Leica
Filter
Showing 331–360 of 394 results
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | RM2235 |
| Max Sample Size | 45 × 50 mm |
| Section Thickness Range | 1–60 µm |
| Minimum Increment | 1 µm |
| Vertical Stroke | 70 mm |
| Specimen Retraction | 200 µm |
| Horizontal Translation | 30 mm |
| Roughing Steps | 10 µm / 50 µm |
| Dimensions (W×D×H) | 490 × 520 × 305 mm |
| Weight | 37 kg |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | RM2245 |
| Feed Mechanism | Stepper Motor-Driven |
| Vertical Stroke | 70 mm |
| Handwheel Mode Options | Full-Rotation Manual / Short-Stroke “Half-Cut” Mode |
| Optional Precision Stage | 8° X/Y Micrometer Stage with Zero-Reference Calibration Marks |
| Handwheel Counterbalance System | Patented Adjustable Counterbalance |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | RM2255 |
| Maximum Sample Size | 50 × 60 × 40 mm |
| Section Thickness Range | 0.5–100 µm |
| Section Increment | 5 µm |
| Vertical Travel | 70 mm |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | RM2265 |
| Cutting Stroke | 70 mm |
| Compatible Blades | Glass (triangular or Ralph) and Diamond knives |
| Optional Cryo Integration | Compatible with Leica LN22 Liquid Nitrogen Cryo-Attachment for ultra-low temperature sectioning down to −150 °C |
| Compliance | Designed and manufactured in accordance with ISO 13485 and CE medical device directives (Class I) |
| Software Control | Integrated programmable microprocessor with memory for user-defined protocols |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Leica Rotatable Beamsplitter |
| Component Category | Optical Beam Steering Assembly |
| Compatibility | Leica M620, M820, M525 F20, M525 F40 Surgical Microscopes |
| Intended Use | Dual-observer surgical visualization and rapid optical path switching |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Leica RUV800 |
| Pricing | Upon Request |
| Brand | Leica |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Leica S APO Stereo Microscope for Routine Inspection |
| Pricing | Available Upon Request |
| Brand | Leica |
|---|---|
| Model | S4E |
| Optical System | Greenough |
| Zoom Ratio | 4.8:1 |
| Magnification (Standard) | 6.3×–30× |
| Field of View Diameter | 36.5 mm |
| Working Distance (Standard) | 110 mm |
| Eyepiece Angle | 38° |
| Numerical Aperture (Max) | 0.124 |
| Resolution (Max) | 372 lp/mm |
| ESD Protection | Surface Resistivity 2×10¹¹ Ω/sq, Discharge Time <2 s (1000 V → 100 V) |
| Interpupillary Distance | 55–75 mm |
| Eyepieces | 10×/23, 16×/16, 20×/12, 25×/9.5, 40×/6 |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | S6E |
| Zoom Ratio | 6.3:1 |
| Magnification Range | 6.3×–40× |
| Field of View Diameter | 36.5 mm |
| Working Distance (standard) | 110 mm |
| Viewing Angle | 38° |
| Eyepiece Options | 10×/23, 16×/16, 20×/12, 25×/9.5, 40×/6 |
| Interpupillary Distance Adjustment | 55–75 mm |
| Objective Types | Achromatic (0.32×, 0.5×, 0.63×, 0.75×, 1.6×, 2.0×) |
| Numerical Aperture (max) | 0.144 |
| Resolution (max) | 432 lp/mm |
| ESD Protection | Surface resistivity 2×10¹¹ Ω/sq, discharge time <2 s (1000 V → 100 V) |
| Optical Design | Greenough-type, lead-free optics |
| Video/Photo Port | Coaxial output, switchable |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | S6 |
| Zoom Ratio | 6.3:1 |
| Magnification Range | 6.3× to 40× |
| Viewing Angle | 60° (S6 standard), 38° (S6 E variant) |
| Working Distance | 110 mm |
| Eyepiece Field of View | 23 mm (with 10× eyepieces), up to 36.5 mm maximum |
| Electrostatic Dissipation | 10⁶ Ω/square (S6 T variant) |
| Imaging Interface | 100% photo/video port with 100% light path toggle (S6 D variant) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | S8 APO |
| Zoom Ratio | 8:1 |
| Magnification Range | 10×–80× |
| Viewing Angle | 38° |
| Eyepiece | 10× widefield |
| Objective | 1× apochromatic (APO) |
| Resolution (max) | 300 lp/mm at 80× |
| Resolution (2× objective option) | up to 600 lp/mm |
| Working Distance | 75 mm |
| Imaging Interface | C-mount |
| Optical Design | Greenough stereoscopic principle |
| Color Correction | Apochromatic (APO) light path |
| Photo/Video Path | 100% light split for simultaneous imaging and observation |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | S9i |
| Integrated Camera | 10 MP CMOS |
| Connectivity | Gigabit Ethernet |
| Real-time Frame Rate | up to 35 fps |
| Image Output | HD video and still images |
| Network Integration | Compatible with standard industrial LAN infrastructure |
| Software Compatibility | Leica Application Suite (LAS) X |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | SCN400 |
| Automation | Integrated SL801 384-slide autoloader |
| Max Magnification | 40× |
| Avg. Scan Time (20×) | 100 s per slide |
| Focusing Technology | Patented Dynamic Focus Tracking |
| Software Platform | Leica SCN400 Client |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Leica SD AF |
| Configuration | Import (OEM-manufactured in Germany) |
| Software Platform | Leica MM AF |
| Core Technology | Yokogawa CSU-X1 Spinning Disk Unit Integrated with Leica Optical Path and Adaptive Focus Control |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | SFL100 |
| Excitation Wavelength | 470 nm (standard), optional wavelengths available |
| LED Lifetime | ≥10,000 hours |
| Design | Compact, integrated, alignment-free illumination module |
| Power Control | Continuous, analog intensity adjustment |
| Compliance | CE, RoHS, IEC 61000-6-3 |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Leica SFL4000 |
| LED Channels | 5 independent high-power LEDs |
| LED Lifetime | ≥10,000 hours |
| Control Interface | Integrated capacitive touchscreen |
| Output Stability | <1% intensity drift over 8 h |
| Spectral Range | 365–770 nm (configurable via modular LED selection) |
| Compatibility | Designed for Leica DMi8, DM6 B, and DM6000 B inverted & upright microscopes |
| Regulatory Compliance | CE, IEC 61000-6-3, IEC 62471 (Photobiological Safety Class 1) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Leica SFL7000 |
| Pricing | Upon Request |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Leica SR GSD 3D |
| Imaging Principle | Ground-State Depletion (GSD) / direct Stochastic Optical Reconstruction Microscopy (dSTORM) |
| Lateral Resolution | ≤20 nm |
| Axial Resolution | ≤50 nm |
| Optical Configuration | Automated Total Internal Reflection Fluorescence (TIRF) |
| Objective Correction | Apochromatic |
| Calibration Options | Gold nanoparticle reference, fluorescent bead-based, dye-specific spectral calibration |
| Software | Leica GSD 3D Acquisition & Analysis Suite (compliant with GLP audit trails and ISO/IEC 17025 traceability workflows) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Leica SR GSD |
| Laser Wavelengths | 405 nm, 488 nm, 532 nm, 642 nm |
| Laser Power | 300–1000 mW per line |
| Lateral Drift Stability | <20 nm / 10 min (SuMo Piezo Stage) |
| Resolution (GSDIM mode) | ≤20 nm (lateral) |
| Compatible Fluorophores | Alexa Fluor® 488/532/546/647, Rhodamine-6G, Atto 488/532/565/568, YFP, EYFP |
| Imaging Modes | Widefield, TIRF, High-Speed Multichannel Fluorescence, Temperature-Controlled Live-Cell Imaging |
| Base Platform | Leica DMI6000 B Inverted Microscope with AM TIRF MC System |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | ST5010-CV5030 |
| Automation Level | Fully Automatic |
| Instrument Type | Rotary (Carousel-Based) |
| Throughput Capacity | 3 Slide Racks per Load |
| Design Integration | Seamless Interface with Leica Autostainer XL |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | ST5020 |
| Automation Level | Fully Automatic |
| Instrument Type | Rotary Stainer |
| Stations | 40 (incl. up to 4 optional oven stations and up to 6 rinse stations) |
| Water Savings | Up to 80% |
| Integrated Workflow | Compatible with Leica TS5025 Transfer Station and Leica CV5030 Coverslipper |
| Display | Corrosion-resistant large-color touchscreen |
| Rack Recognition | Leica Code-Rack™ RFID-based programmable rack identification system |
| Compliance | Designed for ISO 15189, CLIA, CAP, and GLP/GMP-aligned pathology laboratory environments |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Steel Expert 2.0 |
| Price Range | USD 68,000 – 136,000 (based on configuration) |
| Microscope Type | Upright |
| Total Magnification | 1000× |
| Eyepiece | 10× |
| Objective | 100× |
| Compliance Standards | ASTM E45-11, ISO 4967:2013, EN 10247:2013 (Draft), DIN 50602 |
| Software Architecture | Modular, Standalone or Integrated with Leica DM Series Microscopes |
| Deployment | Windows-based, FDA 21 CFR Part 11–ready audit trail optional |
| Batch Processing | Yes |
| Multi-Standard Parallel Reporting | Yes |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | STELLARIS 8 DIVE |
| Instrument Type | Point-Scanning Confocal Microscope |
| Excitation Range | Up to 1300 nm |
| Detection Range | 380–800 nm (tunable via 4Tune spectral detector) |
| Core Technology | Tunable non-descanned spectral detection with variable beam expander (VBE) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | STELLARIS 8 FALCON |
| Imaging Modality | Time-Correlated Single-Photon Counting (TCSPC)-based Fluorescence Lifetime Imaging (FLIM) |
| Frame Rate | Up to 4 fps at 256 × 256 pixels |
| Spectral Channels | Simultaneous acquisition across up to 4 spectral detection channels or sequential acquisition across up to 10 channels |
| FLIM Analysis Modes | Biexponential decay fitting, phasor plot analysis, spectral-FLIM unmixing |
| Software Integration | Fully embedded in Leica LAS X NAVIGATOR and LAS X LITE platforms |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Instrument Type | Point-Scanning Confocal Microscope |
| Model | STELLARIS |
| Detection Range | 410–850 nm |
| Excitation Source | White Light Laser (WLL), up to 8 simultaneous spectral lines |
| Detector Technology | Power HyD hybrid detectors |
| Core Capabilities | Fluorescence Lifetime Imaging (FLIM), TauSense-based functional contrast, AI-driven rare-event detection (Aivia), 3D optical sectioning, multi-modal integration (STED, DIVE, DLS, FALCON, CARS) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | STELLARIS CRS |
| Instrument Type | Point-Scanning Confocal Microscope |
| Excitation | Near-Infrared (NIR) Lasers |
| Imaging Modalities | Stimulated Raman Scattering (SRS), Coherent Anti-Stokes Raman Scattering (CARS), Multiphoton Fluorescence, Second Harmonic Generation (SHG), FLIM |
| Spatial Resolution | Subcellular (≤ 300 nm lateral, ≤ 1 µm axial) |
| Detection | Spectral Unmixing, TauSense Lifetime-Gated Acquisition |
| Software Platform | LAS X with ImageCompass Interface |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | STELLARIS Cryo |
| Application Domain | Cryo-Correlative Light and Electron Microscopy (Cryo-CLEM) |
| Cooling Stage | Integrated Liquid Nitrogen–Cooled Stage with Transfer Shuttle |
| Software Platform | LAS X Coral Cryo (with TauSense, LIGHTNING, and Interpolated 3D Targeting) |
| Objective Lens | HC PL APO 50×/0.90 Cryo-Optimized Dry Objective |
| Detection System | Power HyD Hybrid Detectors |
| Light Source | White Light Laser (WLL, 470–670 nm) |
| Imaging Modes | Confocal Reflectance, Fluorescence, TauContrast, TauSeparation, Spectral Unmixing |
| Ice Thickness Assessment | Dual-mode (Overview + Confocal Reflectance Z-Stack) |
| Data Format | Open, Metadata-Rich TIFF & HDF5 (CF-1 compliant) |
| Regulatory Alignment | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | STELLARIS DLS |
| Instrument Type | Point-Scanning Confocal Microscope with Integrated Digital Light Sheet Module |
| Integration Compatibility | STELLARIS 5 and STELLARIS 8 platforms |
| Optical Architecture | Inverted microscope with vertical dual-axis light sheet generation via TwinFlect mirror system |
| Illumination | Scanned Gaussian or top-hat light sheet (405–785 nm excitation range) |
| Detection | Dual sCMOS cameras (optional high-speed or high-sensitivity configuration) |
| Sample Mounting | Standard glass-bottom dishes, U-shaped capillaries, FEP tubing, or custom mounting frames (24 × 50 mm rectangular / Ø30 mm circular) |
| Refractive Index Matching | Compatible with water, glycerol, BABB, Scale, CUBIC, and other clearing media |
| Software Platform | LAS X LightSheet Wizard with real-time fusion, environmental control module, 3D Visualization, and GLP-compliant audit trail (21 CFR Part 11 ready) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Instrument Type | Point-Scanning Confocal Microscope |
| Model | STELLARIS SpectraPlex |
| Spectral Unmixing Capacity | >15 fluorophores per acquisition |
| Workflow Integration | Aivia AI-powered analysis platform |
| Compliance | Designed for GLP/GMP-aligned spatial biology workflows, compatible with ISO 13485–informed documentation practices |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | Leica STELLARIS STED |
| Instrument Type | Point-Scanning Confocal Microscope |
| STED Laser Wavelengths | 592 nm, 660 nm, 775 nm |
| Excitation Range | 440–790 nm (White Light Laser) |
| Detection | Up to 5 spectral Power HyD detectors (HyD S/X/R), 1.5 ns system dead time |
| Objective Support | STED-optimized STED WHITE 100× oil, 93× glycerol (motCORR), 86× water (motCORR) |
| Resolution | <30 nm lateral, <100 nm axial (sample- and fluorophore-dependent) |
| Core Technology | Time-gated STED (TauSTED Xtend), TauSense-enabled lifetime discrimination, FLIM-capable with FALCON module |
| Software Platform | LAS X with ImageCompass, LAS X Navigator, TauSense tools |