Beifen Sanpu
Filter
Showing 241–270 of 450 results
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | G11C-9860 |
| Temperature Control Range | 100–350 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific Fatty Acid Profiling |
| Compliance | GB/T 17376–2008 & GB/T 17377–2008 |
| Detector | FID with Auto-Ignition |
| Column Compatibility | FFAP Capillary Column (30 m × 0.32 mm) |
| Temperature Control | 10-zone, ±0.1–0.2 °C accuracy, up to 450 °C |
| Programmed Heating | 16-step, 0.1–40 °C/min ramp rate |
| Data System | Built-in GC control and acquisition software with valve timing control |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (up to 300 °C optional) |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB |
| Display | 7-inch TFT LCD with Chinese UI (English firmware available upon request) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-2010 |
| Temperature Control Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Temperature Accuracy | ±0.1 °C (≤200 °C), ±0.2 °C (>200 °C) |
| Programmed Temperature Ramping | 8-step linear |
| Minimum Temp Increment | 0.1 °C |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GC-2010 |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 5 °C above ambient to 400 °C |
| Max. Oven Ramp Rate | 40 °C/min |
| Cooling Rate | 320 °C/min (with intelligent back-door system) |
| Carrier Gas Flow Range & Control | 0–856 mL/min |
| Carrier Gas Pressure Range & Control | 0–621 psi |
| Injector Max. Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–532 psi |
| Total Injector Flow Setting Range | 0–452 mL/min |
| Detection System | FID with optimized hydrocarbon response |
| Column Configuration | 50 m × 0.53 mm ID × 0.25 µm PLOT capillary column |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | Ambient to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | 400°C to 50°C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–800 kPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–800 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | Ambient to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 400 °C → 50 °C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–800 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–800 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | Up to 420 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate | 420 °C → 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–999 mL/min |
| Carrier Gas Pressure Range & Control | 0–990 kPa |
| Injector Temperature | Up to 420 °C |
| Injector Pressure Setting Range | 0–990 kPa |
| Total Injector Flow Setting Range | 0–999 mL/min |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Forensic Alcohol Testing & Clinical Toxicology |
| Temperature Control Range | 295 °C |
| Maximum Ramp Rate | 26 °C/min |
| Cooling Rate | 374 °C/min |
| Carrier Gas Flow Range & Control | 0–487 mL/min |
| Carrier Gas Pressure Range & Control | 0–472 kPa |
| Injector Maximum Operating Temperature | 276 °C |
| Injector Pressure Setting Range | 0–492 kPa |
| Total Injector Flow Setting Range | 0–560 mL/min] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory GC |
| Model | GC-2010F |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose / Forensic Toxicology |
| Oven Temperature Range | 420 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cool-down Time | ~8 min (from 420 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–600 kPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–600 kPa |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-2011A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | 400 °C → 50 °C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–800 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–800 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Model | GC-3420A |
| Price Range | USD 4,200 – 7,000 |
| Application Field | General-purpose Environmental Air Monitoring |
| Temperature Control Range | Ambient to 400 °C |
| Ramp Rate | Up to 40 °C/min |
| Cooling Rate | Forced air cooling, <5 min from 300 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–100 mL/min (N₂, H₂, He), electronic pressure/flow control (EPC) |
| Inlet Pressure Range | 0–100 psi |
| Maximum Inlet Temperature | 450 °C |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 5°C above ambient to 380°C |
| Programmable Temperature Ramping | 32 Steps / 33 Platforms |
| Detector Options | FID, TCD, ECD, FPD, NPD, PDHID (selectable up to 3 simultaneously) |
| EPC Control | 6th-Generation Electronic Pressure Control |
| Data Interface | 10/100M Adaptive Ethernet, RS-232, Bluetooth 5.0 |
| Column Oven Cooling/Heating Rate | Optimized via Inverter-Driven Air Circulation System |
| Software Platform | DOTHUNET Workstation (supports up to 300 instruments, Modbus/TCP server, LIMS/DCS integration) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC-8890A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food & Pharmaceutical Packaging Quality Control |
| Oven Temperature Range | Up to 450 °C |
| Maximum Ramp Rate | 80 °C/min |
| Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 sccm |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–1200 sccm |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | GC-9790plus |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Alcohol Analysis |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Focus | Environmental Monitoring |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860 |
| Temperature Control Range | 100–350 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Detector | Hydrogen Flame Ionization Detector (FID) |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Model | GC-9860 |
| Temperature Control Range | 100–350 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time (350→100 °C) | ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860 |
| Temperature Control Range | 100–350 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time (350 → 100 °C) | ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Application Field | Food Industry-Specific Analysis |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860 |
| Price Range | USD 7,000–14,000 |
| Application Scope | Universal (Optimized for LPG & DME) |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | GC-9860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring (Drinking Water Compliance) |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable GC System |
| Detection Principle | Flame Ionization Detection (FID) with Dual-Packed Column Configuration (Total Hydrocarbons Column + Methane-Specific Column) |
| Compliance Standards | HJ 38–2017, HJ 604–2017 |
| Temperature Control Range | Ambient +5°C to 400°C |
| Temperature Accuracy | ±0.1°C |
| Programmed Temperature Ramping | 6-Stage |
| Dimensions | 555 × 525 × 485 mm |
| Weight | ~52 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GC-9860 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | Universal (Environmental, Petrochemical, Pharmaceutical, Food & Safety, Public Health, Research) |
| Oven Temperature Range | +5 °C to 450 °C |
| Temperature Programming | 8-step linear ramp |
| 升温 Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cooling Rate | 450 °C → 50 °C (with dual rear doors) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Compatibility | Packed columns (3–5 mm OD), Capillary columns (standard 6-inch mounting span) |
| Detector Capacity | Up to 4 detectors simultaneously (e.g., dual FID, dual TCD, dual ECD, or mixed configurations) |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (γ-BHC) |
| Data Storage | 20 method/data sets on internal FLASH memory |
| Display | 5.7″ LCD (320×240), bilingual Chinese/English interface |
| Brand | Beifen Sanpu |
|---|---|
| Model | GC-9860 |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Focus | Environmental Analysis |
| Temperature Control Range | Ambient ±8 °C to 450 °C (1 °C increment) |
| Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Oven Cooling | Motor-driven rear door with intelligent stepper control |
| Detector Compatibility | FID, TCD, ECD, FPD, Ni-converter furnace |
| Inlet Configurations | Two independent inlets + one valve inlet |
| Autosampler Ready | Compatible with multi-position liquid autosamplers, headspace samplers, and thermal desorbers |
| Data System | Embedded bidirectional control software with valve timing control (e.g., 6-port, 10-port) |
| Pressure Protection | Automatic power cutoff at carrier gas pressure <0.1 MPa |
| Power | 220 V, 50 Hz, 2000 W |
| Dimensions | 59 × 48 × 49 cm |
| Weight | 40 kg |
| Temperature Zones | 10 independently controlled zones |
| Programmed Temperature | 16-step ramping |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860 |
| Temperature Control Range | 100–350 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | GC-9860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Baijiu (Chinese Spirit) Chromatographic Analysis |
| Oven Temperature Range | 100–350 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Air Monitoring |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Max Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Air Quality Monitoring |
| Oven Temperature Range | 4 °C above ambient to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C in ≤8 min |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–450 psi |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–500 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Detection | Dual FID (Flame Ionization Detectors) |
| Column Compatibility | Packed & Capillary (including 50 m × 0.32 mm × 1 µm TVOC-specific column and 2 m × 3 mm benzene-packed column) |
| Included Accessories | ATDS-3420 Thermal Desorber, BF-300E H₂ Generator (99.999%, 0–300 mL/min), BF-2L Zero-Air Generator (oil-free, 0–2000 mL/min), HL-10 Tube Aging Unit, ZM-102B Electronic Soap Film Flowmeter, Tenax-TA & Activated Carbon Sampling Tubes (6 mm), Certified TVOC & Benzene Standard Solutions (10/100/1000 µg/mL)] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Safety Testing |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time (350→100 °C) | ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |