Empowering Scientific Discovery

Beijing Oulan Guangshi Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJenLab
OriginGermany
ModelMPTflex CARS
Detection PrincipleMultiphoton Excitation + Coherent Anti-Stokes Raman Scattering (CARS)
Spatial ResolutionSubcellular (~0.5 µm lateral, ~1.5 µm axial)
Laser WavelengthsTunable near-infrared (700–1100 nm for excitation
Imaging DepthUp to 200 µm in human skin *in vivo*
Real-time Chemical ContrastLabel-free molecular vibrational fingerprinting (e.g., lipids, proteins, melanin, water, collagen)
Regulatory ComplianceCE-marked for clinical research use
compliant with IEC 60825-12014 (laser safety)
Software PlatformMPTconsole v5.x with FDA 21 CFR Part 11–ready audit trail and GLP-compliant data archiving
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJenLab
OriginGermany
Model2PM™-Cryo
Laser SourceTi:Sapphire femtosecond oscillator (710–920 nm, 80 MHz, 100–200 fs, <1.3 W)
Temperature Range77 K to 873 K (−196 °C to +600 °C)
Cooling/Heating Rate0.01–150 K/min
Spatial Resolution<0.5 µm (lateral), <2 µm (axial)
Temporal Resolution200 ps (TCSPC, up to 256 time channels)
FOV250 µm × 250 µm (lateral), ≤2 mm depth
ObjectiveStandard 40×, NA 1.3 (optional objectives available)
SoftwareJenLab Control & JenLab Image
ComplianceCE-marked
Power Supply115 VAC / 60 Hz or 230 VAC / 50 Hz
Dimensions (excl. laser)700 × 520 × 800 mm³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJenLab
OriginGermany
Model2PM™
TypeImported Scientific Instrument
Distribution ChannelAuthorized Distributor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJenLab
OriginGermany
Model2P Microendoscope
Application DomainIn Vivo Intratissue Imaging, Clinical Dermatology, Tissue Engineering, Fluorescent Protein Detection
Compatible PlatformsDermaInspect® and MPTflex Multiphoton Workstations
Optical Sectioning CapabilityDepth-Resolved In Situ Imaging of Human Skin and Small Animal Tissues
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJenLab
OriginGermany
ModelTauMap®
TypeFLIM/FCS/FRET Multimodal Microscopy System
Application DomainBiomedical Research, Pharmaceutical Development, Live-Cell Dynamics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJenLab
OriginGermany
Modelfemt-O-cut
Laser Wavelength710–990 nm
Pulse Duration< 100 fs
Repetition Rate80 MHz
Avg. Output Power1.5 W
Numerical Aperture (NA)1.3
Lateral Resolution< 1 µm
Axial Resolution< 2 µm
3D Processing DepthUp to 100 µm
Minimum Feature Size< 70 nm (FWHM)
Scanning Range350 × 350 µm (XY), 200 µm (Z)
Piezo Z-Stage Precision40 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJenLab
OriginGermany
ModelfemtOgene®
Laser Pulse Width< 20 fs (typ. < 150 fs)
Repetition Rate85 MHz
Average Power200–400 mW
Wavelength800 ± 10 nm
Objective40×, NA 1.3
Scan Range350 × 350 µm (H), 200 µm (V)
Stage Travel120 × 102 mm
Dispersion CompensationIntegrated high-order module
Operating Temp.15–35 °C
RH5–80%
Power SupplyAC 230 V, 50 Hz
System FootprintBase 490 × 280 × 480 mm³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJenLab
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMPTcompact
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMCL Think Nano
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNano-Cyte®
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJenLab
OriginGermany
ModelMPTflex
Laser SourceNear-infrared femtosecond laser
Spatial ResolutionSubcellular (≤0.5 µm lateral, ≤1.5 µm axial)
Imaging DepthUp to 200 µm in human skin *in vivo*
Detection ModeFluorescence & Second Harmonic Generation (SHG)
Clinical ComplianceCE-marked as Class IIa medical device per MDR 2017/745
Software PlatformMPTconnect v5.x with FDA 21 CFR Part 11–ready audit trail and GLP/GMP-compatible data archiving
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0