Beijing Shangdetong Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelInLab-2100
Price RangeUSD 1,400 – 7,000
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at ~2960 cm⁻¹, ~2930 cm⁻¹, ~2850 cm⁻¹)
Measurement Range0.15 mg/L to 100 mg/L (using 5 cm quartz cuvette)
Detection Limit<0.12 mg/L (CCl₄ extract, direct measurement with 5 cm quartz cuvette)
<0.001 mg/L (water sample, 1001 extraction ratio, 5 cm quartz cuvette)
Accuracy±0.5 mg/L (C < 10 mg/L)
Resolution0.1 ppm
Measurement Frequency10 measurements/min
Wavenumber Range3400 cm⁻¹ – 2400 cm⁻¹
Absorbance Range0.0000 – 3.000 AU
Baseline Drift<0.001 AU/60 min
Repeatability≤1% (for 20 mg/L oil standard)
Linearity (R²)>0.999
Dimensions550 mm × 380 mm × 150 mm
Weight15 kg
Power Supply220 V ± 22 V AC, 50 Hz ± 1 Hz, 35 VA
Operating Environment5 °C – 35 °C, 20% – 80% RH
InterfaceUSB or RS-232
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelOCMA-355
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelET1200
Price RangeUSD 1,400–7,200
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (Triple-Wavelength IR at 3030 cm⁻¹, 2960 cm⁻¹, 2930 cm⁻¹)
Measurement Range0–1000 mg/L (as oil in water)
Detection Limit0.2 mg/L (in C₂Cl₄ extract)
Accuracy±0.4 mg/L (C < 10 mg/L)
RepeatabilityRSD < 3% (typical)
Resolution0.2 mg/L (in tetrachloroethylene matrix)
Wavenumber Range3400–2400 cm⁻¹
Wavenumber Accuracy±2 cm⁻¹
Measurement Cycle Time≤25 s per sample
Operating Temperature5–35 °C
Power Supply220 V ±10%, 50 Hz
Dimensions500 × 380 × 220 mm
Weight15 kg
Data InterfaceRS-232 serial port
ComplianceGB/T 16488–1996 (China National Standard for Petroleum & Animal/Vegetable Oil in Water)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelOCMA-350
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelET1200
Price RangeUSD 7,000 – 14,000
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (Triple-Wavelength Method at 3030 cm⁻¹, 2960 cm⁻¹, 2930 cm⁻¹)
Measurement Range0–1000 mg/L (as oil in water)
Detection Limit0.2 mg/L (in CCl₄ extract)
Accuracy±5% of reading
Resolution0.1 ppm
Measurement Frequency10 measurements per minute
Wavenumber Range3400–2400 cm⁻¹
Wavenumber Accuracy±2 cm⁻¹
RepeatabilityRSD < 3%
Output InterfaceRS-232
Power Supply220 V ±10%, 50 Hz
Dimensions500 × 380 × 220 mm
Weight15 kg
Operating Temperature5–35 °C
ComplianceGB/T 16488–1996
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelInLab-2300
Price RangeUSD 1,400 – 7,200
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry (Dual-Wavelength & Full-Spectrum Scanning)
Measurement Range0.00–800 mg/L (in extract, using 0.5–4 cm pathlength cells)
Detection Limit<0.4 mg/L (in CCl₄ extract)
<0.004 mg/L (in water sample, 401 extraction ratio, 4 cm quartz cell)
Accuracy±0.8 mg/L (C < 10 mg/L), ±4% (10 ≤ C ≤ 80 mg/L)
Repeatability≤3% (for 20 & 40 mg/L oil standards)
Resolution0.1 mg/L (in tetrachloroethylene)
Wavenumber Range3400–2400 cm⁻¹ (±1 cm⁻¹ repeatability)
Absorbance Range0.0000–2.000 AU
Baseline Drift<0.001 AU/60 min
Sampling Frequency7 measurements/min
Power Supply220 V ±10%, 50 Hz, 40 VA
Dimensions & Weight470 × 380 × 210 mm, ~13 kg
Operating Environment5–35 °C, 20–90% RH
Battery Life~6 h (integrated Li-ion)
InterfaceRS-232 or USB (configurable)
ComplianceHJ 637–2018 (China), ISO 9377-1:2000 (Petroleum Hydrocarbons), ASTM D7066–22 (Oil in Water by IR)