Konica Minolta
Filter
Showing 61–90 of 111 results
| Brand | Konica Minolta |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CR-10 |
| Price | USD 2,250 (approx.) |
| Instrument Type | Portable Spectrophotometric Colorimeter |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Tungsten Halogen Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.1 (for white tile, 10 measurements) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-14 |
| Illumination/Reception Geometry | 8°/diffuse (excluding specular component) |
| Aperture Size | Ø8 mm |
| Whiteness Indices | CIE Whiteness, Hunter Whiteness, ASTM E313 Whiteness |
| Yellowness Indices | ASTM E313, ASTM D1925 |
| Color Space Display | CIE Yxy (1931) |
| Repeatability (Std. Dev.) | ≤0.5 (CIE Whiteness), ≤0.1 (Hunter Whiteness) on white calibration tile |
| Measurement Interval | ~1 s |
| Power Supply | 4 × AA alkaline batteries (2000 measurements at 10-s intervals) or optional AC adapter AC-A308 |
| Operating Environment | 0–40 °C, ≤80% RH (non-condensing at ≤35 °C) |
| Standard Accessories | CR-A74 White Calibration Tile, CR-A68 Soft Carrying Case, CR-A79 Protective Cap, CR-73 Wrist Strap, 4 × AA batteries |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-20 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (including specular component) |
| Light Source | Pulsed xenon lamp |
| Spectral Range | 360 nm to 750 nm |
| Repeatability | ΔE*ab ≤ 0.1 (std. dev., measured 30 times on white calibration tile at 10-sec intervals) |
| Aperture | Ø8 mm |
| Data Storage | 1,000 measurement sets |
| Measurement Time | ~1 second |
| Observer Angle | 10° |
| Illuminant | D65 |
| Supported Color Spaces | CIE L*a*b*, L*C*h, Yxy, XYZ, Munsell (D65) |
| Color Indices | WI (CIE/ASTM E313-96), Tint (CIE/ASTM E313-96), YI (ASTM E313-96) |
| Compliance | DIN 5033-7, JIS Z 8722 (Condition d), ISO 7724-1, CIE No. 15, ASTM E1164 |
| Power Supply | 4 × AA alkaline/Ni-MH batteries, USB bus power, or optional AC adapter |
| Dimensions | 66 mm (W) × 159.5 mm (H) × 85 mm (D) |
| Weight | 420 g |
| Operating Environment | 0–40°C, ≤85% RH (non-condensing at 35°C) |
| Storage Environment | −20–40°C, ≤85% RH (non-condensing at 35°C) |
| Interface | USB 2.0 |
| Display | Color data, mean values (up to 999 readings), pass/fail indicators |
| Language Support | English, Japanese |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-20 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Repeatability | ΔE*ab ≤ 0.1 (standard deviation) |
| Data Storage | Up to 1,000 measurement sets (including reference) |
| Color Spaces | CIE L*a*b*, L*C*h, Yxy, XYZ, Munsell, WI (CIE/ASTM E313-96), Tint (CIE/ASTM E313-96), YI (ASTM E313-96) |
| Compliance | ASTM E313, ISO 7724, JIS Z 8722, CIE No. 15 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-20 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (with specular component included) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360–750 nm |
| Repeatability | ΔE*ab ≤ 0.1 (std. dev., 30 measurements on white calibration tile at 10-sec intervals) |
| Aperture | Ø8 mm |
| Observer Angle | 10° |
| Illuminant | D65 |
| Display | Backlit LCD |
| Data Storage | Up to 1,000 measurement sets (including reference) |
| Interface | USB 2.0 |
| Power | 4 × AA alkaline/Ni-MH batteries, USB bus power, or AC adapter (optional) |
| Dimensions | 66 × 159.5 × 85 mm |
| Weight | 420 g (without batteries) |
| Compliance | DIN 5033-7, JIS Z 8722 Condition d, ISO 7724-1, CIE No. 15, ASTM E1164 |
| Brand | Konica Minolta |
|---|---|
| Origin | Shanghai, China |
| Model | CR-400 / CR-410 |
| Type | Portable Spectrophotometric Colorimeter |
| Optical Geometry | d/8° integrating sphere (with specular component included) |
| Light Source | Pulsed xenon arc lamp |
| Spectral Range | 300–700 nm |
| Repeatability | ΔE*ab ≤ 0.07 (after white calibration plate measurement, 30 times at 10 s intervals) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-400 |
| Type | Portable Color Difference Meter |
| Optical Geometry | d/8° integrating sphere (diffuse illumination, 8° viewing, including specular component) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | Y Reflectance: 0.01–160.00% |
| Repeatability | ΔE*ab ≤ 0.07 (std. dev., white calibration, 30 measurements at 10 s intervals) |
| Instrument Error | ΔE*ab ≤ 0.6 (BCRA Series II 12-color average, CIE D65 illuminant, 2° standard observer) |
| Measurement Aperture | 8 mm (measuring), 11 mm (illumination) |
| Measurement Time | 1 s |
| Minimum Interval | 3 s |
| Data Storage | 1,000 measurements (instrument only) |
| Display | Backlit dot-matrix LCD (15×9 characters + icon line) |
| Power | 4× AAA alkaline/Ni-MH batteries or AC adapter AC-A17 (120 V / 230 V, 50–60 Hz) |
| Dimensions | 102 × 244 × 63 mm |
| Weight | ~550 g (incl. batteries, excl. cable) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-400 / CR-410 |
| Illumination/Reception Geometry | d/0 (diffuse illumination, 0° viewing |
| Detector | Silicon photodiodes (6 channels) |
| Light Source | Pulsed xenon lamp |
| Measurement Time | 1 s |
| Minimum Interval Between Measurements | 3 s |
| Repeatability | ΔE*ab ≤ 0.07 (after white calibration, 30 measurements at 10 s intervals) |
| Instrument Error | ΔE*ab ≤ 0.6 (CR-400), ≤ 0.8 (CR-410) against BCRA Series II 12-color standard set |
| Aperture Size | CR-400: Ø8 mm measurement / Ø11 mm illumination |
| CR-410 | Ø50 mm measurement / Ø53 mm illumination |
| Reflectance Range | Y = 0.01–160.00% |
| Observer Angle | CIE 2° standard observer |
| Illuminants | C, D65 |
| Color Spaces | XYZ, Yxy, L*a*b*, L*C*h, CIELAB, CIELUV, CMC(l:c), CIE 1994, CIE 2000, Hunter Lab, CIE Whiteness (WI) & Yellowness (YI) per ASTM E313/D1925 (C or D65 dependent) |
| Display | Backlit dot-matrix LCD (15 × 9 characters + icon line) |
| Memory Capacity | 1000 measurements (head-only mode) |
| Interface | RS-232C (default baud rate: 9600 bps) |
| Power | 4 × AAA alkaline or Ni-MH batteries |
| Dimensions (W × H × D) | 102 × 244 × 63 mm |
| Weight | ~550 g (CR-400), ~570 g (CR-410), incl. batteries |
| Operating Environment | 0–40 °C, ≤85% RH (non-condensing) |
| Storage Environment | −20–40 °C, ≤85% RH (non-condensing) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-400 / CR-410 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (with specular component included) |
| Light Source | Pulsed xenon lamp |
| Spectral Range | Y Reflectance 0.01–160.00% |
| Repeatability | ΔE*ab ≤ 0.07 (standard deviation, after white calibration tile measurement, 30 times at 10-second intervals) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-400 / CR-410 |
| Instrument Type | Portable |
| Light Source | Pulsed Xenon Lamp |
| Aperture Options | Φ8 mm (CR-400), Φ50 mm (CR-410) |
| Repeatability | ΔE*ab ≤ 0.07 (after white calibration, 30 measurements at 10-sec intervals) |
| Accuracy | ΔE*ab ≤ 0.6 (CR-400), ≤ 0.8 (CR-410) |
| Memory Capacity | 100 target colors + 1,000 measurement records (standalone) |
| Display | Backlit LCD, 6-language support (English, German, French, Italian, Spanish, Japanese) |
| Power | Rechargeable battery or AC adapter |
| Compliance | Designed for ISO 7724-1, CIE No. 15, ASTM E308, and JIS Z 8722 colorimetric standards |
| Brand | KONICA MINOLTA |
|---|---|
| Origin | Japan |
| Model | CS-100A |
| Type | SLR-type tristimulus spot chroma meter for luminance and colorimetric measurement |
| Luminance Range (Fast) | 0.01–299,000 cd/m² |
| Luminance Range (Slow) | 0.01–49,900 cd/m² |
| Luminance Accuracy | ±2% ±1 digit |
| Chromaticity Accuracy (x,y) | ±0.004 (CIE Illuminant A, 18–28°C) |
| Repeatability (Y) | ±0.2% ±1 digit |
| Repeatability (x,y) | ±0.001 (Y ≥100 cd/m², fast mode) |
| Measurement Angle | 1° |
| Field of View | 9° with 1° measurement area indicator |
| Optical System | 85 mm f/2.8 lens |
| Focus Distance | 1014 mm to infinity |
| Sensor | Three filtered silicon photodiodes approximating CIE 1931 color matching functions |
| Response Time | Fast (sampling: 0.1 s, display: 0.8–1.0 s) |
| Slow (sampling | 0.4 s, display: 1.4–1.6 s) |
| Display | External 3-digit LCD (Y, x, y) |
| Interface | RS-232C (4800 bps) |
| Power | 9 V alkaline battery (included) |
| Dimensions (W×H×D) | 79 × 208 × 154 mm |
| Weight | 890 g (without battery) |
| Operating Environment | 0–40°C, ≤85% RH (non-condensing at ≤35°C) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-150 / CS-160 |
| Measurement Angle | 1° (CS-150) / 1/3° (CS-160) |
| Luminance Range | 0.01–999,900 cd/m² (CS-150) / 0.1–9,999,000 cd/m² (CS-160) |
| Colorimetric Compliance | CIE 1931 x(λ), y(λ), z(λ) tristimulus matching |
| Spectral Response Match | Optimized to CIE V(λ) photopic luminosity function |
| Minimum Measured Area | 14.4 mm Ø (CS-150, 1014 mm distance) / 4.5 mm Ø (CS-160, 213 mm) |
| Repeatability | ±0.2% +1 digit (luminance), ±0.001 (chromaticity at ≥10 cd/m²) |
| Accuracy | ±2% ±1 digit (luminance), ±0.004 (chromaticity at ≥5 cd/m²) |
| Data Storage | 1,000 measurements |
| Interface | USB 2.0 (data transfer & bus power) |
| Software | CS-S20w (included) |
| Calibration Channels | 10 user-definable reference sources |
| Operating Temp. | 0–40°C, ≤85% RH (non-condensing) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model Series | CS-150 / CS-160 |
| Measurement Angles | CS-150 — 1° |
| Luminance Range | CS-150 — 0.01 to 999,900 cd/m² |
| Output | CIE 1931 xy Chromaticity Coordinates, Luminance (Lv), Correlated Color Temperature (CCT), Dominant Wavelength, Excitation Purity |
| Compliance | JIS Z 8722, CIE No. 15, ISO/CIE 11664-3, ASTM E308 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-200 |
| Measurement Angles | 1° / 0.2° / 0.1° |
| Luminance Range | 0.01–20,000,000 cd/m² (at 0.1°) |
| Accuracy (Lv) | ±2% ±1 digit (≥10 cd/m², Source A, slow mode) |
| Accuracy (xy) | ±0.003 (≥10 cd/m², Source A, slow mode) |
| Repeatability (Lv) | ±0.1% ±1 digit (2–200,000 cd/m², 2σ, auto mode) |
| Spectral Method | Grating + Linear Photodiode Array |
| Minimum Measured Area | 0.1 mm (with close-up lens) |
| Interface | USB 1.1 |
| Power | AC adapter or 4× AA batteries (~3 h continuous operation) |
| Dimensions | 95 × 127 × 330 mm |
| Weight | 1.8 kg (body only) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-200 |
| Type | Color and Luminance Meter |
| Measurement Principle | Spectral Matching Method (CIE 1931 2° Standard Observer) |
| Photodetector | Silicon Photodiode |
| Luminance Range | 0.01 to 20,000,000 cd/m² (at 0.1° field of view) |
| Illuminance Range | 0.1 to 99,990 lx |
| Chromaticity Accuracy (xy) | ±0.002 (Std. Illuminant A, 800 lx) |
| Repeatability (xy) | ±0.0005 |
| Temporal Stability | 2 measurements/sec (continuous) |
| Output Interface | RS-232C |
| Display | 4-digit LCD with backlight |
| Power | Four AA alkaline batteries (≈72 h continuous use) or AC adapter AC-A10 |
| Dimensions | 69 × 174 × 35 mm |
| Weight | 215 g (body only) |
| Compliance | JIS C 1609-1993 Class AA (fs ≤ 8%), ISO/CIE traceable calibration protocols |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS-200 Series |
| Price | USD 16,800 (FOB Yokohama) |
| Measurement Principle | Spectral Response Curve Fitting with 40-Channel Photodiode Array |
| Luminance Range | 0.01 to 20,000,000 cd/m² |
| Field of View Options | 1°, 0.2°, 0.1° |
| CIE Observer Modes | 2° and 10° Standard Observer |
| Compliance | CIE 1931 Color Matching Functions, JIS Z 8722, ISO/CIE 11664-3, ASTM E308-22 |
| Power Supply | Rechargeable Li-ion Battery or AC Adapter |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-2000 |
| Measurement Wavelength Range | 380–780 nm |
| Wavelength Resolution | 0.9 nm/pixel |
| Spectral Bandwidth (FWHM) | <5 nm |
| Measurement Angles | 1°, 0.2°, 0.1° (interchangeable) |
| Luminance Range (A-source) | 0.003–5,000 cd/m² (1°), 0.075–125,000 cd/m² (0.2°), 0.3–500,000 cd/m² (0.1°) |
| Minimum Displayed Luminance | 0.00002 cd/m² |
| Luminance Accuracy | ±2% (A-source, ≥0.003 cd/m²) |
| Chromaticity Accuracy | x,y ±0.003 to ±0.001 (dependent on luminance level) |
| Repeatability (2σ) | Luminance 0.15–0.4%, Chromaticity 0.0004–0.002 |
| Polarization Error | ≤2% (1°), ≤3% (0.1°/0.2°) |
| Integration Time | Fast mode 0.005–16 s, Normal mode 0.005–120 s |
| Measurement Time | 2–243 s |
| Operating Environment | 5–35°C, RH ≤80% (non-condensing) |
| Dimensions | 158 × 200 × 300 mm (main unit), Ø70 × 95 mm (lens) |
| Weight | 6.2 kg |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-2000 / CS-2000A Spectroradiometer |
| Wavelength Range | 380–780 nm |
| Wavelength Resolution | 0.9 nm/pixel |
| Spectral Bandwidth (FWHM) | <5 nm |
| Wavelength Accuracy | ±0.3 nm (at Hg-Cd lamp calibration lines: 435.8, 546.1, 643.8 nm) |
| Measurement Angles | 1°, 0.2°, 0.1° (interchangeable optical attachments) |
| Luminance Range (Illuminant A) | CS-2000: 0.003–5,000 cd/m² (1°), 0.075–125,000 cd/m² (0.2°), 0.3–500,000 cd/m² (0.1°) |
| CS-2000A | 0.0005–5,000 cd/m² (1°), 0.0125–125,000 cd/m² (0.2°), 0.05–500,000 cd/m² (0.1°) |
| Minimum Measurable Spot Size | ∅5 mm (standard), ∅1 mm (with close-up lens |
| Minimum Measurement Distance | 350 mm (standard), 55 mm (with close-up lens) |
| Radiant Exitance Detection Limit | 1.0×10⁻⁹ W/(sr·m²·nm) |
| Luminance Accuracy (Illuminant A) | ±2% |
| Chromaticity Accuracy (Illuminant A) | x,y ±0.001 (≥0.05 cd/m² for CS-2000A |
| Chromaticity Repeatability (2σ, Illuminant A) | x,y ≤0.0006 (e.g., 0.1–0.2 cd/m² and 2.5–5 cd/m² ranges) |
| Polarization Error | ≤2% (1°, 400–780 nm), ≤3% (0.1°/0.2°, 400–780 nm) |
| Integration Time | 5 ms–120 s (Normal mode) |
| Interface | USB 1.1, RS-232C |
| Operating Environment | 5–35°C, ≤80% RH (non-condensing) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Power Consumption | ~20 W |
| Dimensions (main unit) | 158 × 262 × 392 mm (W×H×D) |
| Lens | ∅70 × 95 mm |
| Weight | 6.2 kg |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-3000 Series |
| Measurement Principle | Diffraction-grating-based spectroradiometry |
| Luminance Range | 0.0005–3,000 cd/m² (typical, dependent on aperture and lens configuration) |
| Chromaticity Accuracy | ±0.002 in CIE x,y (against NIST-traceable standards) |
| Spectral Resolution | ≤5 nm FWHM |
| Integration Time | 10 ms–10 s (programmable) |
| Interface | USB 2.0, RS-232C, Ethernet (optional) |
| Compliance | ISO/CIE compliant spectral measurement architecture |
| Software Support | Konica Minolta SpectraMagic™ NX v3.x |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-3000HDR / CS-3000 |
| Measurement Angle Options | 1° / 0.2° / 0.1° (motorized) |
| Luminance Range (1°, CS-3000HDR) | 0.0001–100,000 cd/m² |
| Spectral Bandwidth (FWHM) | <5 nm |
| Chromaticity Accuracy (at 0.05 cd/m²) | x: ±0.0015, y: ±0.001, u': ±0.0014, v': ±0.0006 |
| Compliance | CIE 122:1996 |
| Measurement Modes | FAST, SUPER FAST1, SUPER FAST2, INTELLIGENT DARK, Frequency-Synchronized Integration |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | FD-7 |
| Product Type | Spectrodensitometer |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Compliance | ISO 13655:2009 M1 condition |
| Key Feature | Virtual Fluorescence Standard (VFS) technology |
| Weight | 350 g (main unit), 430 g (with aperture mask) |
| Spectral Measurement Capability | Supports D50-spectrum-referenced fluorescence evaluation |
| Wavelength Compensation | Automatic, performed during routine white calibration |
| Ambient Light Measurement | Yes, supports illuminance, CCT, and CIE tristimulus values under real-world lighting |
| Software Integration | basICColor catch all for strip scanning (MediaWedge, ECI2002, IT8.7/3) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | FD-9 |
| Product Type | Spectrodensitometer |
| Instrument Type | Desktop |
| Optical Geometry | d/8° integrating sphere |
| Compliance | ISO 5-4, ISO 13655:2017 (M0/M1/M2/M3), ASTM E308, ISO 2846-1 |
| Connectivity | USB 2.0, TCP/IP Ethernet |
| Display | Built-in high-resolution LCD touchscreen |
| Automation Support | Optional auto-feeder (up to 100 sheets) |
| Measurement Mode | Single-spot stop-and-measure (non-scanning) |
| Data Output | Multi-illumination condition simultaneous reporting (M0, M1, M2) |
| Software Interface | Konica Minolta SpectraMagic NX Pro (FDA 21 CFR Part 11 compliant audit trail optional) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | FD-9 |
| Optical Geometry | 45°a:0° (annular illumination) |
| Wavelength Range | 380–730 nm |
| Wavelength Interval | 10 nm |
| Spectral Bandwidth | ~10 nm |
| Measurement Aperture | ~3 mm |
| Light Source | LED |
| Reflectance Range | 0–150% |
| Repeatability | σΔE₀₀ ≤ 0.05 (after white calibration, 30 measurements at 1 s intervals) |
| Inter-instrument Agreement | ΔE₀₀ ≤ 0.3 (BCRA Series II 12-color tile average) |
| Measurement Time | ~4 minutes for 1500 patches |
| Compliance | CIE No. 15, ISO 7724-1, ISO 13655, DIN 5033 Teil 7, ASTM E1164, JIS Z 8722 |
| Interfaces | USB 2.0, 10/100Base-T Ethernet |
| Power Supply | AC 100–240 V, 50/60 Hz → DC 24 V, 5 A |
| Dimensions (FD-9 only) | 716 × 251 × 159 mm |
| Weight (FD-9 only) | ~10.5 kg |
| Operating Environment | 10–35 °C, 30–85% RH (non-condensing) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | LS-100 |
| Measurement Angle | 1° |
| Optical System | Single-lens reflex (SLR) with f=85 mm, F2.8 lens |
| Field of View (Finder) | 9° with diopter adjustment |
| Minimum Measurement Distance | ∞ to 1,014 mm (∞ to φ14.4 mm) |
| Close-up Lens Options | No.153 (φ18.7–φ8.0 mm), No.135 (φ8.7–φ5.2 mm), No.122 (φ4.3–φ3.2 mm), No.110 (φ1.5–φ1.3 mm) |
| Detector | Silicon photodiode |
| Spectral Match Error (fₛ) vs. CIE V(λ) | ≤8% |
| Response Modes | FAST (display time: 0.8–1.0 s |
| sampling | 0.1 s), SLOW (display time: 1.4–1.6 s |
| sampling | 0.4 s) |
| Luminance Range | FAST: 0.001–299,900 cd/m² |
| SLOW | 0.001–49,990 cd/m² |
| Accuracy | ±2% ±1 digit (>1,000 cd/m²) |
| Repeatability | ±0.2% ±1 digit (>1,000 cd/m²) |
| Temperature Drift | ±3% ±1 digit (0–40°C, referenced to 20°C) |
| Calibration Modes | Konica Minolta standard or user-defined reference (1 channel) |
| Luminance Ratio Mode | 1 channel, manual or measured reference input |
| Measurement Functions | Instant luminance, peak luminance, luminance ratio (%) |
| Display | 4-digit LCD (external & eyepiece-mounted with LED backlight) |
| Digital Interface | RS-232C compliant (4,800 bps), bidirectional control and data logging |
| Power Supply | One 9 V alkaline battery (JIS 6F22) or optional DP-10 data printer |
| Power Consumption | ~16 mA (finder illumination ON, measurement active) |
| Operating Environment | 0–40°C, ≤85% RH (non-condensing), Pollution Degree 2, Overvoltage Category II |
| Storage | −20–55°C, ≤85% RH (non-condensing) |
| Dimensions & Weight | 79 × 208 × 150 mm (W × H × D), 850 g (body only, no battery) |
| Standard Accessories | Lens cap, eyepiece ND filter, eyepiece cap, 9 V battery, carrying case |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | LS-150 / LS-160 |
| Luminance Range | 0.001–999,900 cd/m² (LS-150), 0.01–9,999,000 cd/m² (LS-160) |
| Measurement Angle | 1° (LS-150), 1/3° (LS-160) |
| Optical System | Single-Lens Reflex (SLR), f=85 mm, F2.8 |
| Spectral Response | Matched to CIE V(λ) Photopic Luminosity Function |
| Accuracy | ±2% ±2 digits (≤1 cd/m²), ±2% ±1 digit (>1 cd/m²) |
| Repeatability | 0.2% + 1 digit |
| Minimum Measured Area | Ø14.4 mm (1°), Ø4.5 mm (1/3°) |
| with optional macro lens | Ø1.3 mm (LS-150), Ø0.4 mm (LS-160) |
| Shortest Measurement Distance | 1012 mm (1°), 213 mm (1/3°) |
| Stray Light Suppression | ≤1% |
| Polarization Error | ≤1% |
| Temperature Drift | ≤0.2%/K |
| Compliance | DIN 5032-7 Class B (LS-150) |
| Interface | USB 2.0 |
| Power | USB bus power or AC adapter (optional) |
| Dimensions | 71 × 214 × 154 mm |
| Weight | 850 g (body only) |
| Brand | Konica Minolta |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Portable Colorimetric Luminance Meter |
| Model | LS-150 / LS-160 |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Tungsten-filament lamp |
| Luminance Range | 0.001–999,900 cd/m² (LS-150) |
| Repeatability | ±0.2% + 1 digit (luminance, reference source A) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | LS-150 / LS-160 |
| Luminance Range | 0.001–999,900 cd/m² (LS-150), 0.01–9,999,000 cd/m² (LS-160) |
| Measurement Angle | 1° / 1/3° |
| Optical System | Single-Lens Reflex (SLR), f=85 mm, F2.8 |
| Spectral Response | Matched to CIE V(λ) Photopic Luminosity Function |
| Accuracy | ±2% ±2 digits (≤1 cd/m²), ±2% ±1 digit (>1 cd/m²) |
| Repeatability | 0.2% + 1 digit |
| Minimum Measured Area | 14.4 mm Ø (1.3 mm Ø with optional close-up lens for LS-160) |
| Shortest Measurement Distance | 1012 mm (213 mm with close-up lens) |
| Operating Temperature | 0–40 °C, RH ≤85% (non-condensing) |
| Dimensions | 71 × 214 × 154 mm |
| Weight | 850 g (body only) |
| Compliance | DIN 5032-7 Class B (LS-150) |
| Interface | USB 2.0 |
| Power | USB bus power or AC adapter (optional) |
| Data Storage | 1,000 readings |
| Display | Backlit multi-digit LCD (external), 4-digit LED-backlit viewfinder LCD |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | LS-150 / LS-160 Series Luminance Meter |
| Luminance Range (LS-150, 1° FOV) | 0.001–999,900 cd/m² |
| Luminance Range (LS-160, 1/3° FOV) | 0.01–9,999,000 cd/m² |
| Minimum Measurable Luminance | 0.001 cd/m² |
| Field of View Options | 1° (LS-150), 1/3° (LS-160) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | MG-268 |
| Measurement Angles | 20°, 60°, 85° |
| Gloss Range | 0.0–2,000 GU (20°), 0.0–1,000 GU (60°), 0.0–160 GU (85°) |
| Repeatability | ±0.2 GU (0–99.9 GU), ±0.2% of reading (100–2,000 GU) |
| Inter-instrument Agreement | ±0.5 GU (0–99.9 GU), ±0.5% of reading (100–2,000 GU) |
| Measurement Area | 10×10 mm (20°), 9×15 mm (60°), 5×38 mm (85°) |
| Compliance | ISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z 8741, BS 3900, BS 6161-12 |
| Data Storage | 999 measurements with timestamp |
| Battery Life | ~10,000 readings (1.5 V AA alkaline) |
| Interface | USB 2.0, Bluetooth 2.0 |
| Operating Temperature | 15–40 °C, ≤85% RH (non-condensing) |
| Dimensions | 155 × 73 × 48 mm |
| Weight | 400 g |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | Multi Gloss 268 |
| Measurement Angles | 20°, 60°, 85° |
| Measurement Spot Size | 20°: 10 × 10 mm |
| 60° | 9 × 15 mm |
| 85° | 5 × 38 mm |
| Standards Compliance | ISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z 8741, BS 3900, BS 6161-12 |
| Measurement Range | 20°: 0.0–2000 GU |
| 60° | 0.0–1000 GU |
| 85° | 0.0–160 GU |
| Resolution | 0.1 GU (0.0–99.9 GU), 1 GU (100–2000 GU) |
| Repeatability | ±0.2 GU (0.0–99.9 GU), ±0.2% of reading (100–2000 GU) |
| Instrument Error | ±0.5 GU (0.0–99.9 GU), ±0.5% of reading (100–2000 GU) |
| Data Storage | 999 measurements with timestamp |
| Standard Memory | 50 reference standards |
| Measurement Speed | 0.5 s per reading |
| Power Source | 1.5 V AA (R6) alkaline batteries (approx. 10,000 measurements) |
| Auto Power-Off | Adjustable 10–99 s |
| Operating Environment | 15–40 °C, ≤85% RH (non-condensing at ≤35 °C) |
| Storage Conditions | −10–60 °C, ≤85% RH (non-condensing at ≤35 °C) |
| Dimensions | 155 × 73 × 48 mm |
| Weight | 400 g |
| Interface | RS-232C |
| Supported Languages | English, Spanish, German, French, Italian, Japanese |
| Software | GlossLink data exchange software |