PULUODY
Filter
Showing 361–390 of 412 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PS3200-6L |
| Capacity | 6 L |
| Ultrasonic Frequency | 53 kHz |
| Ultrasonic Power | ≥200 W |
| Power Adjustment | Yes (40–100%, 1% stepwise) |
| Temperature Control Range | 20–60 °C |
| Heating Power | 150 W |
| Timer Range | 1–199 min |
| Tank Dimensions | 30 × 15 × 15 cm |
| Overall Dimensions | 33 × 18 × 29 cm |
| Power Supply | 220 V / 50 Hz |
| Noise Reduction Lid | Included |
| Manual Drain Valve | Yes |
| Construction | 304 Stainless Steel Tank & Argon-Welded Mesh Basket |
| Brand | PULUODY |
|---|---|
| Origin | Xi’an, Shaanxi, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Category | Domestic |
| Model | PS8011 |
| Instrument Type | Optical Particle Counter Sampling Vial |
| Capacity | 220 mL / 250 mL |
| Material | High-Silica Borosilicate Glass |
| Max. Temperature Resistance | 150 °C |
| Max. Pressure Resistance | 0.1 MPa |
| Cleanliness Grade | NAS 00–4 (per 100 mL) |
| AOQL (Average Outgoing Quality Limit) | 0.5% |
| RCL (Residual Contamination Level) | ≤15 particles ≥4 µm per 100 mL |
| Validated Standards | ISO 3722, GB/T 17484, NAS 1638, ISO 4406, SAE AS749D, ISO 16232, GJB 420A/B, GB/T 14039, DL/T 427, DL/T 1096 |
| Cleaning Process | Ultrasonic cleaning (high-precision), Class 100,000 cleanroom air shower, hot-air drying & hermetic sealing, UV sterilization, cleanliness verification |
| Seal | External-thread cap with O-ring drip-proof gasket |
| Compatibility | Fully compatible with HIAC ROYCO 8000A/8011/8012, PALL HPCA-Kit-O/HPCA-2/PIM400/PCM400/PFC400, SBSS, S40, and all ISO/NAS-compliant optical particle counters |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PS8011+ |
| Price Range | USD 135 – 525 |
| Material Options | PP, PE, PFA, PEEK, PFAD, High-Silica Borosilicate Glass |
| Volume Options | 50 mL to 1000 mL |
| Particle Cleanliness Level | RCL < 15 particles per 100 mL |
| Certified Cleanliness Classes | ISO Class 1–9 (per ISO 14644-1) |
| Particle Detection Thresholds | 0.1 µm, 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 5.0 µm |
| Average Outgoing Quality Limit (AOQL) | 0.5% |
| Compliance Standards | ISO 3722, ISO 14644-1, GB/T 17484, GB 50073-2001, JIS B9925:1997, JIS K0554:1995 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSC |
| Pricing | Available Upon Request |
| Detection Limit | 1 µg/mL / 0.01 FU / 0.01% |
| Measurement Speed | ≥50 Hz (up to 1000 data points/sec) |
| Resolution | 0.01% / 0.01 FU / 0.1 mg/mm² |
| Accuracy | ±0.5% of reading |
| Excitation Source | Dynamic X-ray Fluorescence (XRF) with 150 µW output |
| Measurement Spot Size | 0–1.5 mm or 0–5 mm |
| Working Distance | 3.5–4.5 mm or 20 mm |
| Oil Film Thickness Range | 0–9950 mg/mm² |
| Fluorescence Units (FU) Range | 0–1950 FU |
| Calibration Traceability | NIST- or GBW-certified reference materials |
| Compliance | OIML R 111-1 traceable via NIM (China) and NIST (USA) |
| Data Interface | RS-485 or RS-232 |
| Power Supply | Rechargeable battery or 220 V AC adapter |
| Brand | PULUODY |
|---|---|
| Model | PSC-3A |
| Origin | Shaanxi, China |
| Detection Principle | Fluorescence Energy Spectroscopy (FES) |
| Measurement Range | 0.01 FU (RFU) to full-scale fluorescence response |
| Detection Limit | 1 µg/mL (for representative hydrocarbon standards) |
| Response Time | 0.1–30 s per measurement |
| Sampling Rate | Up to 1000 data points/second |
| Output Units | Standardized Fluorescence Units (FU), % relative to calibration reference, or user-defined scale |
| Sample Compatibility | Flat or moderately curved solid surfaces (metals, composites, ceramics, plastics) contaminated with petroleum-based oils, synthetic lubricants, greases, hydraulic fluids, and other fluorescent organic residues |
| Compliance | Designed for alignment with ISO 8502-9 (Surface cleanliness by fluorescence), ASTM D7474 (Standard Test Method for Determination of Oil and Grease in Wastewater by Infrared Spectrophotometry — adapted for surface residue quantification via fluorescence correlation), and GLP/GMP-relevant data integrity practices |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSC-3A |
| Instrument Type | Optical Fluorescence-Based Particle & Contaminant Analyzer |
| Detection Principle | Fluorescence Energy Spectroscopy (FES) |
| Measurement Range | 0–100% relative oil contamination |
| Resolution | 0.01% / 0.01 FU / 0.1 mg/mm² |
| Accuracy | ±0.5% of reading |
| Detection Speed | ≥50 measurements/sec |
| Excitation Source | Dynamic X-ray Fluorescence (XRF), 150 µW |
| Measurement Spot Size | Adjustable (1–5 points), spot diameter 0–1.5 mm or 0–5 mm |
| Working Distance | 3.5–4.5 mm or 20 mm |
| Calibration Traceability | NIST- and GBW-certified reference standards |
| Compliance | OIML R 127 (surface contamination metrology), ISO 8502-3 (surface cleanliness), ASTM D7619 (fluorescent residue quantification) |
| Optional Module | Integrated particle counting (size ranges: A: 0.1–10 µm, B: 1–20 µm, C: 5–50 µm) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PSC-3A-1 |
| Price | USD 31,800 (approx.) |
| Measurable Contaminants | Oils, greases, coolants, cutting fluids, waxes (C5–Cn hydrocarbons) |
| Cleanliness Scale | 0–100% relative contamination level |
| Resolution | 0.01% |
| Accuracy | ±0.5% |
| Fluorescence Units (FU) | 0–1950 FU |
| FU Resolution | 0.01 FU |
| FU Accuracy | ±0.5% |
| Oil Film Thickness | 0–9950 mg/mm² |
| Thickness Resolution | 0.1 mg/mm² |
| Thickness Accuracy | ±0.5% |
| Measurement Spot Diameter | 0–1.5 mm or 0–5 mm (selectable) |
| Working Distance | 3.5–4.5 mm or 20 mm (dual-mode optical path) |
| Excitation Source | Dynamic X-ray Fluorescence (XRF) |
| Excitation Power | 150 µW |
| Detection Frequency | ≥50 Hz |
| Calibration Reference | Surface-specific calibration supported |
| Metrological Traceability | Certified reference materials traceable to GBW (China) and NIST (USA) |
| Calibration Modes | Auto-calibration, manual calibration, multi-point calibration |
| Measurement Points | 1–5 points per sample (user-configurable) |
| Communication Interface | RS-485 or RS-232 |
| Control Platform | PC-based or industrial computer |
| Power Supply | Rechargeable Li-ion battery or AC adapter (220 V AC) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PSC-3B |
| Price | USD 39,800 (FOB) |
| Measurement Principle | Fluorescence Energy Spectroscopy (FES) |
| Detection Target | Hydrocarbon-based contaminants (mineral oils, synthetic lubricants, cutting fluids, greases, waxes |
| Quantification Units | % relative cleanliness, FU (Fluorescence Units), mg/mm² oil film thickness |
| Detection Limit | 1 µg/mL equivalent surface concentration |
| Resolution | 0.01% / 0.01 FU / 0.1 mg/mm² |
| Accuracy | ±0.5% of reading |
| Measurement Time | 0.1–30 s per point |
| Spot Size Options | Ø1.5 mm or Ø5 mm |
| Working Distance | 3.5–4.5 mm (standard) / 20 mm (extended) |
| Excitation Source | Dynamic X-ray fluorescence (XRF) module |
| Excitation Power | 150 µW |
| Sampling Rate | ≥50 Hz |
| Calibration Traceability | NIST-traceable or GBW-certified reference standards |
| Calibration Modes | Auto-calibration, manual zero/baseline, multi-point curve calibration |
| Data Interface | RS-485 / RS-232 |
| Control Platform | PC-based or industrial computer |
| Power Supply | Rechargeable Li-ion battery or AC adapter (100–240 VAC) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSC-3C |
| Price | USD 34,500 (FOB) |
| Sensor | 7th-Generation Dual-Laser Narrow-Beam Particle Detector (Lifetime > 200,000 measurements) |
| Detectable Particle Sizes | Configurable Channels — A: 0.3/2.5/10 µm |
| B | 0.3/(0.5/1.0/2.5/5.0)/10 µm |
| C | 0.3/0.5/1.0/2.5/5.0/10 µm |
| D | 0.5/1.0/1.5/2.0/2.5/3.0 µm |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Airflow Rate | 2.83 L/min (0.1 cfm), adjustable |
| Sampling Duration | 30 s per measurement |
| Measurement Modes | Timed or Continuous Cycling |
| Alarm Types | User-Defined Particle Count & Mass Thresholds |
| Data Storage | 100,001 records (real-time or scheduled) |
| Communication | RS232, USB, RS485 |
| Power | Rechargeable 4100 mAh Li-polymer battery or 220 V AC adapter |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Measurement Points | 1–5 per surface area |
| Calibration Traceability | NIM (China) and NIST (USA) certified reference materials per GBW and ISO/IEC 17025 protocols |
| Compliance | GB/T 16292–1996, ISO 14644-1:2015 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-250 |
| Sample Volume Options | 100–1000 mL (customizable, including food-grade, pharmaceutical-grade, sterile, and corrosion-resistant variants) |
| Tubing Diameter | 4–8 mm (customizable) |
| Maximum Vacuum Pressure | 2 kPa |
| Tubing Compliance | NAS 1638 Class 0 |
| Cleaning Bottle Cleanliness | NAS 1638 Classes 0–4 (customizable) |
| Material Options | LC super-hard aluminum alloy (zinc-plated for corrosion resistance) or engineering-grade polymer (molded, hermetic seal) |
| Standards Compliance | GB/T 17489–1998, QC/T 29105.3–1992, DL/T 571–2007 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer | Producer |
| Country of Origin | Domestic (China) |
| Model | PSD-250 |
| Instrument Type | Optical Particle Counter Accessory |
| Material | LC Super-Hard Aluminum Alloy |
| Surface Treatment | Zinc Plating for Corrosion Resistance |
| Capacity | 250 mL |
| Operating Vacuum Pressure | 2 kPa |
| Compliance | GB/T 17489–1998, Q/CT 29105.3–1992, DL/T 571–2007 |
| Sampling Vessel Cleanliness Grade | NAS 1638 Class 0 |
| Cleanliness Performance | ≤15 particles ≥4 µm per 100 mL (RCL ≤15/100mL) |
| Tubing Specification | NAS 1638 Class 0 fluoropolymer tubing |
| Included Components | 1 × negative-pressure sampling gun, 1 × 250 mL NAS Class 0 clean bottle, 1 × NAS Class 0 tubing (length adjustable) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-250 |
| Pricing | Upon Request |
| Material | LC Super-Hard Aluminum Alloy |
| Capacity Options | 100–1000 mL (customizable for food-grade, pharmaceutical-grade, sterile, and corrosion-resistant applications) |
| Tubing Diameter | 4 mm / 6 mm / 8 mm (customizable) |
| Max Vacuum Pressure | 2 kPa |
| Tubing Compliance | NAS 1638 Class 0 |
| Cleaning Bottle Grade | NAS 1638 Classes 0–4 (customizable) |
| Standards | GB/T 17489–1998, Q/CT 29105.3–1992, DL/T 571–2007 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-250C |
| Price | USD 1,700 (est.) |
| Particle Detection Range | 0.05–10 µm |
| Sample Throughput Capacity | 1,000 configurable size channels |
| Flow Rate | 5–1500 mL/min |
| Flow Accuracy | < ±1% |
| Sample Volume Handling | 100 mL – 100 L |
| Viscosity Range | 0–99 cSt (offline), up to 500 cSt (pressurized) |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Detection Principle | Dual-Laser Obstruction (Light Blockage) |
| Sensor Generation | 8th-Generation Dual-Narrow-Beam Laser Particle Sensor |
| Calibration Standards | GBW Reference Materials, CN-PSL, CN-ISO, CN-NIST Traceable |
| Compliance | ISO 11171, ISO 4406, ASTM D7619, USP <788>, JIS B 9921, SEMI F39, IEC 60404-16 |
| Output Interfaces | RS232 / RS485 (MODBUS RTU), USB, LAN, 4–20 mA analog |
| Software Platform | CCACS 2.0 Integrated Analysis Suite |
| Control Architecture | Industrial PC or Embedded IPC with Military-Grade HMI |
| Display | Color LCD Touchscreen + Keyboard/Mouse Support |
| Reporting | Particles/mL + ISO 4406 / NAS 1638 / SAE AS4059 / GJB 420B Class Codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-351B |
| Price | USD 1,620 (approx.) |
| Applicable Standards | SY/T 5329–2012, GB 11901–1989, GB/T 11133, GB/T 606, GB 7600 |
| Gas Source | Nitrogen (user-supplied or optional integrated regulator) |
| Filtration Area | φ43 mm polymer membrane |
| Sample Volume Capacity | 3500 mL |
| Dimensions (W×D×H) | ≤500×500×800 mm |
| Temperature Monitoring | Digital thermometer with ambient display |
| Timing Method | Precision stopwatch integration |
| Filtration Control | Integrated pressure regulation, bleed valve, inlet/outlet valves, pressure gauge |
| Membrane De-aeration Function | Yes |
| Construction Materials | Borosilicate organic glass, 316 stainless steel, corrosion-resistant fittings |
| Compliance | Designed for GLP-compliant suspended solids quantification per gravimetric methodology |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-351B |
| Gas Source | Nitrogen (optional) |
| Filtration Membrane Diameter | φ43 mm |
| Sample Volume Capacity | 3500 mL |
| Dimensions (W×D×H) | ≤500×500×800 mm |
| Compliance Standards | SY/T 5329–2012, GB 11901–1989, GB/T 606, GB/T 11133, GB 7600 |
| Brand | PULUODY |
|---|---|
| Model | PSD-351B |
| Origin | Shaanxi, China |
| Instrument Type | Laboratory Water Quality Analyzer |
| Application Scope | Surface Water, Groundwater, Domestic Wastewater, Industrial Effluent, Oilfield Injection Water |
| Compliance Standards | SY/T 5329–2012, GB 11901–1989, GB/T 606–2006, GB/T 11133–2015, GB 7600–2014 |
| Gas Source | Nitrogen (externally supplied or optional integrated regulator) |
| Filter Diameter | φ43 mm |
| Housing Materials | Corrosion-resistant stainless steel + optical-grade acrylic |
| Pressure Regulation | Integrated pressure-reducing valve, precision pressure gauge, and dual-stage flow control valves |
| Temperature Monitoring | Digital electronic thermometer (±0.5 °C accuracy) |
| Timing | Manual stopwatch interface with synchronized logging capability |
| Membrane De-airing Function | Integrated venting mechanism to eliminate air bubbles on membrane surface |
| Filtration Mode | Constant-pressure gravimetric filtration |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | PSD-351B Microfiltration Membrane Filtration Tester |
| Price | USD 1,600 (approx.) |
| Applicable Standards | SY/T 5329–2012, GB 11901–1989, GB/T 606–2003, GB/T 11133–2015, GB 7600–2008 |
| Gas Source | Nitrogen (user-supplied or optional integrated regulator) |
| Filter Diameter | φ43 mm |
| Sample Volume Capacity | 3500 mL |
| Dimensions (W×D×H) | ≤500 × 500 × 800 mm |
| Construction Materials | Borosilicate organic glass, 316 stainless steel, and corrosion-resistant polymer components |
| Temperature Monitoring | Digital electronic thermometer (±0.5 °C accuracy) |
| Timing Method | Precision digital stopwatch (0.01 s resolution) |
| Pressure Control | Adjustable inlet pressure regulator with dual-stage precision gauge (0–1.0 MPa range) |
| Filtration System | Integrated bubble-venting filter housing with standardized membrane support and sealing mechanism |
| Drain/Exhaust Valves | Stainless steel needle valves with calibrated flow restriction |
| Compliance | Designed for GLP-compliant suspended solids quantification in environmental and petroleum water quality labs |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-351B |
| Instrument Type | Portable Water Quality Analyzer |
| Detection Targets | Surface Water, Groundwater, Domestic Wastewater, Industrial Effluent, Oilfield Injection Water |
| Applicable Standards | SY/T 5329–2012, GB 11901–1989, GB/T 7600, GB/T 11133, GB/T 606 |
| Gas Source | Nitrogen (optional or customer-supplied) |
| Filter Diameter | φ43 mm |
| Sample Volume Capacity | 3500 mL |
| Dimensions (L×W×H) | ≤500×500×800 mm |
| Construction Materials | Organic Glass (PMMA), Stainless Steel, Corrosion-Resistant Components |
| Pressure Regulation System | Integrated Inlet Pressure Control with Relief Valve, Pressure Gauge, Inlet/Outlet Valves |
| Temperature Measurement | Digital Thermometer |
| Timing Method | Precision Stopwatch |
| Filtration Module | Bubble-Elimination Enabled High-Molecular-Weight Membrane Holder |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-650 |
| Price | USD 2,500 (FOB) |
| Compliance | GB/T 7597, IEC 60475, ASTM D923 |
| Temperature Sensor | PT100 (±0.5 °C accuracy) |
| Power | Replaceable Battery |
| Design | Physically Isolated Sampling Tube & Display Module |
| Sampling Method | Continuous Flushing Capability |
| Form Factor | Integrated Compact Assembly with Multi-Valve Control |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-650 |
| Price | USD 2,500 (FOB) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PSD-650 |
| Price | USD 2,500 (approx.) |
| Sampling Volume Range | 100–1000 mL |
| Temperature Measurement Range | −20 °C to 200 °C |
| Temperature Sensor Accuracy | ±0.5 °C (PT100 embedded probe) |
| Compliance | IEC 60475, ASTM D923, GB/T 7597 |
| Core Components | Two gas-tight glass syringes (standard 100 mL), two 600 mL aluminum sample cylinders, dual-port valves, 1 m PVC sampling hose, insulated carrying case with foam inserts |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF100-1A-0.5 |
| Dimensions | 360 × 450 × 580 mm |
| Cleanliness Classes | ISO Class 4 (10 particles/ft³ ≥0.1 µm), ISO Class 5 (100 particles/ft³ ≥0.5 µm) |
| Airflow Velocity | 0.25 m/s |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Lighting | Fluorescent Lamp |
| Sterilization | UV-C Germicidal Lamp |
| Optional Accessories | Pneumatic Rotary Stage (bidirectional), High-Purity Nitrogen Inlet with Particle Filter, Adjustable Gooseneck Nozzle |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF100-1A-0.5 |
| Dimensions | 360 × 450 × 580 mm |
| Cleanroom Class | ISO Class 4 (10-class) & ISO Class 5 (100-class) |
| Air Velocity | 0.25 m/s |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| Lighting | Fluorescent Lamp |
| Sterilization | UV-C Lamp (254 nm) |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Construction | Powder-coated steel frame with 304 stainless steel work surface |
| Optional Accessories | High-purity nitrogen inlet with inline filter, articulated nitrogen delivery hose, motorized bidirectional sample rotation stage |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF100-1A-0.5 |
| Cleanroom Class | ISO Class 4 (10-grade) & ISO Class 5 (100-grade) |
| Airflow Configuration | Horizontal or Vertical Laminar Flow |
| Filtration | Dual-stage — Pre-filter + HEPA (H14, ≥99.995% @ 0.3 µm) |
| Operating Air Velocity | 0.25 m/s ±10% |
| Vibration Amplitude | ≤3 µm |
| Sound Pressure Level | ≤67 dB(A) |
| UV Germicidal Lamp | 254 nm, 15 W |
| Illumination | Fluorescent, ≥300 lx |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Ambient Temp. | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Dimensions (W×D×H) | 360 × 450 × 580 mm |
| Construction | Powder-coated steel frame, 304 stainless steel work surface |
| Optional Accessories | High-purity nitrogen inlet with inline filter, articulated nitrogen purge nozzle, programmable bidirectional sample rotator |
| Brand | PULUODY |
|---|---|
| Model | PSD-PF10A-0.5 |
| Origin | Shaanxi, China |
| Instrument Type | Optical Particle Counter Integrated Clean Bench |
| Cleanliness Class | ISO Class 4 (Equivalent to Federal Standard 209E Class 10) |
| Airflow Velocity Range | 0.25–0.6 m/s (Adjustable via Control Panel) |
| Vibration Amplitude | ≤3 µm (Operational) |
| Noise Level | ≤67 dB(A) |
| UV Sterilization Cycle | 15 min for Surface Bioburden Reduction |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF10A-0.5 |
| Cleanliness Class | ISO Class 4 (10 particles ≥0.1 µm per cubic foot) |
| Airflow Velocity | 0.25–0.6 m/s (adjustable) |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| UV Sterilization Time | 15 min for microbial reduction |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PSD-PF10A-0.5 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Cleanroom Classification | ISO Class 4 (Equivalent to Federal Standard 209E Class 10) |
| Repeatability | ±1% |
| Measurement Time | 15 s |
| Airflow Velocity Range | 0.25–0.6 m/s (adjustable) |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| UV Sterilization Cycle | 15 min for microbial reduction to sterile conditions |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF10A-0.5 |
| Cleanliness Class | ISO Class 4 (10 particles ≥0.1 µm per cubic foot) |
| Airflow Velocity | 0.25–0.6 m/s (adjustable) |
| Vibration Amplitude | ≤3 µm |
| Operating Noise | ≤67 dB(A) |
| UV Sterilization Time | 15 min for microbiological decontamination |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Ambient Temp. | 10–30 °C, RH ≤75%, low-vibration, low-dust environment |
| Construction | Fully welded steel frame with epoxy powder coating, 304 stainless steel work surface |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Counter |
| Measurement Range | 1–500 µm (0.03–3000 µm optional) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Measurement Time | 60 seconds |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PST-890 |
| Price | USD 53,200 (approx. ¥380,000) |
| Sensor Generation | 8th-Gen Dual-Laser Narrow-Beam Detector |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Software | V8.9 Integrated Particle Analysis Suite (PC & Embedded Touch UI) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Environmental Operating Range | −15–50 °C |
| Counting Channels | 1000 configurable channels (user-definable from 4 to 128 size bins) |
| Detection Range | 1–450 µm (extended range 0.03–3000 µm optional) |
| Custom Ranges | 1–100 µm, 4–70 µm(c), 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP <788>, ISO 21501-4) |
| Compliance | GB/T 11446.9–2013, ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, IP 2015, WHO IntPh IV, YBB 00272004–2015, GB 8368, ISO 21510, ISO 11171, NAS 1638, ISO 4406, SAE AS4059, MIL-STD-1246C, JIS B 9933, IP 564/565, ROC T 17216, GB/T 14039, DL/T 432, DL/T 1096, JB/T 9737, GJB/T 420A/B, GB/T 18854 |