- All
- Favorite
- Popular
- Most rated
| Measurement Range | 0.02–1200 µm |
|---|---|
| Accuracy Error | < ±1% (D50, NIST-traceable standard materials) |
| Repeatability | < ±1% (D50, same sample, 3 consecutive runs) |
| Laser Source | He-Ne, 632.8 nm, >25,000 h lifetime |
| Detector Array | Non-uniform 3D crossed fan-shaped matrix, max detection angle 135° |
| Dispersion System | Integrated 400 mL wet cell with 100 W ultrasonic probe, automatic degassing, circulation, rinsing & drainage |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions | 1000 × 330 × 320 mm |
| Weight | 39 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Rise-2012 |
| Price Range | USD 0–14,500 |
| Dispersion Method | Dry dispersion only |
| Measurement Range | 0.1–600 µm |
| Repeatability | < ±1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | ≤10 seconds per run |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | RISE-2206 |
| Pricing | Upon Request |
| Measurement Range | 0.05–800 µm |
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, 3 consecutive runs) |
| Laser Source | He-Ne, 632.8 nm, >25,000 h lifetime |
| Detector Array | Non-uniform cross-3D扇-shaped matrix, max detection angle 105° |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 1000 × 330 × 320 mm |
| Weight | 39 kg |
| Dispersion System | Integrated 400 mL wet dispersion cell with 100 W ultrasonic probe, automatic degassing, circulation, rinsing and drainage |
| Measurement Range | 0.1–1200 µm |
|---|---|
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, repeated measurements) |
| Laser Source | He-Ne, 632.8 nm, >25,000 h lifetime |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions | 950 × 330 × 300 mm |
| Weight | 40 kg |
| Detector Array | Non-uniform, cross-aligned 3D扇-shaped matrix, max detection angle 135° |
| Optical Design | Single-range convergent beam Fourier optics, alignment-free |
| Software | PADMAS v5.x (Particle Diameter Measure & Analysis System) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Rise-2008 |
| Pricing | Available Upon Request |
| Measurement Range | 0.02–1200 µm |
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, consecutive runs) |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 1000 × 330 × 320 mm |
| Weight | 38 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | RISE-2026 |
| Pricing | Upon Request |
| Measurement Range (Wet) | 0.05–800 µm |
| Measurement Range (Dry) | 0.1–800 µm |
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, repeated measurements) |
| Electrical Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 950 × 330 × 300 mm |
| Weight | 50 kg |
| Laser Source | He–Ne gas laser, λ = 632.8 nm, lifetime >25,000 h |
| Maximum Detection Angle | 105° |
| Detector Array | Non-uniform cross-three-dimensional扇-shaped matrix (translated as “non-uniform crossed 3D sectoral matrix”) |
| Optical Design | Single-range convergent optical path, Fourier lens-free alignment |
| Standard Grading | 130 size classes default (0.02–2000 µm), fully customizable from Class 1 to 130 |
| Software | PADMAS v5.x (Particle Diameter Measure & Analysis System) |
| Data Export | CSV, Excel (.xlsx), PDF, PNG/JPEG images |
| Compliance | Designed per Q/01RZ01–2004 enterprise standard |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Rise-2016 |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Dry dispersion only |
| Measurement Range | 0.1–800 µm |
| Repeatability | < ±1% RSD (NIST-traceable standard reference material, D₅₀) |
| Measurement Time | ≤10 seconds per analysis |
| Laser Source | He-Ne, 632.8 nm, >25,000 h lifetime |
| Detector Array | Non-uniform, cross-dimensional 3D扇-shaped matrix, max detection angle 105° |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 950 × 330 × 300 mm |
| Weight | 40 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Rise-2002 |
| Pricing | Available Upon Request |
| Measurement Range | 0.1–600 µm |
| Accuracy Error | < ±1% (D50, Certified Reference Materials per GB/T 19077) |
| Repeatability | < ±1% (D50, Certified Reference Materials) |
| Electrical Supply | AC 220 ±10 V, 50 Hz, 200 W |
| Dimensions (L×W×H) | 1000 × 330 × 320 mm |
| Weight | 38 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Rise-2006 |
| Pricing | Available Upon Request |
| Measurement Range | 0.05–800 µm |
| Accuracy Error | < ±1% (D50, certified reference materials per GB/T 19077–2016) |
| Repeatability | < ±1% (D50, same standard) |
| Electrical Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions | 1000 × 330 × 320 mm |
| Weight | 38 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | RISE-2028 |
| Pricing | Available Upon Request |
| Measurement Range (Wet) | 0.02–1200 µm |
| Measurement Range (Dry) | 0.1–1200 µm |
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, repeated measurements) |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 950 × 330 × 300 mm |
| Weight | 50 kg |
| Laser Source | He-Ne gas laser, λ = 632.8 nm, lifetime >25,000 h |
| Maximum Detection Angle | 135° |
| Detector Array | Non-uniform cross-three-dimensional扇-shaped matrix (translated as “non-uniform crossed 3D sectoral matrix”) |
| Default Size Classes | 130 channels (0.02–2000 µm), fully customizable from 1–130 channels |
| Data Output | Excel-compatible CSV, PDF, image (PNG/JPEG), printable reports with header/footer customization |
| Software | PADMAS v5.x (Particle Diameter Measure & Analysis System) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Rise-2022 |
| Pricing | Upon Request |
| Measurement Range | 0.1–600 µm |
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, repeated measurements) |
| Electrical Supply | AC 220 ±10 V, 50 Hz, 200 W |
| Dimensions (L×W×H) | 950 × 330 × 300 mm |
| Weight | 40 kg |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RISE 2202 |
| Pricing | Available Upon Request |
| Measurement Range | 0.1–600 µm |
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, consecutive runs) |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 1000 × 330 × 320 mm |
| Weight | 39 kg |
| Laser Source | He-Ne gas laser, λ = 632.8 nm, linewidth < 0.002 nm, lifetime > 25,000 h |
| Detector Array | Non-uniform, cross-dimensional 3D扇-shaped matrix (patent-pending geometry), max detection angle: 90° |
| Dispersion System | Integrated 400 mL wet dispersion cell with 100 W ultrasonic probe, programmable sonication time, adjustable stirrer speed & circulation pump flow rate |
| Software | PADMAS v5.2 (Particle Diameter Measure & Analysis System), compliant with GLP audit trail requirements, supports FDA 21 CFR Part 11 optional electronic signature module |
Show next