| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | JWQ03C |
| Price Range | USD 7,000 – 14,000 |
| Measurement Principle | Euler Buckling-Based Mechanical Bending Analysis |
| Sample Length Range | 0.5 mm – 20 mm |
| Minimum Fiber Diameter | 1 µm |
| Max Length-to-Diameter Ratio | 200 |
| Force Resolution | 0.001 mN |
| Imaging Resolution | 12 pixels/µm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JQ03B |
| Price Range | USD 7,000 – 14,000 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JDS05B |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | DPCZ-II |
| Pricing | Available Upon Request |
| Detection Principle | Spectrophotometric Absorption (Iodine-Blue Complex Method) |
| Sample Types | Milled rice, wheat, maize (corn), millet |
| Measurement Range | 0–50% (w/w, amylose content) |
| Accuracy | ±1% (relative to reference method per GB/T 15683-2008 or ISO 6647-1) |
| Measurement Time | ~60 seconds per sample (post-extraction) |
| Interface | RS-232 serial communication with Windows-based control software |
| Compliance | Designed for alignment with Chinese national standard GB/T 15683 and international cereal quality testing protocols |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JDF05 |
| Pricing | Available Upon Request |
| Origin | Russia |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SHATOX SX-100K |
| Price | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | IR-2 |
| Pricing | Available Upon Request |
| Measurement Principle | Normal Reflectance Method (via Integrated Blackbody Source) |
| Spectral Bands | 3–5 µm, 8–14 µm, 1–22 µm |
| Emissivity Range | 0.100–0.990 |
| Sensitivity (NEΔε) | 0.001 |
| Accuracy | ±0.02 (for ε > 0.50) |
| Repeatability | ±0.01 |
| Sample Temperature Range | Ambient to 300 °C (with optional heating stage) |
| Sample Diameter | Ø50 mm |
| Measurement Time | <3 s after trigger |
| Display Resolution | 0.001 (LED digital) |
| Interface | RS-232 serial port |
| Power Supply | AC 220 V, 50 Hz |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SHATOX SX-200 |
| Price | Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SHATOX SX-100M |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Alcotest 9510 |
| Pricing | Upon Request |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | SAM-706AC |
| Measurement Principle | Conductivity (Acidity), Refractometry (Brix) |
| Brix Range | 0.0–45.0% |
| Acidity Range (as citric acid) | 0.00–3.50% |
| Accuracy | ±0.2% Brix, ±0.05% acidity |
| Resolution | 0.1% Brix, 0.01% acidity |
| Temperature Compensation | Automatic, 5–70 °C |
| Measurement Time | 3 s (Brix), 8 s (acidity) |
| Power Supply | 9 V alkaline battery or AC 220 V/60 Hz |
| Sample Compatibility | Citrus, grape, apple, strawberry, peach, kiwifruit, tomato, plum, cherry, raspberry, mulberry, pomegranate, pineapple, mango, pear, orange, etc. |
| Accessories | 30 mL syringe sampler, filtration unit, pipette with tips, diluent vial, shade hood, anti-theft lock, user manual, AC adapter |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | GMK-303 (Chinese UI) |
| Instrument Type | Seed/Grain Moisture Analyzer |
| Moisture Range (%) | 36 |
| Minimum Weighing Readability (g) | 0.001 |
| Sample Mass (g) | 1 |
| Heating Temperature Range (°C) | –10 to 40 |
| Accuracy | ±0.5% |
| Resolution | 0.1% |
| Display | Digital LCD |
| Temperature Compensation | Automatic |
| Power Supply | 4 × 1.5 V AA batteries |
| Dimensions (L×W×H) | 164 × 94 × 40 mm |
| Weight | ~1.2 kg |
| Warranty | 12 months from delivery (excluding misuse or physical damage) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DPCZ-I |
| Price Range | USD 1,400 – 7,000 |
| Moisture Accuracy | ±0.5% |
| Amylose Content Accuracy | ±1% |
| Chalkiness Degree Accuracy | ±1% |
| Chalky Grain Ratio Accuracy | ±2% |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACID F5 |
| Price Range | USD 1,400 – 7,200 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | JQN04C |
| Price Range | USD 7,000 – 14,000 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JQ05 |
| Price Range | USD 7,000 – 14,000 |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | GMK-835N |
| Price Range | USD 1,400 – 7,000 |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | SAM-700S |
| Measurement Principle | Refractive Index (Brix) & Electrical Conductivity (Acidity) |
| Brix Range | 0–35.0% w/w |
| Acidity Range | 0–3.50% (as citric acid) |
| Brix Resolution | 0.1% |
| Acidity Resolution | 0.01% |
| Brix Accuracy | ±0.2% |
| Acidity Accuracy | ±0.05% |
| Temperature Compensation | Automatic (ATC, 10–40 °C) |
| Power Supply | 9 V alkaline battery (1×) |
| Dimensions | 200 × 132 × 62 mm |
| Weight | ~2.0 kg |
| Accessories | Pipette, pipette tips, fruit juice extractor tool, dilution cup, syringe, light-blocking cap, user manual |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NH300 |
| Pricing | Available Upon Request |
| Measurement Geometry | 8°/diffuse |
| Aperture | 8 mm |
| Detector | Silicon Photodiode |
| Illuminant | LED (Blue-LED Excited Phosphor) |
| Inter-instrument Agreement | ≤0.40 ΔE*ab |
| Repeatability | 0.10 ΔE*ab (30 measurements on white tile) |
| Memory Capacity | 100 standards / 8,000 samples |
| Weight | 500 g |
| Dimensions | 205 × 70 × 100 mm |
| Power Supply | Rechargeable Li-ion Battery (3.7 V, 3200 mAh) |
| Lamp Lifetime | >1.6 million measurements (≥5 years) |
| Charging Time | ~8 h for full charge |
| Measurements per Charge | ~3,000 in 8 h |
| Operating Conditions | 10–40 °C, 0–85% RH (non-condensing) |
| Interface | USB |
| Optional Accessories | Extended Φ8 mm probe for concave surfaces, Thermal Mini Printer |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JDS05A |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JQ03D |
| Price Range | USD 7,000 – 14,000 |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | SENSE I |
| Measurement Range | 0.0–53.0 %Brix |
| Minimum Resolution | 0.1 %Brix |
| Accuracy | ±0.2 %Brix |
| Automatic Temperature Compensation (ATC) | 5–70 °C |
| Sample Volume | 0.1–0.3 mL |
| Measurement Time | ~3 seconds |
| Power Supply | 1 × 9V alkaline battery |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-835F |
| Measurement Principle | Conductometric (Platinum-Coated Electrode) |
| Temperature Compensation | Automatic (ATC) |
| Data Averaging | Multi-measurement statistical averaging |
| Calibration | Fully automated internal calibration routine |
| Fruit Mode Selection | Single pre-programmed fruit category (Citrus, Orange, Pineapple, Kiwi, Apple, Grape, Pear, Strawberry, Peach, Plum, Melon) |
| Power Indicator | Low-battery warning |
| Origin | Poland |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | MD-20 / MD-25 |
| Price | Upon Request |
| Rope Diameter Range | MD-20: 8–22 mm |
| MD-25 | 10–25 mm |
| Operating Speed | 0.1–2.5 m/s |
| Sensitivity Adjustment | 10-level potentiometer |
| Indicators | LB (red, low battery), OK (green, no defect), D (yellow, defect detected, flashing), DM (red, defective rope, steady) |
| Audible Alarm | Yes |
| Power Supply | Rechargeable 9 V battery |
| Operating Temperature | Standard models: −10 °C to +40 °C |
| MD-20L variant | −25 °C to +40 °C |
| Dimensions (L×W×H) | 205 × 46 × 280 mm (with roller guide) |
| Weight | MD-20: 4.5 kg |
| MD-25 | 4.9 kg |