Beifen Sanpu
Filter
Showing 331–360 of 450 results
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HW-19L |
| Temperature Range | Ambient to 105 °C |
| External Dimensions | 44 cm × 30 cm × 35 cm |
| Internal Chamber Dimensions | 38 cm × 18 cm × 25 cm |
| Interior Material | Anodized Aluminum |
| Heating Method | Five-Side Circulating Convection Heating |
| Power Supply | 220 V, 50 Hz or DC 12 V (vehicle-compatible) |
| Rated Power | 90–110 W |
| Net Weight | ≈ 5 kg |
| Insulation | Polyurethane Foam |
| Control Interface | Digital Keypad with One-Touch 100 °C Preset |
| Heating System Lifetime | ≥ 8,000 h Continuous Operation |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic Instrumentation |
| Model | HW-19L-1 |
| Power Supply | 220 V AC / 50 Hz or DC 12 V vehicle power |
| Heating Power | 90–110 W |
| Temperature Range | Ambient to 100 °C |
| Capacity | 19 L |
| Internal Dimensions | 38 × 18 × 25 cm |
| External Dimensions | 44 × 30 × 35 cm |
| Net Weight | ~5 kg |
| Heating System Lifetime | ≥8,000 h continuous operation |
| Construction | ABS exterior shell, aluminum inner chamber, polyurethane foam insulation |
| Heating Method | Five-sided circumferential convection heating |
| Control Interface | One-touch 100 °C preset + up/down digital temperature adjustment |
| Accessories | Integrated carrying handle and detachable shoulder strap] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | IAHS-20A Plus |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| Rinse Flow Rate | 0–100 mL/min (adjustable) |
| RSD | < 1.0% (measured with 100 ppm ethanol in water) |
| Interface | USB 2.0 |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 (software audit trail optional)] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | JAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Pressure Control | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–1800 s |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–1800 s |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB 2.0 |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 ready (with optional audit trail software module) |
| Brand | Beifen Sanpu |
|---|---|
| Model | JB-12 |
| Type | Dual-Deck Magnetic Stirrer |
| Power Supply | 220 V AC, 50 Hz |
| Motor Speed Range | 0–2400 rpm (infinitely variable) |
| Number of Stations | 12 (6 per deck, independently controllable) |
| Motor Power | 20 W × 12 stations |
| Heating Power | 150 W × 12 stations |
| Heating Performance | ~80 °C in 8 min for 100 mL water at 20 °C ambient |
| Construction | Cold-rolled steel housing with high-temperature epoxy powder coating |
| Compliance | CE-marked design principles |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JB-45 |
| Power Supply | 220 V ±10%, 50 Hz |
| Motor Power | 25 W |
| Heating Power | 400 W |
| Speed Range | 0–2600 rpm (infinitely variable) |
| Bidirectional Cycle | 60 s forward / 60 s reverse |
| Timer Range | 0–120 min |
| Temperature Control Range | Ambient to 100 °C (digital PID display) |
| Construction | Cold-rolled steel housing with high-temp epoxy powder coating |
| Included Accessories | One PTFE-coated stir bar, one stainless-steel temperature probe, support rod set, power cord |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | JF-2021B |
| Instrument Type | General-Purpose Gas Sampler |
| Configuration | Dual-Channel Air Sampler |
| Flow Range | 0.1–2.0 L/min |
| Maximum Vacuum Pressure | 60–120 kPa |
| Flow Stability | ±2.0% |
| Flowmeter Accuracy | ±2.0% |
| Service Life Under Max Flow & Backpressure | >5,000 h |
| Continuous Operation Time at Max Flow & Backpressure | >8 h |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JF-2040 |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Air Sampler |
| Instrument Configuration | Quad-Channel Gas Sampler |
| Flow Range | 0.1–2.0 L/min |
| Maximum Vacuum Pressure | 70–130 kPa |
| Flow Stability | ±2.0% |
| Flowmeter Accuracy | ±2.0% |
| Service Life Under Max Flow & Backpressure | >5,000 h |
| Continuous Operation Time at Max Flow & Backpressure | >8 h |
| Delay Time Range | 1 min–99 h 59 min |
| Sampling Time Range | 1 min–99 h 59 min |
| Interval Time Range | 1 min–99 h 59 min |
| Programmable Sampling Cycles | 1–99 |
| Pre-Filter Pressure Range | −20–0 kPa |
| Ambient Pressure Range | 70–130 kPa |
| Temperature Control Range | 15–30 °C |
| Operating Temperature Range | −30 to +50 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Internal Li-ion Battery | 8.4 V / 15 Ah |
| Battery Runtime | >15 h |
| Noise Level | <55 dB(A) |
| Dimensions | 330 × 280 × 230 mm |
| Weight | ~5.2 kg |
| Brand | Beifen Sanpu |
|---|---|
| Model | KAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C on request), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C), ±0.5 °C stability |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-electronic pressure control (optional) |
| Rinse Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB communication with PC |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beifen Sanpu |
|---|---|
| Model | KS-1 |
| Standard Compliance | GB/T 3536, ASTM D92 |
| Flash Point Range | Ambient to 400 °C |
| Repeatability | ±2 °C (≤150 °C), ±4 °C (>150 °C) |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 400 W |
| Temperature Control | Solid-State Voltage Regulator (Continuous Ramp) |
| Dimensions (W×D×H) | 285 × 185 × 350 mm |
| Net Weight | 7 kg |
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KS100 |
| Compliance | GB/T 267–1988, GB/T 3536–2008, GB/T 1671–2008, ASTM D92 |
| Measurement Range | Ambient to 400 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤3 °C |
| Temperature Resolution | 0.1 °C |
| Sensor | Imported Class A PT100 Platinum Resistance Thermometer |
| Ignition Detection | Ionization Ring Sensor |
| Power Supply | AC 220 V ±20%, 50 Hz ±10% |
| Rated Power | 400 W |
| Dimensions | 440 × 280 × 290 mm |
| Weight | 18 kg |
| Operating Environment | 0–40 °C, ≤85% RH |
| Control Interface | Capacitive Touchscreen with Screen Protection |
| Data Storage | 255 Test Records with Timestamps |
| Heating Control | Adaptive PID Algorithm per Standard Protocols |
| Atmospheric Compensation | Integrated Barometric Sensor with Auto-Calibration |
| Ignition Options | Selectable Electronic Spark or Gas Flame Ignition |
| Multi-Furnace Capability | Single Host Controls Multiple Independent Test Furnaces |
| Automation Level | Full Cycle Automation (Heating, Lid Opening, Ignition, Flash Detection, Alarm, Cooling, Reporting) |
| Built-in Thermal Printer | High-Speed, Dot-Matrix, Offline Printing Support |
| Self-Diagnostic System | Real-Time Sensor Health Monitoring and Over-Temperature Safeguard |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KX-DB |
| Price | Upon Request |
| Power Supply | 220 V ±10%, 50 Hz |
| Heating Supply | 12 V ±10%, 50 Hz |
| Heating Power | 8 W |
| Temperature Range | Ambient to 50 °C |
| Temperature Control Accuracy | ±1 °C |
| Stage Dimensions | 98 × 60 × 6 mm |
| Center Aperture Diameter | Φ15 mm |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LAHS-20A Plus |
| Sample Positions | 20 |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (customizable: 0.5/2/5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50/100 mL) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Pressurization Time | 0–999 s |
| Purge/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Interface | USB |
| Sample Path Materials | Deactivated fused-silica and high-inertness stainless-steel tubing |
| Valve Configuration | Heated 6-port switching valve with integrated quantitative loop] |
| Brand | Beifen Sanpu |
|---|---|
| Model | LC-3000 |
| Pump Type | Dual-plunger reciprocating high-pressure solvent delivery system |
| Detector | UV-Vis (190–700 nm) with deuterium/tungsten lamp source |
| Flow Rate Range (Analytical) | 0.001–9.999 mL/min |
| Flow Precision | RSD ≤ 0.5% at 1 mL/min |
| Flow Repeatability | RSD ≤ 0.1% at 1 mL/min |
| Max Pressure (Analytical, stainless steel) | 42 MPa |
| Max Pressure (Analytical, PEEK) | 30 MPa |
| Baseline Noise | ≤1.5 × 10⁻⁵ AU/h (254 nm, MeOH/H₂O 80/20, 1 mL/min) |
| Baseline Drift | ≤4 × 10⁻⁴ AU/h (254 nm, MeOH/H₂O 80/20, 1 mL/min) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Data Interface | RS-232 serial control + direct analog/digital signal output to PC |
| Software | GLP-compliant intelligent remote-control chromatography workstation with audit trail capability |
| System Architecture | Modular, field-upgradable from isocratic to binary or quaternary gradient configuration |
| Biocompatibility Option | PEEK pump heads and fluidic path components available |
| Dimensions (Pump/Detector) | 398 × 149 × 267 mm |
| Weight | 10 kg per module |
| Power | 220 V ±10%, 50 Hz, 40 W |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LH-10 |
| Temperature Control Range | Ambient to 450 °C |
| Gas Flow Rate | 0–200 mL/min |
| Tube Capacity | 10 tubes |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <200 VA |
| Temperature Accuracy | ±1 °C |
| Maximum Aging Duration | >999 h |
| Simulated Sampling Time | 0–99 min |
| Flow Adjustment Range | 0–1000 mL/min |
| Tube Dimensions (Standard) | Ø6 mm × ≥110 mm |
| Dimensions (H×W×D) | 225 × 265 × 345 mm |
| Net Weight | ~10.5 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LH-10A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–1000 mL/min |
| Tube Capacity | 10 tubes |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LH-24A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–500 mL/min (expandable to 0–1000 mL/min per specification) |
| Tube Capacity | 24 adsorption tubes |
| Control Accuracy | ±1 °C |
| Max Aging Duration | >999 h |
| Dimensions (H×W×D) | 350 mm × 230 mm × 330 mm |
| Net Weight | ~12 kg |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <200 VA |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LH-24B |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–1000 mL/min |
| Tube Capacity | 24 tubes |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <200 VA |
| Temperature Accuracy | ±1 °C |
| Maximum Aging Duration | >999 h |
| Simulated Sampling Time | 0–99 min |
| Tube Dimensions (Standard) | Ø6 mm × ≥110 mm or 1/4″ OD × ≥3.5″ |
| Dimensions (H×W×D) | 350 × 230 × 330 mm |
| Net Weight | ~12 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | MAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Valve & Transfer Line Heating | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow (Purge/Backflush) | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB communication with PC |
| Valve Configuration | High-inertness 6-port valve with heated connection points |
| Tubing Material | Deactivated fused-silica or SilcoNert®-treated stainless steel |
| Power Supply | 220 V AC, 50 Hz |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory Instrument |
| Model | Multi-2025 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Target Analytes | Methylmercury (CH₃Hg⁺), Ethylmercury (C₂H₅Hg⁺) |
| Detection Principle | Purge-and-Trap Coupled with Gas Chromatography–Cold Vapor Atomic Fluorescence Spectrometry (PT-GC-CVAFS) |
| Regulatory Compliance | HJ 977–2018, HJ 1269–2022, HJ 1268–2022, SNT 5517–2023 |
| Elemental Capability | As, Hg, Pb, Se, Sb, Bi, Cd, Te, Sn, Ge, Zn, Au (12 elements via hydride generation-AFS) |
| Column | Modified OV-3 packed column |
| Pyrolysis Temperature | Up to 1050 °C |
| Software | Graphical GUI with real-time status monitoring, consumables lifetime tracking, and multi-format reporting (PDF/Excel/Word) |
| Data Integrity Features | Audit trail support, user access control, instrument state logging |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Detection Principle | Purge-and-Trap / Gas Chromatography–Cold Vapor Atomic Fluorescence Spectrometry (GC-CVAFS) |
| Compatible With | Commercial Purge-and-Trap Concentrators |
| GC Column | Modified OV-3 Packed Column |
| Pyrolysis Temperature | Up to 1050 °C |
| Detection Elements | As, Hg, Pb, Se, Sb, Bi, Cd (12 total) |
| Regulatory Compliance | HJ 977–2018, HJ 1269–2022, HJ 1268–2022, SNT 5517–2023 |
| Software | Graphical Interface with Real-Time Status Monitoring, Consumable Lifetime Tracking, Multi-Format Reporting (Word/Excel/PDF) |
| Application Scope | Environmental water, soil, sediment, biological tissues, cosmetics, herbal medicine, feed, and seafood matrices |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | Multi-2025 |
| Price | USD 28,000 (approx.) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Multi-2025 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Targets | Methylmercury (CH₃Hg⁺), Ethylmercury (C₂H₅Hg⁺), Total Mercury, Arsenic, Selenium, Antimony, Lead, Bismuth, Cadmium, etc. (12 elements) |
| Compliance | HJ 977–2018, HJ 1269–2022, HJ 1268–2022, SNT 5517–2023 |
| Detection Principle | Purge-and-Trap Coupled with Gas Chromatography–Cold Vapor Atomic Fluorescence Spectrometry (PT-GC-CVAFS) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Multi-2025 |
| Instrument Type | Laboratory-Based Water Quality Analyzer |
| Target Analytes | Methylmercury (CH₃Hg⁺), Ethylmercury (C₂H₅Hg⁺) |
| Detection Principle | Purge-and-Trap Coupled with Gas Chromatography–Cold Vapor Atomic Fluorescence Spectrometry (PT-GC-CVAFS) |
| Compliant Standards | HJ 977–2018, HJ 1269–2022, HJ 1268–2022, SNT 5517–2023 |
| Sample Compatibility | Aqueous matrices (surface water, wastewater, drinking water), soil extracts, sediment pore water, biological tissues (e.g., fish muscle, blood), agricultural products, cosmetics, traditional Chinese medicinal materials |
| Elemental Coverage | As, Hg, Pb, Se, Sb, Bi, Cd, Te, Sn, Ge, Zn, Cu (12 elements via hydride generation atomic fluorescence) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Detection Principle | Purge-and-Trap / Gas Chromatography–Cold Vapor Atomic Fluorescence Spectrometry (PT-GC-CVAFS) |
| Application Domain | Environmental Monitoring |
| Compliance | HJ 977–2018, HJ 1269–2022, HJ 1268–2022, SNT 5517–2023 |
| Sample Compatibility | Aqueous, Soil, Sediment, Biological Tissues, Food & Feed Matrices |
| Column Configuration | Modified OV-3 Packed Column |
| Thermal Decomposition Module | Up to 1050 °C |
| Integrated Hydride Generation Module | 3D-Printed Monolithic Reactor |
| Elemental Coverage | As, Hg, Pb, Se, Sb, Bi, Cd, Te, Sn, Ge, Zn, Au (12 elements) |
| Software | Graphical GUI with Real-Time System Status Monitoring, Consumables Lifetime Tracking, and Multi-Format Reporting (PDF/Excel/Word) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Beifen Sanpu Instrument Co., Ltd. |
| Type | Volumetric Flow Calibrator |
| Model | MZ-103A |
| Measurement Principle | Soap Film Transit Time |
| Flow Range | 2 mL/min to 2 L/min |
| Accuracy | ±1% of reading |
| Repeatability | <0.5% |
| Time Resolution | 0.01 s (displayed as 0.1 s) |
| Volume Measurement | Fixed calibrated glass tube |
| Operating Temperature | 0–40 °C |
| Power | Rechargeable 4.8 V / 700 mAh battery (standby >24 h) or external 9 V DC input |
| Dimensions | 90 mm × 150 mm × 280 mm |
| Compliance | Designed for field calibration per ISO 6145-4 and ASTM D6196 Annex A2 |
| Brand | Beifen Sanpu |
|---|---|
| Model | NAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Carrier Gas Flow Control | EPC-electronic pressure control (optional) |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | Compatible with ASTM D6866, ISO 11843-2, USP <467>, and FDA 21 CFR Part 11–compliant data handling when integrated with validated GC software |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 10–2×10⁶ mPa·s |
| Rotors | #1–#4 (standard), #0 optional |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±2% for Newtonian fluids |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–35 °C, RH ≤80% |
| Dimensions | 370 × 325 × 280 mm |
| Weight | 6.8 kg] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | OAHS-20A Plus |
| Sample Positions | 20 |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow (Purge) | 0–100 mL/min (adjustable) |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Interface | USB |
| Valve Type | High-inertness 6-port rotary valve with heated connection point |
| Tubing | Deactivated fused-silica or SilcoNert®-treated stainless steel |
| Automation Level | Full sequence execution (equilibration, pressurization, sampling, injection, purge, vial indexing)] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | P3T-80A |
| Sample Capacity | 80 positions (40 mL VOA vials) |
| Injection Precision | RSD ≤ 3% |
| Trap Temperature Range | Ambient to 380 °C |
| Cooling | 250 °C → 35 °C in ≤ 90 s |
| Purge Heater Temperature | Ambient to 95 °C |
| Sample Chilling | Ambient only |
| Cold Trap Temperature | −40 °C to ambient (Peltier + air cooling, no liquid nitrogen required) |
| Transfer Line & Valve Heating | Ambient to 220 °C |
| Water Removal Trap | Ambient to 400 °C |
| Wash Water Temperature | Ambient to 90 °C |
| Solid Sample Heating | Ambient to 100 °C |
| Purge Flow Rate | 0–150 mL/min |
| Timing Resolution | 0.1 s–100 min |
| Timing Accuracy | < 0.1 s |
| Max System Pressure | ≤ 0.6 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 800 W |
| Dimensions | 750 × 500 × 550 mm |
| Weight | ~50 kg |