| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Resolution | 1 m³/h |
| Flow Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Temperature Measurement Range | 0–50 °C |
| Temperature Accuracy | ±0.5 °C |
| Display | Dual-parameter (airflow + temperature), battery level, unit toggle (m³/h / CFM, °C), on-device data processing |
| Communication | Bluetooth 4.0, USB output |
| Data Storage | Up to 6,000 records (internal memory) |
| Power | 4 × AA alkaline batteries or AC adapter |
| Battery Life | Approx. 8 hours continuous operation |
| Dimensions (Hood) | 355 × 355 × 450 mm (W×H×D) |
| Hood Aperture | 355 × 355 mm |
| Display Module | 160 × 80 × 45 mm |
| Weight | 1.5 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Instrument Type | Pitot-Static Air Flow Hood |
| Flow Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Temperature Range | 0–50 °C |
| Temp. Accuracy | ±0.5 °C |
| Display | 160×80 mm full-color LCD |
| Data Storage | 6,000 records (internal) |
| Connectivity | Bluetooth 4.0, USB output |
| Power | 4 × AA batteries or AC adapter |
| Operating Time | ~8 hours |
| Dimensions (hood) | 355 × 355 × 450 mm (W×H×D) |
| Weight | 1.5 kg |
| Probe Material | Fiberglass support rod |
| Compliance | Designed for HVAC commissioning per ASHRAE 111, ISO 16813, and EN 12599 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6822 / 6824 |
| Instrument Type | Vane Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Operating Temperature | −20 to +100 °C |
| Operating Humidity | 5.0–95.0 %RH |
| Temperature Accuracy | ±1.0 °C |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Air Volume Range | 0–9,999 CFM |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe (e.g., 0.05–30 m/s for standard hot-wire probe) |
| Accuracy | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Interface | Standardized 8-pin detachable connector supporting eight interchangeable probe types |
| Built-in Calculations | Volumetric airflow (m³/h, CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| On-device Statistics | Real-time min/max/average of velocity, temperature, humidity, and pressure |
| Data Hold & Recall | Instant freeze-display and historical retrieval |
| Accessories Included | 2 m probe cable ×1, carrying case ×1, operation manual ×1 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Probe Model (e.g., 0.05–30 m/s for standard hot-wire probes) |
| Accuracy | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Probe Compatibility | 8 interchangeable probe types |
| Data Storage Capacity | Up to 20,000 records |
| Built-in Functions | Real-time hold, statistical calculation (mean, max, min), cross-sectional area input for volumetric flow derivation |
| Included Accessories | 2 m probe cable × 1, carrying case × 1, operation manual |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA12 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0–50.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10–50.0 m/s) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 2.0–98.0 %RH |
| Analog Output Options | 0–5 V DC or 4–20 mA |
| Channel Count | 4 independent measurement channels |
| Probe Compatibility | 10 interchangeable thermal anemometer probes (e.g., KA01, KA02, KA03 series) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA12 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Accuracy | ±3% of reading |
| Measurement Range | Probe-dependent (e.g., 0.05–30 m/s typical for standard hot-wire probes) |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–100% RH |
| Analog Output | 0–5 V or 4–20 mA |
| Communication Interface | RS-232C |
| Power Supply | AC 220 V |
| Dimensions | 200 × 260 × 70 mm |
| Weight | 2.6 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | KA12 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10–50 m/s) |
| Measurement Range | 0–50.0 m/s |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 2.0–98.0 %RH |
| Channel Count | 4 simultaneous channels |
| Probe Compatibility | 10 interchangeable probe types |
| Analog Output Options | 0–5 V DC or 4–20 mA |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | KA12 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Probe-Dependent (e.g., 0–30 m/s typical for standard hot-wire probes) |
| Accuracy | ±3% of reading |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–100% RH |
| Communication Interface | RS-232C |
| Analog Output | 0–5 V DC or 4–20 mA |
| Power Supply | AC 220 V |
| Dimensions | 200 × 260 × 70 mm |
| Weight | 2.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Probe-Dependent (e.g., 0–30 m/s typical for standard hot-wire probes) |
| Accuracy | ±3% of reading |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–100 %RH |
| Analog Output | 0–5 V DC or 4–20 mA |
| Communication Interface | RS-232C |
| Power Supply | AC 220 V |
| Dimensions | 200 × 260 × 70 mm |
| Weight | 2.6 kg |
| Channel Count | 4 simultaneous channels |
| Probe Compatibility | 10 interchangeable thermal anemometer probes |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | KA12 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Probe-Dependent (m/s) |
| Accuracy | ±3% of reading |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–100% RH |
| Communication Interface | RS-232C |
| Analog Output | 0–5 V DC or 4–20 mA |
| Power Supply | AC 220 V |
| Dimensions | 200 × 260 × 70 mm |
| Weight | 2.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | KA12 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Probe-Dependent (m/s) |
| Accuracy | ±3% of reading |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–100% RH |
| Communication Interface | RS-232C |
| Analog Output | 0–5 V DC or 4–20 mA |
| Power Supply | AC 220 V |
| Dimensions | 200 × 260 × 70 mm |
| Weight | 2.6 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KA12 |
| Instrument Type | Thermal Anemometer |
| Wind Speed Range | 0–50.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10–50 m/s) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 2.0–98.0 %RH |
| Power Supply | AC 220 V |
| Dimensions | 200 × 260 × 70 mm |
| Weight | 2.6 kg |
| Communication Interface | RS-232C |
| Analog Output | 0–5 V or 4–20 mA |
| EMI Filtering | Integrated |
| Display | LCD with manual channel selection |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Probe-Dependent (e.g., 0.05–30 m/s typical for standard hot-wire probes) |
| Accuracy | ±3% of reading |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–100% RH |
| Analog Output | 0–5 V DC or 4–20 mA |
| Communication Interface | RS-232C |
| Power Supply | AC 220 V |
| Dimensions | 200 × 260 × 70 mm |
| Weight | 2.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA23 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–50.0 m/s |
| Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±2% FS |
| Temperature Range | −20–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C (−20–0 °C and 60–100 °C: ±0.5 °C) |
| Pressure Range | 0.00–±5.00 kPa |
| Pressure Resolution | 0.01 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Operating Humidity | 2.0–98.0% RH |
| Dimensions (Main Unit) | 157 × 42 × 80 mm (W×H×D) |
| Probe Handle Diameter | Max Φ15 mm, Length Adjustable: 140–235 mm |
| Power | 4 × AA Alkaline Batteries or 5 V / 2 A AC Adapter |
| Weight | Approx. 450 g (incl. batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA23 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–50.0 m/s |
| Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±2% FS |
| Operating Temperature | −20–100°C |
| Operating Humidity | 2.0–98.0% RH |
| Temperature Range & Accuracy | −20–100°C (±0.3°C in −20–0°C and 60–100°C: ±0.5°C) |
| Pressure Range & Accuracy | 0.00–±5.00 kPa (±0.1 kPa) |
| Display | Dual digital/analog view with 3-level backlight |
| Data Logging | Max/Min/Avg velocity, pass/fail threshold mode |
| Probe | Interchangeable, telescopic (Ø15 mm max, 140–235 mm extendable) |
| Power | 4× AA alkaline batteries or 5 V/2 A AC adapter |
| Dimensions (main unit) | 157(W)×42(H)×80(D) mm |
| case | 167(W)×66(H)×88(D) mm |
| Weight | ~450 g (with batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA23 / KA33 |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–50.0 m/s |
| Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±2% FS |
| Temperature Range | −20–100 °C |
| Temperature Accuracy | ±0.3 °C (−20–0 °C, 60–100 °C: ±0.5 °C) |
| Pressure Range | 0.00–±5.00 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Humidity Range | 2.0–98.0% RH |
| Dimensions (Main Unit) | 157 × 42 × 80 mm (W × H × D) |
| Weight | ~450 g (incl. batteries) |
| Power | 4 × AA alkaline batteries or 5 V / 2 A AC adapter |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA23/KA33 |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–50.0 m/s |
| Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±2% FS |
| Operating Temperature | −20 to +100 °C |
| Operating Humidity | 2.0–98.0% RH |
| Display | 3.5-inch true-color LCD with dual digital/analog visualization |
| Power Supply | 6 V DC (4 × AA batteries) |
| Battery Life | Extended by 25% vs. predecessor (KA22/KA31) |
| Probe Interchangeability | Fully compatible hot-wire probes with mechanical extension and bendable shaft |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–50.0 m/s |
| Velocity Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±2% FS (full scale) for velocity |
| Temperature Range | −20 to +100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C (−20 to 0 °C and 60 to 100 °C: ±0.5 °C) |
| Differential Pressure Range | 0.00 to ±5.00 kPa |
| Pressure Resolution | 0.01 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Operating Humidity | 2.0–98.0% RH |
| Dimensions (main unit) | 157 × 42 × 80 mm (W×H×D) |
| Weight | ~450 g (incl. batteries) |
| Power | 4 × AA alkaline batteries or 5 V / 2 A AC adapter |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20 to 70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at wind speed > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Air Volume Calculation | Enabled (rectangular & circular ducts, dimensions 0.1–255.0 cm) |
| Data Hold, Min/Max/Avg Statistics, Adjustable Time Constant (1/5/10/20 s), Auto Power-Off (3/5/10 min), Backlit LCD (3-level), Power | 4 × AA alkaline batteries (~15 h operation), Unit Weight: ~220 g (without batteries), Probe Dimensions: Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm, Cable Length: 2000 mm, Body Dimensions: 200 × 85 × 40 mm |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Temperature Range (Air) | −20.0 to +70.0 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Air Volume Calculation | Yes (rectangular & circular ducts, 0.1–255.0 cm dimensions) |
| Response Time (Velocity) | ~1 s (90%, at 1 m/s) |
| Response Time (Temperature) | ~30 s (90%, at 1 m/s) |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Data Hold Function | Yes |
| Statistical Functions | Min / Avg / Max |
| Auto Power-Off | 3 / 5 / 10 min selectable |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | Approx. 15 h (1 m/s, 20 °C) |
| Operating Environment (Body) | 5–40 °C |
| (Probe) | −20–70 °C |
| Storage Temperature | −20–60 °C |
| Weight | ~220 g (body only, no batteries) |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & flexible) |
| Cable Length | 2000 mm |
| Housing Material | Impact-resistant ABS |
| Compliance | CE-marked |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20 to 70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at wind speed > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Air Volume Calculation | Yes (1 m³/h minimum resolution) |
| Data Hold Function | Yes |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Statistical Functions | Min / Avg / Max |
| Auto Power-Off | 3 / 5 / 10 min selectable |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | Approx. 15 h (1 m/s, 20 °C, alkaline) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle), 294–1060 mm extendable & bendable |
| Cable Length | 2000 mm |
| Body Operating Temp. | 5–40 °C |
| Probe Operating Temp. | −20–70 °C |
| Storage Temp. | −20–60 °C |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Main unit, hot-wire probe, carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Resolution | 0.01 m/s |
| Velocity Accuracy | ±(3% of reading + 0.03 m/s) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Velocity) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Air Flow Calculation | Enabled for rectangular & circular ducts (cross-sectional dimensions input required) |
| Power | 4 × AA alkaline batteries (~15 h operation at 1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor tip) / Ø14 mm (handle), 294–1060 mm extendable & bendable |
| Cable Length | 2000 mm |
| Operating Environment (Body) | 5–40 °C |
| Storage Temperature | −20 to +60 °C |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Main unit, telescoping/bendable probe, protective carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20 to 70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Air Volume Resolution | 1 m³/h |
| Response Time (Velocity) | ~1 s (90%, at 1 m/s) |
| Response Time (Temperature) | ~30 s (90%, at 1 m/s) |
| Probe Dimensions | Ø6 mm (sensor), Ø14 mm × 294–1060 mm (telescoping handle) |
| Body Dimensions | 200 × 85 × 40 mm |
| Weight | ~220 g (without batteries) |
| Power | 4 × AA alkaline batteries |
| Battery Life | ~15 h (at 1 m/s, 20 °C) |
| Auto-Off Options | 3/5/10 min |
| Time Constant Settings | 1/5/10/20 s |
| Statistical Functions | Min/Avg/Max |
| Pipe Shape Support | Rectangular & Circular |
| Pipe Size Input Range | 0.1–255.0 cm |
| Display | 3-level backlight LCD |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20–70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Power | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Diameter | Φ6 mm (sensor), Φ14 mm (handle) |
| Probe Length | 294–1060 mm (telescoping & flexible) |
| Cable Length | 2000 mm |
| Weight | ~220 g (without batteries) |
| Included Accessories | Main unit, telescoping probe, protective carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20–70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90%, at 1 m/s) |
| Response Time (Temperature) | ~30 s (90%, at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Air Flow Display | Up to 1 m³/h |
| Data Hold Function | Yes |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Statistical Functions | Min / Avg / Max |
| Auto Power-Off | 3 / 5 / 10 min |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & flexible) |
| Cable Length | 2000 mm |
| Body Operating Temp. | 5–40 °C |
| Probe Operating Temp. | −20–70 °C |
| Storage Temp. | −20–60 °C |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Instrument body, telescoping/flexible probe, protective carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Resolution | 0.01 m/s |
| Velocity Accuracy | ±(3% of reading + 0.03 m/s) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Velocity) | ~1 s (90%, at 1 m/s) |
| Response Time (Temperature) | ~30 s (90%, at 1 m/s) |
| Air Volume Range | ≥1 m³/h |
| Pipe Shape Compatibility | Rectangular & Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Data Hold Function | Yes |
| Auto Power-Off Options | 3/5/10 min |
| Time Constant Settings | 1/5/10/20 s |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & bendable) |
| Cable Length | 2000 mm |
| Operating Environment (Body) | 5–40 °C |
| Storage Temperature | −20 to +60 °C |
| Weight | ~220 g (without batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20 to 70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Pipe Dimension Input Range | 0.1–255.0 cm |
| Air Volume Calculation | Yes (m³/h) |
| Data Hold Function | Yes |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Statistical Functions | Min / Avg / Max |
| Auto Power-Off | 3 / 5 / 10 min selectable |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & bendable) |
| Cable Length | 2000 mm |
| Body Operating Temp. | 5–40 °C |
| Probe Operating Temp. | −20–70 °C |
| Storage Temp. | −20–60 °C |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Main unit, telescoping probe, protective carrying case, quick-start guide, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Resolution | 0.01 m/s |
| Velocity Accuracy | ±(3% of reading + 0.03 m/s) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Velocity) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Air Volume Calculation | Yes (rectangular & circular ducts, 0.1–255.0 cm dimensions) |
| Data Hold, Min/Max/Avg Statistics, Adjustable Time Constant (1/5/10/20 s), Auto Power-Off (3/5/10 min), Backlit LCD (3-level), Battery Life | ~15 h (4 × AA alkaline), Weight: ~220 g (body only), Dimensions (body): 200 × 85 × 40 mm, Probe: Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & flexible), Cable Length: 2000 mm, Operating Environment (body): 5–40 °C, Storage Temp: −20–60 °C |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Resolution | 0.01 m/s |
| Temperature Range | −20 to 70 °C (probe), 5 to 40 °C (body) |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (90%) | ~1 s (velocity), ~30 s (temperature) |
| Air Volume Calculation | Yes (rectangular & circular ducts, 0.1–255.0 cm dimensions) |
| Data Logging Functions | Min/Max/Avg, Hold, Auto Power-Off (3/5/10 min), Adjustable Time Constant (1/5/10/20 s) |
| Display | 3-level backlight LCD |
| Power | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Dimensions (Body) | 200 × 85 × 40 mm |
| Probe | Ø6 mm (sensor) / Ø14 mm (handle), 294–1060 mm telescopic & bendable |
| Cable Length | 2000 mm |
| Weight | ~220 g (without batteries) |
| Compliance | Designed for ISO 14644-3, ISO 14644-4, EU GMP Annex 1, and USP <1116> environmental monitoring workflows |