| Brand | MNK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VOC |
| Pricing | Available Upon Request |
| Brand | MNK |
|---|---|
| Model | H300 |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Canister Capacity | 1–4 (optional upgrade to 8–16) |
| Ultimate Vacuum | ≤ 0.007 mbar (≤ 0.05 torr) |
| Vacuum Pump | Edwards nXDSi 15i Dry Scroll Pump |
| Pump Displacement | 12.7 m³·h⁻¹ |
| Pump Ultimate Suction Speed | 11.4 m³·h⁻¹ |
| Cleaning Mode | Manual or Fully Automated Sequence |
| Optional Feature | Repetitive Thermal Desorption Cleaning Cycle |
| Brand | MNK |
|---|---|
| Origin | Sweden |
| Model | BIOTECH Series Vacuum Degasser |
| Internal Volume | 480 µL per Channel |
| Max. Channel Pressure | 70 PSI |
| Wetted Materials | Systec AF™ Membrane, PEEK, Glass-Filled PTFE |
| Dimensions (L×H×W) | 245 × 111 × 59 mm |
| Power Supply | 110–240 V, 50/60 Hz |
| Operating Mode | Continuous 7×24 |
| Design Life | ≥5 Years Fault-Free Operation |
| Vacuum Control | Closed-Loop with ZHCR® Stepper Motor Drive |
| Leak & Error Pre-Diagnosis | Yes |
| Channel Options | 1–6 Channels |
| Chemical & Biological Compatibility | Fully Validated for HPLC Mobile Phases and Biopharmaceutical Buffers |
| Brand | MNK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FID-1000 |
| Price | Upon Request |
| Hydrogen Purity | 99.9995% |
| Zero Air Total Hydrocarbons (as CH₄) | < 0.1 ppm |
| Max. H₂ Flow Rate | 90 cc/min |
| Max. Zero Air Flow Rate | 1000 cc/min |
| Input Power | 120 VAC, 60 Hz, 480 W |
| H₂ Outlet Pressure | 60 psig (414 kPa) |
| Zero Air Outlet Pressure | 40–125 psig (276–862 kPa) |
| Inlet Connection | 1/4" NPT (female) |
| Outlet Connection | 1/8" compression |
| Dimensions | 16.5" H × 10.5" W × 17" D (42 × 27 × 43 cm) |
| Weight | 53 lb (24 kg) |
| Minimum Inlet Air Pressure Requirement | 40 psig (276 kPa) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC-8810 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Coal Industry Specific |
| Detection Limits | Permanent Gases (N₂, CO₂, O₂) < 10 ppm |
| Analysis Time | ≤ 2 min (including backflush) |
| Modular Configuration | Up to 4 independent GC channels |
| Detector Technology | NEMS-based silicon micro-TCD |
| Flow Control | Electronic Pressure Control (EPC) per channel |
| Temperature Control | Independent oven and column-zone heating per module |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor & System Integrator |
| Regional Classification | Domestic (China-Made) |
| Model | GC7890B |
| Pricing | Upon Request |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 (Dual-Detector) |
| Instrument Type | Laboratory Gas Chromatograph |
| Primary Application | High-Purity Gas Analysis |
| Detector Configuration | Pulsed Discharge Helium Ionization Detector (PDHID) + Secondary Detector (e.g., TCD or FID) |
| Carrier Gas | Ultra-High-Purity Helium Only |
| Linear Range | 10⁵ |
| Detection Limit | Sub-ppb for H₂, O₂, N₂, CO, CO₂, CH₄, C₂H₆, C₂H₄, C₂H₂, H₂S, C₃H₈, C₃H₆ |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 Series |
| Instrument Type | Online Gas Chromatograph |
| Detector Configurability | Up to three simultaneous detectors (TCD, uTCD, FID, FPD, ECD, NPD, PDHID) |
| Injection Options | Packed column, split/splitless capillary, valve injection, 6-/12-position liquid auto-sampler, headspace autosampler, pyrolysis injector |
| Oven Temperature Range | +4 °C above ambient to 450 °C (1 °C increment) |
| Oven Temperature Stability | ±0.1 °C at 200 °C |
| Oven Programmable Stages | 16 temperature ramps |
| Cooling Rate | 260 °C to 50 °C in ~6 min |
| Temperature Zones | 8 independently controlled zones |
| Carrier Gas Control | Electronic Pressure Control (EPC), pressure resolution 0.01 kPa, flow resolution 0.01 sccm |
| Display | 5.7-inch color TFT touchscreen |
| Data Interface | Ethernet (IEEE 802.3), PC-controlled operation or standalone mode |
| Remote Capability | Network-enabled remote monitoring, unattended operation, distributed acquisition, centralized control |
| Multidimensional GC Support | Center-cutting and valve-switching configurations enabled |
| Software | Method-driven acquisition with full parameter storage and recall |
| Compliance | Designed for GLP/GMP environments |
| Brand | MNK |
|---|---|
| Model | GC8800-II |
| Origin | Beijing, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Control Interface | IEEE 802.3 Ethernet |
| EPC Module | Integrated Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) |
| Autosampler Compatibility | Dual-tower 24-position liquid autosampler |
| Optional Gas Autosampling | MNK Cylinder & Gas-Phase Autosampler |
| Ancillary Module Support | MNK Flash Vaporizer for LPG, Butadiene, and 1-Butene analysis |
| Data System | Multi-instrument data aggregation |
| Regulatory Alignment | Designed to support GLP-compliant workflows and 21 CFR Part 11–ready audit trail configuration (when paired with validated software) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8810 |
| Instrument Type | Online Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Detector Configuration | Up to 3 Simultaneous Detectors (PDHID, TCD, FID, FPD) |
| Communication Interface | Ethernet-enabled Industrial Bus Architecture |
| Compliance Context | Designed for GLP/GMP-aligned environments with audit-ready data handling capabilities |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M-EAO |
| Product Type | Online Dew Point Analyzer |
| Operating Temperature Range | −110 °C to +20 °C (dew point) |
| Accuracy | ±1 °C dew point |
| Repeatability | ±0.5 °C |
| Response Time | 5 min to T90 (dry-to-wet transition) |
| Output Signal | 4–20 mA |
| Power Supply | 24 VDC |
| Sensor | Imported high-stability chilled-mirror or aluminum oxide sensor (application-optimized) |
| Enclosure Rating | Ex db IIC T6 Gb |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M8880 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | High-Purity Gas Analysis |
| Carrier Gas Options | Single selectable gas (e.g., He, H₂, or Ar) |
| Detector Configuration | Dual-detector, multi-column parallel architecture |
| Temperature Control | 8 independent zones, 20-step programmable ramping |
| Advanced Functionality | Built-in back-flush module enabling heart-cutting and column switching |
| Data System | Dedicated GC workstation with automated flammability triangle (CH₄–O₂–N₂) explosion hazard assessment |
| Detection Limits (v/v) | PDHID — H₂ (0.06 µL/L), CH₄ (0.08 µL/L), CO (0.08 µL/L), C₂H₆ (0.01 µL/L), CO₂ (0.09 µL/L), C₂H₄ (0.01 µL/L), C₂H₂ (0.01 µL/L), C₃H₈ (0.01 µL/L), H₂S (0.01 µL/L), C₃H₆ (0.01 µL/L), SO₂ (0.23 µL/L) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M8880 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Carrier Gas Options | Single selectable gas (e.g., He, H₂, or Ar) |
| Dual-Detector Configuration | PDHID + TCD |
| Independent Temperature Zones | 8 |
| Oven Programmed Ramps | 20-step |
| Back-Flush & Heart-Cut Capability | Integrated |
| Detection Limits (v/v) | PDHID — H₂: 0.06 µL/L, CH₄: 0.08 µL/L, CO: 0.08 µL/L, C₂H₆: 0.01 µL/L, CO₂: 0.09 µL/L, C₂H₄: 0.01 µL/L, C₂H₂: 0.01 µL/L, C₃H₈: 0.01 µL/L, H₂S: 0.01 µL/L, C₃H₆: 0.01 µL/L, SO₂: 0.23 µL/L |
| TCD — O₂ | 49 µL/L, N₂: 70 µL/L |
| PDHID Specifications | Pulsed Discharge Helium Ionization Detector |
| TCD Specifications | Baseline Noise ≤ 20 µV |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MCY600 |
| Operating Temperature | 5–45 °C |
| Sample Gas Pressure | up to 20 kPa (gauge) |
| Sample Flow Rate | 0.2–1.0 L/min |
| Power Supply | 12–24 VDC |
| Output Signal | 4–20 mA |
| Communication Interface | RS485 (Modbus RTU) |
| Measurement Ranges | 0–5%, 0–10%, 0–21%, 0–50%, 0–90%, 90–100%, 0–100% O₂ (v/v) |
| Linearity Error | ±2% FS |
| Stability | ±2% FS / 7 days |
| Repeatability | ±1% FS |
| Cross-Interference Resistance | NH₃, CO, CO₂, CH₄ |
| Corrosive Gas Tolerance | Yes (e.g., H₂S) |
| Sensor Type | Thermal-Magnetic Paramagnetic Detection |
| Vibration Immunity | High |
| Consumable-Free Design | Yes |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MDL100 |
| Dilution Ratio Range | 10–1000× |
| Output Flow Rate | 0.5–5 L/min |
| Dilution Modes | Binary and Multi-component |
| Flow Control Principle | Thermal Mass Flow Control |
| Flow Accuracy | ±0.5% of reading |
| Repeatability | <0.2% RSD |
| Linearity (R²) | >0.9999 |
| Overall Dilution Uncertainty | <1% |
| Control Interface | Integrated Touchscreen PC with Customizable Software |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MDL200 |
| Dilution Ratio Range | 2–100× |
| Output Flow Rate | 1–5 L/min |
| Dilution Mode | Binary (Two-Gas) |
| Flow Control Technology | Thermal Mass Flow Control |
| Flow Accuracy | ±0.5% of reading |
| Repeatability | <0.2% RSD |
| Linearity (R²) | >0.9999 |
| Overall Dilution Uncertainty | <1% |
| Compliance | ISO 6145 |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MDL900 |
| Dilution Range | 100–10,000× (extendable to 10⁵×) |
| Output Flow Rate | 0.5–5 L/min |
| Flow Accuracy | ≤ ±0.5% of reading |
| Flow Repeatability | < ±0.2% RSD |
| Linearity (R²) | > 0.9999 |
| Dilution Accuracy | < ±2% |
| Maximum Back Pressure | 0.5 MPa |
| Compliance | ISO 6145 |
| Calibration Traceability | NIM (National Institute of Metrology, China) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Models | Three Configurable Systems (CO/CO₂/H₂O/O₂ Integrated) |
| Price Range | USD 4,200 – 7,000 (FOB Beijing) |
| Brand | MNK |
|---|---|
| Model | MF600, MF601, MF610, MF640 |
| Origin | Beijing, China |
| Permeation Chamber | Φ24 mm × 130 mm (MF600/MF601/MF640), Φ25 mm × 170 mm (MF610) |
| Temperature Range | +5 °C to +100 °C above ambient (MF610/MF640), +10 °C to +100 °C above ambient (MF600/MF601) |
| Temp. Control Accuracy | ±0.1 °C |
| Gas Flow Rate | 0–1000 mL/min (MF600), 0–500 mL/min (MF601/MF640), 100 mL/min (MF610) |
| Flow Meter Accuracy | ±1% SP (0–10 L/min, MF610) |
| Dilution Ratio | 6:1 to 96:1 (MF610) |
| Carrier Gas Inlet | 1/4″ Swagelok (MF601/MF640) |
| Inlet Pressure | 0.3–0.4 MPa (MF601/MF640) |
| Chamber Material | PTFE-coated aluminum (MF600/MF601/MF640), stainless steel (MF610) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MF610 |
| Temperature Range | 25–100 °C (±0.1 °C stability) |
| Permeation Chamber Dimensions | Φ24 mm × 130 mm |
| Mass Flow Range | 0–10 L/min (configurable with optional 1 L/min or 20 L/min modules) |
| Dilution Ratio | 6:1 to 96:1 (standard configuration) |
| Power Supply | AC 220 V, 200 W |
| Dimensions (L×W×H) | 490 × 402 × 155 mm |
| Weight | 18 kg |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MF620 (Hg) / MF630 (HCHO) |
| Calibration Traceability | NIST-Traceable Permeation Tubes |
| Concentration Range | 0.1 ppb – 500 ppm (adjustable for both Hg and HCHO) |
| Flow Control | Precision Mass Flow Controllers (MFCs), 0–1000 mL/min, user-programmable or panel-controlled |
| Carrier Gas | Compressed air, nitrogen, or custom gas (dual inlet optional) |
| Configuration | Benchtop with portable footprint (W×D×H: 320×380×220 mm) |
| Permeation Tube Capacity | Up to 4 independent permeation tubes (standard: 1 Hg + 1 HCHO |
| Dilution Architecture | Dual independent dilution paths with separate temperature-controlled permeation chambers (±0.1 °C stability) |
| Output Modes | Zero gas, span gas, or alternating zero/span sequences |
| Compliance | Designed for ISO/IEC 17025-compliant calibration workflows |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MG220 |
| Pricing | Upon Request |
| Operating Pressure Range | 0.7–4 MPa |
| Drive Gas | Dry Air or Inert Gas (0.4 MPa) |
| Auxiliary Gas Flow Rate | 50–200 mL/min |
| Internal Tubing | 1/16″ SilcoTek-Passivated Stainless Steel |
| Valve Core Volume Options | 0.06–2 μL (Standard: 1 μL) |
| Dead Volume | Minimized (<10 μL typical) |
| Repeatability | RSD < 2% (n ≥ 6) |
| Dimensions (W×D×H) | 130 mm × 200 mm × 200 mm |
| Mounting | Direct installation above GC inlet port |
| Weight | ~1.5 kg |
| Surface Treatment | SilcoTek® SilcoNert® 2000 inert coating applied to entire fluid path |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MGCH-300 |
| Hydrogen Purity | 99.999% |
| Flow Rate | 0–300 mL/min |
| Operating Pressure | 0.4 MPa / 0.6 MPa (dual-range adjustable) |
| Power Consumption | 150 W |
| Input Voltage | 220 V ±10% |
| Dimensions (W×D×H) | 270 × 180 × 340 mm |
| Net Weight | 10 kg |
| Type | Electrolytic Hydrogen Generator (Alkaline KOH-based) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MPS950 |
| Product Type | Online Dew Point Analyzer |
| Operating Temperature Range | –100 to 0 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤ ±1 °C |
| Sample Flow Rate | 2–3 L/min (recommended: 2 L/min) |
| Response Time (90%) | 15 min at –10 to –80 °C |
| Pressure Range | 0–1 MPa |
| Ambient Operating Conditions | 5–45 °C, 0–90% RH |
| Output Signal | 4–20 mA |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Dimensions | 270 × 132 × 330 mm |
| Weight | ~3 kg |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MQ701-16 / MQ701-32 Integrated Solution |
| Pricing | Available Upon Request |
| Core Components | MQ801 Vacuum Sampling Chamber, MQ701-16/MQ701-32 16-/32-Position Automated Gas Bag Injector, MODEL401 Precision Gas Dilution System |
| Compliance | Designed to meet HJ 38–2017 (China EPA Standard for Determination of Total Hydrocarbons, Methane, and NMHC in Stationary Source Exhaust) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MQ701-16 |
| Configuration | 16-position gas-tight sampling station |
| Compatibility | Agilent GC systems (native control via Agilent ChemStation/OpenLab), universal TTL/RS-232 trigger interface for cross-platform integration |
| Vacuum Source | Integrated diaphragm vacuum pump (oil-free, zero carryover) |
| Sample Path | Silanized stainless steel tubing with active sulfur resistance |
| Heating | Electrically heated transfer lines (adjustable 40–120 °C) |
| Control | PC-based software with method scheduling, audit trail, and sequence logging |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MQ701-6S |
| Sampling Positions | 6 / 16 / 32 (customizable) |
| Power Consumption | 100 W |
| Power Supply | 220 V, 50 Hz |
| Net Weight | 15 kg (6-position), 25 kg (16-position) |
| Dimensions | 350 × 371 × 270 mm (6-position), 400 × 480 × 630 mm (16-position) |
| Tubing | 1/16″ SilcoNert®-treated stainless steel |
| Interface Options | RS-232, Touch Control, EVENT Trigger, BCD Output |
| Vacuum Source | Diaphragm Pump |
| Compliance | Compatible with ASTM D5504, EPA Method TO-15 & TO-14A, ISO 16000-6 |
| Brand | MNK |
|---|---|
| Model | MQY301 |
| Origin | Beijing, China |
| Configuration | 5-channel gas bag sampler + 1-channel liquid flash-vaporization inlet |
| Dimensions (W×D×H) | 400 × 255 × 300 mm |
| Net Weight | 15 kg |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 300 W |
| Maximum Flash-Vaporization & Jacket Temperature | 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Liquid Injection Pressure Range | 100–400 psi |
| Sample Transfer Line | Passivated stainless steel |
| Interface Options | AUX trigger, touch control, GC instrument control port |
| Inlet Valve | Integrated 6-position gas sampling valve with quantitative loop |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MS200 |
| Sample Inlet Pressure Range (Liquid) | 0.69–2.75 MPa |
| Sample Inlet Pressure Range (Gas) | ≤2.07 MPa |
| Vaporization Temperature Control Range | Ambient to 150 °C |
| Transfer Line Heating Range | Ambient to 150 °C |
| Operating Ambient Temperature | –18 °C to +65 °C |
| Power Supply | 220 VAC, 50 Hz, max. 3.0 A |
| Dimensions (H×W×D) | 230 mm × 190 mm × 350 mm |
| Compliance | Designed for integration with GC and GC-MS systems in petroleum refining and hydrocarbon analysis labs |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | MS200S |
| Pricing | Available Upon Request |
| Liquid Sample Inlet Pressure Range | 0.69–2.75 MPa |
| Gas Sample Inlet Pressure Range | 0.69–2.07 MPa |
| Temperature Control Range (Heating & Trace Heating) | Ambient +5°C to 230°C |
| Temperature Stability | ±0.1°C |
| Carrier Gas Flow Rate | 0–100 mL/min |
| Flow Resolution | 0.1 mL/min |
| Operating Ambient Temperature | −18°C to +65°C |
| Surface Passivation | SilcoTek® SilcoNert®-treated Stainless Steel Tubing |