Empowering Scientific Discovery

Beijing Shangdetong Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMadur
OriginAustria
ModelCMS-7
Instrument TypeContinuous Emission Monitoring System (CEMS)
Accuracy±5% of reading
Repeatability≤2%
Response Time (T90)45 s
Stability≤5% drift over 1 h
Gas Detection PrincipleNDIR (CO₂, CH₄, CO), Electrochemical (CO, NO, NO₂, SO₂, H₂S, H₂), Paramagnetic/Zirconia (O₂)
Temperature Range (Operating)10–40 °C
Dimensions (L×H×W)600 × 635 × 518 mm
Weight (excl. probe)48 kg
Display320×240 pixel backlit LCD
Data Storage256 MB MMC card
Analog Outputs8 channels, 0–10 V / 0/4–20 mA
CommunicationRS232C
Power Supply230 VAC, 50–60 Hz
Sample Flow Rate90 L/h (adjustable diaphragm pump)
Condensate HandlingPeltier-cooled condensate separator with peristaltic pump
Heated Sampling Line3 m, integrated 20 µm filter
ProbeHeated gas probe (standard 300 mm, custom lengths available)
Pressure MeasurementDifferential and absolute pressure sensors (±25 hPa, 800–1200 hPa), resolution 0.1–1 Pa (configurable)
Flow VelocityPitot tube-based, 1–30 m/s
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelET5101
Price RangeUSD 7,000–14,000
Instrument TypeContinuous Emission Monitoring System (CEMS) Compliant Portable Analyzer
Indication Error±0.2% FS
Repeatability<2% RSD
Response Time≤15 s (T90)
Stability<5% drift over 8 h
Measured ParametersParticulate Matter (PM) concentration via gravimetric filtration + Flue Gas composition (O₂, SO₂, NO, NO₂, CO, CO₂)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelYQ3000C
Price RangeUSD 7,000 – 14,000
Instrument TypePortable Flue Gas & Particulate Emission Analyzer
Sampling PrincipleIsokinetic Pitot Tube Sampling + Gravimetric Collection + Potentiostatic Electrolytic Gas Sensing
ComplianceHJ/T 48–1999, JJG 968–2002, JJG 680–2007
Added to wishlistRemoved from wishlist 0
Add to compare
OriginAustria
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelmaMoS-100/200
Price RangeUSD 14,000 – 42,000
Instrument TypeContinuous Emission Monitoring System (CEMS)
Indication Error≤ ±5% FS
Repeatability≤ 2% RSD
Response Time (T90)≤ 45 s
Stability≤ 5% FS drift over 1 h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMadur
OriginAustria
ModelPHOTON S
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement PrincipleNon-Dispersive Infrared (NDIR) + Electrochemical Sensors
Accuracy (Indication Error)≤3% FS
Repeatability≤2% FS
Response Time (T90)45 s
Stability≤5% FS/7 days
Measured GasesSO₂, NO, NO₂, O₂, CO, CO₂
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMadur
OriginAustria
ModelGA-21plus
Instrument TypePortable Flue Gas Analyzer (not CEMS)
Measurement PrincipleElectrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, Cl₂, H₂) & NDIR (CO₂, CH₄)
O₂ Range0–25% (electrochemical) / 0–100% (bias-cell)
CO Range0–20,000 ppm
NO/NOₓ Range0–5,000 ppm
NO₂ Range0–1,000 ppm
SO₂ Range0–5,000 ppm
H₂S Range0–1,000 ppm
Cl₂ Range0–300 ppm
H₂ Range0–1,000 ppm
CO₂ Range0.5% or 0–100% (NDIR)
CH₄ Range0.5% or 0–100% (NDIR)
Gas Temperature–40 to 1600 °C
Ambient Temperature–40 to 100 °C
Pressure Range (Differential)–25 to +25 hPa
Atmospheric Pressure800–1200 mbar
Flow Velocity0–50 m/s
Response Time (T₉₀)45 s (gas sensors), 30 s (temperature), 10 s (pressure/flow)
Accuracy±5 ppm or ±5% rel (electrochemical gases)
Repeatability5 ppm
Zero Drift Stability≤5% over 1 h
DisplayBacklit graphical LCD (simultaneous multi-parameter view)
Data StorageInternal memory for 1024 records (10 databases), up to 10 variables per record
InterfaceRS232C
Power230 V/50 Hz or 110 V/60 Hz AC
Dimensions460 × 170 × 160 mm
Weight6.2 kg
Operating Temp.10–50 °C
Storage Temp.–20 to +55 °C
Probe Max Temp.≥800 °C
ComplianceMeets SCAQMD requirements including automatic O₂ correction
Added to wishlistRemoved from wishlist 0
Add to compare
OriginAustria
TypeImported Instrument
ModelGA-60
Sensor ConfigurationStandard 5 electrochemical sensors + optional IR sensors (CO₂, CH₄, N₂O) and additional electrochemical sensors (H₂S, H₂)
Flow Rate1.63 L/min (Bacharach-compliant)
Data Storage256 MB (~1 million records)
Display320 × 240 pixel backlit LCD
Printer57 mm thermal dot-matrix with graphics
PowerRechargeable 12 V / 2.2 Ah lead-acid battery (10 h charge, ~6 h operation) or 110/220 V AC, 50–60 Hz
Dimensions500 × 410 × 180 mm
Weight9.5 kg
Operating Temperature10–50 °C
Storage Temperature−20–55 °C
Humidity5–90 % RH (non-condensing)
Pressure Resolution1 Pa (differential), 0.1 hPa (ambient, optional)
Temperature ChannelsUp to 8 (4 thermocouples + 4 thermistors, optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMadur
OriginAustria
ModelPHOTON
Instrument TypePortable Flue Gas Analyzer
Measurement PrincipleNon-Dispersive Infrared (NDIR) + Electrochemical Sensors
Accuracy≤3% FS
Repeatability≤2% FS
Response Time (T90)45 s
Stability≤5% FS
Measured GasesSO₂, NO, NO₂, CO, CO₂, CH₄, VOCs (via optional electrochemical sensors), O₂
Operating Temperature0–50 °C
Storage Temperature−20–+55 °C
Dimensions (W×H×D)500 × 340 × 150 mm
Weight~7 kg
Power Supply90–230 VAC, 50–60 Hz
DisplayBacklit LCD, 320 × 240 px
Data Memory65,535 records
Analog I/O8-channel configurable voltage/current input/output
ComplianceDesigned for EN 15267, EN 14181, ISO 12039, and EPA Method 6C/7E compatibility
Added to wishlistRemoved from wishlist 0
Add to compare
OriginAustria
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelmaMoS-100-400
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement Accuracy≤5% FS
Repeatability≤2% FS
Response Time (T90)45 s
Stability≤5% FS over 30 days
Sensor OptionsElectrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, Cl₂, H₂) & NDIR (CO, CO₂, CH₄, N₂O)
HousingIP54-rated ABS enclosure
Power Supply24 V AC, ~8 W
Operating Temperature0–40 °C
Storage Temperature−20–+55 °C
Dimensions (H×W×D)380 × 300 × 140 mm
Weight~4 kg
Zero/Measurement CycleFully automated dual-phase sequence with independent timing control
Output Signals4–20 mA and 0–10 V per channel
Digital InterfaceRS232
NDIR Response TimeT90 < 10 s
Built-in Sample ConditioningPeltier-cooled dryer, particulate filter, condensate peristaltic pump
CalibrationFactory-calibrated sensors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMadur
OriginAustria
ModelGA-12plus
Instrument TypePortable Flue Gas Analyzer
Accuracy (Indication Error)≤5%
Repeatability≤2%
Response Time45 s
Stability≤5%
Optional Electrochemical SensorsNO, NO₂, SO₂, H₂S
Ambient CO Resolution0.1 ppm
Temperature Measurement RangeFlue Gas & Ambient Air
Differential Pressure Resolution0.1 Pa
Bacharach Smoke Number Test (Electronically Controlled Flow1.631 L/min)
Calculated ParametersCO₂, Combustion Efficiency, Excess Air, Lambda, Losses, etc.
Data Storage32 Reports
DisplayBacklit LCD (66 × 36 mm)
Battery LifeUp to 75 h (6 V, 4×AA Alkaline or Rechargeable)
Operating Temperature10–50 °C
Storage Temperature−20–+55 °C
Dimensions (W×D×H)245 × 90/128 × 60 mm
Weight700 g
Probe Length150 mm
Gas Hose Length2 m
In-line Filter20 µm
InterfaceIR, RS-232C
ComplianceEN 50379-1 & EN 50379-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMadur
OriginAustria
ModelGA-60
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement PrincipleElectrochemical & NDIR (Non-Dispersive Infrared) Sensor Technology
Accuracy (CO)±5 ppm
Repeatability≤2%
Response Time (T90)45 s
Stability≤5%
Gas Channels5 standard electrochemical sensors + up to 2 additional electrochemical + 3 NDIR sensors
Data Storage1 million records (256 MB)
Display320 × 240 pixel backlit LCD
PrinterIntegrated 57 mm dot-matrix thermal printer
Power Supply12 V / 2.2 Ah rechargeable lead-acid battery (6 h operation) or 110–220 V AC adapter
Dimensions (L×H×W)500 × 410 × 180 mm
Weight9.5 kg
Operating Temperature10–50 °C
Storage Temperature−20–55 °C
Humidity Range5–90% RH (non-condensing)
Pressure Resolution1 Pa (differential), 0.1 hPa (ambient, optional)
Temperature Inputs8 channels (4 thermocouples + 4 thermistors, optional)
Flow ControlElectronically regulated peristaltic pump (90 L/h nominal, 1.63 L/min sampling flow)
Sample ConditioningPeltier-based gas dryer + heated probe (300 mm standard) + 5 µm/20 µm particulate filters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMadur
OriginAustria
ModelGA40Tplus
Instrument TypeContinuous Emission Monitoring System (CEMS)
Accuracy±5 ppm
Repeatability≤2%
Response Time45 s
Stability≤5%
Sensor ConfigurationUp to 8 sensors (6 electrochemical + 2 infrared)
Analog Inputs6 (voltage, current, temperature)
Analog Outputs2 (optional)
Data Storage1024 records across 10 databases
Display128×112-pixel backlit LCD
PrinterHigh-speed dot-matrix, 56 mm paper
Power110/230 V AC, 50/60 Hz
Dimensions460 × 170 × 160 mm
Weight10 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0