CLEAN
Filter
Showing all 28 results
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | CON200 |
| Portability | Portable |
| Conductivity Range | 0.000 µS/cm to 400.0 mS/cm |
| TDS Range | 0.000 mg/L to 400.0 g/L |
| Resistivity Range | 0 to 100.0 MΩ·cm |
| Salinity Range | 0.0 to 260.0 g/L |
| Temperature Range | −10.0 °C to 110.0 °C |
| Accuracy | ±0.5% of Full Scale |
| Resolution | 0.001 µS/cm to 0.1 mS/cm |
| Display | 65 × 40 mm backlit LCD |
| Protection Rating | IP67 |
| Data Storage | 50 readings |
| Power | Two AAA batteries (≥500 h lifetime) |
| Operating Environment | −5 °C to 60 °C, <90% RH |
| Dimensions | 94 × 190 × 35 mm (W × L × H) |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | CON500 |
| Form Factor | Benchtop |
| Conductivity Range | 0.000 µS/cm to 400.0 mS/cm |
| TDS Range | 0.000 mg/L to 400.0 g/L |
| Resistivity Range | 0 to 100.0 MΩ·cm |
| Salinity Range | 0.0 to 260.0 g/L |
| Temperature Range | −10.0 °C to 110.0 °C |
| Accuracy | ±0.5% F.S. |
| Minimum Resolution | 0.001 µS/cm |
| Data Storage | 50 sets |
| Auto Power-Off | 10 min (configurable) |
| IP Rating | IP65 |
| Operating Environment | −5 °C to 60 °C, <90% RH |
| Dimensions (W×L×H) | 140 × 210 × 35 mm |
| Weight | 650 g |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Model | CS1728D |
| pH Range | 0–12 |
| Zero Point | 7.00 ± 0.25 |
| Resolution | 0.01 pH |
| Temperature Range | 0–80 °C |
| Max Pressure | 10 bar |
| Body Material | PPS/PP |
| Sensing Membrane | W28 hemispherical glass |
| Membrane Resistance | < 500 MΩ |
| Reference System | SNEX Ag/AgCl/KCl solid-state double-junction |
| Liquid Junction | SNEX dual-salt bridge |
| Threaded Connection | NPT 3/4" |
| Cable Length | 5 m |
| Output Interface | RS-485 Modbus RTU |
| Supply Voltage | DC 12 V |
| IP Rating | IP68 |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Model | CS1768 |
| pH Range | 0–14 |
| Temp. Range | 0–90 °C |
| Max. Pressure | 20 bar (@50 °C) |
| Junction Type | SNEX Solid-State Ag/AgCl/KCl |
| Housing Material | PPS or PA+GF |
| Temperature Sensor | Pt1000 (standard), Pt100 / NTC10K (optional) |
| Thread | NPT 3/4" or PG13.5 |
| Cable | 5 m coaxial with BNC connector |
| Sensitive Bulb Type | B11 |
| Output Compatibility | Designed for CLEAN PH3000 transmitter |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Model | CS1768-hp |
| Pressure Rating | 0–20 bar (@ 50 °C) |
| pH Range | 0–14 |
| Temperature Range | 0–90 °C |
| Liquid Junction | SNEX Solid-State Ag/AgCl/KCl Reference System |
| Housing Material | PPS (Polyphenylene Sulfide) |
| Thread | NPT 3/4″ (wet end & dry end) |
| Cable | 5 m coaxial with BNC connector |
| Temperature Sensor Options | Pt1000 / Pt100 / NTC10K |
| Output | 4–20 mA (pH/ORP + temperature, two-wire, passive) |
| IP Rating | IP65 |
| Compliance | Designed for continuous industrial process monitoring per IEC 61508 functional safety principles (SIL2-capable when integrated with certified controllers) |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | CS1778 |
| Instrument Type | Inline/Process pH Electrode |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Calibration Standard | NIST-traceable USA buffer solutions (pH 4.01, 7.00, 10.01) |
| Operating Temperature | 0–90 °C |
| Max Pressure | 20 bar (@ 50 °C) |
| Body Material | Polyphenylsulfone (PPS) |
| Reference System | SNEX Ag/AgCl/KCl solid-state junction |
| Liquid Junction | Solid-State Junction (SSJ), non-porous, ion-exchange-free |
| Temperature Sensor | Integrated Pt1000 RTD |
| Process Connection | NPT 3/4" |
| Cable | 5 m coaxial, BNC termination |
| pH Sensing Element | Chemically resistant, abrasion-resistant glass membrane |
| Brand | CLEAN |
|---|---|
| Model | CS1778D |
| Output | RS-485 (Modbus RTU) |
| pH Range | 0–14 |
| Temp. Range | 0–90 °C |
| Max. Pressure | 20 bar @ 50 °C |
| Housing | PPS |
| Thread | NPT 3/4″ |
| Liquid Junction | SNEX solid-state electrolyte membrane |
| Reference System | SNEX Ag/AgCl/KCl |
| Sensing Membrane | B11 glass |
| Temperature Sensor | Pt1000 / Pt100 / NTC10K (field-selectable) |
| Cable | 5 m coaxial, BNC termination |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Model | CS1788 |
| pH Range | 0–14 |
| Temperature Range | 0–90 °C |
| Pressure Rating | 0–20 bar (@50 °C) |
| Reference System | SNEX Ag/AgCl/KCl |
| Liquid Junction | SNEX solid-state membrane with dual ceramic pores |
| Sensing Bulb | W02 low-ionic-strength optimized glass |
| Body Material | PPS (polyphenylsulfone) |
| Thread | NPT 3/4" |
| Cable | 5 m coaxial, BNC connector |
| Temperature Sensor Options | Pt1000 / Pt100 / NTC10K |
| Output | 4–20 mA (pH/ORP & temperature, 2-wire, passive) |
| Accuracy | ±0.01 pH / ±1 mV / ±0.3 °C |
| Input Impedance | ≥10¹² Ω |
| Protection Rating | IP65 |
| Mounting | Panel-mount with dual clamp fixation |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Model | CS3523D |
| Detection Parameter | Conductivity (single-parameter) |
| Form Factor | Pen-type |
| Conductivity Range | 0.00–20.00 µS/cm |
| TDS Range | 0–10.00 ppm |
| Resistivity Range | 0–10.00 MΩ·cm (inferred from low-conductivity context) |
| Salinity Range | 0.0–260.0 g/L |
| Temperature Range | −10.0–110.0 °C |
| Accuracy | ±0.5% FS |
| Minimum Resolution | 0.01 µS/cm |
| Electrode Constant | K = 0.01 cm⁻¹ |
| Reference Temperature | 15.0–35.0 °C |
| Temperature Coefficient | 0.00–10.00 %/°C |
| TDS Factor | 0.40–1.00 |
| Pressure Rating | 0 to −8 bar (vacuum-rated) |
| Housing Material | Polypropylene (PP) |
| Wetted Parts | Glass body, platinum electrodes |
| Connection | NPT 3/4″ |
| Cable Length | 5 m |
| Interface | RS-485 Modbus RTU |
| Power Supply | DC 12 V |
| Output Signals | Conductivity, TDS, Temperature |
| Ingress Protection | IP68 |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CS4751D |
| Instrument Type | Online |
| Measurement Principle | Electrochemical (Clark-type Polarographic Probe) |
| Range | 0.0–400.0% saturation, 0.00–40.00 mg/L |
| Accuracy | ±0.2% FS |
| Repeatability | 0.1% / 0.01 mg/L |
| Detection Limit | ±2 ppb (zero point) |
| Temperature Range (Operating) | 0–60 °C |
| Temperature Measurement Range | −10.0–110.0 °C |
| Temp. Resolution | 0.1 °C |
| Salinity Compensation | 0.0–50.0 ppt |
| Pressure Compensation | 600–2000 mbar |
| Response Time (t₉₅) | <60 s at 25 °C |
| Stabilization Time | 15–20 min |
| Zero Drift | <0.5% FS |
| Housing Material | PPS/PP |
| Electrode Cap Thread | NPT 3/4″ |
| Cable Length | 5 m |
| Connector | Open-terminal block |
| Communication Interface | RS-485 |
| Protocol | Modbus RTU |
| Power Supply | DC 12 V |
| Output Signals | DO concentration (mg/L and % sat), temperature |
| IP Rating | IP68 |
| Minimum Flow Rate | >0.03 m/s |
| Residual Current | <2% in air |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Model | CS5530D |
| Instrument Type | Online |
| Measurement Principle | Amperometric Electrochemical Sensor |
| Measured Parameter | Free Chlorine (Residual Cl₂) |
| Range | 0–2.000 mg/L and 0–20.00 mg/L |
| Accuracy | ≤3% of reading |
| Repeatability | ±0.02 mg/L |
| Resolution | 0.001 mg/L (low range), 0.01 mg/L (high range) |
| LOD | 0.035 mg/L |
| Temperature Compensation | Integrated Pt1000 RTD |
| pH Compensation | Built-in pH input interface for external pH electrode integration |
| Operating Temperature | 0–80 °C |
| Max Pressure | 10 bar |
| Housing Material | Glass sensing element + PP + POM |
| Reference System | Dual-salt-bridge Ag/AgCl |
| Junction Type | Annular ceramic liquid junction |
| Cap Material | PP |
| Connector | PG13.5 |
| Handle Material | POM |
| Cable Length | 5 m |
| Communication | RS-485 Modbus RTU |
| Power Supply | DC 12 V |
| Output Signals | Residual chlorine concentration (mg/L), temperature (°C) |
| Enclosure Rating | IP68 |
| Compatible Flow Cell | A580 hermetically sealed flow-through cell |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Model | CS6510Cl |
| Instrument Type | Online ISE Sensor |
| Measurement Range | 0–99,999 mg/L (ppm) Cl⁻ |
| Detection Limits | 0.01 / 0.1 / 1 mg/L (ppm) |
| Response Time | 30 s (to 95% signal stability) |
| Accuracy | ±2.5% of reading |
| Operating Temperature | 0–50 °C |
| Output Interface | BNC |
| Body Material | Glass |
| Dimensions | Ø12 × 110 mm |
| Reference System | Double-junction Ag/AgCl with annular ceramic frit |
| Interferents | S²⁻, I⁻, CN⁻, Br⁻ |
| pH Range | 2–12 |
| Input Impedance | <1 MΩ |
| Temperature Compensation | Not recommended for direct electrode compensation |
| Storage | Long-term—dry |
| Electrode Slope | 56 ± 3 mV/decade at 25 °C |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Model | CS6510F |
| Instrument Type | Online ISE Probe |
| Measurement Range | 0–99,999 mg/L (ppm) F⁻ |
| Detection Limits | 0.01 / 0.1 / 1 mg/L (ppm) |
| Response Time | 30 s (to 95% signal stability) |
| Accuracy | ±2.5% of reading |
| Operating Temperature | 0–50 °C |
| pH Range | 5–8 |
| Temperature Compensation | Integrated |
| Reference Electrode | Double-junction, annular ceramic junction |
| Body Material | Glass |
| Dimensions | Ø12 × 110 mm |
| Connector | BNC |
| Pressure Rating | 0–70 psi |
| Interface Compatibility | Compatible with pH meters, ion meters, and online ion analyzers (e.g., ION5000 series) |
| Interferences | Al³⁺, Fe³⁺ (requires masking agents or pH control) |
| Storage | Long-term—dry |
| Electrode Slope | 57 ± 2 mV/decade at 25 °C |
| Input Impedance | 100–200 kΩ |
| Equivalence Point | 20 ppm F⁻ (for potentiometric titration support) |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | CS6510NH4 |
| Instrument Type | Online ISE |
| Measurement Range | 0–99,999 mg/L (ppm) NH₄⁺ |
| Detection Limit | 0–99,999 mg/L (ppm) NH₄⁺ |
| Response Time | ≤30 s to 95% of final value |
| Accuracy | ±2.5% of reading |
| Operating Temperature Range | –10 °C to +150 °C |
| pH Range for Measurement | 4–10 |
| Reference Electrode | Dual-salt-bridge with annular ceramic junction |
| Body Material | Glass |
| Dimensions | Ø12 × 110 mm |
| Cable Length | 1 m |
| Connector | BNC |
| Output Impedance | ≥100 MΩ |
| Temperature Compensation | Integrated |
| Pressure Rating | Not specified |
| Interference | K⁺ (significant), other monovalent cations (moderate) |
| Storage | Long-term — dry |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CS6710Ca |
| Instrument Type | Online-Ready ISE |
| Measurement Range | 0.1–18,000 ppm NH₄⁺ |
| Detection Limit | 0.1 ppm NH₄⁺ |
| Response Time | ≤30 s to 95% of final signal |
| Output Sensitivity | 55 ± 3 mV/decade |
| Operating Temperature | 0–50 °C |
| pH Range for Measurement | 4–10 |
| Input Impedance | 20–50 MΩ |
| Reference System | Double-junction Ag/AgCl with single-pore ceramic junction |
| Body Material | PMMA + PVC |
| Threaded Connection | PG13.5 / NPT 3/4″ |
| Cable Length | 5 m |
| Pressure Rating | 0–2 atm |
| Temperature Compensation Options | 10 kΩ, 22 kΩ, PT100, or PT1000 thermistors |
| Zero Point Calibration | 10 ppm NH₄⁺ isopotential point |
| Interference | K⁺ (significant), Na⁺ (minor), Ca²⁺/Mg²⁺ (negligible at pH 4–10) |
| Storage | Long-term — dry |
| Compatible Instruments | Benchtop ion meters, pH/mV meters with millivolt input, and OEM online ammonia analyzers |
| [Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Model | DH200 |
| Measurement Range (H₂) | 0.000–2.000 ppm (0–2000 ppb) |
| Resolution | 0.001 ppm |
| Accuracy | ±0.002 ppm |
| ORP Range | −2000 to +2000 mV |
| Power | 2 × AAA batteries |
| Operating Temp | −5 °C to 60 °C |
| Dimensions | 94 × 190 × 35 mm (W×L×H) |
| Weight | 250 g] |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China Market Distribution) |
| Model | DH30 |
| Price | USD 285 (FOB) |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | DO200 |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| DO Range | 0.00–40.00 mg/L |
| Saturation Range | 0.0–400.0% |
| DO Resolution | 0.01 mg/L |
| Saturation Resolution | 0.1% |
| DO Accuracy | ±0.2% F.S. |
| Temperature Range | 0.0–50.0 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Atmospheric Pressure Setting | 600–1400 mbar (1 mbar step) |
| Salinity Setting | 0.0–40.0 g/L (0.1 g/L step) |
| Data Storage | 50 sets |
| IP Rating | IP67 |
| Dimensions | 94 × 190 × 35 mm (W × L × H) |
| Power | 2 × AAA batteries (>500 hrs operation) |
| Operating Environment | −5 to 60 °C, <90% RH |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | DO30 |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Measurement Range | 0.00–40.00 mg/L (ppm) and 0.0–200.0% saturation |
| Accuracy | ±2% of full scale |
| Resolution | 0.01 mg/L, 0.1% saturation |
| Temperature Range | 0–100.0 °C (32–212 °F) |
| Temperature Compensation | Automatic (0–60 °C) |
| Salinity Compensation | 0.0–40.0 ppt |
| Atmospheric Pressure Compensation | 600–1100 mbar |
| Calibration | 1- or 2-point (zero-oxygen solution or air-saturated water) |
| Display | Multi-line LCD (21 × 34 mm), backlight enabled |
| IP Rating | IP67 |
| Power | 1 × 1.5 V AAA battery |
| Dimensions (H×W×D) | 185 × 40 × 48 mm |
| Weight | 95 g |
| Auto-off | 5 minutes of inactivity |
| Electrode Replaceability | User-serviceable galvanic probe with replaceable membrane cap (CS49303H1L) |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | DO500 |
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Measurement Range (DO) | 0.00–40.00 mg/L |
| Accuracy | ±0.2% F.S. |
| Repeatability | 0.1% |
| Detection Limit | 0 mg/L |
| Saturation Range | 0.0–400.0% |
| Temperature Compensation Range | 0.0–50.0 °C |
| Temp. Accuracy | ±0.2 °C |
| Atmospheric Pressure Setting | 600–1400 mbar (1 mbar resolution) |
| Salinity Compensation | 0.0–40.0 g/L (0.1 g/L resolution) |
| Data Storage | 50 sets |
| Dimensions | 140 × 210 × 35 mm (W × L × H) |
| Weight | 650 g |
| Operating Environment | –5 to 60 °C, <90% RH |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | DOZ30 |
| Measurement Principle | Three-Electrode Amperometric |
| Range | 0–10.00 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±1% F.S. |
| Temperature Range | 0.0–100.0°C |
| Calibration | Two-point (zero + user-defined point) |
| Electrode | Replaceable CS6930 Dissolved Ozone Sensor |
| IP Rating | IP67 |
| Display | Backlit 20×30 mm LCD, multi-line |
| Auto-off | 5 min idle |
| Power | 1×1.5 V AAA battery |
| Dimensions | 185×40×48 mm |
| Weight | 95 g |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | FCL30 |
| Instrument Type | Portable |
| Measurement Principle | Amperometric (Tri-Electrode) |
| Measured Parameter | Free Residual Chlorine |
| Range | 0–10.00 ppm |
| Accuracy | ±1% F.S. |
| Repeatability | ±1% F.S. |
| Resolution | 0.01 ppm |
| Detection Limit | 0 ppm |
| Temperature Range | 0.0–100.0°C |
| Calibration | 2-point (zero + span) |
| Data Storage | 10 readings |
| Enclosure Rating | IP67 |
| Display | Multi-line LCD (21 × 34 mm), auto-backlit |
| Power | 1 × 1.5 V AAA battery |
| Dimensions (H×W×D) | 185 × 40 × 48 mm |
| Weight | 95 g |
| Electrode | Replaceable CS5930 amperometric tri-electrode sensor |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Model | FCL30-R |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Potentiometric Sensor |
| Measured Parameter | Free Residual Chlorine |
| Range | 0–2.00 mg/L |
| Accuracy | ±1% F.S. |
| Repeatability | ±1% F.S. |
| Resolution | 0.01 mg/L |
| LOD | 0.035 mg/L |
| Auto Temperature Compensation | 5.0–45.0 °C |
| pH Compensation Input Range | 6.5–8.5 |
| Electrode | Replaceable CS5931 Free Chlorine Sensor |
| Display | Backlit LCD (20 × 30 mm) |
| Power | 1 × 1.5 V AAA battery |
| IP Rating | IP67 |
| Dimensions (H×W×D) | 185 × 40 × 48 mm |
| Weight | 95 g |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Model | MD110 |
| Stirring Volume | 1 L (max) |
| Speed Range | 60–2000 rpm |
| Control | Digital LCD Display |
| Drive System | Four-Pole Electromagnetic Coil |
| Plate Material | PET Surface |
| Housing Material | PA+GF |
| Dimensions (W×D×H) | 11 × 169 × 109 mm |
| Weight | 0.3 kg |
| Max Load Capacity | 1.5 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −10 to +70 °C |
| Relative Humidity | ≤85% RH |
| Protection Rating | IP65 (per EN 61010 & EN 61326) |
| Power Input | 100–240 VAC, 50–60 Hz |
| Output | 12 VDC |
| Power Consumption | 5 W |
| Compliance | CE-marked, EMI/EMC compliant for electrochemical measurement environments |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | ORP30 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| ORP Range | −900 to +900 mV |
| ORP Resolution | 1 mV |
| ORP Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C (32–212 °F) |
| Temperature Resolution | 0.1 °C / 1 °F |
| Calibration | Two-point using standard solutions (86 mV and 255 mV) |
| Electrode | Replaceable CS2930 platinum disc planar ORP electrode |
| Display | Multi-line LCD (21 × 34 mm) with auto-backlight |
| Ingress Protection | IP67 |
| Auto-power-off | 5 minutes of inactivity |
| Power | 1 × 1.5 V AAA battery |
| Dimensions (H×W×D) | 185 × 40 × 48 mm |
| Weight | 95 g |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | PH30 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | -2.00 to +16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Standards | USA (4.01, 7.00, 10.01) and NIST traceable (4.01, 6.86, 9.18) |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Compensation | ATC / MTC |
| Electrode | Replaceable high-impedance flat-surface electrode (CS1930) |
| Display | Multi-line LCD (21 × 34 mm), backlight with energy-saving mode |
| IP Rating | IP67 |
| Auto-off | 5 min |
| Power | 1 × 1.5 V AAA battery (>500 h lifetime) |
| Dimensions | 185 × 40 × 48 mm |
| Weight | 95 g |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | PH500 |
| pH Range | -2.00 to 16.00 |
| Resolution (pH) | 0.01 pH |
| Accuracy (pH) | ±0.2% F.S. |
| mV Range | -2000 to +2000 mV |
| Resolution (mV) | 1 mV |
| Accuracy (mV) | ±0.2% F.S. |
| Temperature Range | -10.0 to 110.0 °C |
| Resolution (Temp) | 0.1 °C |
| Accuracy (Temp) | ±0.2 °C |
| Calibration | Auto 3-point with selectable buffer sets (e.g., 4.00/6.86/9.18 or 4.01/7.00/10.01) |
| Data Storage | 50 readings |
| Auto Power-Off | After 10 min idle |
| Dimensions | 140 × 210 × 35 mm (W×L×H) |
| Weight | 650 g |
| Operating Environment | -5 to 60 °C, <90% RH |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Asia-Pacific Manufactured |
| Model | PG200N |
| Price Range | USD 700–1,400 |
| Instrument Type | Silicon Photodiode-Based Spectroradiometer with PAR-Optimized CMOS Linear Sensor |
| Spectral Range | 350–800 nm |
| Wavelength Resolution | 1 nm |
| FWHM | ~12 nm |
| Cosine Correction | CIE 1990 Compliant |
| Accuracy (Illuminance) | ±5% @ Standard Illuminant A (2856 K, 20,000 lx) |
| PPFD Range | 1–3,000 µmol/(m²·s) |
| Irradiance Range | 0.5–1,000 W/m² |
| Lux Range | 70–150,000 lx |
| Repeatability (2σ) | 0.2% |
| Colorimetric Accuracy | ±0.0025 in CIE 1931 x,y |
| CCT Accuracy | ±2% |
| CRI Accuracy | ±1.5% |
| IP Rating | IP66 |
| Display | 4.3" capacitive touch LCD (800×480) |
| Battery Life | Up to 5 hours (2500 mAh Li-ion) |
| Data Storage | ~68,000 records on 8 GB microSD |
| Connectivity | USB-C, Bluetooth 5.0, microSD |
| Operating Temp | 0–35 °C, ≤70% RH (non-condensing) |
| Weight | 280 g ±10 g |
| Compliance | JIS C 1609-1:2006 Class AA, DIN 5032-7 Class B |
