Linkam
Filter
Showing all 12 results
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CMS196 |
| Temperature Range | Ambient to –196 °C |
| EM Grid Compatibility | Standard TEM grids, Bessy, Planchette, FEI, Polara formats |
| Motorized XY Stage Resolution | 1 µm |
| Liquid Nitrogen Hold Time | 30 min (standard Dewar) / 6 h (optional 3 L Dewar) |
| Integrated Condenser | For transmitted light and phase contrast |
| Sample Capacity | Up to 3 magnetic sample carriers |
| Startup Time | ≤10 min |
| Drift Performance | <1 nm/min (under stable conditions) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | DSC600 |
| Temperature Range | −196 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | up to 130 °C/min |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FDCS196 |
| Temperature Range | –196 °C to +125 °C (with LN₂ cooling pump) |
| Heating Rate | Up to 150 °C/min |
| Temperature Stability | < 0.1 °C |
| Sensor | 100 Ω Platinum RTD |
| Vacuum Level | Down to 10⁻³ mbar |
| Sample Area | Ø22 mm |
| XY Manipulation Range | 15 mm |
| Window Thickness | 0.5 mm (single ultra-thin optical window) |
| Sample Volume | As low as 5 µL |
| Compatible With | Polarized light, phase contrast, confocal microscopy, Raman spectroscopy, FTIR, and X-ray imaging |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTS420 |
| Temperature Range | −196 °C to +420 °C (liquid nitrogen required for sub-ambient operation) |
| Stage Dimensions | 160 × 80 × 24 mm |
| Sample Area | 53.5 × 43 mm |
| X–Y Translation Range | 15 × 15 mm |
| Standard Slide Holder | 76 × 26 mm |
| Optical Aperture | 2.5 mm diameter |
| Temperature Stability | < ±0.1 °C at isothermal conditions |
| Heating/Cooling Rate | 0.1–50 °C/min (controller-dependent) |
| Sensor | 100 Ω Platinum RTD |
| Environmental Control | Sealed chamber with gas inlet/outlet valves (inert atmosphere or humidity control) |
| Optical Configuration | Compatible with transmitted and reflected light microscopy |
| Electrode Integration | Optional internal electrodes for electric field application or signal measurement (LCD cell-ready configuration) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTS420E-P |
| Temperature Range | Ambient to +420 °C (with optional cryogenic cooling to −196 °C) |
| Electrode Configuration | Integrated dual-electrode system |
| Temperature Control Accuracy | ±0.01 °C |
| Temperature Stability | <0.01 °C |
| Optical Aperture Diameter | 2.4 mm |
| Sample Translation Range (X–Y) | 15 × 15 mm |
| Active Sample Area | 53.5 × 43 mm |
| Compatible Substrates | Standard 76 × 26 mm microscope slides or φ16 mm coverslips |
| Heating Rate | 0.1–50 °C/min |
| Minimum Working Distance (Objective/Condenser) | 6.0 mm / 13.2 mm |
| Stage Dimensions | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | MDSG600 |
| Temperature Range | −196 °C to +600 °C |
| Heating/Cooling Rate Control | 0.01–150 °C/min |
| Position Resolution | 0.05 µm |
| Position Repeatability | <3 µm |
| XY Travel Range | 15 mm × 15 mm |
| Stored Coordinates | 150 (X,Y) |
| Aperture Diameter | 1.3 mm |
| Objective Working Distance Compatibility | 0.1–4.9 mm |
| Condenser Minimum Working Distance | 12.7 mm |
| Sample Holders | 7 mm, 10 mm, or 16 mm diameter |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | MFS |
| Force Range | 0–20 N / 0–200 N |
| Force Resolution | 0.0001 N (20 N range), 0.001 N (200 N range) |
| Displacement Resolution | 1 µm |
| Maximum Travel | 85 mm |
| Speed Range | 0.1–5000 µm/s |
| Temperature Range | −196 °C to +600 °C |
| Environmental Control | Vacuum, inert gas, or humidity-controlled (with RH95 module) |
| Optical Compatibility | Transmission/reflection light, X-ray, Raman, FTIR |
| Electrical Measurement Option | Conductive fixtures available |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | RH95 |
| Compatible Stages | THMSG600, MFS, LTS420, HFS600 |
| Max Controlled Volume | 2000 cm³ |
| RH Range | 5–90% RH |
| RH Stability | ±0.5% RH at setpoint |
| RH Ramp Rate | ~7% RH/min |
| Sensor Response Time | ~8 s |
| Sensor Type | Integrated Digital Capacitive T/RH Sensor |
| Inert Gas Input | Up to 5 bar (optional regulator module) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS350V |
| Temperature Range | −196 °C to +350 °C (with LN₂ cooling) |
| Vacuum Range | Down to 10⁻³ mbar |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Temperature Stability | < ±0.1 °C |
| Sensor | 100 Ω Pt RTD |
| Sample Area | Ø22 mm |
| XY Translation Range | 16 mm |
| Optical Aperture | Ø1.3 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS600 |
| Temperature Range | Ambient to +600 °C |
| Maximum Heating Rate | 150 °C/min |
| Temperature Stability & Accuracy | ±0.1 °C |
| X–Y Translation Range | 16 mm each axis |
| Sample Area Diameter | 22 mm |
| Optical Aperture Diameter | 2.0 mm |
| Top Window Thickness | 0.17 mm (standard coverslip) |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Stage Dimensions | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSG600 |
| Temperature Range | −196 °C to +600 °C |
| Temperature Stability | < 0.01 °C |
| Temperature Resolution | 0.01 °C |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample X/Y Translation Range | 16 mm |
| Heating Zone Diameter | 22 mm |
| Window Thickness (Cover Slip) | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Dimensions | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1500 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy & Stability | ±1 °C over full range |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | φ7 × 6 mm or φ7 × 3 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Vacuum Compatibility | Down to 10⁻³ mbar |