| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FDCS196 with Image Station |
| Microscope Type | Upright Biological Microscope |
| Eyepiece Configuration | Binocular |
| Temperature Range | −195 °C to +125 °C |
| Vacuum Range | down to 10⁻³ mbar |
| Temperature Stability & Accuracy | ±0.01 °C (with 100 Ω Pt sensor, ±0.1 °C absolute accuracy) |
| Heating/Cooling Rate | up to 150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample X–Y Translation Range | 16 mm |
| Heating Stage Surface Area | 22 mm diameter |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Cooling Method | Direct cryogen (e.g., liquid nitrogen) cooling of high-conductivity silver heating block |
| Illumination Path | C-mount-compatible transmitted-light optical train |
| Vacuum Monitoring | Pirani gauge integrated |
| Compliance | ISO 9001-certified service and training support |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | BCS196 |
| Temperature Range | –196 °C to +125 °C |
| Temperature Stability & Accuracy | ±0.01 °C |
| Optical Aperture Diameter | 1.3 mm |
| Sample X–Y Travel | 16 mm |
| Active Sample Area | 22 mm |
| Quenching Rate | Up to 5000 °C/min |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Window Thickness | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.7 mm |
| Dimensions | 135 × 92 × 22.1 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CAP500 |
| Temperature Range | −180 °C to +500 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | <0.1 °C |
| Heating/Cooling Rate | 1–50 °C/min |
| Sample X-Axis Translation | 20 mm |
| Quartz Window Aperture | 22 mm long × 1.6 mm diameter groove for capillary insertion |
| Minimum Working Distance | Objective 4.5 mm / Condenser 12.5 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CCR1000 |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | 1–130 °C/min |
| Temperature Stability | ±1 °C |
| Maximum Pressure | 5 bar (with quartz window) |
| Sample Diameter | 7 mm |
| Sample Mass | 70–100 mg |
| Gas Inlet | 1/16″ stainless steel high-pressure tubing |
| Working Distance for Objective Lens | 6 mm |
| Window Compatibility | Reflectance microscopy, Raman spectroscopy, FTIR |
| Cooling | Integrated water-cooled jacket |
| Construction Materials | Non-reactive ceramics, inert ceramic fiber filter, quartz or sapphire optical windows |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CMS196 |
| Temperature Range | Ambient to –196 °C |
| EM Grid Compatibility | Standard TEM grids, Bessy, Planchette, FEI, Polara formats |
| Motorized XY Stage Resolution | 1 µm |
| Liquid Nitrogen Hold Time | 30 min (standard Dewar) / 6 h (optional 3 L Dewar) |
| Integrated Condenser | For transmitted light and phase contrast |
| Sample Capacity | Up to 3 magnetic sample carriers |
| Startup Time | ≤10 min |
| Drift Performance | <1 nm/min (under stable conditions) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CMS196 |
| Temperature Range | Ambient to −196 °C |
| EM Grid Compatibility | Standard TEM grids, Bessy, Planchette, FEI, Polara formats |
| Motorized XY Stage Resolution | 1 µm |
| Integrated Condenser | For transmitted light and phase contrast |
| LN₂ Hold Time | 30 min (standard Dewar) / 6 h (optional 3 L Dewar) |
| Startup Time | ≤10 min |
| Sample Drift | <1 nm over 10 min |
| Stage Architecture | Decoupled sample holder–Dewar mechanical interface |
| Automation | Magnetic sample cartridge auto-alignment system (up to 3 samples) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CSS450 |
| Temperature Range | −50 °C to 450 °C |
| Temperature Accuracy & Stability | ±0.1 °C |
| Optical Aperture Diameter | 2.5 mm |
| Sample Heating Area | 30 mm |
| Max. Heating/Cooling Rate | 30 °C/min |
| Minimum Objective/Condenser Working Distance | 7.4 mm / 11.5 mm |
| Shear Modes | Oscillatory, Steady, Step |
| Shear Rate Range | 0.003–7500 s⁻¹ |
| Gap Control Range | 5–2500 µm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | DSC600 |
| Temperature Range | −196 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | up to 130 °C/min |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FDCS196 |
| Temperature Range | –196 °C to +125 °C (with LN₂ cooling pump) |
| Heating Rate | Up to 150 °C/min |
| Temperature Stability | < 0.1 °C |
| Sensor | 100 Ω Platinum RTD |
| Vacuum Level | Down to 10⁻³ mbar |
| Sample Area | Ø22 mm |
| XY Manipulation Range | 15 mm |
| Window Thickness | 0.5 mm (single ultra-thin optical window) |
| Sample Volume | As low as 5 µL |
| Compatible With | Polarized light, phase contrast, confocal microscopy, Raman spectroscopy, FTIR, and X-ray imaging |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FTIR600 |
| Temperature Range | −196 °C to 600 °C |
| Temperature Stability | < 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Optical Aperture Diameter | 2.4 mm |
| Sample X–Y Translation Range | 16 mm |
| Heating Area | 22 mm² |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Window Thickness (CaF₂) | 0.17 mm |
| Condenser Angle | 85° |
| Objective Angle | 116° |
| Minimum Working Distance (Objective/Condenser) | 4.5 mm / 12.5 mm |
| Chamber | Sealed, Gas-Purged Compatible |
| Dimensions (L×W×H) | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTS420 |
| Temperature Range | −196 °C to 420 °C (liquid nitrogen cooling optional) |
| Temperature Stability | < 0.1 °C |
| Max Ramp Rate | 0.1–50 °C/min |
| Sample Area | 53.5 × 43 mm |
| XY Translation | 15 × 15 mm |
| Optical Aperture | 2.5 mm |
| Minimum Objective Working Distance | 6 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Dimensions (Stage Only) | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTS420 |
| Temperature Range | −196 °C to +420 °C (liquid nitrogen required for sub-ambient operation) |
| Stage Dimensions | 160 × 80 × 24 mm |
| Sample Area | 53.5 × 43 mm |
| X–Y Translation Range | 15 × 15 mm |
| Standard Slide Holder | 76 × 26 mm |
| Optical Aperture | 2.5 mm diameter |
| Temperature Stability | < ±0.1 °C at isothermal conditions |
| Heating/Cooling Rate | 0.1–50 °C/min (controller-dependent) |
| Sensor | 100 Ω Platinum RTD |
| Environmental Control | Sealed chamber with gas inlet/outlet valves (inert atmosphere or humidity control) |
| Optical Configuration | Compatible with transmitted and reflected light microscopy |
| Electrode Integration | Optional internal electrodes for electric field application or signal measurement (LCD cell-ready configuration) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTS420E-P |
| Temperature Range | Ambient to +420 °C (with optional cryogenic cooling to −196 °C) |
| Electrode Configuration | Integrated dual-electrode system |
| Temperature Control Accuracy | ±0.01 °C |
| Temperature Stability | <0.01 °C |
| Optical Aperture Diameter | 2.4 mm |
| Sample Translation Range (X–Y) | 15 × 15 mm |
| Active Sample Area | 53.5 × 43 mm |
| Compatible Substrates | Standard 76 × 26 mm microscope slides or φ16 mm coverslips |
| Heating Rate | 0.1–50 °C/min |
| Minimum Working Distance (Objective/Condenser) | 6.0 mm / 13.2 mm |
| Stage Dimensions | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTSE420 |
| Temperature Range | Ambient to +420 °C (with optional cryo-cooling: down to −196 °C) |
| Temperature Stability | <0.01 °C |
| Temperature Resolution | 0.01 °C |
| Electrode Configuration | Standard dual-electrode |
| Optical Aperture | Ø2.4 mm |
| Sample XY Translation | 15 × 15 mm |
| Stage Surface Area | 53.5 × 43 mm |
| Compatible Sample Holders | Standard 76 × 26 mm microscope slides or Ø16 mm coverslips |
| Heating Rate | 0.1–50 °C/min |
| Minimum Objective Working Distance | 6.0 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Stage Dimensions | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | MDSG600 |
| Temperature Range | −196 °C to +600 °C |
| Heating/Cooling Rate Control | 0.01–150 °C/min |
| Position Resolution | 0.05 µm |
| Position Repeatability | <3 µm |
| XY Travel Range | 15 mm × 15 mm |
| Stored Coordinates | 150 (X,Y) |
| Aperture Diameter | 1.3 mm |
| Objective Working Distance Compatibility | 0.1–4.9 mm |
| Condenser Minimum Working Distance | 12.7 mm |
| Sample Holders | 7 mm, 10 mm, or 16 mm diameter |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | MFS |
| Force Range | 0–20 N / 0–200 N |
| Force Resolution | 0.0001 N (20 N range), 0.001 N (200 N range) |
| Displacement Resolution | 1 µm |
| Maximum Travel | 85 mm |
| Speed Range | 0.1–5000 µm/s |
| Temperature Range | −196 °C to +600 °C |
| Environmental Control | Vacuum, inert gas, or humidity-controlled (with RH95 module) |
| Optical Compatibility | Transmission/reflection light, X-ray, Raman, FTIR |
| Electrical Measurement Option | Conductive fixtures available |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | MFS350 |
| Temperature Range | −195 °C to 350 °C |
| Sample Width | 0.001–22 mm |
| Sample Thickness | 0.001–2 mm |
| Minimum Sample Length | 26 mm |
| Tensile Speed | 1–5000 µm/s |
| Force Range | 0.01–20 N or 0.1–200 N |
| Force Resolution | 0.01 N or 0.1 N |
| Maximum Travel | 85 mm |
| Position Resolution | 1 µm |
| Objective Working Distance | 7.5 mm |
| Condenser Working Distance | 12.5 mm |
| Temperature Ramp Rate | 0.1–60 °C/min |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | PE100 |
| Temperature Range | −5 °C to 99 °C |
| Ramp Rate | ±10 °C/min |
| Temperature Accuracy & Stability | ±0.1 °C (full range) |
| Viewing Aperture Diameter | 16 mm |
| Sample Area Diameter | 108 mm |
| Minimum Objective Working Distance | 0.1 mm |
| Heating Element | Pt100-resistive |
| Control Interface | Integrated LCD touchscreen |
| Power Supply | DC |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | PE120 |
| Temperature Range | −25 °C to +120 °C |
| Heating/Cooling Rate | 0.1–20 °C/min |
| Stage Aperture Diameter | 5 mm |
| Sample Area | 35 × 32 mm |
| Temperature Stability & Accuracy | ±0.1 °C |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Control Interface | LCD Touchscreen |
| Minimum Objective Working Distance | 0.1 mm |
| Minimum Condenser Working Distance | 5 mm |
| Stage Dimensions (PE120XY) | 160 × 110 mm |
| Cooling Method | External Recirculating Chiller (ECP Series) |
| Compatibility | Olympus BX, Nikon Ni-E/Ni-U, Zeiss Axio Imager/Axioskop with Optional Mount Adapters |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | RH95 |
| Compatible Stages | THMSG600, MFS, LTS420, HFS600 |
| Max Controlled Volume | 2000 cm³ |
| RH Range | 5–90% RH |
| RH Stability | ±0.5% RH at setpoint |
| RH Ramp Rate | ~7% RH/min |
| Sensor Response Time | ~8 s |
| Sensor Type | Integrated Digital Capacitive T/RH Sensor |
| Inert Gas Input | Up to 5 bar (optional regulator module) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS350V |
| Temperature Range | −196 °C to +350 °C (with LN₂ cooling) |
| Vacuum Range | Down to 10⁻³ mbar |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Temperature Stability | < ±0.1 °C |
| Sensor | 100 Ω Pt RTD |
| Sample Area | Ø22 mm |
| XY Translation Range | 16 mm |
| Optical Aperture | Ø1.3 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS600 |
| Temperature Range | Ambient to +600 °C |
| Maximum Heating Rate | 150 °C/min |
| Temperature Stability & Accuracy | ±0.1 °C |
| X–Y Translation Range | 16 mm each axis |
| Sample Area Diameter | 22 mm |
| Optical Aperture Diameter | 2.0 mm |
| Top Window Thickness | 0.17 mm (standard coverslip) |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Stage Dimensions | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS600 |
| Temperature Range | –196 °C to +600 °C |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Temperature Stability | <0.01 °C |
| Temperature Accuracy | ±0.1 °C (full range) |
| Sample Area Diameter | 22 mm |
| Optical Aperture Diameter | 2.0 mm |
| X/Y Translation Range | 16 mm each axis |
| Upper Window Thickness | 0.17 mm (coverslip-grade fused silica) |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Dimensions (Stage Body) | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSE600 |
| Temperature Range | −196 °C to +600 °C (−196 °C requires optional liquid nitrogen cooling system) |
| Temperature Stability | < 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Optical Aperture Diameter | 2.4 mm |
| Sample XY Translation Range | 15 × 15 mm |
| Sample Area | 22 mm diameter |
| Electrode Configuration | Standard dual-electrode |
| Electrode Integration | Embedded in sealed chamber, compatible with conductive glass LC cells |
| Chamber Environment Control | Vacuum, inert gas (N₂, Ar), or humidity-controlled atmosphere |
| Window Thickness | 0.17 mm |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Stage Dimensions | 137 × 92 × 22 mm |
| Compatible Sample Format | 16 mm diameter cover slips with capillary-filled LC cells (5 µm cell gap) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSG600 |
| Temperature Range | −196 °C to +600 °C |
| Temperature Stability | < 0.01 °C |
| Temperature Resolution | 0.01 °C |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample X/Y Translation Range | 16 mm |
| Heating Zone Diameter | 22 mm |
| Window Thickness (Cover Slip) | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Dimensions | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSG600 |
| Temperature Range | −195 °C to +600 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Stability | <0.01 °C |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample XY Travel | 16 mm |
| Heating Area Diameter | 22 mm |
| Window Thickness | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Dimensions | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1200 |
| Temperature Range | Ambient to 1200 °C |
| Temperature Accuracy & Stability | ±1 °C |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | Ø10 × 5 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Key | Brand: Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1400XY |
| Temperature Range | Ambient to 1400 °C |
| Heating Rate | 1–200 °C/min |
| Temperature Stability | ±1 °C |
| XY Translation Range | X = 4 mm, Y = 10 mm |
| Thermocouple Type | S-type (Pt-10% Rh / Pt) |
| Maximum Sample Size | 5 × 5 × 0.5 mm |
| Minimum Objective Working Distance | 6 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Optical Aperture | 1.7 mm |
| Gas-Tight Chamber | Yes |
| Cooling | Dedicated Water-Circulation System |
| Dynamic Thermal Response | Fast heating and cooling with real-time control |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1500 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy & Stability | ±1 °C over full range |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | φ7 × 6 mm or φ7 × 3 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Vacuum Compatibility | Down to 10⁻³ mbar |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1500 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy & Stability | ±1 °C over full range |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | φ7 × 6 mm or φ7 × 3 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Vacuum Compatibility | Down to 10⁻³ mbar |