PULUODY
Filter
Showing 391–412 of 412 results
| Brand | PULUODY |
|---|---|
| Model | PST-890 |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Detection Range | 1–450 µm (optional 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibration), <10% (USP/ISO 21501 calibration) |
| Channel Count | 1000 adjustable channels (customizable from 4 to 128 size bins) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Temperature Range (Fluid) | 0–80 °C |
| Software | V8.9 Integrated Analysis Suite with FDA 21 CFR Part 11 Compliance |
| Standards Compliance | ChP 0903, USP <788>/<789>/<797>, EP 10.0, ISO 21501, ISO 11171, GB/T 11446.9, GB 8368, NAS 1638, ISO 4406, ASTM D6786, and 510+ international pharmacopoeial & industrial standards |
| Brand | PULUODY |
|---|---|
| Model | PST-890 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional extended to 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated), <10% (USP/ISO 21501 calibrated) |
| Channel Count | 1000 adjustable channels (customizable from 4 to 128 size bins) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Operating Temperature | Fluid 0–80 °C, Ambient –15–50 °C |
| Compliance | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Model | PST-890 |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 1–450 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 4-channel user-defined bins) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (ISO 21501-calibrated) |
| Temperature Range (fluid) | 0–80 °C |
| Compliance | FDA 21 CFR Part 11, ASTM D6786, ISO 21501-4, ISO 11171, USP <788>/<789>, EP 10.0, ChP 0903, GB/T 11446.9-2013, YBB00272004-2015, GB 8368 |
| Software | V8.9 Regulatory-Compliant Particle Analysis Suite with Audit Trail, e-Signature, and 5-Tier User Permissions |
| Calibration Standards | NIST-traceable latex spheres, JJG 1061, or ISO 21501-4 reference materials |
| Sample Compatibility | Aqueous & non-aqueous parenterals, lipid emulsions, lyophilized powders (reconstituted), ophthalmic solutions, vaccines, WFI, medical packaging extracts, infusion sets, filter challenge fluids |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890SIS |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Resolution | 1000 adjustable channels (down to 0.01 µm bin width) |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Resolution Compliance | >95% per ChP 2015/2020 |
| Flow Rate (Sampling) | 5–150 mL/min |
| Flow Rate (Rinse) | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Software | V8.9 Integrated Analysis Suite with 21 CFR Part 11 Compliance |
| Regulatory Alignment | ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0, BP 2019, JP 17, ISO 21510, ISO 11171, NAS 1638, ASTM D6786, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890SIS |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Detection Range | 1–450 µm (optional 0.03–3000 µm) |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP/ISO 21501) |
| Channel Count | 1000 adjustable channels (configurable from 4 to 128 size bins) |
| Sampling Flow Rate | 5–150 mL/min |
| Cleaning Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Compliance | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890SIS |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 4-channel custom binning) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Temperature Range (Fluid) | 0–80 °C |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready, Audit Trail, Electronic Signature, 5-Tier User Permission Architecture |
| Software | V8.9 Particle Analysis Suite (PC + embedded touchscreen) |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-traceable latex spheres |
| Regulatory Alignment | ChP 0903 (2015/2020), USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21510, ISO 11171, NAS 1638, ISO 4406 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | PULL-GP20-1000 |
| Instrument Type | Standard Gas Sampler |
| Configuration | Single-Port Sampling Cylinder |
| Flow Range | 0–20 L/min |
| Maximum Sampling Pressure | 0–20 MPa |
| Flow Stability | ±1% FS |
| Flowmeter Accuracy | ±1% FS |
| Service Life Under Max Flow & Backpressure | ≥100,000 cycles |
| Continuous Operation at Max Flow & Backpressure | 24 h |
| Working Pressure Range | 4–20 MPa |
| Burst Pressure Rating | 7–38 MPa |
| Operating Temperature Range | –60 °C to +80 °C |
| Cylinder Material | ASTM A240 UNS S31603 (316L stainless steel) or GB/T 1220 1Cr18Ni9Ti |
| Internal Coating (Optional) | PTFE lining |
| Pressure Gauge | Integrated bourdon-tube gauge with direct-read dial |
| Valve Configuration | Dual-valve assembly — one standard needle valve, one pressure-relief safety valve with burst disc |
| Mounting Bracket | 304 stainless steel support stand (optional) |
| Volume Capacity | 1000 mL |
| Compliance | SH/T 0233–1992, SY/T ZJ1045 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PULL-GP20-300 |
| Instrument Type | Single-Channel Cryogenic Gas/Liquid Sampler |
| Flow Range | 0–20 L/min |
| Maximum Operating Pressure | 4–20 MPa |
| Flow Stability | ≤5% over 1 h |
| Flowmeter Accuracy | ≥±2.5% FS |
| Service Life at Max Flow & Backpressure | ≥5000 h |
| Continuous Operation Duration at Max Flow & Backpressure | 8 h |
| Construction Material | ASTM A240 316L Stainless Steel |
| Operating Temperature Range | –190 °C to +80 °C |
| Volumetric Capacity Options | 100 mL to 5000 mL |
| Compliance | SH/T 0233–1992 (Liquefied Petroleum Gas Sampling Method) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PULL-GP20-500 |
| Instrument Type | General-Purpose Gas Sampler |
| Configuration | Single-Channel Sampling System |
| Flow Rate Range | 0–0.5 L/min |
| Maximum Suction Pressure | 0–20 MPa |
| Flow Stability | ≤ ±5% |
| Flowmeter Accuracy | ≥ ±2.5% |
| Service Life at Max Flow & Backpressure | ≥ 5000 h |
| Drift Under Rated Load | ≤ ±5% |
| Material | 1Cr18Ni9Ti Stainless Steel (AISI 321 Equivalent) |
| Design Pressure | 20 MPa |
| Hydrostatic Test Pressure | 35 MPa |
| Operating Temperature Range | –60 °C to +80 °C |
| Available Volumes | 25 mL to 10,000 mL |
| Compliance | SH/T 0233, SY/T 1045 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PYX-2A |
| Instrument Type | Optical Light-Blockage Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 1–500 µm |
| Adjustable Channel Count | 16 (standard), up to 1096 user-defined channels |
| Sample Volume | 0.2 mL to custom-defined volume |
| Size Accuracy | ≥95% |
| Counting Accuracy | ±5% |
| Sampling Precision | ±0.5% |
| Flow Rate | 5–100 mL/min |
| Dimensions | 220 × 320 × 335 mm |
| Weight | 9.8 kg |
| Power Supply | 220–240 VAC, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PYX-2A-1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 1–500 µm |
| Adjustable Channel Count | 16 (standard), up to 1096 user-defined channels |
| Sample Volume | 0.2 mL to user-defined |
| Size Accuracy | ≥95% |
| Counting Accuracy | ±5% |
| Sampling Precision | ±0.5% |
| Flow Rate | 5–100 mL/min |
| Dimensions | 220 × 320 × 335 mm |
| Weight | 9.8 kg |
| Power Supply | 220–240 VAC, 50 Hz |
| Brand | PULUODY |
|---|---|
| Model | P-III (or P3) |
| Instrument Type | Optical Surface Particle Counter |
| Detection Principle | Light Scattering (Laser-Based) |
| Particle Size Channels | Configurable across six channel sets (A–F), ranging from 0.1 µm to 25.0 µm |
| Size Accuracy | ≤ ±30% |
| Concentration Accuracy | ≤ ±30% |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | ≤ 5% |
| Flow Rate Options | 2.83 L/min or 28.3 L/min |
| Sampling Duration | Programmable (3–60 s) |
| Operating Temperature | –40 °C to +120 °C |
| Environmental Range | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Compliance | ISO 14644-1, ISO 14644-9, ISO 21501-4, JIS B 9921 |
| Data Integrity Features | Role-based access control, audit trail, electronic records (21 CFR Part 11 ready) |
| Interface Options | RS232, RS485, LAN, USB |
| Storage | Configurable real-time/timed logging with unlimited capacity |
| Alarm Outputs | Customizable particle count/mass thresholds |
| Probe Options | Straight probe (UK4400302), 90° angled probe (UK4400304), multifunctional surface probe (UK44003012) |
| Brand | PULUODY |
|---|---|
| Model | P-III |
| Type | Optical Surface Particle Counter |
| Measurement Principle | Light Scattering (Laser-Based) |
| Particle Size Channels | Configurable across 6 preset modes (A–F), down to 0.1 µm |
| Accuracy | ±30% for size distribution & concentration |
| Flow Rate | 2.83 L/min or 28.3 L/min (selectable) |
| Sampling Duration | 3–60 s (programmable) |
| Compliance | ISO 14644-1, ISO 14644-9, ISO 21501-4, JIS B 9921 |
| Data Integrity | Audit trail, role-based access control, electronic records (21 CFR Part 11–ready architecture) |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Interface Options | RS232, RS485, LAN, USB |
| Detection Modes | Count, Mass, Net Efficiency |
| Alarm Outputs | Customizable count/mass thresholds |
| Probe Flexibility | Multiple interchangeable sampling probes for flat, curved, recessed, or confined surfaces |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | P-III ST |
| Instrument Type | Optical Surface Particle Counter |
| Measurement Principle | Light Scattering (Laser-Based) |
| Standard Compliance | ISO 14644-9, ISO 21501-4, JIS B 9921 |
| Flow Rate Options | 2.83 L/min & 28.3 L/min |
| Detectable Particle Sizes | 0.1 µm to 25.0 µm (configurable channels A–F) |
| Size Accuracy | ≤ ±30% |
| Concentration Accuracy | ≤ ±30% |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | ≤ 5% |
| Operating Temperature | −40 °C to +120 °C |
| Environmental Operating Range | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Interfaces | RS232, RS485, LAN, USB |
| Data Storage | Configurable real-time/timed storage, unlimited capacity |
| Audit Trail & User Access Control | Yes |
| Regulatory Features | Electronic records, role-based permissions, FDA 21 CFR Part 11–compatible logging (when enabled) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | P-III+ |
| Price | USD 105,000 (FOB) |
| Particle Size Channels | A: 0.3, 2.5, 10 µm |
| B | 0.3, (0.5/1.0/2.5/5.0), 10 µm |
| C | 0.3, 0.5, 1.0, 2.5, 5.0, 10 µm |
| D | 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 µm |
| E | 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 µm |
| F | 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 µm |
| Size Accuracy | ≤ ±30% |
| Concentration Accuracy | ≤ ±30% |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | ≤ 5% |
| Flow Rates | 2.83 L/min and 28.3 L/min (selectable) |
| Sampling Duration | 3–60 s (programmable) |
| Operating Temperature | −40 to 120 °C |
| Environmental Operating Range | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1, ISO 14644-9 |
| Data Interfaces | RS232, RS485, LAN, USB |
| Audit Trail & User Access Control | Yes |
| Detection Modes | Count, Mass, Net Efficiency |
| Alarm Outputs | Configurable count/mass thresholds |
| Storage | Unlimited real-time/timed logging |
| Optional Accessories | Straight probe (UK4400302), 90° probe (UK4400304), Multi-functional probe (UK4400301) |
| Brand | PULUODY |
|---|---|
| Model | TQ-01A |
| Application | Automated degassing of purified water and distilled water for dissolution testing |
| Flow Rate | 1.6 L/min |
| Volume Accuracy | ±1% (for set volumes ≥2 L) |
| Dissolved Oxygen Residual | 3.0–5.0 mg/L (upgradable to <2.8 mg/L) |
| Operating Temperature Range | 18–42 °C (adjustable |
| Heating Precision | ±2 °C |
| Pre-filter Options | 40 µm / 25 µm / 20 µm stainless steel mesh |
| Dimensions (L×H×W) | 500 × 340 × 295 mm |
| Rated Power | 1700 W |
| pH Compatibility | 1–14 (non-surfactant aqueous media only) |
| Filter Type | Inlet metal mesh pre-filter |
| Compliance | Designed for USP <711>, <1092>, and FDA guidance on dissolution apparatus qualification |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TQ-01A Vacuum Degasser |
| Unit Price | USD 12,300 (FOB) |
| Volumetric Dispensing Range | Unlimited |
| Dispensing Accuracy | ±1% (≥2 L) |
| Medium Compatibility | Dissolution media (pH 1–14, non-ionic surfactant-free) |
| Degassing Flow Rate | 1.6 L/min |
| Dimensions (L×H×W) | 500 × 340 × 295 mm |
| Rated Power | 1700 W |
| Heating Control Accuracy | ±2 °C |
| Residual Dissolved Oxygen | 3.0–5.0 mg/L (upgradable to <2.8 mg/L) |
| Minimum Inlet Medium Temperature | ≥18 °C |
| Pre-filter Options | 40 µm / 25 µm / 20 µm stainless steel mesh |
| Brand | PULUODY |
|---|---|
| Model | TQ-01A |
| Application | Pharmaceutical Dissolution Media Deaeration |
| Display | High-Resolution Touchscreen LCD |
| Heating Range | 35–42 °C (adjustable to non-heating mode) |
| Volume Accuracy | ±1% (for set volumes ≥2 L) |
| Dispensing Resolution | 0.1 L |
| Flow Rate | 1.6 L/min |
| Dimensions (L×H×W) | 500 mm × 340 mm × 295 mm |
| Rated Power | 1700 W |
| Temperature Control Accuracy | ±2 °C |
| Residual Dissolved Oxygen | 3.0–5.0 mg/L (upgradable to <2.8 mg/L) |
| Minimum Inlet Medium Temperature | ≥18 °C |
| Pre-Filter Options | 40 µm / 25 µm / 20 µm Stainless Steel Mesh |
| Compatible Media | Purified water, distilled water (pH 1–14, surfactant-free) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PULUODY TQ-01A Membrane-Based Online Degasser |
| Price | USD 12,200 (FOB China) |
| Display | High-resolution LCD with capacitive touch interface |
| Heating Range | 35–42 °C (switchable to non-heating mode) |
| Volume Accuracy | ±1% (for volumes ≥2 L) |
| minimum dispensing volume | 100 mL |
| Flow Rate | 1.6 L/min |
| Degassed Dissolved Oxygen (DO) | 3.0–5.0 mg/L (upgradable to <2.8 mg/L) |
| Compatible Media pH Range | 1–14 (non-surfactant aqueous solutions only) |
| Pre-filter Options | 40 µm / 25 µm / 20 µm stainless steel mesh |
| Dimensions (L×H×W) | 500 mm × 340 mm × 295 mm |
| Rated Power | 1700 W |
| Temperature Stability | ±2 °C |
| Minimum Inlet Media Temperature | ≥18 °C |
| Enclosure Material | Corrosion-resistant anodized aluminum and food-grade polymer housing |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | TQ-01A |
| Display | High-resolution LCD touchscreen interface |
| Pre-heating capability | Yes, prior to degassing |
| Fluid delivery accuracy | ±1% of set volume (≥2 L) |
| Volume resolution | 0.1 L |
| Operating temperature range | 35–42 °C (heating optional) |
| Media compatibility | Deionized water, distilled water, aqueous buffers (pH 1–14, non-surfactant) |
| Degassing efficiency | 3.0–5.0 mg/L dissolved oxygen (DO) |
| Flow rate | 1.6 L/min |
| Dimensions (L×H×W) | 500 × 340 × 295 mm |
| Rated power | 1700 W |
| Heating accuracy | ±2 °C |
| Inlet filtration | Optional 40/25/20 µm stainless-steel mesh pre-filter |
| Minimum inlet fluid temperature | ≥18 °C |
| Maintenance design | Modular, tool-free component replacement |
| Brand | PULUODY |
|---|---|
| Model | UP-200 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Light Scattering (Dual-Laser Narrow-Beam) |
| Particle Size Range | 0.1–100 µm (optional 0.03–3000 µm) |
| Accuracy | ≤±3% (typical) |
| Coincidence Error | ≤±3% at ≥1000 particles/mL |
| Sampling Flow Rate | 5–100 mL/min |
| Sampling Precision | ≤±1% |
| Pressure Range | 0–0.5 MPa (standard), up to 31.5 MPa (with pressure regulator) |
| Fluid Temperature Range | 0–80 °C |
| Calibration Standard | NIST-traceable polystyrene latex spheres |
| Output Interfaces | USB, LAN, RS232/RS485, 4–20 mA analog output |
| Compliance | ISO 21501-2:2007, GB/T 29024.2–2016, JJG 1061–2010, SJ/T 11638–2016, GB/T 11446.3 & 11446.9–2013 |
| Key | Brand: PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Origin Category | Domestic (China) |
| Model | Pull-Series A |
| Pricing | Upon Request |