Thermal Analysis Instruments
Filter
Showing 301–330 of 922 results
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-PL |
| Measurement Principle | Steady-State Guarded Hot Plate (ASTM C177, ISO 8302) |
| Thermal Conductivity Range | 0.010–5.000 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Overall Dimensions (L×W×H) | 552 × 550 × 760 mm |
| Origin | Shanghai, China |
| Instrument Type | Guarded Hot Plate Analyzer |
| Compliance | ASTM C177, ISO 8302, GB/T 10294 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-PL |
| Measurement Principle | Guarded Hot Plate (Steady-State Heat Flow Method) |
| Test Standard Compliance | ASTM C177, ISO 8302, GB/T 10294 |
| Thermal Conductivity Range | 0.010–5.000 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Dimensions (L×W×H) | 552 × 550 × 760 mm |
| Power Supply | 220 V AC, 50 Hz |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JB-S |
| Instrument Principle | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 500 × 800 × 1200 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–300 W/(m·K) |
| Repeatability | ±3% |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 500 × 800 × 1200 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–300 W/(m·K) |
| Repeatability | ±3% |
| Instrument Type | Benchtop Thermal Conductivity Analyzer |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-STA-200 |
| Origin | Shanghai, China |
| Type | Benchtop Simultaneous DSC-TGA Analyzer |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| DSC Sensitivity | <0.1 µW |
| TGA Resolution | 0.1 µg |
| Atmosphere Control | Dual-gas (N₂/air) with mass flow controller |
| Sample Capacity | Up to 200 mg |
| Compliance | ASTM E1131, ISO 11358, USP <641>, GB/T 19466 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-TGA-101 |
| Temperature Range | Ambient to 1150 °C (optional upgrade to 1450 °C) |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 1–80 °C/min |
| Balance Capacity | 1 mg–2 g (expandable to 30 g) |
| Isothermal Hold Time | 0–300 min |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic) |
| Data Interface | USB |
| Compliance | ASTM E1131, ISO 11358, USP <41>, GLP-ready software audit trail |
| Brand | Jiubin Instruments |
|---|---|
| Temperature Range | Ambient to 1450 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating Rate | 1–80 °C/min |
| Cooling Time | 15 min (from 1000 °C to 100 °C) |
| Balance Capacity | 1 mg–2 g (expandable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Isothermal Hold Time | 0–300 min |
| Atmosphere Control | Dual-gas manifold with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Interface | USB |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 489 × 400 × 343 mm |
| Brand | JByq |
|---|---|
| Origin | Shanghai, China |
| Model | JB-TGA-1550 |
| Temperature Range | Ambient to 1550 °C |
| Balance Sensitivity | 0.01 µg |
| Heating/Cooling Rate | 0.1–80 K/min |
| Atmosphere | Ambient pressure, dual-gas control (N₂/O₂) |
| Sample Capacity | Single sample, 0.1 mg–2 g (expandable to 50 g) |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Isothermal Duration | 0–300 min adjustable |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Data Interface | USB |
| Software | Proprietary TGA analysis suite with TG/DTG overlay, % mass conversion, Excel export, and report generation |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JHD70 |
| Price Range | USD 4,200 – 7,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Sample Capacity | 4 capillaries per run (2 simultaneously analyzed) |
| Display | Dual-color LCD (3.5″ + 5.6″), >2.5× optical magnification |
| User Accounts | 15 |
| Predefined Methods | 100 |
| Data Interfaces | USB, RS232, Ethernet |
| GLP Compliance | Yes |
| Power Supply | 220 V, 50 Hz, 120 W |
| Standards Compliance | ASTM D3204, D3461, D3954, D6090 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JB-3500F |
| Pricing | Available Upon Request |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JB-3500F |
| Pricing | Available Upon Request |
| Brand | Jiubin |
|---|---|
| Model | JB-3500F |
| Origin | Shanghai, China |
| Instrument Type | Thermal Gravimetric Analyzer (TGA-based) for Polymer Additive Quantification |
| Compliance | ASTM D1606, ISO 6964, GB/T 13021, USP <467> (residual solvent context), GLP-ready architecture |
| Sample Form | Granules, pellets, powder, film fragments |
| Temperature Range | Ambient to 950 °C |
| Heating Rate | 0.1–100 °C/min |
| Balance Resolution | 0.01 mg |
| Atmosphere Control | Dual-gas (N₂/air) switching module |
| Data Output | CSV, PDF, XML |
| Software | Jiubin TGA Pro v3.2 (21 CFR Part 11 compliant audit trail, user role management, electronic signature support) |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-3500F |
| Application | Quantitative carbon black and ash content determination in thermoplastics, elastomers, and cable materials |
| Operating Atmosphere | Nitrogen-purged inert environment with controlled oxidative calcination |
| Temperature Control | Programmable high-precision furnace (up to 950 °C) |
| Measurement Principle | Gravimetric analysis after pyrolytic decomposition and selective oxidation |
| Compliance Basis | ASTM D1606, ISO 6964, GB/T 3512, IEC 60811-4-1 |
| Brand | Jiubin |
|---|---|
| Model | JB-3500F |
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Pricing | Upon Request |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-3500S |
| Origin | Shanghai, China |
| Temperature Range | Ambient to 1100 °C |
| Heating Zone Length | 220 mm |
| Quartz Tube Dimensions | 440 mm (L) × 32 mm (ID) |
| Quartz Boat Options | 50 mm or 75 mm |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.2 °C |
| Heating Rate | 0.1–40 °C/min |
| Gas Flow Control | Digital Mass Flow Controller (0–300 mL/min or 0–2000 mL/min) |
| Gas Pressure Rating | 0.2 MPa |
| Display | 7-inch 24-bit color LCD touchscreen |
| Communication Interface | USB |
| Sample Capacity | Up to 3 specimens simultaneously |
| Exhaust Port Diameter | 12 mm |
| Compliance | GB/T 3515–2005, GB/T 13021–1991, GB/T 2951.41–2008, IEC 60811-4-1:2004 |
| Brand | Jiubin |
|---|---|
| Model | JB-DSC-500B |
| Origin | Shanghai, China |
| Temperature Range | Ambient to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 °C/min (heating), 0.1–10 °C/min (cooling) |
| DSC Sensitivity | 0.1 µW |
| DSC Range | ±500 mW |
| Temperature Resolution | 0.01 °C |
| DSC Accuracy | ±1% |
| Atmosphere Control | Dual-gas (N₂/O₂) mass flow control with automatic switching |
| Interface | USB 2.0 |
| Display | 7-inch 24-bit LED touch screen |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-500B |
| Sample Capacity | 1 |
| Instrument Type | DSC |
| Temperature Range | Ambient to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | ±600 mW |
| Compliance | GB/T 19466.2–2004, GB/T 19466.3–2004, GB/T 19466.6–2009, ISO 11357-2:1999, ISO 11357-3:1999 |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-500B |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | Ambient to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| Sample Capacity | Single-sample configuration |
| Compliance | Designed for ASTM E794, ISO 11357, and USP <1163> thermal analysis workflows |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-600 |
| Sample Capacity | 1 |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sensitivity | 0.01 mW |
| Noise Level | 0.001 mW |
| Thermal Resolution | 0.001 mW |
| Temperature Repeatability | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Gas Flow Control | 0–200 mL/min (0.2 MPa max) |
| Interface | USB |
| Display | 7-inch 24-bit color touchscreen LCD |
| Power Supply | AC 220 V, 50 Hz, 600 W |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JB-DSC-600 |
| Price Range | USD 7,000–14,000 (FOB) |
| Sample Capacity | Single-position |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Sensitivity | 0.01 mW |
| DSC Noise Level | 0.001 mW |
| DSC Resolution | 0.001 mW |
| DSC Accuracy | 0.01 mW |
| Temperature Repeatability | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Gas Flow Control | 0–200 mL/min |
| Gas Pressure Rating | 0.2 MPa |
| Display | 7-inch 24-bit LCD touchscreen |
| Data Interface | Standard USB |
| Calibration | Integrated with certified reference materials and one-click thermal & enthalpy calibration |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 600 W |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-800 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 800 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Display | 7-inch 24-bit color TFT touchscreen |
| Control Core | ARM Cortex-M3 microcontroller |
| Communication | USB 2.0 bidirectional interface |
| Sensor Material | High-stability alloy thermopile |
| Furnace Design | Fully enclosed metallic furnace housing |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DTA-1150 |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 1–80 °C/min |
| DTA Signal Range | 0 to ±2000 μV |
| DTA Sensitivity | 0.01 μV |
| Temperature Resolution | 0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Furnace Type | Top-opening dual-wound Fe-Cr-Al heating element (1 kW) |
| Atmosphere Control | Automated internal gas switching |
| Interface | Standard USB |
| Display | 7-inch 24-bit color LCD touchscreen |
| Calibration | Built-in reference materials with one-click temperature calibration |
| Baseline Adjustment | Adjustable slope and intercept |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-STA-200 |
| Heating Rate | 1–80 °C/min |
| Temperature Range | Ambient to 1150 °C (extendable to 1350 °C) |
| Temperature Stability | ±0.1 °C |
| Atmosphere Options | Inert, Oxidizing, Reducing |
| Sample Capacity | Determined by Crucible Size |
| Vendor Type | Authorized Distributor |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | JRWS |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Transient Hot Wire Method |
| Dimensions (L×W×H) | 190 × 95 × 140 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.01–10 W/m·K |
| Repeatability | ±2% |
| Temperature Control Range | 5–85 °C |
| Temperature Measurement Error | ≤±0.1 °C |
| Resolution | 0.01 °C |
| Thermal Diffusivity Stability Requirement | ≤±1 °C (entire test), ≤±0.5 °C (steady-state phase) |
| Specific Heat Capacity Range | 0.5–5.0 kJ/(kg·K) |
| Specimen Geometry | Ø200 mm × 400 mm cylinder with central Ø40 mm through-hole |
| Water Bath Temp Range | 10–80 °C |
| Heating Rate | 0.5–1.0 °C/min |
| Strain Measurement | Resistance strain gauge, 250 mm gauge length, resolution 0.1 με |
| Power Supply | AC 220 V ±10%, 50–60 Hz, ≤6 kW |
| Brand | JuBen |
|---|---|
| Origin | Shanghai, China |
| Model | JB-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 500 × 800 × 1200 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–300 W/(m·K) |
| Repeatability | ±3% |
| Brand | JUZEN |
|---|---|
| Model | JB-STA-200 |
| Origin | Shanghai, China |
| Type | Benchtop Simultaneous Thermogravimetric Analyzer with Differential Scanning Calorimetry |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 0.1–100 °C/min |
| Mass Resolution | 0.1 µg |
| DSC Sensitivity | <0.1 µW |
| Atmosphere Control | Dual-gas (N₂/air) with mass flow controller |
| Sample Capacity | Up to 200 mg |
| Compliance | ASTM E1131, ISO 11358, ISO 17516, USP <41>, GLP-ready data logging |
| Brand | JWGB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 600 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | −150 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–200 °C/min |
| Temperature Precision | ±0.1 °C |
| Brand | Karg |
|---|---|
| Origin | Germany |
| Model | HST 53-3 |
| Temperature Control Range | Room Temperature +5°C to 300°C |
| Internal Chamber Volume | 53 L |
| Internal Dimensions (W×H×D) | 400 × 400 × 330 mm |
| External Dimensions (W×H×D) | 635 × 620 × 575 mm |
| Timer Range | 0–99 hours |
| Power Supply | 220 V AC ±10% |
| Compliance | DIN EN 60811-2-1 |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | Kofler HB |
| Type | Hot-block melting point apparatus |
| Principle | Kofler hot-plate method (linear temperature gradient) |
| Application | Rapid qualitative and semi-quantitative melting point determination of organic crystalline solids |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | D&S AERD |
| Pricing | Upon Request |
| Measurement Principle | Thermopile-based differential temperature method per ASTM C1371 |
| Wavelength Range | 3–30 µm |
| Emissivity Range | 0.01–1.00 |
| Repeatability | ±0.01 emittance units |
| Response Time | ~10 s |
| Display Accuracy | ±0.3% of reading |
| Operating Temperature | −10 to +40 °C |
| Dimensions (H×W×D) | 51 × 80 × 152 mm |
| Weight | ~370 g |
| Detector Output | ~2.5 mV |
| Power Supply | DC 9 V (host), AC 100–240 V (charger) |