| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR™ 45m, ReactIR™ 45p |
| Instrument Type | In-situ, Real-time Online FTIR Spectrometer |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Resolution | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 2000:1 |
| Scan Speed | Not specified (typical for high-stability process-grade FTIR) |
| Probe Materials | Diamond, Silicon, Zirconia ATR crystals |
| Wetted Materials | Hastelloy®, Gold |
| Temperature Range | −80 °C to 200 °C (optional up to 300 °C) |
| Pressure Rating | Vacuum to 7 bar (optional up to 350 bar) |
| Probe Diameters | 6.35 mm, 9.5 mm, 16 mm, 25.4 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ReactRaman 802L |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spectral Range | 150–3400 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Spatial Resolution | 2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Repeatability | ±0.2 cm⁻¹ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | UV5 |
| Wavelength Range | 190–1100 nm |
| Detector Type | CCD (Charge-Coupled Device) |
| Optical Design | Dual-Wavelength |
| Wavelength Accuracy | ±1.0 nm |
| Measurement Speed | Full-spectrum scan in <1 second |
| Light Source | Xenon flash lamp |
| Warm-up Time | Zero |
| Automation Level | Fully automated wavelength selection and measurement execution |
| Sample Compartment | Open-access, motor-free design |
| Software Platform | LabX UV-Vis PC software (21 CFR Part 11 / EU Annex 11 compliant) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5, UV7 |
| Optical Design | Single-beam with pulsed xenon lamp |
| Detector | 2048-pixel CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm (UV5), ±0.8 nm (UV7) |
| Stray Light | <0.01% T at 198 nm (KCl) |
| Scan Speed | Full spectrum in ≤1 s |
| Photometric Accuracy | ±0.01 A (K₂Cr₂O₇) |
| Wavelength Resolution (toluene in n-hexane) | >1.5 nm (UV5), >1.9 nm (UV7) |
| Display | 7″ QVGA color TFT touchscreen (400 × 800 px) |
| Dimensions (L×W×H, without controller) | 208 × 255 × 228 mm |
| Weight (with controller) | 6.4 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5 / UV7 / UV5Bio |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.9 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |
| Automation Level | Automatic Wavelength Selection |
| Lamp Type | Xenon Flash Lamp |
| Warm-up Time | None |
| Dimensions | Compact footprint (~A4 size) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5Bio / UV5Nano |
| Optical Design | Dual-wavelength |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light (at 198 nm, KCl) | >2.0 A |
| Scan Time (full spectrum) | 1 s |
| Automation | Automatic wavelength selection, integrated cuvette changer, FillPalMini peristaltic pump |
| Compliance | ASTM E275, ISO 6425, USP <857>, FDA 21 CFR Part 11 ready (via LabX®) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | UV5Nano |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190 nm – 1,100 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.9 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UV5Nano |
| Instrument Architecture | Dual-wavelength |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 nm – 1,100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.01 A |
| Path Length Options | 0.1 mm and 1.0 mm |
| Cuvette Holder | Yes |
| Automation Level | Automatic Wavelength Selection |
| Sample Volume Requirement | As low as 0.3 µL |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MFS-12 |
| Quotation | Upon Request |
| Focal Length | 500 mm |
| Spectral Range | 190–425 nm |
| Detector | 10 linear CCD arrays, 3648 pixels each |
| Sample Stage | Universal design for solid metals, rods, wires, and pressed powders (e.g., ores, oxides, ferroalloys, slags) |
| Excitation Source | Computer-controlled low-voltage spark generator |
| Plasma Current | 25–350 A |
| Discharge Duration | 30–600 µs |
| Repetition Frequency | 50–400 Hz |
| Detection Limit | 0.001 wt% |
| Concentration Range | 0.001% to tens of % |
| Relative Standard Deviation | 0.5–5% (concentration-dependent) |
| Analysis Time | 10–40 s per sample |
| Operating Temperature | 15–25 °C |
| Relative Humidity | ≤80% (non-condensing) |
| Power Supply | 220 V ±10%, 50 Hz, single-phase with earth grounding |
| Max. Power Consumption | 2.5 kVA |
| Dimensions (W×H×D) | 834 × 995 × 520 mm |
| Weight | 110 kg |
| Brand | Micheem / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | M4000 |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | MicOS |
| Application | Fluorescence Spectroscopy |
| Grating Configuration | Triple-grating imaging spectrometer with motorized grating turret |
| Spectral Range | 200 nm – 1600 nm |
| Imaging Capability | Integrated digital camera for real-time sample visualization |
| Microscope Orientation | Inverted or side-entry configuration (compatible with cryostats) |
| Excitation Laser Compatibility | 325 nm, 405 nm, 488 nm, 532 nm, 633 nm, 785 nm |
| Objective Options | 10×, 50×, 100× (UV-VIS-NIR optimized) |
| Spot Size | down to <10 µm (dependent on objective and wavelength) |
| Detector Options | Back-illuminated CCD (200–1050 nm), InGaAs array (800–1600 nm), UV-enhanced CCD (190–1100 nm), selectable per spectral segment |
| Software Platform | LabSpec 6 (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready) |
| Brand | Micro Emission |
|---|---|
| Origin | Japan |
| Model | MH-5000 |
| Instrument Type | Full-Spectrum Direct-Reading OES |
| Wavelength Range | 200–860 nm |
| Weight | 1.4 kg (including battery) |
| Power Supply | 6 AA batteries or AC adapter |
| Sample Volume | 40 µL |
| Element Coverage | >40 elements (including Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Cd, Ba, Pb, and rare earths) |
| Brand | Micro Emission |
|---|---|
| Origin | Japan |
| Model | MH-6000A |
| Instrument Type | Full-Spectrum Direct-Reading OES |
| Wavelength Range | 200–860 nm |
| Weight | 4.4 kg |
| Dimensions (L×W×H) | 31 × 16 × 20 cm |
| Power Consumption | 100 W |
| Gas Requirement | None |
| Cooling | Air-Cooled, No Water Circulation |
| Sample Introduction | Peristaltic Pump |
| Detector Configuration | Dual-Detector Array |
| Sample Form | Aqueous Liquids (with Optional Sapphire Flow Cell) |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MicroHSImager |
| Pricing | Available Upon Request |
| Brand | Microlink / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Scientific-grade CMOS array (replacing legacy CCD) |
| Focal Length | 1000 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | 140 nm – 680 nm |
| Number of Simultaneous Detection Channels | 96 |
| Optical System | Dual-chamber vacuum-UV + UV-Vis configuration |
| Structural Material | Stress-relieved die-cast aluminum optical chamber (4-stage annealing) |
| Thermal Management | Active chamber temperature stabilization with laminar purge gas flow |
| Spectral Optimization | RTMC (Real-Time Multi-Channel) calibration and drift compensation algorithm |
| Compliance | Designed to support ISO/IEC 17025 workflows, ASTM E415, ASTM E1086, ASTM E3061, and GB/T 4336–2016 methodologies |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | NIR/MIR |
| Price | Upon Request |
| Wavelength Range (NIR) | 0.6–1.7 µm, 0.9–2.1 µm |
| Wavelength Range (MIR) | 2.5–5 µm, 5–10 µm |
| Spectral Resolution | <9 nm (NIR), <12 nm (NIR), <30 nm (MIR), <50 nm (MIR) |
| Wavelength Accuracy | <0.5 nm (NIR), <2 nm (MIR) |
| SNR | >7000:1 (NIR), >1000:1 (NIR), >500:1 (MIR), >500:1 (MIR) |
| Integration Time | 4 ms |
| Dimensions (NIR) | 107 × 66 × 80 mm |
| Dimensions (MIR) | 107 × 110 × 80 mm |
| Power Supply | 9–18 V DC (NIR), 18–36 V DC (MIR) |
| Interface | USB, RS-485 |
| Detector Cooling | Optional thermoelectric (TE) cooling |
| Input Coupling | Free-space or fiber-optic |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | microPHAZIR AS |
| Price Range | USD 70,000–140,000 (FOB) |
| Principle | Portable, Non-Contact Reflectance NIR Spectroscopy |
| Measurement Time | <10 s |
| Sampling Mode | Non-Contact Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | Ruggedized Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp (Class 1 LED-equivalent Safety) |
| Data Interface | Internal Flash Memory + USB 2.0 Host Interface |
| Operating Temperature | 5–40 °C (non-condensing) |
| Power Supply | Dual Hot-Swappable Li-ion Batteries (4.5 h typical runtime) |
| Optional Accessories | AC Battery Charger, Carrying Case with Belt Clip |
| Brand | GAOMAI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | I-Series |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 4000–7500 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Scan Speed | 8 s per spectrum |
| Signal-to-Noise Ratio | <1% (RMS, 100 scans) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ across 4000–7500 cm⁻¹ |
| Brand | MKS |
|---|---|
| Origin | USA |
| Model | MG6030 |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 10 ppb to 100% (gas-phase concentration) |
| Spectral Resolution | 0.5–128 cm⁻¹ |
| Scan Speed | 5 scans/sec at 0.5 cm⁻¹ |
| Detector | Liquid-nitrogen-cooled or thermoelectrically cooled MCT (HgCdTe) |
| Optical Path Length | 5.11 m |
| Purge Gas | Dry N₂ or CO₂-free air (dew point < −70 °C), flow rate 0.2 L/min |
| Pressure Sensor | MKS Baratron® capacitance manometer |
| Sample Temperature Range | Ambient to 200 °C |
| Sample Flow Rate | 0.2–10 L/min |
| Sample Pressure Range | 0.01–4 atm |
| Enclosure Material | Nickel-plated aluminum or 316 stainless steel |
| Weight | 50 kg |
| Dimensions | 445 mm (W) × 318 mm (H) × 648 mm (D) |
| Power | 110/220 VAC, 50/60 Hz, 3 A |
| Brand | MN Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | PF-12 |
| Wavelength Range | 345–690 nm (7 fixed filters) |
| Optical System | Single-beam filter photometer with filter wheel |
| Photometric Range | ±3 E |
| Accuracy | ±1% absorbance |
| Wavelength Accuracy | ±2 nm |
| Bandwidth | 10–12 nm |
| Detector | Silicon photodiode |
| Light Source | Tungsten lamp |
| Sample Cell | 16 mm round cuvettes |
| Data Storage | 200 GLP-compliant measurements |
| Display | Backlit LCD (64 × 128 pixels) |
| Interface | USB 2.0 |
| Power Supply | AA batteries (rechargeable or alkaline), USB bus power, 12 V automotive adapter, or AC adapter |
| IP Rating | IP67 |
| Operating Temperature | 0–50 °C |
| Dimensions | 215 × 100 × 65 mm |
| Weight | 0.7 kg |
| Compliance | EN 61010-1 (Low Voltage Directive 2006/95/EC), EN 61326-1 (EMC Directive 2004/108/EC), ISO 9001 certified |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | QuickDrop |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Cuvette Compatibility | Yes |
| Brand | MONSTR Sense Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Femtosecond Pump–Probe Spectroscopy |
| Spectral Range | 530–950 nm |
| Spectral Resolution | 0.02 nm |
| Temporal Resolution | 0.3 fs |
| Brand | Montana Instruments |
|---|---|
| Origin | USA |
| Model | CryoRAMAN |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 190 nm – mid-IR (down to 150 nm with custom coatings, gratings & detectors) |
| Spectral Resolution | 0.08 nm (CCD), 0.05 nm (PMT) across entire focal plane |
| Spatial Resolution | ≥15 lp/mm @ 50% modulation (center of focal plane) |
| Minimum Raman Shift | 0.8 cm⁻¹ |
| Temperature Range | 4 K – 350 K (600 K optional) |
| Sample Positional Drift | <20 µm (4.2 K–350 K, optical axis) |
| Excitation Wavelengths | 532 nm (standard), 785 nm (optional), customizable UV–NIR–MIR sources |
| Laser Spot Size | 1–3 µm |
| Field of View | >30 µm |
| Objective NA | 0.75 (Cryo-Optic®) |
| Spectrometer Options | FERGIE® (f/4, 80.08 mm FL) or IsoPlane® SCT320 (f/4.6, 320 mm FL) |
| Polarization-Resolved Capability | Yes (interchangeable polarization filtering modules) |
| Electrical Transport Integration | CryoChip16-compatible, 16-channel DC measurement platform |
| Automation | Fully automated cryostation (Cryostation® S100), touch-screen + PC control |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 490–8500 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Scan Speed | ≤3 s per spectrum |
| Signal-to-Noise Ratio | 15,000:1 |
| Optical Path Design | Low-volume, heated long/short-path gas cell |
| Gas Cell Temperature Control | ±1 °C |
| Operating Ambient | IP50 (optional IP53) |
| Power Supply | 100–240 VAC ±10%, 50–60 Hz ±3 Hz |
| Power Consumption | 550 W (startup), 200 W (steady-state), +400 W (gas cell heater max) |
| Sample Gas Flow Rate | 0–10 LPM |
| Calibration Gas Requirements | Certified standard gases traceable to NIST or equivalent |
| Brand | MPB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | M7 |
| Price Range | USD 9,800 – 14,000 |
| Optical Design | Dual-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190 – 1100 nm |
| Wavelength Scanning Mode | Motorized Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| [Brand | MPB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Scanning | Motorized & Auto-Calibrated |
| Light Source | Pulsed Xenon Lamp (No Preheating Required)] |
| [Brand | MPB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Compliance | ISO/IEC 17025-compatible validation protocols supported] |
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Quasi-Double-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Display | 5-inch Capacitive Color Touchscreen |
| Sample Compartment Design | Removable Front Panel, Damped Hinged Lid (0–120° Position Hold), Integrated Spill Drain Port |
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | M9 |
| Price Range | USD 9,800 – 14,000 |
| Optical Design | Dual-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190 – 1100 nm |
| Wavelength Scanning | Motorized & Auto-Calibrated |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | P2 |
| Price Range | USD 1,400 – 2,800 |
| Optical Configuration | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 195 – 1050 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.8 nm |