HuaiAi
Filter
Showing all 29 results
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | GC-9760A |
| Price Range | USD 14,000 – 42,000 |
| Dimensions | 380 × 450 × 180 mm |
| Weight | <15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Column Oven Temp Range | 8 °C above ambient to 400 °C (±0.1 °C) |
| TCD Detection Limit | ≤ 100 μL/L (H₂) |
| FID Detection Limit | ≤ 0.1 μL/L (C₂H₂) |
| Linear Dynamic Range | ≥10⁴ (TCD), ≥10⁶ (FID) |
| Standard Compliance | GB/T 17623–1998, GB/T 7252–2001, DL/T 703–1999 |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9560 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Petrochemical & Electronic Specialty Gases |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Oven Cooling Time | <5 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-1 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Ramp Rate | 1–40 °C/min |
| Cool-down Time | ~7 min (350 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Column Oven Precision | ±0.1 °C |
| Programmed Temperature Steps | 8-step |
| Hold Time per Step | 0–655 min (1-min increments) |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (n-hexadecane / isooctane) |
| FID Baseline Noise | ≤2×10⁻¹³ A |
| FID Drift | ≤2×10⁻¹² A/30 min |
| FID Linearity | ≥10⁶ |
| TCD Sensitivity | ≥2500 mV·mL/mg (n-hexadecane / isooctane) |
| TCD Baseline Noise | ≤20 µV |
| TCD Drift | ≤100 µV/30 min |
| TCD Linearity | ≥10⁴ |
| Dimensions | 655 mm (W) × 500 mm (H) × 480 mm (D) |
| Weight | ~48 kg |
| Power Supply | 220 V ± 22 V, 50 Hz, ≥2 kW |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GC-9560-EG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Ultra-High-Purity (UHP) and Electronic Grade (EG) Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 400 °C → 50 °C in ~7 min |
| Carrier Gas Flow Control Range | 0–400 mL/min |
| Carrier Gas Pressure Control Range | 0–1000 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–400 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GC-9560-GAS |
| Pricing | Upon Request |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Target Analytes | H₂, O₂, CO, CO₂, C₂H₂, CH₃OH, PH₃ |
| Detection Limits (ppm) | H₂/O₂/PH₃ ≤ 0.01 |
| Compliant Standards | GB/T 7715–2003, GB/T 7716–2002, GB/T 3393–2009, GB/T 3394–2009, GB/T 12701–1990, GB/T 3396–2002 |
| Column Configuration | Four-Valve, Five-Column Center-Cut & Back-Flush System |
| Sample Valve | Purge-Protected 6-Port or 10-Port Rotary Valve |
| Auxiliary Components | Integrated He Purifier, Zero-Dead-Volume Sampling Valve |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | GC-9560-HB |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Ramp Rate | 1–40 °C/min |
| Cooling Rate | ~7 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry Specific |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Rate | ~50 °C in ≈7 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560-HG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Ultra-High-Purity (UHP) Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Heating Rate | 1–40 °C/min |
| Cooling Rate | ~7 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization (PDHID) |
| Detection Limit | ≤1.0×10⁻¹⁰ g/mL (for organic compounds) |
| H₂ | 5 ppb, O₂/Ar: 10 ppb, N₂: 10 ppb, CH₄: 5 ppb, CO: 25 ppb, CO₂: 5 ppb |
| Temperature Control Precision | ±0.1 °C (eight independent zones) |
| Programmed Temperature Ramping | 8-step |
| Data Acquisition | 20 Hz, 24-bit A/D, dynamic range 10⁶ |
| Compliance | GB/T 28726–2012, GB/T 3634.2–2011, GB/T 14599–2008, GB/T 8979–2008, GB/T 4842–2006, GB/T 4844–2011, GB/T 17873–1999, GB/T 5829–2006, GB/T 5828–2006, HG/T 3633–1999, GB 10621–2006, GB/T 23938–2009, GB/T 28125.1–2011 |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-9560-HQ |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Rate | ~7 minutes from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-9560-HS |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum Refining & Fuel Quality Control |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Time | ~7 min (350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-HT |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +8°C to 399°C |
| Maximum Ramp Rate | 40°C/min |
| Cooling Rate | 350°C → 50°C in <5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GC-9560-HTP |
| Price Range | USD 14,000 – 21,000 (FOB Shanghai) |
| Application Scope | General-Purpose Catalytic Reaction Monitoring |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (PRC) |
| Model | GC-9560-HTP |
| Pricing | Upon Request |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9560-N2 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry–Specific |
| Temperature Control Range | Ambient + 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 6 °C/min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-9560-PDD |
| Temperature Control Range | 0–400 °C |
| Ramp Rate | 0–40 °C/min |
| Cool-down Rate | 350 °C → 50 °C (typical) |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 psi |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDD) |
| Detection Limit for Trace Impurities | ≤5 ppb (v/v) in high-purity SiCl₄ matrix |
| Application Focus | Ultra-high-purity electronic-grade gas analysis (e.g., SiCl₄, SiHCl₃, SiH₂Cl₂, CH₃SiCl₂) |
| Column Configuration | Multi-oven column switching architecture with center-cutting valving |
| Sample Introduction | Backflush-capable, purged valve system with active guard gas routing |
| Pressure Calibration | Integrated automatic inlet pressure correction algorithm for variable-base-gas samples |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560-PED |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Ultra-High-Purity Gas Analysis |
| Temperature Control Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Cooling Rate | 350 °C to 50 °C in ≤7 min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa (8-step programmable) |
| Carrier Gas Flow Control Range | 0–0.4 MPa (8-step programmable) |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.1 MPa |
| Injector Total Flow Setting Range | 0–50 mL/min |
| Detection Limit | Sub-ppb (e.g., 0.5–20 ppb depending on analyte and carrier gas) |
| Temperature Stability | ±0.1 °C |
| Programmable Temperature Program | 8-stage |
| Dimensions | 655 mm (W) × 500 mm (H) × 480 mm (D) |
| Weight | ~48 kg |
| Power Supply | 220 V ±22 V, 50 Hz, ≥2 kW |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-9580-HD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry Dedicated |
| Temperature Control Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Time | ≤7 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Temperature Control Range | 0 °C to 400 °C |
| Oven Ramp Rate | 8 °C to 350 °C in ≤7 min |
| Oven Cool-Down Rate | 350 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Dimensions | 790 mm (W) × 502 mm (H) × 490 mm (D) |
| Weight | ~50 kg |
| Power Supply | 220 V ±10%, 50 Hz, ≥2 kW |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9760B |
| Price Range | USD 42,000 – 70,000 |
| Analysis Cycle | <20 min |
| Measurement Error | <3% |
| Thermal Stabilization Time | <30 min |
| Operating Ambient Temperature | −10 °C to +50 °C |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Oven Temperature Accuracy | ±0.1 °C |
| Detector Temperature Range | 8 °C above ambient to 399 °C |
| Detector Temperature Accuracy | ±0.1 °C |
| Dimensions | 380 × 450 × 180 mm |
| Weight | <15 kg |
| Power Supply | 220 V ± 22 V, 50 Hz |
| Max. Power Consumption | ≤2 kW |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | GC-9780B |
| Instrument Type | Portable Gas Chromatograph |
| Application Domain | Power Industry–Specific |
| Oven Temperature Range | 8 °C above ambient to 400 °C |
| Ramp Rate | 5 °C/min |
| Cool-down Rate | 350 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Control Range | 0–30 mL/min |
| Carrier Gas Pressure Control Range | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Detection Limits | 0.05–20,000 ppm (compound-dependent) |
| Analysis Cycle Time | <20 min |
| Quantitative Repeatability | ≤1% RSD |
| Qualitative Repeatability | ≤0.2% RSD |
| Baseline Noise | ≤0.1 mV |
| Baseline Drift | ≤0.5 mV/30 min |
| Pulsed Discharge Detector (PDD) Sensitivity | ≤1.0×10⁻¹¹ g/mL (for representative analytes) |
| Power Supply | 24 V DC (internal Li-ion battery, 21,000 mAh) |
| AC input | 220 V ±10%, 50 Hz |
| Dimensions | 640 × 585 × 420 mm |
| Weight | <50 kg |
| Power Consumption | ≤200 W |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | GC9560 |
| Price Range | USD 21,000 – 28,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Temperature Control Range | 0–400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Cooling Rate | 350 °C → 50 °C (typical) |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.5 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.5 MPa |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | HA-2030 |
| Quotation | Upon Request |
| Application Domain | Power Industry Dedicated |
| Oven Temperature Range | Ambient to 450 °C |
| Oven Ramp Rate | 10 °C/min |
| Carrier Gas Pressure Range & Control | 0.4–0.8 MPa |
| Injector Maximum Operating Temperature | 50 °C |
| Injector Pressure Setting Range | 0–0.2 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | 8 °C above ambient to 400 °C |
| Carrier Gas Flow Range & Control | 1–1000 mL/min |
| Detector Configuration | PDHID S Pro+ (Pulsed Discharge Helium Ionization Detector) |
| Channel Options | Single-Channel or Multi-Channel Parallel Analysis |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HA-9660-PLUS-H2O |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Detector Type | Pulsed Discharge Helium Ionization Detector (PDD) |
| Moisture Detection Limit | ≤10 ppb (typical conditions) |
| Linearity | R² > 0.9999 |
| Repeatability | RSD ≤ 3% |
| Compatible Gases | Ultra-high-purity N₂, Ar, He, H₂, O₂, CO₂, SF₆ |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | HA-9660-Plus-S |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Detection Principle | Gas Chromatography with Pulsed Discharge Helium Ionization Detection (PDHID) |
| Detection Limit | <1 ppb for H₂S, COS, CS₂, CH₃SH |
| Linearity Range | 1 ppb – 5 ppm (R² > 0.999 across six orders of magnitude) |
| Precision | RSD < 3% (n = 6) |
| Dilution System | HA-11 Dual-Stage Precision Gas Dilutor (1–10,000×) |
| Flow Path | Ultra-Inert, Sulfur-Resistant Capillary and Valving Architecture |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HA-9680 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Temperature Control Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-Down Rate | 400 °C to ambient |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa (accuracy: ±0.01 MPa) |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.1 MPa |
| Injector Total Flow Setting Range | 0–50 mL/min |
| Dimensions | 1300 mm (W) × 1800 mm (H) × 1000 mm (D) |
| Ambient Operating Temperature | −20 °C to +40 °C |
| Electrical Supply | 220 VAC, max. 5 kW |
| Inlet Gas Supply Pressure | 0.4–0.8 MPa |
| Positive-Pressure Purge Duration | 30 min |
| Positive-Pressure Range | 60–200 Pa |
| Detector Options | TCD, FID, PDD, FPD (single or multi-detector configuration) |
| Output Interfaces | 4–20 mA analog, Modbus RTU |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HA-9680-D |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | 0–300 °C (operating range), max. ramp rate 10 °C/min |
| Carrier Gas Pressure Control Range | 0–0.6 MPa |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Explosion Protection Rating | Ex db IIC T4 Gb |
| Ingress Protection Rating | IP66 |
| Remote Control Interface | Web-based and WeChat Mini Program (cloud-connected) |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HA-9680-H |
| Application Domain | High-Purity Hydrogen Gas Analysis |
| Oven Temperature Range | Ambient to 450 °C |
| Ramp Rate | 10 °C/min |
| Carrier Gas Pressure Control Range | 0.4–0.8 MPa |
| Injector Maximum Operating Temperature | 50 °C |
| Injector Pressure Setting Range | 0–0.2 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HA-9680-L |
| Price Range | USD 28,000 – 52,000 |
| Instrument Type | Online Gas Chromatograph |
| Application Domain | Petrochemical Industry Specific |
| Explosion Protection Certification | NEPSI Certified EX d ib mb px II CT4 Gb |
| Sample Phase | Liquid |
| Injection Mode | Direct Liquid Injection |
| Regulatory Compliance | Meets IEC 60079-0, IEC 60079-1, IEC 60079-11 for Zone 1/2 hazardous areas |
| Thermal Management | Integrated heated sampling & transfer lines (up to 180 °C) |
| Detector Options | FID, TCD, PID (configurable) |
| Data Output | 4–20 mA analog, Modbus TCP, OPC UA |