| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGM6208 |
| Instrument Type | Portable |
| Detection Targets | Multi-component (EC, LEL, TC, PID, IR, Gamma) |
| Measurement Range | 0–1 ppm (select sensors) |
| Repeatability | ≤1% FS |
| Resolution | 0.1 ppm (standard) |
| Response Time (T90) | ≤60 s |
| Zero Drift | ≤±5% FS (per 8 h) |
| Span Drift | ≤±1% FS (per 8 h) |
| Linearity Error | ≤±2% FS |
| Certifications | ATEX II 1G Ex ia IIC T4 Ga, UL 913 Class I Div 1 Groups A–D, CSA C22.2 No. 152, IECEx, CMC |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XP-3110 |
| Price Range | USD 700–1,400 |
| Instrument Type | Portable |
| Detectable Gases | Combustible Gases (e.g., Methane, Propane, Butane, LPG, Town Gas) |
| Response Time | ≤45 s (T90) |
| Measurement Accuracy | ±5% of Full Scale |
| Measurement Ranges | 0–10% LEL and 0–100% LEL (auto-ranging) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DUSTMATE |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | P-5L2C |
| Price | Upon Request |
| Detection Principle | Light Scattering (Nephelometry) |
| Sensitivity | 0.01 mg/m³ |
| Measurement Range | 0.01–100 mg/m³ |
| Sampling Duration Options | 0.1, 1, 3, 5, 10, 15 min + manual mode |
| Repeatability Error | ±2% |
| Accuracy | ±10% |
| Display | 4-digit LCD showing CPM and mass concentration (mg/m³) |
| Data Output | RS232 serial interface for PC connection or dedicated thermal printer |
| Data Storage | 99 measurement records |
| Environmental Operating Temperature | 0–40 °C |
| Power Supply | NiMH ×9 rechargeable battery (12 h continuous operation) |
| Dimensions | 202 × 85 × 168 mm |
| Weight | 2.4 kg |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | SW1 |
| Pricing | Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GCG1000 |
| Pricing | Available Upon Request |
| Measurement Principle | Optical Scattering |
| Range | 0–1000 mg/m³ |
| Accuracy | ≤ ±10% |
| Sampling Flow Rate | 2 L/min |
| Output Options | 200–1000 Hz Frequency Signal or RS485 |
| Display | 4-digit LED |
| Alarm Output | 1-channel Optocoupler |
| Power Supply | 18 V DC (Intrinsically Safe) |
| Current Draw | ≤ 200 mA |
| Dimensions | 270 × 145 × 73 mm |
| Weight | 1.6 kg |
| Explosion Protection | Exib I |
| Operating Environment | 0–40 °C, ≤95% RH, 86–110 kPa |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 202 |
| Pricing | Available Upon Request |
| Detection Principle | High-Sensitivity Indium Oxide-Based Heated Semiconductor Sensor |
|---|---|
| Display | 64×128 Dot-Matrix LCD |
| Measurement Modes | Real-Time Monitoring / Batch Sampling |
| Odor Intensity Range | 0–40 (Odor Unit Scale) |
| Odor Level Range | 0–2000 (Arbitrary Unit Scale) |
| Data Storage Capacity | Up to 8,188 points (Monitoring Mode), Up to 4,095 points (Batch Mode) |
| Operating Environment | 0°C–40°C, 30–80% RH |
| Power Supply | 4 × AA Alkaline Batteries (≈8 h operation) or Optional AC Adapter |
| Dimensions & Weight | 84 × 275 × 40 mm, ≈640 g (incl. batteries) |
| Analog Output | 0–200 mV DC (scalable to either 0–2000 or 0–40 scale) |
| Communication Interface | RS-232C with Dedicated PC Software |
| Accessories Included | Activated Carbon Filter, Exhaust Filter, Suction Kit, Metal Cap for Tubing, AC Adapter, Carrying Case, Connectorized Output Cable, Odor Analysis Software Suite, 4 × AA Batteries, 1 × PTFE Sampling Tube, 20 × Filter Cloths, 2 × Activated Carbon Packs |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CCHZ-1000 |
| Pricing | Available Upon Request |
| Dust Measurement Range | 0–1000 mg/m³ |
| Measurement Accuracy | < ±10% |
| Stability Relative Error | ±2.5% |
| Sampling Flow Rate | 2 L/min |
| Flow Rate Accuracy | < ±2.5% |
| Intrinsic Safety Rating | ibdI (150 °C) |
| Compliance | MT163–1997 |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | CMS-7 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Accuracy | ±5% of reading |
| Repeatability | ≤2% |
| Response Time (T90) | 45 s |
| Stability | ≤5% drift over 1 h |
| Gas Detection Principle | NDIR (CO₂, CH₄, CO), Electrochemical (CO, NO, NO₂, SO₂, H₂S, H₂), Paramagnetic/Zirconia (O₂) |
| Temperature Range (Operating) | 10–40 °C |
| Dimensions (L×H×W) | 600 × 635 × 518 mm |
| Weight (excl. probe) | 48 kg |
| Display | 320×240 pixel backlit LCD |
| Data Storage | 256 MB MMC card |
| Analog Outputs | 8 channels, 0–10 V / 0/4–20 mA |
| Communication | RS232C |
| Power Supply | 230 VAC, 50–60 Hz |
| Sample Flow Rate | 90 L/h (adjustable diaphragm pump) |
| Condensate Handling | Peltier-cooled condensate separator with peristaltic pump |
| Heated Sampling Line | 3 m, integrated 20 µm filter |
| Probe | Heated gas probe (standard 300 mm, custom lengths available) |
| Pressure Measurement | Differential and absolute pressure sensors (±25 hPa, 800–1200 hPa), resolution 0.1–1 Pa (configurable) |
| Flow Velocity | Pitot tube-based, 1–30 m/s |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XP-308II |
| Price | Available Upon Request |
| Detection Gas | Formaldehyde (HCHO) |
| Detection Principle | Potentiostatic Electrolytic Sensor |
| Measurement Range (Standard) | 0.00–3.00 ppm |
| Minimum Resolution | 0.01 ppm |
| Sampling Method | Integrated Micro-Pump (Active Draw) |
| Display | Dual-mode — Digital Numeric + Analog Bar Graph |
| Power Supply | Six AA Alkaline Batteries or Optional DC Adapter |
| Battery Life | Approx. 100 Measurements per Set |
| Filter Lifetime | Approx. 100 Measurements (DNPH Cartridge) |
| Operating Temperature | 0 °C to +40 °C |
| Dimensions (W×H×D) | 175 × 140 × 86 mm |
| Weight | 2.5 kg |
| Standard Accessories | 5 × DNPH Filters, 6 × AA Batteries, Leather Carrying Case, Sampling Tube, 10 × Replacement Filter Discs, Stainless Steel Tweezers |
| Optional Accessories | DC Power Adapter, Data Export Software, RS-232 Communication Cable |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET5101 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Compliant Portable Analyzer |
| Indication Error | ±0.2% FS |
| Repeatability | <2% RSD |
| Response Time | ≤15 s (T90) |
| Stability | <5% drift over 8 h |
| Measured Parameters | Particulate Matter (PM) concentration via gravimetric filtration + Flue Gas composition (O₂, SO₂, NO, NO₂, CO, CO₂) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JWL-IIB202 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LD-3F |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JWL-IIC |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M40 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ventis™ MX4 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Type | Portable Gas Detector |
| Target Gas | O₂ in Combustion Exhaust |
| Response Time | ≤45 s |
| Accuracy | ±0.3 vol% (per JIS T 8201) |
| Measurement Range | 0–25.0 vol% |
| Intrinsic Safety Rating | Ex ib IIB T3 |
| Power | 4× AA alkaline batteries (≈100 h operation, no backlight/no alarm) |
| Dimensions | 82 × 162 × 36 mm |
| Weight | ≈450 g (battery-free) |
| Detection Principle | Membrane-type Galvanic Cell |
| Display | Backlit LCD with dual numeric + bar-graph readout |
| Alarm | Audible buzzer + flashing red LED (configurable threshold, default 18.0 vol%) |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YQ3000C |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Portable Flue Gas & Particulate Emission Analyzer |
| Sampling Principle | Isokinetic Pitot Tube Sampling + Gravimetric Collection + Potentiostatic Electrolytic Gas Sensing |
| Compliance | HJ/T 48–1999, JJG 968–2002, JJG 680–2007 |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | maMoS-100/200 |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Indication Error | ≤ ±5% FS |
| Repeatability | ≤ 2% RSD |
| Response Time (T90) | ≤ 45 s |
| Stability | ≤ 5% FS drift over 1 h |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | PHOTON S |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) + Electrochemical Sensors |
| Accuracy (Indication Error) | ≤3% FS |
| Repeatability | ≤2% FS |
| Response Time (T90) | 45 s |
| Stability | ≤5% FS/7 days |
| Measured Gases | SO₂, NO, NO₂, O₂, CO, CO₂ |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 4160 |
| Pricing | Available Upon Request |
| Measurement Range | 0–19.99 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±2% of reading + 0.01 ppm |
| Response Time | < 60 s |
| Linearity | ±1.0% |
| Repeatability | ±0.5% |
| Zero Drift | ±1.0% per 24 h |
| Span Drift | ±2.0% per 24 h |
| Sampling Method | Continuous pump-suction, 1 L/min |
| Dimensions | 178 mm × 102 mm × 225 mm |
| Weight | 2 kg |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | GA-21plus |
| Instrument Type | Portable Flue Gas Analyzer (not CEMS) |
| Measurement Principle | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, Cl₂, H₂) & NDIR (CO₂, CH₄) |
| O₂ Range | 0–25% (electrochemical) / 0–100% (bias-cell) |
| CO Range | 0–20,000 ppm |
| NO/NOₓ Range | 0–5,000 ppm |
| NO₂ Range | 0–1,000 ppm |
| SO₂ Range | 0–5,000 ppm |
| H₂S Range | 0–1,000 ppm |
| Cl₂ Range | 0–300 ppm |
| H₂ Range | 0–1,000 ppm |
| CO₂ Range | 0.5% or 0–100% (NDIR) |
| CH₄ Range | 0.5% or 0–100% (NDIR) |
| Gas Temperature | –40 to 1600 °C |
| Ambient Temperature | –40 to 100 °C |
| Pressure Range (Differential) | –25 to +25 hPa |
| Atmospheric Pressure | 800–1200 mbar |
| Flow Velocity | 0–50 m/s |
| Response Time (T₉₀) | 45 s (gas sensors), 30 s (temperature), 10 s (pressure/flow) |
| Accuracy | ±5 ppm or ±5% rel (electrochemical gases) |
| Repeatability | 5 ppm |
| Zero Drift Stability | ≤5% over 1 h |
| Display | Backlit graphical LCD (simultaneous multi-parameter view) |
| Data Storage | Internal memory for 1024 records (10 databases), up to 10 variables per record |
| Interface | RS232C |
| Power | 230 V/50 Hz or 110 V/60 Hz AC |
| Dimensions | 460 × 170 × 160 mm |
| Weight | 6.2 kg |
| Operating Temp. | 10–50 °C |
| Storage Temp. | –20 to +55 °C |
| Probe Max Temp. | ≥800 °C |
| Compliance | Meets SCAQMD requirements including automatic O₂ correction |
| Origin | Austria |
|---|---|
| Type | Imported Instrument |
| Model | GA-60 |
| Sensor Configuration | Standard 5 electrochemical sensors + optional IR sensors (CO₂, CH₄, N₂O) and additional electrochemical sensors (H₂S, H₂) |
| Flow Rate | 1.63 L/min (Bacharach-compliant) |
| Data Storage | 256 MB (~1 million records) |
| Display | 320 × 240 pixel backlit LCD |
| Printer | 57 mm thermal dot-matrix with graphics |
| Power | Rechargeable 12 V / 2.2 Ah lead-acid battery (10 h charge, ~6 h operation) or 110/220 V AC, 50–60 Hz |
| Dimensions | 500 × 410 × 180 mm |
| Weight | 9.5 kg |
| Operating Temperature | 10–50 °C |
| Storage Temperature | −20–55 °C |
| Humidity | 5–90 % RH (non-condensing) |
| Pressure Resolution | 1 Pa (differential), 0.1 hPa (ambient, optional) |
| Temperature Channels | Up to 8 (4 thermocouples + 4 thermistors, optional) |