| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI-100E |
| Price | USD 12,000 (FOB Beijing) |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Detection Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Sampling Interval | 0.1 Hz (standard), 0.02 Hz (optional) |
| Vertical Travel | 0–50 mm (standard), up to 110 mm (optional) |
| Positioning Accuracy | 0.1 µm |
| Force Sensor | High-precision 0.1 mg electromagnetic balance (Mettler Toledo OEM) |
| Temperature Control Support | External thermostatic bath interface (−20 °C to +95 °C, optional) |
| Data Output | Real-time tension curve logging, CSV export, on-device LCD display + thermal printer (integrated) |
| Compliance | SY/T 5370–1999 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JK99D |
| Pricing | Upon Request |
| Measurement Range | 0–500 mN/m |
| Sensitivity | 0.05 mN/m |
| Accuracy | ±0.1 mN/m |
| Resolution | <0.05 mN/m |
| Methods | Du Noüy Ring & Wilhelmy Plate |
| Ring Method Cycle Time | 150–200 s |
| Plate Method Cycle Time | 1–5 s |
| Power Supply | AC 220 ±5 V, <150 W |
| Temperature Control Precision | ±0.1 °C (with optional thermostatic platform) |
| Humidity Range | 30–85% RH |
| Zeroing | Hardware & Software One-Touch Auto-Zero |
| Calibration | Integrated standard weight kit |
| Compliance | ASTM D971, ISO 6295, ISO 1409, USP <721>, GB/T 6541 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JC2000X |
| Pricing | Available Upon Request |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JC2000C |
| Pricing | Available Upon Request |
| Stage Platform | 100 × 100 mm |
| Motion Control | Manual or Motorized 3-Axis Translation Stage |
| Dispensing System | Manual or Automated Syringe Pump |
| Imaging | Digital CCD Camera (25 fps) |
| Tilt Capability | Adjustable CCD Mount |
| Optical Lens | Continuous Zoom Lens (0.7×–4.5×), Domestic or Imported |
| Optional Heating Stage | Ambient to 100 °C |
| Optional Sample Oscillation Stage | ±15° |
| Optional Accessories | Fiber Holder, Fabric Tension Frame, Plate Insertion Module, Pendant Drop Module |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JMP2000 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI-1700 |
| Price Range | USD 14,000 – 28,500 |
| Instrument Class | High-Temperature Vacuum Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±1° (θ/2 method), ±0.1° (automated circle fitting) |
| Sample Stage Dimensions | 100 × 100 mm |
| Image Magnification | 55–320 pixels/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Maximum Operating Temperature | 1600 °C (in inert atmosphere) |
| Vacuum Limit | ≤5×10⁻⁵ Pa (with turbo-molecular + backing pump configuration) |
| Heating Control | 40-segment programmable PID via B-type thermocouples (Pt/Rh) |
| Temperature Resolution | ±0.1 °C (<1000 °C), ±1 °C (≥1000 °C) |
| Cooling System | Closed-loop water chiller (5–35 °C, 10–20 L/min flow, 1.0–1.3 bar pressure, 1200 W cooling capacity) |
| Optical System | 300-mm working distance telecentric lens, 0.7–4.5× continuous zoom, industrial-grade low-light color CCD (1.3 MP) |
| Software Capabilities | Multi-method contact angle calculation (θ/2, tangent, circle/ellipse/curve fitting), time- and temperature-triggered image capture (min. interval: 0.1 s), left/right asymmetry analysis, automated averaging, GLP-compliant data logging with timestamped image–value pairing and Excel export |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JC2000DM |
| Price Range | USD 7,000–14,000 |
| Instrument Class | Video-Based Optical Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Fixed Sample Stage Dimensions | 100 × 80 mm |
| Optical Magnification | 0.7×–4.5× Continuous Zoom |
| Surface/Interfacial Tension Range | 0–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JML04C3 |
| Price Range | USD 7,000 – 14,000 |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Trough Material | PTFE (Full Fluoropolymer Construction) |
| Trough Dimensions | 300 mm × 200 mm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upstroke & Downstroke |
| Power Supply | AC 220 V ±10%, 50 Hz, 150 W Max |
| Operating Temp | Ambient (with optional external thermostatic bath interface) |
| RH Range | 30–85% |
| Compliance | ASTM D971, ISO 6295, ISO 1409, USP <721>, GLP-ready data audit trail capability |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | JC2000D |
| Pricing | Upon Request |
| Stage | Manual or Motorized 3-Axis Sample Stage |
| Dispenser | Manual Precision Syringe System (10 µL / 100 µL) |
| Camera | USB 2.0 Industrial CCD, 700 TV Lines, 25 fps |
| Optical Zoom | 0.7×–4.5× Continuous Zoom Lens (with Post-Zoom Magnification |
| Effective Pixel Resolution | 50–318 px/mm) |
| Light Source | Adjustable Monochromatic LED Cold Light |
| Tilt Platform | ±15° Manual Sample Tilting Stage (Optional) |
| Rotation Platforms | 360° Vertical & Horizontal Rotational Stages (Optional) |
| Heating Stage | Ambient to 100 °C (Optional) |
| Accessories | Fiber Holder, Fabric Stretch Frame, Insertion Plate, Sessile Drop Arrest Device (All Optional) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JJ2000B |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Instrument Type | Benchtop Laboratory System |
| Measurement Principle | Optical Imaging (Video-Based Drop Shape Analysis) |
| Contact Angle Range | 0°–180° |
| Contact Angle Resolution | ±0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface Tension Resolution | 0.01 mN/m |
| Optical Magnification | 7× (motorized, software-controlled) |
| Field of View (FOV) | 3.2–23 mm |
| High-Speed Camera | 311 fps (standard), optional full-frame ultra-high-speed up to 20,000 fps |
| Image Resolution | 780 × 580 pixels (standard) |
| Sample Stage Dimensions (max. accommodated) | 320 mm (W) × ∞ (D) × 275 mm (H) |
| Stage Mobility | Motorized X/Y/Z translation (X/Y: ±100 mm |
| Z | ±38 mm) |
| Dispensing Systems | Dual automated syringe modules (0.01 µL minimum step), manual dispensing unit, auto-refill & auto-cleaning module, dedicated 50 nL precision dosing system |
| Data Throughput | 800 MB/s |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Rise-1010 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JML04C1 |
| Price Range | USD 14,000 – 28,500 |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate (Wilhelmy-Type) |
| Trough Material | PTFE (Fully Fluorinated) |
| Trough Dimensions | 200 mm × 80 mm |
| Compression Ratio | Up to 90% |
| Barrier Type | Leakproof Movable Barrier |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upward & Downward |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 150 W |
| Operating Temperature | Ambient (with optional external thermostatic bath support) |
| Relative Humidity | 30–85% RH |
| Software Interface | Windows-based GUI with real-time A–π and A–γ curve acquisition, exportable ASCII/CSV, post-processing capability |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | RISE |
|---|---|
| Origin | Beijing, China |
| Model | Rise-1020 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Low-Temperature Nitrogen Physisorption) |
| Analysis Stations | 2 |
| Degassing Stations | 3 |
| Specific Surface Area Range | 0.0005 m²/g to no upper limit |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–133 kPa |
| P/P₀ Range | 1×10⁻⁶–0.998 |
| Vacuum Level | ≤1.0×10⁻⁴ Torr |
| Temperature Control | Liquid Nitrogen Bath (77 K), PT-100 Sensor (±0.1 °C) |
| Pressure Sensors | 4× Imported Absolute Transducers (0–133 kPa, ±0.1% FS) |
| AD Resolution | 22-bit |
| Theoretical Models | BET, Langmuir, BJH, t-plot, D-A, H-K, SF, MP, NLDFT, GCMC |
| Repeatability | R² ≥ 0.99 |
| Degassing Temp | Up to 400 °C |
| Sample Tube Material | Stainless Steel |
| Dewar | 2 L Metal Dewar (Cryogenic Stability) |
| Software | ISO 9277 / ISO 15901 / GB/T 19587 Compliant Data Acquisition & Reporting Suite |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Rise-1030 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JJ2000B2 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DSA100 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | ±0.01° |
| Contact Angle Accuracy | 0.1° |
| Sample Stage Dimensions | 300 × 150 mm (standard), extendable to 500 × 48 mm |
| Optical Magnification | 0.7× (adjustable via zoom lens |
| FOV diagonal | 1.6–11 mm) |
| Surface/Interfacial Tension Measurement Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| High-Speed Camera Options | 60 fps (standard), up to 1000 fps (optional), customizable to 10,000+ fps |
| Temperature Control Range (Peltier) | –30 to +160 °C |
| Extended Thermal Stage (TC21) | –60 to +400 °C |
| Humidity Control Chamber | 5–95% RH |
| Automated Sample Handling | Up to 8 positions |
| Software Analysis Methods | Sessile Drop, Tilting Plate, Pendant Drop, Oscillating Drop, Single-Fiber Mode |
| Surface Energy Calculation Models | Owens-Wendt-Rabel, van Oss-Chaudhury-Good, Fowkes, Extended Fowkes, Wu, Zisman, Neumann |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JK99BM |
| Price Range | USD 1,400–7,000 |
| Measurement Range | 0–500 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | Ambient to 100 °C |
| Temperature Display Accuracy | ±0.1 °C |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Rise-1001 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | K100C |
| Price Range | USD 27,000–68,000 (est.) |
| Measurement Range | 1–2000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | −10 to +130 °C |
| Temperature Display Precision | ±0.1 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JF99A |
| Pricing | Upon Request |
| Measurement Principle | Washburn Capillary Rise Method |
| Pressure Range | 0–330 mbar |
| Pressure Resolution | 0.16 mbar |
| Operating Temperature | Ambient |
| Quartz Tube Dimensions | OD 10 mm |
| Instrument Dimensions | 295 × 240 × 260 mm |
| Power Supply | 220 V AC, 20 W |
| Optional Accessory | JYF08 Automated Powder Packing Station (programmable tapping cycles, real-time counter, uniform mechanical compaction) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SCI-1100 |
| Price Range | USD 14,000–28,000 |
| Instrument Class | High-Temperature Vacuum Contact Angle Measurement System |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±1° (θ/2 method), ±0.1° (Circle Fitting Method) |
| Sample Stage Dimensions | Ø14 mm × 10 mm |
| Optical Magnification | 0.7–4.5× |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | JC2000Y |
| Pricing | Available Upon Request |
| Sample Stage | 100 × 70 mm manual XYZ platform with concentric stepped design for optical lenses |
| Camera | USB 2.0 industrial CCD, 700 TV lines, 25 fps |
| Optical Zoom | 0.7×–4.5× continuous zoom lens (with auxiliary magnification optics) |
| Image Resolution | 50–318 pixels/mm |
| Light Source | Adjustable monochromatic LED cold light |
| Temperature Control | Optional ambient-to-100 °C heated stage |
| Tilt Capability | Optional ±15° sample oscillation stage |
| Rotation | Optional 360° vertical/horizontal rotation stages |
| Software | Automated contact angle analysis (advancing/receding/rolling angles), surface energy calculation (Owens–Wendt two-liquid method), sessile drop, pendant drop, and curved-surface correction |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | JB04 |
| Price Range | USD 14,000 – 28,000 |
| Light Source | 532 nm Green Laser (20 mW or 50 mW) |
| Laser Intensity Control | Continuous 1–100% Adjustment |
| Objective Lens | Nikon MS-01 Continuous Zoom, Working Distance 90 mm, Magnification Equivalent to 700–110 px/mm |
| Spatial Resolution | 2 µm |
| Incident Angle Range | 45°–60° |
| Polarization System | High-Extinction-Ratio Glan-Taylor or Wollaston Prism Polarizer |
| Imaging Sensor | Scientific-Grade CCD with Software-Controlled Electronic Shutter |
| Frame Acquisition | CG400 High-Speed Image Capture Card |
| Operating System | Windows 2000/XP-Compatible Native GUI Application |
Show next