PULUODY
Filter
Showing 331–360 of 412 results
| Brand | PULUODY |
|---|---|
| Model | PMT-2GK |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–0.5 µm (standard), customizable to 1–100 µm or 4–70 µm (c) |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Spheres |
| Sampling Method | Precision Metering Piston Pump |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output with configurable alarm relay |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + integrated touchscreen UI) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2GN |
| Pricing | Upon Request |
| Brand | PULUODY |
|---|---|
| Model | PMT-2GT |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.5–20.0 µm (standard), customizable to 1–100 µm or 4–70 µm(c) |
| Resolution | 0.1 µm(c) minimum detectable threshold |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable alarm triggers |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex sphere reference materials |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2J |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 0.1–0.5 µm (standard) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Piston Pump Regulation |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Output Interface | 4–20 mA analog |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + integrated embedded OS) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2K |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–0.5 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sample Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Output | Particle count per mL & ISO 4406 / NAS 1638 contamination codes |
| Interface | 4–20 mA analog output,超标 alarm (customizable) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen GUI) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2L |
| Price | USD 31,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres |
| Measuring Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) resolution |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable alarm threshold |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC & iPad-compatible) |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PMT-2L |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 1–450 µm (standard), optional 0.03–3000 µm |
| Calibration Standards | USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2LD |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Detector |
| Measurement Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen) |
| Display | Color LCD Touch Interface + Optional Wireless Keyboard/Mouse |
| Output | 4–20 mA Analog Signal |
| Alarm Function | Configurable Threshold-Based Particle Count Alert |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 Contamination Code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Support | GLP/GMP Audit Trail Ready, FDA 21 CFR Part 11–Compatible Data Logging (via optional software module) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2LD |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 0.5–20.0 µm (standard) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog interface with configurable particle concentration alarm |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2LS |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog interface with programmable contamination alarm |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen UI) |
| Display | Color LCD touch interface + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO Class 1–5 cleanroom environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2PB |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Measurement Range | 0.1–0.5 µm & 0.5–20.0 µm (customizable to 1–100 µm or 4–70 µm(c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable particle-exceedance alarm |
| Data Interface | iPad-compatible wireless data acquisition system |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference |
| Compliance | Supports GLP/GMP audit trails, FDA 21 CFR Part 11–ready software architecture (user authentication, electronic signatures, change control logs) |
| Display & Control | 7-inch color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Scope | Semiconductor cleaning fluids, ultrapure water (UPW), photomasks, silicon wafers, flat-panel display substrates, PCB etchants & rinsates, nano/microfiltration effluents, polymer solutions, and insoluble particulate analysis in organic solvents |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2QL |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-laser narrow-beam light scattering |
| Sensor Generation | 8th-generation dual-laser optical sensor |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision metering piston pump |
| Flow Control | Dual-stage electromagnetic + precision piston pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable alarm output |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination code |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + tablet-compatible) |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 8573-4, ASTM F3239, USP <788>, <789>, and semiconductor-grade water monitoring per SEMI F63 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2QLZ |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Spheres |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable alarm thresholds |
| Data Interface | iPad-compatible wireless acquisition system |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1/2 cleanroom monitoring, USP <788> and <789>, ASTM F3239, and semiconductor-grade ultrapure water (UPW) specifications |
| Brand | PULUODY |
|---|---|
| Model | PMT-2RX |
| Sensor Technology | 8th-generation dual-laser narrow-beam particle detection |
| Detection Range | 0.1–0.5 µm and 0.5–5.0 µm (customizable from 0.1 µm to 100 µm) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501, or NIST-traceable latex spheres |
| Output Interface | 4–20 mA analog output with configurable contamination alarm |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PMT-2S |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measurement Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Piston Pump Regulation |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-Traceable Latex Spheres |
| Output Interface | 4–20 mA analog output with configurable alarm threshold |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Operating Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & Standalone Modes) |
| Compliance Support | GLP/GMP audit trails, FDA 21 CFR Part 11-ready configuration (user authentication, electronic signatures, change logs) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2s |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–1.0 µm (standard) |
| Sample Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO Class 1–5 cleanroom liquid monitoring environments |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + integrated touchscreen UI) |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Connectivity | USB, Ethernet, optional iPad-based remote acquisition |
| Brand | PULUODY |
|---|---|
| Model | PMT-2SD |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation |
| Measuring Range | 0.1–0.5 µm & 0.5–5.0 µm (customizable to 1–100 µm or 4–70 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Data Output | 4–20 mA analog interface,超标 alarm output (customizable) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen UI) |
| Display | Color LCD touch interface + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1/2, USP <788>, ISO 8573-4, and semiconductor-grade liquid purity monitoring workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2SH |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-laser light scattering with narrow-beam geometry |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference materials |
| Detection Range | 0.1–0.5 µm, 0.2–2.0 µm, 0.5–20.0 µm (user-definable sub-ranges: 1–100 µm or 4–70 µm(c) |
| minimum detectable size | 0.1 µm(c)) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Flow Control | Precision metering piston pump + electromagnetic flow regulation |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + tablet-compatible) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PMT-2SY |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.05–0.2 µm, 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable particle concentration alarm |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination code |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, ISO 21501-4 compliant |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2T |
| Price | USD 31,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Measurement Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Output Interface | 4–20 mA analog output with configurable alarm relay |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Operating Voltage | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2YC |
| Price | USD 75,000 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.5–20.0 µm (standard) |
| Sensor Generation | 8th-Generation Dual-Laser Particle Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Output Interface | 4–20 mA analog output with programmable alarm thresholds |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + iPad-compatible) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2ZX |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog interface with configurable alarm thresholds |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & touchscreen UI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PMT- |
| Pricing | Available Upon Request |
| Detection Principle | Light Obscuration (7th-Generation Dual-Laser Narrow-Beam Sensor) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 2–100 µm (or 4–70 µm[c]) |
| Customizable Channels | Up to 1000 size bins, user-selectable 16 channels |
| Accuracy | <3% typical |
| Flow Rate | Sampling: 10–60 mL/min |
| Cleaning | 20–150 mL/min |
| Operating Pressure | 0–0.6 MPa (standard), up to 50 MPa (with pressure regulator) |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Temperature Range | Fluid: 0–80 °C |
| Ambient | −15–50 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C, ISO 11500 |
| Output Interface | RS232 / RS485-to-USB / Native USB |
| Display | Color LCD touchscreen |
| Power Input | 100–265 VAC, 50–60 Hz |
| Optional Modules | Water Activity (0–1.0 aw, ±0.02 accuracy, NIST-traceable), Trace Moisture (0.1–100,000 ppm), Temperature (−45–125 °C, ±0.00003 °C stability) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PQ-2A |
| Price | USD 13,800 (FOB) |
| Measurement Principle | Electromagnetic Induction-Based Ferrous Particle Quantification |
| Sensitivity | 0.1 mg/g (100 ppm) |
| Max. Concentration Range | 30,000 mg/g |
| Detectable Ferrous Particle Size | >5 µm |
| Sample Volume | 2–5 mL per test |
| Operating Temperature | 0–55 °C |
| Power Supply | 220 V ±15%, 50 Hz or Integrated Rechargeable Li-ion Battery |
| Brand | PULUODY |
|---|---|
| Origin | United Kingdom |
| Manufacturer | PULUODY Analysis & Testing Group Ltd. |
| Type | Imported Industrial Instrument |
| Model | PQ-2A |
| Sensitivity | 0.1 mg/g |
| Max. Iron Concentration Range | 30,000 mg/g |
| Detectable Particle Size | >5 µm |
| Sample Volume | 2–5 mL per test |
| Operating Temperature | 0–55 °C |
| Power Supply | 220 V ±15%, 50 Hz or portable DC power |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | PRF-III |
| Instrument Type | Optical Particle Counter |
| Magnetic Head Field Strength | 100–1000 Gs (≥600 Gs at peak working point) |
| Deposition Speed | 70 rpm (spectrogram formation), 150 rpm (cleaning/fixation), 200 rpm (drying) |
| Reproducibility | <8% mean error across 8 microscope fields (qualitative), <12% across 4 fields (quantitative) |
| Linear calibration range (optical density vs. debris mass) | 0–55% |
| Oil sample contamination range | 0–3000 ppm |
| Substrate | 55 × 55 × 0.17 mm optical glass slide |
| Control | Four-button tactile interface with real-time RPM and timer display |
| Dimensions | 420 × 310 × 280 mm |
| Power | 220 V, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PQ-2A |
| Price | USD 64,500 (FOB China) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PRF-III-01 |
| Instrument Type | Optical Particle Counter for Wear Debris Analysis |
| Core Function | Magnetic Separation & Morphological Characterization of Ferrous Wear Particles in Lubricants |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PS3100-3L |
| Instrument Type | General-Purpose Ultrasonic Cleaner |
| Capacity | 3 L |
| Ultrasonic Frequency | 43 kHz |
| Ultrasonic Power | 100 W |
| Adjustable Power | Yes |
| Adjustable Temperature | Yes |
| Adjustable Timer | Yes |
| Sound-Dampening Lid | Included |
| Drain/Inlet | Manual Valve |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PS3200 |
| Instrument Type | Dedicated Ultrasonic Cleaner |
| Tank Capacity | 4 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 100 W |
| Adjustable Power | Yes (40–100% in 1% increments) |
| Adjustable Heating Temperature | Yes (20–60 °C) |
| Digital Timer Range | 1–199 min |
| Sound-Dampening Lid | Included |
| Manual Drain Valve | Yes |
| Heating Power | 150 W |
| Tank Dimensions (L×W×H) | 300 × 150 × 150 mm |
| External Dimensions (L×W×H) | 330 × 180 × 290 mm |
| Power Supply | 220 V / 50 Hz |
| Tank Material | 316L Stainless Steel |
| Basket Material | Argon-Welded 304 Stainless Steel Mesh |