Thermal Analysis Instruments
Filter
Showing 751–780 of 922 results
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | THEMYS HP |
| Temperature Range | Ambient to 1200 °C |
| Pressure Range | Up to 150 bar |
| Sample Capacity | 35 g |
| Balance Sensitivity | 0.0023 µg |
| Baseline Drift | ±200 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Crucible Volume | 1300 µL |
| Gas Configuration | 3-channel mass flow controlled (2 MFCs standard with auxiliary gas option) |
| Vacuum Capability | <1 mbar (primary), <5×10⁻² mbar (forced) |
| Safety Compliance | EU PED 2014/68/EU, Group 2 gases |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS LV |
| Temperature Range | Room Temp to 2000 °C (TGA/DTA/TG-DTA), up to 1600 °C (TG-DSC/DSC/TMA) |
| Sample Capacity | Up to 100 g / 18.1 mL |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–20 K/min |
| Maximum Crucible Volume | 18.1 mL |
| TMA Resolution | 1.6 nm |
| TMA Measurement Range | ±6 mm |
| Gas Control | 3-channel MFC-controlled gas lines (including optional corrosive gas path) |
| Vacuum Capability | Primary vacuum (< 5×10⁻² mbar), secondary vacuum optional |
| Balance Load Capacity | ±200 mg (low-load mode), ±2000 mg (high-load mode) |
| DSC/DTA Accuracy | ±2% (heat flow), ±1 °C (temperature, calibrated vs. metal standards) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys One |
| Temperature Range | RT–1150°C / RT–1600°C |
| Heating Rate | 0.01–100 °C/min |
| Atmosphere | Inert or reactive gas |
| Compliance | ASTM E1131, ISO 11358, USP <1227>, ISO 17972 (Cp), GLP/GMP-ready software architecture |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS TMA |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Temperature Range | –150 to 2400 °C (configurable up to 2400 °C with high-temp furnace option) |
| Heating/Cooling Rate | 0–100 °C/min |
| Displacement Resolution | 0.2 nm |
| Displacement Noise | 5 nm |
| Force Range | 0–3.5 N (bidirectional, programmable) |
| Sample Length | 0–20 mm |
| Sample Diameter | ≤10 mm |
| Maximum Displacement Range | ±2 mm |
| Load Capacity | –150 to +350 g (equivalent force range) |
| Probe Options | Compression, Penetration, 3-Point Bending, Tensile, Dilatometric, and Volumetric probes |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | uSC |
| Temperature Range | -40 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–1.2 K/min |
| Calorimetric Channels | 4 (2 sample + 2 reference) |
| Sample Cell Volume | 850 µL |
| Baseline Noise | 0.2 µW RMS |
| Sensitivity (Joule effect at 30 °C) | 100 µV/mW |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% RMS |
| DSC Resolution | 0.02 µW / 0.002 µW |
| Pressure Range (measurable & controllable) | 400 bar (5800 psi) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Manufacturer | AlyXan (co-developed with SETARAM) |
| Model | VistoMS |
| Detection Principle | Fourier Transform Ion Cyclotron Resonance Mass Spectrometry |
| Mass Range | up to 300 u |
| Mass Accuracy | ≤ 0.01 u |
| Detection Limit | sub-ppm (parts per million) |
| Ionization Mode | Soft chemical ionization (e.g., H₃O⁺ reagent ions) |
| Vacuum Architecture | Dual-stage differential vacuum system (atmospheric pressure interface → primary vacuum → secondary high vacuum measurement region) |
| Sample Introduction | Direct coupling to thermal analyzer (TGA, DSC, or TGA-MS compatible platforms) |
| Measurement Duration per Scan | ~2 seconds |
| Environmental Control | Humidity-regulated gas atmosphere capability |
| Quantification | Calibration-free relative quantitation across full mass range |
| Compatibility | Real-time evolved gas analysis (EGA) for organic and polymeric materials |
| Brand | SETARAM |
|---|---|
| Model | Setline STA / Setline STA+ |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 0.01–50 °C/min |
| Temperature Stability | ±0.05 °C |
| Max Sample Mass | 20 g |
| Atmosphere Options | Air, O₂, Inert (N₂, Ar) |
| Balance Resolution | 0.02 µg |
| TG Dynamic Range | ±200 mg / ±1000 mg |
| DSC Sensitivity | 1 µW |
| DSC Enthalpy Accuracy | ±1% |
| Optional Autosampler | 49-position |
| Cooling Method | Water-cooled furnace liner |
| Software | Calisto 2.0 (Data Acquisition & Processing) |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (assembled with French-imported core components) |
| Model | Setline-dsc |
| Temperature Range | –170 to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified metal standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SD-L2 |
| Sample Capacity | Multi-sample simultaneous measurement |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −100 °C to 600 °C |
| Programmable Temperature Control | Heating, Isothermal, Cooling |
| Heating/Cooling Rate | 0.1–100 K/min |
| Scan Modes | Dynamic heating, dynamic cooling, isothermal hold |
| Temperature Accuracy | ±0.01 °C (typical, calibrated per ASTM E794 & ISO 11357-1) |
| Baseline Stability | <0.5 µW over 30 min at 50 °C |
| Sensor Resolution | 0.01 µW |
| Temperature Sensing | Dual independent platinum RTD sensors (furnace + sample) |
| Control Algorithm | Adaptive dynamic PID with FTC/STC dual-mode selection |
| Data Acquisition | 1–10 Hz user-selectable sampling rate |
| Communication Interface | USB 2.0 with auto-reconnect protocol |
| Atmosphere Control | Dual independent gas channels (N₂, O₂, Ar, air), software-switched via solenoid valves |
| Calibration Standards | Indium, Zinc, Tin, and Sapphire (per ISO 11357-2) |
| Brand | YDWG (Shanghai Physical Optics) |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-4 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | Adjustable, up to 320 °C |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ≤±1 °C (<200 °C) |
| Capillary Tube Length | 90 mm |
| Sample Capacity | 1 sample |
| Temperature Resolution | 1 °C |
| Display | LED digital readout (0.1 °C minimum increment) |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 80 W |
| Optical Configuration | Binocular stereomicroscope with 45° inclined dual eyetubes, adjustable interpupillary distance and right-eye diopter compensation |
| Total Magnification | 40× (4× objective + 10× eyepiece) |
| Working Distance | Optimized for thermal stage integration |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-4A |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.5–20 °C/min |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ±0.5 °C |
| Capillary Dimensions | OD Φ1.4 mm, ID Φ0.9 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-5 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ±0.5 °C (<200 °C), ±1 °C (≥200 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 0.9 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Brand | YDWG (Shanghai Physical Optics) |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-2A |
| Temperature Range | Ambient to 300 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 selectable steps) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 3 capillaries per run |
| Display | Dot-matrix LCD with keypad input |
| Calibration | Multi-point PT100-based calibration |
| Interface | RS232 and USB |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 360 × 290 × 170 mm |
| Net Weight | 9 kg |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | SQW-II-14 |
| Price Range | USD 7,000 – 14,000 |
| Temperature Range | Ambient to 1350 °C (short-term up to 1400 °C) |
| Max Load Capacity | 0–28.29 MPa (0–2000 kgf) |
| Deformation Measurement Range | 0–5 mm (resolution: 0.01 mm) |
| Force Accuracy | ±1 % FS |
| Deformation Accuracy | ±1 % FS |
| Heating Rate | Programmable, two-segment linear ramp |
| Furnace Type | Silicon Carbide (SiC) tube furnace, bore Ø50 mm, power 2.5 kW |
| Loading Speed | 0.8–8 mm/min (manually adjustable) |
| Dimensions (main unit) | 720 × 500 × 1644 mm |
| Weight | 500 kg |
| Power Consumption | <3 kW |
| Ambient Operating Conditions | 0–40 °C, RH <85 %, 220 V ±10 %, 50 Hz, grounded supply, no strong magnetic fields/vibration/corrosive gases |
| Control System | PC-based real-time control with data acquisition, automated report generation, and SQL-compatible database storage |
| Mechanical Drive | Precision ball-screw loading mechanism |
| Sample Geometry | Ø30 × 50 mm truncated cone |
| Compliance | Designed for ASTM E228, ISO 7991, GB/T 4339, and DIN 51045 testing protocols |
| Software Features | GLP-compliant audit trail, user-level access control, experimental sequence scripting, export to CSV/PDF/Excel |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SJY-II-14/17 |
| Price Range | USD 1,400–7,200 (FOB) |
| Max. Temperature | 1400 °C / 1700 °C |
| Heating Rate | 0–10 °C/min |
| Temp. Accuracy | ±1 °C |
| Sample Dimensions | Ø6 mm × 8 mm (cylindrical) |
| Linear Measurement Range | 5 mm |
| Resolution | 0.1 nm |
| Atmosphere Options | Vacuum (≤1.0×10⁻² Pa), Inert Gas (N₂, Ar), or Ambient Air |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TMA-60/60H |
| Temperature Range | Ambient to 1000 °C / 1500 °C (optional cryo stage down to −150 °C) |
| Displacement Range | ±5 mm |
| Load Range | ±5 N |
| Sample Dimensions | Ø8 mm × 20 mm (cylindrical) or 5 mm (W) × 1 mm (T) × 20 mm (L) (rectangular) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Sigmameter |
| Sample Max Dimension | Ø30×20 mm |
| Magnetic Field Gap | 800 kA·m⁻¹ (10,000 Oe) |
| Sensitivity | 1 mg Co |
| Accuracy | ±1% |
| Measurement Time | 5 s |
| Units Supported | emu·g⁻¹ (Gauss·cm³·g⁻¹), SI (µT·m³·kg⁻¹), Co wt% |
| Automation | Fully Automated |
| Maintenance | Maintenance-Free Design |
| Compliance | Designed for ISO/IEC 17025-aligned QC labs |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Opti-Melt100 |
| Price | ¥56,500 (CNY) |
| Temperature Range | −10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min (adjustable in 0.1 °C/min increments) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.3 °C (≤100 °C), ±0.5 °C (≤250 °C), ±0.8 °C (≤400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Sample Capacity | 2 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Heating Time | 10 min (50 °C → 350 °C) |
| Cooling Time | 10 min (350 °C → 50 °C) |
| Display | Touchscreen LCD |
| Interface | USB, RS-232 |
| Software | Melt-View™ (Windows-compatible) |
| Power Supply | AC 90–264 V |
| Operating Temperature | 0–40 °C |
| Weight | 4.1 kg |
| Dimensions | 20 × 25 × 21 cm |
| Brand | SRS / Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | OptiMelt MPA100 |
| Temperature Range | RT+10°C to 400°C |
| Heating Rate | 0.1–20.0°C/min (0.1°C/min increments) |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.3°C (≤100°C), ±0.5°C (≤250°C), ±0.8°C (≤400°C) |
| Temperature Repeatability | ±0.3°C |
| Capillary Dimensions | OD 1.4–2.0 mm, Length 100 mm |
| Sample Capacity | 3 channels simultaneously |
| Cooling Time | 10 min (350°C → 50°C) |
| Heating Time | 10 min (50°C → 350°C) |
| Display | Touchscreen LCD |
| Interface | USB, RS-232 |
| Software | MeltView™ for Windows |
| Power | 90–264 VAC |
| Weight | 4.1 kg |
| Dimensions | 20 × 25 × 21 cm |
| Brand | Stuart |
|---|---|
| Origin | UK |
| Model | SMP10 |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 1 °C |
| Accuracy | ±1.0 °C at 20 °C, ±2.5 °C at 300 °C |
| Heating Rate | 20 °C/min (pre-heat), 2 °C/min (melting determination) |
| Display | 3-digit LED |
| Sensor | PT100 platinum resistance thermometer |
| Sample Capacity | 2 capillaries simultaneously |
| Dimensions (W×D×H) | 160 × 220 × 170 mm |
| Net Weight | 1.8 kg |
| Power Supply | 230 V / 50 Hz, 75 W |
| Includes | 100 sealed-end capillary tubes (SMP10 kit) |
| Brand | Stuart |
|---|---|
| Origin | United Kingdom |
| Model | SMP30 |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 0.5–10.0 °C/min (adjustable in 0.1 °C increments) |
| Cooling Time (350 °C → 50 °C) | 12 min |
| Heating Time (50 °C → 350 °C) | 6 min |
| Sample Capacity | 3 capillaries simultaneously |
| Temperature Memory | 8 readings per sample |
| Display | 40×4 character LCD |
| Sensor | PT100 platinum resistance thermometer |
| Power Supply | 230 V, 50 Hz, 60 W |
| Dimensions (W×D×H) | 325 × 200 × 170 mm |
| Net Weight | 3.6 kg |
| Capillary Storage Compartment | Integrated |
| Observation Chamber | Dual-height adjustable |
| Illumination | Integrated high-intensity LED lighting |
| Surface Finish | Biocote® antimicrobial coating |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMP30 |
| Price Range | USD 1,400–2,800 |
| Sample Capacity | 3 capillaries |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.5–10.0 °C/min (0.1 °C increments) |
| Temperature Memory | 8 readings per sample |
| Sensor | PT100 platinum resistance thermometer |
| Cooling | Integrated air pump |
| Dimensions | 325 × 200 × 170 mm |
| Net Weight | 3.6 kg |
| Power Supply | 230 V, 50/60 Hz, 60 W |
| Standard Accessories | Glass capillary tubes (SMP10/1) |
| Brand | Stuart |
|---|---|
| Origin | United Kingdom |
| Model | SMP40 |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 0.1–10 °C/min (adjustable in 0.1 °C increments) |
| Cooling Time (350 °C → 50 °C) | ≤10 min |
| Heating Time (50 °C → 350 °C) | ≤6 min |
| Sample Capacity | 3 capillaries simultaneously |
| Display | 5.7″ color VGA touchscreen |
| Sensor | PT100 platinum resistance thermometer |
| Data Storage | 200 measurement records with embedded AVI video |
| Compliance | Pharmacopoeial standards (USP <741>, EP 2.2.14, JP 2.60), GLP-ready, includes traceable calibration certificate |
| Dimensions (W×D×H) | 175 × 210 × 328 mm |
| Net Weight | 3.2 kg |
| Power Supply | 230 V / 50 Hz / 60 W |
| Capillary Storage Compartment | Yes |
| Glass Tool Storage Compartment | Yes |
| Antimicrobial Surface Coating | Biocote® silver-ion technology |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMP40 |
| Price Range | USD 4,200–7,000 (est.) |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–10.0 °C/min (adjustable in 0.1 °C increments) |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Capillary Length | 100 mm |
| Sample Capacity | 3 samples simultaneously |
| Temperature Resolution | 0.1 °C |
| Cooling Time (350 °C → 50 °C) | ≤10 min |
| Heating Time (50 °C → 350 °C) | ≤6 min |
| Display | 5.7″ color VGA touchscreen |
| Sensor | PT100 platinum resistance thermometer |
| Data Storage | 200+ test records with full AVI video capture |
| Power Supply | 230 V / 50 Hz, 60 W |
| Dimensions (W×D×H) | 175 × 210 × 328 mm |
| Net Weight | 3.2 kg |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SDAC1000 |
| Pricing | Upon Request |
| Intelligence Level | Fully Automated |
| Instrument Type | Isoperibol Oxygen Bomb Calorimeter |
| Temperature Measurement Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Heat Capacity Precision | ≤0.10% RSD |
| Heat Capacity Stability | ≤0.20% drift over 12 months |
| Single Test Duration (Fast Mode) | <11 min |
| Single Test Duration (Classical Mode) | <13 min |
| Max Power Consumption | 0.65 kW |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (Main Unit) | 428 mm × 565 mm × 450 mm |
| Weight (Main Unit) | ~45 kg |
| Water Jacket Dimensions | 220 mm × 565 mm × 410 mm |
| Water Jacket Weight | ~25 kg |
| Compliance | GB/T 213-2008, GB/T 384-1981, GB/T 30727-2014, ASTM D5865-2007, JC/T 1005-2006, ISO 1928-2020 |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Principle | Isoperibol (Constant-Temperature Jacket) Calorimetry |
| Compliance Standards | GB/T 213-2008, GB/T 384-1981, GB/T 30727-2014, ASTM D5865-2007, ISO 1928-2020, JC/T 1005-2006 |
| Single Test Duration (Rapid Mode) | <11 min |
| Temperature Resolution | 0.0001 °C |
| Heat Capacity Precision | ≤0.10% RSD |
| Heat Capacity Drift | ≤0.20% per year |
| Ignition Methods | SDAC1600 – Ignition Rod |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Max Power Consumption | 0.65 kW |
| Host Dimensions (SDAC1600) | 439 × 565 × 485 mm |
| (SDAC1200/SDAC1600L) | 390 × 565 × 485 mm |
| Water Bath Dimensions | 220 × 565 × 410 mm |
| Host Weight | ~50 kg |
| Water Bath Weight | ~25 kg |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Model | SDACM3200 |
| Measurement Mode | Isoperibolic Calorimetry |
| Instrument Type | Oxygen Bomb Calorimeter |
| Temperature Resolution | 0.0001 °C |
| Thermal Capacity Stability | ≤0.25% over 3 months |
| Thermal Capacity Precision | ≤0.15% RSD |
| Single Test Duration | ≤15 min |
| External Jacket Temperature Drift | <0.1 °C per test |
| Max Power Consumption | 0.15 kW |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (Main Unit) | 500 × 600 × 425 mm |
| Weight (Main Unit) | ~65 kg |
| Water Jacket Dimensions | 550 × 356 × 520 mm |
| Water Jacket Weight | ~17.5 kg |
| Compliance | GB/T 213–2008, GB/T 384–1981, GB/T 30727–2014, ASTM D5865–2007, ISO 1928–2009, JC/T 1005–2006 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Affinity ITC / ITC Auto |
| Temperature Range | 2–80 °C |
| Cell Volume Options | 1.0 mL (standard) or 190 µL (low-volume) |
| Sample Throughput | Multi-sample via integrated 96-well autosampler |
| Temperature Control | Active solid-state heating/cooling with ±0.01 °C stability |
| Automation Level | Fully automated titration, injection, cleaning, and cell positioning |
| Compliance | Designed for GLP/GMP environments |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 801 / DIL 801L |
| Configuration | Horizontal, single-sample dilatometer |
| Operating Atmosphere | Air, vacuum, or inert gas (N₂, Ar) |
| Temperature Range | −150 °C to 1600 °C (dependent on furnace and sensor option) |
| Force Control | User-adjustable contact force from 0.02 N to 1.00 N |
| Sensor Type | High-stability LVDT with digital signal conditioning |
| Compliance | ASTM E228, ISO 11359-1/-2, DIN 51045-1, USP <671> |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 802/802L |
| Measurement Principle | True Mechanical Differential Expansion Detection |
| Sensor Type | High-Stability LVDT with Digital Amplification |
| Contact Force Range | 0.02–1.00 N (User-Adjustable) |
| Configuration | Convertible Between Differential and Single-Sample Modes |
| Thermal Uniformity | Optimized Horizontal Furnace Design |
| Vibration Resistance | Integrated Mechanical Isolation Architecture |
| Compliance Ready | Designed for GLP/GMP environments with audit-trail-capable software integration |