Thermal Analysis Instruments
Filter
Showing 331–360 of 922 results
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HFM-GP10 |
| Price Range | USD 7,000 – 14,000 |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Models | KR2 (100×50 mm), KR6 (50×30 mm), KM1 (30×15 mm), K500B / K500B-20 (black, high-heat-flux surface-mount), K500S / K500S-20 (silver), K750 / K750S (embedded high-heat-flux), KW (water-cooled surface), TF-B/TF-C (robust embedded), TT-B/TT-C (robust surface), TC-B/TC-C (robust low-flux embedded), TV-B/TV-C (robust water-cooled) |
| Thermal Flux Ranges | 12–3,500 W/m² (low-flux) |
| Operating Temperature Ranges | −40–150°C (low-flux) |
| Accuracy | ±2% (low-flux), ±5% (surface high-flux), ±7% (embedded high-flux) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-11N / PD-11 |
| Measurement Principle | Transient Hot-Wire Method |
| Thermal Conductivity Range | 0.03–12 W/(m·K) |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Sample Dimensions (min.) | 100 × 50 × 20 mm (for bulk solids) |
| Probe Form Factor | Encapsulated box-type sensor |
| Physical Dimensions (L×W×H) | 110 × 50 × 100 mm |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-13N / PD-13 |
| Measurement Principle | Hot Wire Method |
| Dimensions (L×W×H) | 110 × 50 × 100 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.03–12 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Sample Size Requirement | ≥100 × 50 × 20 mm (sheet form) |
| Minimum Thickness for Film Samples | 0.1 mm (for k = 0.1 W/m·K), 5 mm (for k = 5 W/m·K) |
| Compatible With | QTM-710/QTM-700 (PD-13N), QTM-500 (PD-13) |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | PD-31N / PD-31 |
| Measurement Principle | Transient Hot Wire Method |
| Dimensions (L×W×H) | 100 × 50 × 20 mm |
| Thermal Conductivity Range | 0.058–5.0 W/(m·K) |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Operating Temperature Range | −100 to +1000 °C |
| Measurement Duration | 100–120 s |
| Sample Dimensions | ≥100 × 80 × 40 mm (minimum two specimens) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-NO |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Dimensions (L×W×H) | 262 × 276 × 158 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.0116–0.1 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −100 to +180 °C |
| Standard Measurement Time | 40 s |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | QTM-710 / QTM-700 |
| Measurement Principle | Transient Hot Wire Method |
| Sample Form | Solid (bulk or sheet), including thin films (QTM-710 only) |
| Thermal Conductivity Range | 0.03–12 W/(m·K) |
| Repeatability | ±3% |
| Accuracy | ±5% (vs. certified reference materials at 23 °C) |
| Dimensions (L×W×H) | 262 × 276 × 158 mm |
| Weight | ~4 kg |
| Measurement Time | 60 s per test |
| Display | 5.7-inch color touchscreen |
| Operating Environment | 5–35 °C, <85% RH |
| Power Supply | DC 24 V / AC 100–240 V, 50/60 Hz |
| Interface | 2 × RS-232C, 2 × USB |
| Data Export | CSV via USB flash drive |
| Compliance | ASTM D5470, ISO 22007-2, GB/T 10297-2015, GB/T 5990-2006, GB/T 42919.1-2023, JJF 2221-2025 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QTM-PA1 |
| Measurement Principle | Transient Hot Wire Method |
| Dimensions (L×W×H) | 262 × 276 × 158 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.03–12 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | SOFT-QTM |
| Measurement Principle | Transient Hot-Wire Method |
| Dimensions (L×W×H) | 300 × 475 × 175 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.023–12 W/m·K |
| Repeatability | ±3% |
| Sample Thickness Compatibility | 30 µm – 10 mm |
| Supported Sample Thermal Conductivity Range (Software-Calibrated) | 0.035–5.0 W/m·K |
| Key | Brand: Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | TM-17 |
| Heating Control Modes | Constant Temperature & Constant Power |
| Segment Count | 17 anatomical segments (head, torso, arms, legs) |
| Surface Emissivity | 0.9 (matte baked finish) |
| Segmental Heat Output Range | 0–5 met (0–290 W/m²) |
| Operating Ambient Temperature Range | −20 °C to +60 °C |
| Segmental Temperature Sensors | Precision nickel-wire RTDs |
| Structural Material | Fiberglass-reinforced thermoset resin |
| Joint Articulation | Shoulder, hip, and knee joints with full flexion capability |
| System Weight | ~25 kg |
| Controller Input Voltage | DC 48 V |
| Safety Features | Overheat cutoff (>60 °C), emergency stop button, thermal fusing |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | WBGT-203B |
| Price | Upon Request |
| WBGT Range | 0–50°C |
| Air Temperature Range | 0–50°C |
| Relative Humidity Range | 10–90% RH |
| Black Globe Temperature Range | 0–60°C |
| WBGT Accuracy | ±2°C (15–35°C) |
| Air Temp Accuracy | ±1°C (15–40°C) |
| RH Accuracy | ±3% RH (30–90%) |
| Black Globe Accuracy | ±1°C (20–60°C) |
| Alarm | Yes |
| Battery Life | ~70 hours continuous operation |
| Power Supply | Two AAA alkaline batteries (1.5 V each) |
| Weight | ~110 g |
| Accessories | Carrying case, batteries, operator manual |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | WBGT-301 |
| Price | Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | WBGT-302 |
| Pricing | Available Upon Request |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | KSP1D / KSP1N |
| Temperature Range | 30–360 °C |
| Accuracy | ±0.3 °C (30–200 °C), ±0.5 °C (200–360 °C) |
| Heating Rate | 1 °C/min |
| Optical Magnification | 10× |
| Capillary Capacity | 3 capillaries |
| Capillary Dimensions | 80 mm length × 1.4 mm OD × 0.8 mm ID |
| Cooling | Integrated fan-assisted rapid cooling |
| Display | Backlit LCD with real-time temperature and status |
| Interface | RS-232 |
| Power Supply | 90–264 V AC, 40 W |
| Safety Rating | IP20 |
| Weight | 2.3 kg |
| Language Support | English & German (UI + error messages) |
| Printer | Built-in thermal printer (KSP1D only) |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | M3000 & M5000 |
| Temperature Range | 25–400 °C |
| Heating Rate | 4 min to 300 °C, 7.5 min to 400 °C |
| Temperature Repeatability | ±0.2 °C |
| Temperature Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Capillary Dimensions | 1.4 mm OD |
| Sample Capacity | 1 capillary per measurement |
| Temperature Resolution | 0.1 °C |
| Optical Magnification | 10× |
| Cooling | Integrated fan-assisted rapid cooling |
| Display | Backlit LCD with real-time temperature and status |
| Interface | RS-232 |
| Power Supply | 90–264 V AC, 40 W |
| Ingress Protection | IP20 |
| Weight | 2.3 kg |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | M5000 |
| Temperature Range | 25–400 °C |
| Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Repeatability | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 4 min to 300 °C, 7.5 min to 400 °C |
| Capillary Diameter | 1.4 mm |
| Sample Capacity | 1 capillary per measurement |
| Cooling | Integrated fan-assisted cooling |
| Safety Rating | IP20 |
| Dimensions | 230 × 210 × 110 mm |
| Weight | 1.8 kg |
| Power Supply | 85–264 V AC, 47–440 Hz |
| Interface | RS-232 |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Isoperibol |
| Temperature Range | 0–80 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ≤0.10% RSD |
| Single-Sample Analysis Time | ≤5.5 min |
| Heat Capacity Calibration Range | 35,000 kJ/kg |
| Outer Water Jacket Volume | 12 L |
| Inner Water Bucket Volume | 6 L |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TGA801 |
| Price | Upon Request |
| Temperature Range | 100 °C to 1000 °C |
| Temperature Accuracy | ±0.5 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | Up to 15 K/min |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | DSC600 |
| Temperature Range | −196 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | up to 130 °C/min |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS350V |
| Temperature Range | −196 °C to +350 °C (with LN₂ cooling) |
| Vacuum Range | Down to 10⁻³ mbar |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Temperature Stability | < ±0.1 °C |
| Sensor | 100 Ω Pt RTD |
| Sample Area | Ø22 mm |
| XY Translation Range | 16 mm |
| Optical Aperture | Ø1.3 mm |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DSC L64 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −50 to 160 °C (standard) |
| Heating/Cooling Rate | 0.001–10 K/min (standard) |
| Temperature Accuracy | ±100 µ°C |
| Sensitivity | 550 µV/mW (25 °C) |
| Sample Volume | 5–100 µL (standard) |
| Sensor Technology | Patented high-sensitivity thermopile-based sensor with direct sample temperature measurement and Joule-effect calibration |
| Sample Holder | Removable, hermetically sealed crucible |
| Dimensions (W×D×H) | 900 × 700 × 500 mm (standard) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | Chip-DSC 1 (Chip-DSC L66 Basic) |
| Instrument Type | DSC |
| Temperature Range | RT to 450 °C (no active cooling unit) |
| Heating/Cooling Rate | 0.001–100 K/min |
| Temperature Accuracy | ±0.2 K |
| DSC Signal Range | ±2.5–±1000 mW |
| Temperature Repeatability | ±0.02 K |
| Heat Flow Resolution | 0.03 µW |
| Atmosphere Options | Inert or oxidative (static/dynamic) |
| Calibration | Supplied with certified reference materials |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | Chip-DSC 10 (Chip-DSC L66 Advanced) |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –180 to 600 °C (with optional quench cooling) |
| Temperature Accuracy | ±0.2 K |
| Temperature Precision | ±0.02 K |
| Heating/Cooling Rate | 0.001–300 K/min (up to 500 K/min ballistic cooling from 400 °C) |
| DSC Signal Range | ±2.5 to ±1000 mW |
| Thermal Resolution | 0.03 µW |
| Digital Resolution | 16.8 million data points per trace |
| Atmosphere Options | Inert or oxidative (static/dynamic) |
| Calibration Frequency | Recommended every 6 months |
| Compliance | ASTM E794, ISO 11357-1 to -7, USP <1163>, GLP-ready audit trail support |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | Chip-DSC 100 (Chip-DSC L66 Ultimate) |
| Instrument Type | DSC |
| Temperature Range | −150 to 600 °C (Peltier, closed-loop internal cooler, or liquid nitrogen cooling) |
| Temperature Accuracy | ±0.2 K |
| Temperature Precision | ±0.02 K |
| Heating/Cooling Rate | 0.001–1000 K/min |
| DSC Signal Range | ±2.5–±1000 mW |
| Heat Flow Resolution | 0.03 µW |
| Atmosphere Control | Inert or oxidative (static/dynamic) |
| Recommended Calibration Interval | Every 6 months |
| Digital Imaging Resolution | 1680 megapixels (optical accessories only) |
| Power Consumption | Up to 80% lower than conventional DSC systems |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Product Type | Dielectric Cure Monitor |
| Compliance | ASTM E2038, ASTM E2039 |
| Channel Options | 1, 2, 4, or 8 simultaneous channels |
| Measurement Modes | AC (1 Hz–100 kHz) and DC (LT-440 model only) |
| Sensor Compatibility | Parallel-plate & interdigitated electrode sensors |
| Operating Temperature Range | Up to 350 °C (with optional fixtures) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L74 HM |
| Temperature Range | –100 °C to 500 °C (RT–500 / 1000 / 1500 / 2000 °C) |
| Heating Rate | 0.01–100 °C/min (dependent on furnace configuration) |
| Field of View | 10 × 14 mm² |
| Measurement Resolution | up to 1 µm |
| Atmosphere Options | inert, reducing, oxidizing, vacuum (optional) |
| Vacuum Level | 10⁻⁵ mbar |
| Compliance Standards | DIN 51730, ISO 540, CEN/TS 15404, ASTM D1857, BS 1016-15, CEN/TS 15370-1, IS 12891, NF M03-048 |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L74 OD |
| Temperature Range | -100 to 2000 °C |
| Heating Rate | 0.01–100 °C/min (dependent on furnace configuration) |
| Field of View | 3.3 × 2.8 mm² |
| Measurement Resolution | 1 µm |
| Atmosphere Options | Oxidizing (optional: reducing, inert, vacuum) |
| Vacuum Level | 10⁻⁵ mbar |
| Compliance Standards | ASTM D1857, ISO 540, DIN 51730, CEN/TS 15370-1, BS 1016-15, NF M03-048, CEN/TR 15404, IS 12891 |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L75 Horizontal / Vertical |
| Temperature Range | −263 °C to 2800 °C |
| Displacement Range | ±2500 µm and ±25000 µm |
| Resolution | 0.03 nm (LVDT) and 0.1 nm (optical encoder) |
| Atmosphere Control | Manual gas dosing or mass flow controllers for 1, 3, or multiple gases |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L75 HP |
| Temperature Range | RT to 1100 °C / RT to 1400 °C / RT to 1800 °C |
| Maximum Pressure | 100 bar / 150 bar (configurable) |
| Vacuum Level | 1×10⁻⁴ mbar |
| Sample Length | up to 50 mm |
| Sample Diameter | φ7 / φ12 / φ20 mm |
| Measurement Range | 500 µm / 5000 µm |
| Resolution | 0.125 nm |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing, Vacuum |
| Optional Accessories | Steam Generator, Mass Flow Controlled Gas Mixing System (MFC), QMS/FTIR Coupling Interface |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L75 Laser |
| Temperature Range | −180–500 °C |
| Heating/Cooling Rate | 0.01–50 K/min |
| Sample Length | up to 20 mm |
| Sample Diameter | up to φ7 mm |
| Measurement Resolution | 0.3 nm |
| Atmosphere Options | inert, oxidizing, reducing, vacuum |