OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCR4200
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelCTL-12
PricingAvailable Upon Request
Detection Limit5 mg/L COD
Measurement Range20–1200 mg/L COD
Repeatability≤0.87%
Optical Stability0.001 A/5 min
Sample ThroughputUp to 12 samples per batch
Digestion Time10 min at 165 °C
Measurement Wavelength610 nm
Chloride Interference Tolerance≤900 mg/L Cl⁻ (open-tube mode)
Data Storage9 pre-programmed calibration curves
Display5-digit LED (time, date, absorbance, concentration, slope)
Power Supply220 V, 50 Hz, 200–700 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZYKX
OriginBeijing, China
ModelInLab-2022
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleRapid Digestion Spectrophotometry
Wavelength Range590–610 nm
COD Range5–15,000 mg/L (high-range), 5–150 mg/L (low-range), 0–50 mg/L (permanganate method)
Repeatability≤ ±5%
Measurement Time20 min (typical COD cycle)
Batch Capacity15 samples
Temperature Control Range45–200 °C
Temperature Uniformity≤ 1 °C
Power SupplyAC 220 V ±10%, 50 Hz
Dimensions370 × 250 × 140 mm
WeightApprox. 4.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-made)
ModelET3150B/ET1150M
Instrument TypeBenchtop Laboratory Analyzer
Power Supply220 V AC, 50 Hz
Operating Temperature5–50 °C
Relative Humidity20–85 % RH
Wavelength Accuracy±2 nm
Wavelength Selection420 nm and 610 nm (LED-based optical system)
Photometric Accuracy±8 % of full scale
RepeatabilityRSD ≤ 3 %
Photometric StabilityΔA < 0.005 A within 20 min
Measurement ModesAbsorbance, Transmittance, Concentration
Built-in Test ProgramsCOD, TN, TP, NH₃-N, F⁻
Preloaded Calibration Curves6
User-defined Curve StorageSupported
ET3150B Digestion Block Capacity24 × Φ16 × 100 mm tubes
Digestion Temperature Accuracy±1 °C
COD Digestion Temp165 °C ±1 °C
TN/TP Digestion Temp105 °C
Timer Range1–1860 min (31 h)
DisplayLCD with full Chinese interface
Heating Rate20 → 165 °C in ≤10 min
Safety FeaturesAuto-shutdown, over-temperature alarm, timer alert
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelCM-02
PriceUpon Request
Detection Range10–200 mg/L (low range), 50–2500 mg/L (high range)
LOD3 mg/L
Wavelength610 nm
Accuracy±5% (low range), ±4% (high range)
Chloride Interference Tolerance1000 mg/L (low), 2500 mg/L (high)
Measurement Time10–15 min
Heating Capacity25 tubes, 0–180 °C, timer 10–199 min
Optical Stability±0.003/5 min (blank)
Display Resolution0.001
Operating Temperature5–35 °C
Storage Temperature−10–45 °C
Power Consumption≤30 W (heater), ≤10 W (analyzer)
Weight3.0 kg (analyzer), 3.5 kg (full system)
Dimensions330 × 320 × 170 mm
ComplianceHJ/T 399–2007, EPA Method 410.4 (adapted), Standard Methods 5220D (COD by Closed Reflux Colorimetric)