Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelJC2000X
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelJC2000C
PricingAvailable Upon Request
Stage Platform100 × 100 mm
Motion ControlManual or Motorized 3-Axis Translation Stage
Dispensing SystemManual or Automated Syringe Pump
ImagingDigital CCD Camera (25 fps)
Tilt CapabilityAdjustable CCD Mount
Optical LensContinuous Zoom Lens (0.7×–4.5×), Domestic or Imported
Optional Heating StageAmbient to 100 °C
Optional Sample Oscillation Stage±15°
Optional AccessoriesFiber Holder, Fabric Tension Frame, Plate Insertion Module, Pendant Drop Module
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelSCI-1700
Price RangeUSD 14,000 – 28,500
Instrument ClassHigh-Temperature Vacuum Contact Angle Analyzer
Form FactorBenchtop Laboratory System
Contact Angle Range0–180°
Contact Angle Accuracy±1° (θ/2 method), ±0.1° (automated circle fitting)
Sample Stage Dimensions100 × 100 mm
Image Magnification55–320 pixels/mm
Surface/Interfacial Tension Range0.01–1000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Maximum Operating Temperature1600 °C (in inert atmosphere)
Vacuum Limit≤5×10⁻⁵ Pa (with turbo-molecular + backing pump configuration)
Heating Control40-segment programmable PID via B-type thermocouples (Pt/Rh)
Temperature Resolution±0.1 °C (<1000 °C), ±1 °C (≥1000 °C)
Cooling SystemClosed-loop water chiller (5–35 °C, 10–20 L/min flow, 1.0–1.3 bar pressure, 1200 W cooling capacity)
Optical System300-mm working distance telecentric lens, 0.7–4.5× continuous zoom, industrial-grade low-light color CCD (1.3 MP)
Software CapabilitiesMulti-method contact angle calculation (θ/2, tangent, circle/ellipse/curve fitting), time- and temperature-triggered image capture (min. interval: 0.1 s), left/right asymmetry analysis, automated averaging, GLP-compliant data logging with timestamped image–value pairing and Excel export
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelJC2000DM
Price RangeUSD 7,000–14,000
Instrument ClassVideo-Based Optical Contact Angle Analyzer
Form FactorBenchtop Laboratory System
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Fixed Sample Stage Dimensions100 × 80 mm
Optical Magnification0.7×–4.5× Continuous Zoom
Surface/Interfacial Tension Range0–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional OriginDomestic (PRC)
ModelJC2000D
PricingUpon Request
StageManual or Motorized 3-Axis Sample Stage
DispenserManual Precision Syringe System (10 µL / 100 µL)
CameraUSB 2.0 Industrial CCD, 700 TV Lines, 25 fps
Optical Zoom0.7×–4.5× Continuous Zoom Lens (with Post-Zoom Magnification
Effective Pixel Resolution50–318 px/mm)
Light SourceAdjustable Monochromatic LED Cold Light
Tilt Platform±15° Manual Sample Tilting Stage (Optional)
Rotation Platforms360° Vertical & Horizontal Rotational Stages (Optional)
Heating StageAmbient to 100 °C (Optional)
AccessoriesFiber Holder, Fabric Stretch Frame, Insertion Plate, Sessile Drop Arrest Device (All Optional)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Instrument TypeBenchtop Laboratory System
Measurement PrincipleOptical Imaging (Video-Based Drop Shape Analysis)
Contact Angle Range0°–180°
Contact Angle Resolution±0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface Tension Resolution0.01 mN/m
Optical Magnification7× (motorized, software-controlled)
Field of View (FOV)3.2–23 mm
High-Speed Camera311 fps (standard), optional full-frame ultra-high-speed up to 20,000 fps
Image Resolution780 × 580 pixels (standard)
Sample Stage Dimensions (max. accommodated)320 mm (W) × ∞ (D) × 275 mm (H)
Stage MobilityMotorized X/Y/Z translation (X/Y: ±100 mm
Z±38 mm)
Dispensing SystemsDual automated syringe modules (0.01 µL minimum step), manual dispensing unit, auto-refill & auto-cleaning module, dedicated 50 nL precision dosing system
Data Throughput800 MB/s
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelDSA100
Instrument TypeBenchtop Laboratory System
Contact Angle Measurement Range0–180°
Contact Angle Resolution±0.01°
Contact Angle Accuracy0.1°
Sample Stage Dimensions300 × 150 mm (standard), extendable to 500 × 48 mm
Optical Magnification0.7× (adjustable via zoom lens
FOV diagonal1.6–11 mm)
Surface/Interfacial Tension Measurement Range0.01–1000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
High-Speed Camera Options60 fps (standard), up to 1000 fps (optional), customizable to 10,000+ fps
Temperature Control Range (Peltier)–30 to +160 °C
Extended Thermal Stage (TC21)–60 to +400 °C
Humidity Control Chamber5–95% RH
Automated Sample HandlingUp to 8 positions
Software Analysis MethodsSessile Drop, Tilting Plate, Pendant Drop, Oscillating Drop, Single-Fiber Mode
Surface Energy Calculation ModelsOwens-Wendt-Rabel, van Oss-Chaudhury-Good, Fowkes, Extended Fowkes, Wu, Zisman, Neumann
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelJF99A
PricingUpon Request
Measurement PrincipleWashburn Capillary Rise Method
Pressure Range0–330 mbar
Pressure Resolution0.16 mbar
Operating TemperatureAmbient
Quartz Tube DimensionsOD 10 mm
Instrument Dimensions295 × 240 × 260 mm
Power Supply220 V AC, 20 W
Optional AccessoryJYF08 Automated Powder Packing Station (programmable tapping cycles, real-time counter, uniform mechanical compaction)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelSCI-1100
Price RangeUSD 14,000–28,000
Instrument ClassHigh-Temperature Vacuum Contact Angle Measurement System
Form FactorBenchtop Laboratory System
Contact Angle Range0° < θ < 180°
Contact Angle Accuracy±1° (θ/2 method), ±0.1° (Circle Fitting Method)
Sample Stage DimensionsØ14 mm × 10 mm
Optical Magnification0.7–4.5×
Surface/Interfacial Tension Range0.01–1000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional OriginDomestic (PRC)
ModelJC2000Y
PricingAvailable Upon Request
Sample Stage100 × 70 mm manual XYZ platform with concentric stepped design for optical lenses
CameraUSB 2.0 industrial CCD, 700 TV lines, 25 fps
Optical Zoom0.7×–4.5× continuous zoom lens (with auxiliary magnification optics)
Image Resolution50–318 pixels/mm
Light SourceAdjustable monochromatic LED cold light
Temperature ControlOptional ambient-to-100 °C heated stage
Tilt CapabilityOptional ±15° sample oscillation stage
RotationOptional 360° vertical/horizontal rotation stages
SoftwareAutomated contact angle analysis (advancing/receding/rolling angles), surface energy calculation (Owens–Wendt two-liquid method), sessile drop, pendant drop, and curved-surface correction
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelDSA20
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelSCI-2000A
Price RangeUSD 2,800–7,200
Instrument ClassDynamic Contact Angle Analyzer
Form FactorBenchtop Laboratory System
Contact Angle Range0° < θ < 180°
Contact Angle Accuracy±1° (θ/2 method), ±0.1° (circle fitting)
Sample Stage Dimensions120 × 80 mm
Optical Magnification0.7×–5× continuous zoom
Surface/Interfacial Tension Range0.001–1000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m