 |
| Frame Rate (Full Frame) | 100 fps |
| Exposure Time Range | 0.1–20 ms |
| Computer Interface | LVDS |
| Lens Mount | C-Mount |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | OBLF GS1000 II |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–780 nm |
| Number of Channels | 32 |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Channels | 64 |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | QSN/G 750-II R |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Simultaneous Channels | 64 |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | QSN750-II |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 190–780 nm |
| Number of Analytical Channels | 60 |
| Optical Resolution (1st Order) | 0.55 nm/mm |
| Vacuum Pump Duty Cycle | <5% of total operating time |
| Spark Frequency | Up to 1000 Hz |
| Analysis Time (Steel Sample) | ~15 s |
| Operating Temperature | 12–35 °C |
| Dimensions (L×W×H) | 1040 × 900 × 1300 mm |
| Weight | 550 kg |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | OBLF VeOS |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Detection Channels | 128 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Blue Series |
| Spectral Range | 200–1100 nm |
| Detector | CCD (2048-pixel linear array) |
| Optical Resolution (FWHM) | 0.13–6.0 nm (dependent on grating and slit configuration) |
| Sensitivity | 100 photons/count at 400 nm |
| Signal-to-Noise Ratio | 1000:1 (full well, 1 s integration) |
| Dynamic Range | 2000:1 (6 decades) |
| Stray Light | <0.1% at 435 nm |
| Interface | USB 2.0, SMA905 fiber input, 16-bit ADC |
| Integration Time | 1 ms – 65 s |
| Grating Options | 300–2400 g/mm (holographic & ruled) |
| Slit Options | 14–200 µm |
| Focal Ratio | f/4 |
| Optical Design | Symmetric Czerny–Turner with crossed-beam geometry |
| Power Supply | <100 mA via USB port |
| Dimensions | 25.4 × 76.2 × 127 mm (1 × 3 × 5 in) |
| Weight | 397 g (14 oz) |
| Brand | Ocean Insight |
|---|---|
| Origin | USA |
| Model | FLAME-S / FLAME-T |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS (back-thinned or standard, model-dependent) |
| Optical Resolution (FWHM) | Configurable via slit width and grating selection |
| Sensitivity | Configuration-dependent (e.g., UV-enhanced or NIR-optimized) |
| Signal-to-Noise Ratio | 250:1 (full signal, 10 ms integration) |
| 300 | 1 (with on-chip binning) |
| Dynamic Range | 8.5 × 10⁷ (system, with 16-bit ADC and multi-integration) |
| Stray Light | <0.05% at 600 nm |
| Dimensions | 89.1 × 63.3 × 34.4 mm |
| Weight | 265 g |
| Interface | USB 2.0 (micro-B), no external power required |
| Operating Temperature | 0–40 °C |
| Thermal Drift | <0.03 nm/°C (typical, with onboard thermal stabilization) |
| Brand | Ocean Insight |
|---|---|
| Model | NIRQuest+ |
| Type | Portable Grating-Based Spectrometer |
| Wavelength Range | 900 nm – 2500 nm |
| Detector Cooling | Thermoelectric (TEC) to –20 °C |
| Dark Current | Low |
| Signal-to-Noise Ratio | High |
| Integration Time | Short (ms-scale typical) |
| Optical Compatibility | Fully compatible with Ocean Insight light sources, optical fibers, and sampling accessories |
| Configurations | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCULIBS 2500 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Wavelength | 1064 nm |
| Translation Stage Range | 50 × 50 × 20 mm |
| Positioning Accuracy | ≥1 μm |
| Wavelength Coverage | 180–1037 nm (configurable) |
| Optical Resolution | 0.1 nm (FWHM) |
| Minimum Integration Time | 1 ms |
| Trigger Jitter | ±10 ns |
| Trigger Delay Range | ±450 μs |
| Spectral Channels | 1–8 |
| Gas Control | Solenoid-Valve Actuated Enclosure |
| Imaging | Optional 2× or 5× magnification, fixed-focus optical path |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable options) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window selection) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Optical NA | 0.22 |
| Working Distance | 7.5 mm |
| Display | 4.5″ capacitive multi-touch LCD (720p) |
| Data Interfaces | USB 2.0, Wi-Fi |
| Data Formats | .pdf, .csv, .txt, .jdx, .rdb |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (main unit) |
| Operating Temperature | 0–45 °C |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Numerical Aperture | 0.22 |
| Working Distance | 7.5 mm |
| Display | 4.5″ LCD, 720p capacitive multi-touch |
| Data Interfaces | USB 2.0, Wi-Fi |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (unit) |
| Operating Temperature | 0–45 °C |
| Data Formats | .pdf, .csv, .txt, .jdx, .rdb |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 170–3900 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Detector | Deep-Cooled Back-Illuminated CCD |
| Excitation Wavelength | 785 nm (standard), optional 532 nm or 1064 nm configurations |
| Laser Stability | <±0.02 nm over 8 hours |
| Spectral Reproducibility | <±0.5 cm⁻¹ (RMS, 24 h) |
| Data Interface | USB 3.0 and Wi-Fi 5 (802.11ac) |
| Operating Temperature | 10–40 °C |
| Weight | 1.4 kg (with battery) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Display | 4.5″ 720p capacitive multi-touch LCD |
| Data Interfaces | USB 2.0, Wi-Fi |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (unit) |
| Operating Temperature | 0–45 °C |
| Software Features | Fluorescence background subtraction, spectral similarity matching, quantitative modeling, PDF/CSV/TXT/JDX/RDB export |
| Compliance | ASTM E1840, ISO 8573-1 (for optical path integrity), GLP/GMP-ready audit trail in software log |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Ocean Optics SR2 |
| Spectral Range | 185–1100 nm (configuration-dependent) |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.56–1.71 nm |
| Signal-to-Noise Ratio (SNR) | 380:1 (single acquisition) |
| Dynamic Range | 3400:1 (single acquisition) |
| Integration Time | as low as 10 µs |
| Stray Light | Not specified |
| Slit Options | 5–200 µm |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Principle | Fiber-coupled, non-cooled InGaAs-based dispersive spectroscopy |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Scan Rate | 400 spectra/sec |
| Integration Time | 1 ms – 65 s |
| Sampling Interval | 1 ms – 65 s |
| Measurement Mode | Transmission |
| Detector | Uncooled 128-pixel InGaAs linear array (900–1700 nm response) |
| SNR | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, OceanInsight NIR Chemometrics Suite |
| Compliance | CE, RoHS, FCC Class B |
| Modularity | Interchangeable slits, fiber-optic coupling, OEM-ready architecture |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Principle | Fiber-coupled, non-cooled InGaAs detection |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Scan Rate | 400 spectra/sec |
| Integration Time | 1 ms – 65 s |
| Sampling Interval | 1 ms → 65 s |
| Measurement Mode | Transmission |
| Detector | Uncooled 128-pixel InGaAs array (900–1700 nm response) |
| SNR | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, OmniDriver, NIR chemometrics suite |
| Slit Options | User-replaceable for resolution/sensitivity tuning |
| LED Indicators | Power & acquisition status |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Integration Time | 1 ms – 65 s |
| Scan Rate | 400 spectra/s |
| Detector | Uncooled InGaAs linear array (128 pixels, 900–1700 nm response) |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, NIR Tools, and third-party chemometrics platforms (e.g., MATLAB, Python with Ocean SDK) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Portable Spectrometer |
| Principle | Grating-based Scanning Spectroscopy |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Maximum Scan Rate | ~400 Hz |
| Integration Time | 1 ms – 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Portable NIR Spectrometer |
| Principle | Grating-based Scanning Spectrometer |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Scan Rate | ~400 Hz |
| Integration Time | 1 ms to 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Origin | Shanghai, China |
| Manufacturer | Ocean Optics (Shanghai) |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Handheld NIR Spectrometer |
| Optical Principle | Grating-based Scanning |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Scan Rate | ~400 Hz |
| Integration Time | 1 ms – 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8,000:1 |
| Stray Light | <0.05% at 600 nm |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector | CCD array |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8000:1 |
| Stray Light | <0.05% at 600 nm |
| Display | Monochrome e-ink screen |
| Battery | Removable 4200 mAh Li-ion, >6 h continuous operation |
| Interface | Android-based acquisition app + Windows-compatible spectral processing software |
| Data Export Formats | .txt, .csv, .m |
| Mounting | Adjustable tripod-compatible handle (29–88 cm height range) |
| Integrated features | Motorized shutter, auto-exposure, embedded image/audio annotation |