PricingAvailable Upon Request
Measurement Range (Radon Concentration)100–100,000 Bq/m³
Measurement Range (Radon Exhalation Rate)0.001–1.000 Bq/m²·s
Sensitivity≥1.5 s⁻¹ per (Bq/L)
Energy Threshold50 keV
Nonlinearity≤10%
Repeatability≤10%
Stability≤5%
Operating Temperature0–40 °C
Relative Humidity≤90% RH at 40 °C
Lead Chamber Dimensions & Weight34 × 15 × 20 cm, 25 kg
Control Unit Dimensions & Weight50 × 31 × 22 cm, 1.5 kg
Calibration & CertificationCertified and calibrated by the National Institute of Metrology (NIM), PRC
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelFD216
Price RangeUSD 1,400–4,200
Sampling MethodActive Pump-Driven
Measurement Range3–100,000 Bq/m³
Minimum Detectable Concentration3 Bq/m³
Response Time (Air)30 min
Detector SystemZnS(Ag) Scintillation Screen Coupled with Photomultiplier Tube (PMT)
Sensitivity≥0.68 cpm/(Bq·m⁻³)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelFT648
PricingAvailable Upon Request
Sensitivity3.3 Bq/m³ (radon, 95% confidence level)
Intrinsic Error<30% (typical)
Background Count Rate≤25 cph
Power SupplySampling Pump Battery: 18 V Ni–Cd
Main Unit Battery12 V Ni–Cd
Operating Temperature0–40 °C
DetectorØ65 mm ZnS(Ag) Scintillation Detector
Sampling Pump Flow Rate30–40 L/min
Decay Chamber Volume14.8 L
DimensionsØ170 mm × 800 mm
Weight18 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelFD218
Price RangeUSD 4,200–7,000
Sampling MethodActive Pump-Driven
Measurement Range2–999,999 Bq/m³
Minimum Detectable Concentration≤2 Bq/m³
Response TimeShort
DetectorPassivated Implanted Planar Silicon (PIPS)
Sensitivity≥0.017 cpm/(Bq·m⁻³) [0.63 cpm/(pCi/L)]
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelFD125
Price RangeUSD 7,000–14,000 (FOB)
Sampling MethodPassive Collection
Measurement Range0–10 Bq/m³
Minimum Detectable Concentration0.01 Bq/m³
Response Time300 s
Detector Background≤100 counts/s
Sensitivity Accuracy±10%
Operating Temperature0–45 °C
Relative Humidity Limit≤95% RH
Power Supply+9–10 V DC for amplifier
Weight16 kg (excluding scaler unit)