| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | GAS-10A |
| Sample Capacity | 10 gas sampling bags |
| Control Interface | LCD touch screen |
| Actuation | Solenoid-valve-based automated sequencing |
| Application Domain | Ambient air pre-concentration, VOC analysis, environmental monitoring, laboratory GC/GC-MS sample introduction |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | GC-8890SD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry Dedicated |
| Temperature Control Range | Ambient +6°C to 399°C (adjustable in 1°C increments) |
| Ramp Rate | 0–40°C/min (adjustable in 0.1°C increments) |
| Cooling Rate | ≤3 min (from 200°C to 100°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min, 7-step programmable |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | JPA-3L |
| Output Flow Rate | 2.0–3000 mL/min |
| Output Pressure | 0.4 MPa |
| Noise Level | <30 dB(A) |
| Dimensions (L×W×H) | 415 × 200 × 370 mm |
| Weight | ~22 kg |
| Power Consumption | ≤150 W |
| Input Voltage | 220 ± 22 V AC, 50 ± 0.5 Hz |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Air Purity | Oil-free and desiccated |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | JP-300E |
| Gas Purity | N₂ ≥ 99.999%, H₂ ≥ 99.99995%, Air (HC < 0.1 ppm) |
| Output Flow | N₂: 0–500 mL/min, H₂: 0–500 mL/min, Air: 0–5 L/min |
| Output Pressure | N₂/H₂: 0.3 MPa, Air: 0.4 MPa |
| Design | Integrated monolithic chassis |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 550 W |
| Dimensions (L×W×H) | 480 × 420 × 480 mm |
| Weight | 45 kg |
| Operating Environment | 0–40 °C, RH < 85%, non-corrosive, low-dust ambient |
| Compliance | Designed for GLP-compliant GC laboratories |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | OG-2000V |
| Instrument Type | Laboratory Gas Chromatograph for Geochemical Pyrolysis |
| Application Domain | Petroleum & Petrochemical Industry |
| Temperature Control Range | 360 ± 0.5 °C (FID), 600 ± 0.5 °C (Pyrolysis Furnace & Oxidation Furnace) |
| Ramp Rate | < 0.5 °C/min |
| Maximum Injector Temperature | 800 °C |
| Detection Principle | Flame Ionization Detection (FID) |
| Minimum Hydrocarbon Detection | 0.001 mg HC/g rock |
| Baseline Drift | < 0.1 mV/30 min |
| Linear Dynamic Range | 10⁶ |
| Analysis Cycle Time (Full Pyrolysis–Residual Carbon) | 14.5 min |
| Number of Predefined Thermal Programs | 4 (Source Rock, Reservoir Rock, Thermal Simulation, User-Defined) |
| Temperature Linearity Deviation | < 0.5 °C/min |
| Interface | USB 2.0 (Direct Signal Output to PC) |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | QT-3000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring & Petroleum Geochemistry |
| Temperature Control Range | Ambient +8 °C to 420 °C (0.1 °C increment) |
| Oven Ramp Rate | 0.1–80 °C/min (0.1 °C increment) |
| Cooling Rate | 450 °C → 50 °C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (EPC/EFC) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (EPC/EFC) |
| Injector Max Temp | 400 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| FID Detection Limit | ≤2×10⁻¹² g/s (benzene) |
| FID Noise | ≤0.02 mV |
| FID Drift | ≤0.15 mV/h |
| FID Linearity | ≥10⁷ |
| Temperature Stability | ±0.05 °C (≤200 °C), ±0.1 °C (>200 °C) |