BrandAII
OriginUSA
ModelGPR-1200
PrincipleGalvanic Electrochemical Sensor
Measurement Range0–10 / 0–100 / 0–1000 ppm O₂ (auto/manual switchable)
Accuracy±1% of full scale (at 25°C, 1 atm)
Resolution0.1% of minimum selected range
LinearityR² > 0.995
Response Time (t₉₀)10 s
Recovery Time60 min (from air to 10 ppm)
Sensor Lifetime>24 months (at 1000 ppm O₂)
Enclosure RatingNEMA 4X, IP66
Explosion ProtectionClass I, Division 1, Groups A, B, C, D (intrinsically safe)
Operating Temperature5–45°C with built-in temperature compensation
Sample Flow Rate0.5–5 SCFH (recommended: 2 SCFH ≈ 1 L/min)
Inlet Pressure5–100 psig (vacuum operation requires optional vacuum pump)
DisplayBacklit LCD showing real-time O₂ concentration, sample pressure & temperature
PowerRechargeable battery
Output0–1 V analog output
CertificationsCE, ISO 9001
Optional AccessoriesIntegrated vacuum pump, acid-gas sensor (for CO₂/H₂S-containing streams), particulate filter unit, custom calibration gases
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-18
Measurement PrincipleElectrochemical Sensor
Range0–10 / 100 / 1000 ppm, 0–1% / 25% O₂
Resolution0.1% of full scale
Accuracy±1% of full scale (at 25°C, 1 atm)
LinearityR² > 0.995
T₉₀ Response Time≤10 s
Recovery Time≤60 min (from air to 10 ppm)
Sensor Lifetime24 months
CertificationsCE, FM Class I Division 1 Groups B, C, D, CSA, ISO 9001
Display3½-digit LED
Analog Outputs0–1 V DC and 4–20 mA
Power Supply220 V AC @ 50 Hz
Alarm OutputsTwo user-adjustable relay outputs + fault alarm
Sample Flow Rate1–5 SCFH (recommended: 2 SCFH ≈ 1 L/min)
Operating Temperature5–45°C with automatic temperature compensation
Operating Pressure5–100 psig
EnclosureAnodized aluminum, NEMA 4/7 rated
Dimensions12" × 11.5" × 10.5" (305 × 292 × 267 mm)
Weight40 lb (18.1 kg)
Sample CompatibilityH₂, hydrocarbons, process gases, acid gases containing CO₂ (specify at order)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1500
Measurement PrincipleElectrochemical Fuel Cell
Range0–10 / 100 / 1000 ppm, 0–1% / 25% FS
Accuracy<1% FS (at ambient temperature and pressure)
Sensor Life24 months (GPR-12-333 fuel cell)
Linearity>0.995
Response Time10 s (T₉₀)
Sensitivity0.5% FS
Pressure Range5–30 psig (inlet), atmospheric (outlet)
Flow Rate0.5–5 SCFH (recommended: 2 SCFH)
Temperature Range5–45°C (GPR sensor)
CompensationAutomatic temperature and barometric pressure compensation
Output Signal4–20 mA
Display Resolution0.01 ppm
Enclosure RatingNEMA 4X (aluminum-coated)
Ingress ProtectionIP66
Electrical InterfaceWaterproof membrane keypad
Gas Connection1/8" Swagelok® compression fitting
CertificationsCE, ISO 9001
Hazardous Area OptionsIntrinsically safe configuration available with approved safety barrier for Class 1, Division 1, Groups A–D (per UL 913 & CSA C22.2 No. 157)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-2000
Measurement PrincipleElectrochemical Sensor
Range0–1%, 0–5%, 0–10%, 0–25% O₂ (Auto/Manual Switching)
Resolution0.01% O₂
Accuracy±1% of full scale (at 25°C, 1 atm)
LinearityR² > 0.995
Response Time (T₉₀)<10 s
Sensor Lifetime36 months (standard), 24 months (acid-resistant)
EnclosureAnodized Aluminum, NEMA 4X Rated
Dimensions4" × 9" × 3" (10.2 × 22.9 × 7.6 cm)
Weight7 lbs (3.2 kg)
DisplayBacklit LCD with Real-Time Temperature Readout
Output0–1 V Analog
PowerRechargeable Battery (60-day operational life per charge)
CertificationsCE, ISO 9001
Operating Temperature5–45°C with Built-in Temperature Compensation
Pressure Range5–30 psig (vacuum operation optional with integrated pump)
Flow Rate0.5–5 SCFH (recommended: 2 SCFH ≈ 1 L/min)
Gas CompatibilityH₂, He, hydrocarbons, inert gases, acid gases (CO₂, H₂S—requires acid-resistant sensor option)
CalibrationRecommended with 80% FS certified gas
Inlet/Outlet1/8" Swagelok® Compression Fittings
Standard AccessoriesRugged Carrying Case, Charger & Battery, 2 m Sample Tubing, English/Chinese User Manual
Optional AccessoriesIntegrated Flow Control Valve & Rotameter, Internal Vacuum Pump, Food Packaging Configuration, Intrinsically Safe Design (Class I, Div 1, Groups A/B/C/D), Acid-Resistant Sensor Kit