Leica
Filter
Showing 361–390 of 394 results
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | STELLARIS STED |
| Excitation Wavelength Range | 440–790 nm (White Light Laser) |
| STED Depletion Wavelengths | 592 nm, 660 nm, 775 nm |
| Spatial Resolution | <30 nm (lateral), <100 nm (axial), sample- and fluorophore-dependent |
| Detection | Up to 5 spectral Power HyD detectors with 1.5 ns system dead time |
| Objective Options | STED WHITE 100× oil, 93× glycerol (motCORR), 86× water (motCORR) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Swingarm Stands |
| Type | Modular Counterbalanced Stereo Microscope Support System |
| Compliance | Designed for ISO 13715 (Ergonomics of Visual Display Terminals) and DIN EN 61326-1 (EMC for Laboratory Equipment) |
| Vibration Damping | Up to 50% reduction vs. standard rigid feet |
| Motion Mechanism | Rack-and-pinion vertical adjustment (heavy-duty variant), precision ball-bearing horizontal arm |
| Lubrication-Free Vertical Guidance | Yes |
| Mounting Interface | Standard M6/M8 threaded holes, compatible with Leica Z6/Z16/Z30 stereo microscope bodies and third-party C-mount adapters |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 CARS |
| Laser Modalities | Visible, UV, IR, SHG, CARS |
| Imaging Modes | Single-photon fluorescence, multiphoton fluorescence, CARS, SHG, spectral unmixing |
| Scan Systems | Dual scanning architecture (standard resonant + high-speed resonant/galvo) |
| Software Platform | LAS X (successor to LAS AF), FDA 21 CFR Part 11 compliant modules available |
| Compliance | ISO 13485–certified manufacturing, CE-marked, GLP/GMP-ready audit trail support |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 DLS |
| Imaging Principle | Orthogonal light-sheet illumination integrated with confocal detection |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 |
| Type | Laser Scanning Confocal Microscope |
| Optical Architecture | Upright or Inverted Configurable Platform |
| Detection Principle | Point-scanning confocal fluorescence imaging with spectral detection and time-gated photon counting capability |
| Maximum Frame Rate | 428 fps (at 512 × 32 resolution) |
| Field of View | Up to 22 mm diagonal (with resonant scanner and wide-field optics) |
| Scan Modes | Galvoscanner, Resonant Scanner, Galvoflow (combined galvo-resonant hybrid mode for accelerated Z-stack acquisition) |
| Detector Options | Hybrid Detectors (HyD), PMTs, Spectral Detectors (Tuneable Bandpass or Linear Unmixing) |
| Excitation Sources | Integrated white-light laser (WLL, 470–670 nm), optional UV/IR lasers, acousto-optic tunable filters (AOTF) |
| Software Platform | LAS X (v3.7+), compliant with FDA 21 CFR Part 11 audit trail and electronic signature modules |
| Compliance | CE, IEC 61000-6-3, ISO 13485 (for medical device configurations), GLP/GMP-ready metadata logging |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 MP |
| Instrument Type | Point-Scanning Multiphoton Confocal Microscope |
| Excitation Range | 680–1300 nm |
| Maximum IR Wavelength | 1300 nm |
| Resonant Scanner Speed | 8 kHz / 12 kHz |
| Field of View (FOV) | up to 22 mm |
| Detection | Leica HyD NDD & HyD RLD non-descanned detectors |
| Objective Correction | motCORR electrically adjustable correction collar |
| Specialized Objectives | HC IRAPO L 25×/1.00 W motCORR, HC FLUOTAR L 25×/1.00 IMM (ne=1.457) motCORR VISIR, APO HCX L20×/0.95 IMM for BABB immersion (ne=1.559) |
| Software Platform | LAS X with integrated multiphoton control, FLIM wizard, and STED/FLIM/SMD module compatibility |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 SMD |
| Application Domain | Single-Molecule Detection (SMD), Fluorescence Correlation Spectroscopy (FCS), Fluorescence Cross-Correlation Spectroscopy (FCCS), Fluorescence Lifetime Imaging Microscopy (FLIM), Fluorescence Lifetime Correlation Spectroscopy (FLCS) |
| Integrated Hardware Platform | PicoQuant MD-series detection modules and timing electronics |
| Software Integration | PicoQuant SymPhoTime 64 (SMD-optimized edition) |
| Optical Architecture | Inverted confocal platform with tunable white-light laser (WLL), spectral detection (HyD detectors), and time-correlated single-photon counting (TCSPC) capability |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 X |
| Excitation Source | Tunable White Light Laser (WLL), Pulsed |
| Detection Channels | Up to 5 Spectral Detection Channels |
| Excitation Lines | Up to 8 Simultaneous Lines |
| FLIM Compatibility | Yes, with Adjustable Repetition Rate via Pulse Picker |
| LightGate Technology | Time-Gated Spectral Detection |
| Spectral Resolution | Continuous Excitation & Emission Acquisition (Excitation–Emission Matrix Mapping) |
| Application Scope | Live-Cell Imaging, Multicolor Fluorescence, Spectral Unmixing, FLIM, pH/Binding Microenvironment Analysis |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 X |
| Excitation Source | Tunable White Light Laser (WLL), Pulsed |
| Detection | Spectral Detection with Adjustable Bandpass, Up to 8 Simultaneous Excitation Lines |
| Fluorescence Lifetime Imaging (FLIM) Capability | Yes |
| Scan Mode | Galvo + Resonant Scanner |
| Zoom Optics | Continuous Spectral Zoom (λ-Zoom) |
| Microscope Frame | Inverted or Upright Configurable Platform |
| Vibration Isolation | Compatible with Active Damping Optical Tables |
| Software | LAS X Professional Suite with Spectral Unmixing, FLIM Analysis, and GLP-Compliant Audit Trail Modules |
| Compliance | Designed for ISO 13485-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SPE (Spectral Point-Scanning Confocal System) |
| Laser Lines | 405 nm (optional), 488 nm, 532 nm, 635 nm (solid-state lasers) |
| Detection | High-dynamic-range PMTs |
| Software | Leica LAS AF |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Dimensions | Compact benchtop footprint (< 600 × 500 × 450 mm) |
| Application Focus | Live-cell imaging, fixed-tissue fluorescence microscopy, spectral unmixing, multi-label quantification |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | THUNDER Imager 3D Live Cell |
| Core Technology | Computational Clearing (real-time deconvolution for widefield fluorescence) |
| Imaging Modality | High-sensitivity widefield fluorescence microscopy with integrated environmental control |
| Camera | DFC9000 GTC sCMOS (QE up to 82%) |
| Illumination | Multi-line high-intensity LED source with narrow excitation bandwidths |
| Stage | Quantum motorized stage (≤ ±0.25 µm reproducibility |
| Focus Control | Adaptive Focus Control (AFC) + closed-loop Z-drive (20 nm repeatability) |
| Throughput | Up to 90 fps full-frame acquisition |
| Z-stack Speed | 150-layer stack in <60 s |
| Environmental Chamber | Integrated CO₂, temperature & humidity control with micro-humidifier for long-term live imaging |
| Software Platform | LAS X (GLP-compliant, audit trail enabled, FDA 21 CFR Part 11 ready) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | THUNDER Imager Cell Spinning Disk System |
| Category | Spinning Disk Confocal Microscopy Platform for 3D Live-Cell and Thick-Tissue Imaging |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | THUNDER |
| Imaging Principle | Widefield Fluorescence with Real-Time Computational Clearing |
| Compliance | ISO/IEC 2382:2015 (Information Technology — Vocabulary), GLP/GMP-Ready Data Integrity Architecture |
| Software Platform | Leica Application Suite X (LAS X) v4.13+ |
| Data Handling | Native Support for TIFF, OME-TIFF, HDF5 |
| Regulatory Context | Designed for 21 CFR Part 11–compliant environments with optional audit trail and electronic signature modules |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Instrument Type | Research-Grade Inverted/ Upright Integrated Fluorescence Microscope |
| Excitation Source | High-Power LED |
| Configuration | Fully Automated Whole-Organism Imaging Platform with Computational Clearing |
| Optical Architecture | Stereo + Epifluorescence + Z-stack Acquisition Engine |
| Compliance | Designed for ISO/IEC 2382:2015-compliant image clarity and structural fidelity in biological imaging |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | THUNDER Imager Tissue |
| Instrument Type | Upright/Inverted Hybrid Fluorescence Microscope |
| Excitation Source | High-Power LED Illumination |
| Classification | Research-Grade Widefield Fluorescence Microscope |
| Key Technology | Computational Clearing (Real-Time Deconvolution) |
| Optical Architecture | Optimized for 3D Tissue Imaging (up to 200 µm depth) |
| Software Platform | LAS X Navigator with Integrated THUNDER Engine |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TL3000 Ergo and TL5000 Ergo |
| Numerical Aperture (NA) | 0.73 (TL3000 Ergo), 0.9 (TL5000 Ergo) |
| Illumination | High-stability white LED |
| Contrast Modes | Brightfield, Rottermann Contrast, Unilateral or Bilateral Darkfield |
| Field Diameter | 65 mm |
| Cooling | Passive (max. +6°C above ambient) |
| Software Integration | Fully encoded |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TL3000 ST |
| Illumination Type | Halogen Transmitted Light |
| Optical Design | Multi-layer Coated Optics |
| Contrast Control | Adjustable Sliding Mirror |
| Vibration Damping | Integrated Anti-Vibration Pads |
| Working Area | Large Format Stage Platform |
| Color Temperature Enhancement | Built-in Daylight Simulation (No External Filter Required) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TL4000 BFDF |
| Illumination Modes | Brightfield & Darkfield |
| Working Area | Large Format (≥150 × 120 mm) |
| Vibration Damping | Integrated Anti-Vibration Elastomeric Feet |
| Optional Stage | Motorized or Manual XY Slide-on Stage with Focusing Compatibility |
| Compliance | CE, ISO 9001 Manufacturing Environment |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TL4000 RC |
| Illumination Technology | Rottermann Contrast (RC) |
| Optical Compatibility | Designed for Leica M-series and Z-series stereo microscopes |
| Mechanical Stage Integration | Slide-on XY mechanical stage with focus-synchronized movement |
| Vibration Damping | Integrated high-performance anti-vibration pads |
| Regulatory Compliance | CE-marked, compliant with IEC 61000-6-3 (EMC) and IEC 61000-6-2 (immunity) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TL4000 RCI |
| Illumination Technology | Rottermann Contrast (localized differential interference contrast via oblique transmitted lighting) |
| Interface | Dual USB 2.0 for brightness control and device communication |
| Mirror Options | Adjustable planar and concave reflectors for dynamic positive/negative relief contrast |
| Stage Integration | Slide-on mechanical stage compatible with transmitted-light focusing |
| Color Temperature Management | Constant Color Intensity Control (CCIC) — intensity adjustment without white balance recalibration |
| Vibration Damping | Integrated elastomeric anti-vibration feet |
| Remote Operation | Software-controllable illumination, automated image acquisition, and time-lapse sequencing |
| Compliance | Designed for integration into Leica Z6 APO, M205 FA, and other modular stereo microscope systems per DIN EN ISO 9001 manufacturing standards |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TL5000 Ergo |
| Illumination Type | High-Uniformity White LED |
| Field Diameter | 65 mm |
| Contrast Modes | Optimized Rottermann Contrast, Low-Reflection Darkfield, Uniform Brightfield |
| Automation | Motorized Aperture Synchronized with Zoom Position |
| Software Integration | Fully Encoded & Compatible with Leica LAS / LAS AF |
| Ergonomic Design | Flat, Low-Profile Platform for Fatigue-Free Operation |
| Compliance | Designed for GLP/GMP-Lab Environments, Supports Audit-Trail-Capable Workflow in LAS AF |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Leica ToricEyePiece |
| Type | Rotatable Precision Eyepiece with Integrated Toric Axis Scale |
| Compliance | CE-marked, ISO 13485–certified manufacturing environment |
| Intended Use | Intraoperative alignment of toric intraocular lenses (IOLs) during cataract surgery |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | UC Enuity |
| Type | Ultramicrotome for Electron Microscopy Sample Preparation |
| Temperature Control | Integrated Cryo Chamber with Precise Thermal Regulation (Room Temp to −160 °C) |
| Automation | Auto-alignment of Block Face and Knife, Automated Trimming, Fluorescence-Guided Targeting |
| Compatibility | Diamond/Knife Knives, Glass Knives, Silicon Wafers & EM Grids |
| Ergonomics | Fully Adjustable Stereo Microscope Height & Angle, Padded Arm Supports, UV-Blocking Safety Shield |
| Connectivity | RemoteCare™ Diagnostic Platform with Real-time Parameter Monitoring & Error Code Reporting |
| Compliance | Designed for GLP/GMP-adjacent workflows |
| Brand | Leica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Visoria B |
| Pricing | Upon Request |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Visoria B |
| Type | Digital Biological Microscope |
| Compliance | CE, ISO 13485 (Medical Device Quality Management), IEC 61000-6-3 (EMC), IEC 62304 (Software Lifecycle) |
| Ergonomic Design | EN 614-1 / ISO 9241-5 Certified |
| Imaging Interface | Integrated HDMI & USB-C Output |
| Software Platform | Leica Enersight v3.2 (FDA 21 CFR Part 11–Ready Audit Trail, GLP/GMP-Compatible Metadata Logging) |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | Visoria M |
| Optical Configuration | Encoded, Motorized Illumination Control |
| Observation Modes | Brightfield, Darkfield, Polarized Light, Differential Interference Contrast (DIC), Oblique Illumination, Fluorescence (optional) |
| Macro Objective | Optional 0.7× Objective (FOV ≈ 36 mm) |
| Software Platform | Enersight |
| Compliance | Designed for ISO/IEC 17025-compliant labs, supports audit-trail–enabled workflows per GLP/GMP requirements |
| Imaging Interface | Integrated tablet display (no PC required), HDMI output |
| Ergonomics | Adjustable height stand, tilting monitor arm, low-fatigue observation posture |
| Brand | Leica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Upright |
| Imaging Analysis System | Integrated Enersight Software Platform |
| Observation Modes | Brightfield, Darkfield, Polarization, Differential Interference Contrast (DIC), Oblique Illumination, Fluorescence |
| Macro Objective Option | 0.7× |
| Ergonomic Design | Yes |
| Digital-Only Operation | Supports tablet-based, eyepiece-free imaging |
| Illumination Control | Encoded, Auto-Adaptive Brightness Management |
| Image Processing Features | Extended Depth of Field (EDOF), Flat-Field Illumination Correction, Multi-Mode Image Fusion (e.g., BF + DF), XY Tile Scan with Manual Stage |
| Brand | Leica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Visoria P |
| Pricing | Upon Request |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Visoria P |
| Category | Imported Instrument |
| Distribution Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | Viventis Deep |
| Light Sheet Technology | Dual-side illumination with scanned Gaussian light sheet |
| Imaging Resolution | 406 nm (with 16× objective), 260 nm (with 25× objective) |
| Field of View | 900 µm (16×), 596 µm (25×) |
| Maximum Sample Size | >50 mm |
| Laser Wavelengths | 405 nm, 488 nm, 561 nm, 638 nm |
| Objective Lenses | 16× and 25× high-NA water-dipping objectives |
| Illumination Mode | Dual-side illumination |