PULUODY
Filter
Showing 61–90 of 412 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | OPC-3 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246C, GJB 420B, GB/T 14039, GOST 17216 |
| Pressure Rating | 0–1.0 MPa (standard), up to 31.5 MPa (with pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB contamination grade |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-5 |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GB/T 14039, DL/T 432, GOST 17216 |
| Pressure Rating | 0–1.0 MPa (direct), 0–31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature | −10 to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V |
| Power Supply | 9–30 VDC |
| Enclosure Rating | IP65 |
| Calibration Support | NIST-traceable reference calibration available annually |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-6 |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GB/T 14039, DL/T 432, GOST 17216 |
| Max. Operating Pressure | 31.5 MPa (with pressure regulator) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB Grade Code |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-7 |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GB/T 14039, GOST 17216 |
| Pressure Rating | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB contamination code |
| Calibration Support | NIST-traceable reference materials, annual recalibration assistance provided |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | OPC-Ex |
| Instrument Type | Optical Particle Counter |
| Explosion Protection | Intrinsic Safety (Ex ia IIC T4 Ga) |
| IP Rating | IP40 to IP65 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Measurement Range | 1–150 µm |
| Channel Configurations | Fixed 8-channel or 16-channel (customizable 1–100 µm) |
| Calibration Standards Supported | NAS 1638 (00–>12), ISO 4406 (00–>28), GJB 420B (00–>12), GOST 17216 (00–>17), GB/T 14039, ISO 11171, MIL-STD-1246, SAE AS4059, IP 564/565, DL/T 432 & 1096, JB/T 9737, GB/T 18854 |
| Operating Pressure | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure-reduction valve) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt (online) |
| Analog/Digital Outputs | RS232, RS485, 4–20 mA, 0–5 V (customizable with alarm relay) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB-based contamination grade |
| Compliance | Meets IEC 60079-0/-11 for intrinsic safety |
| aligned with ISO 4402 (historical) and ISO 11171 | 2010 reference calibration protocols |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-EX-1 |
| Price | USD 27,800 (approx.) |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Technology (7th Generation) |
| Particle Size Range | 1–150 µm |
| Calibration Standards Supported | ISO 4406, NAS 1638, GJB 420B, GOST 17216, SAE AS4059, ISO 11171, MIL-STD-1246, IP 564/565, GB/T 14039, DL/T 432, JB/T 9737, GB/T 18854 |
| Operating Pressure | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Enclosure Rating | IP40 to IP65 |
| Explosion Protection | Intrinsic Safety (Ex ia IIC T4 Ga) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB contamination grade |
| Channel Configuration | Fixed 8-channel or 16-channel (customizable) |
| Accuracy Class | ±0.6 per ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-VI |
| Price | USD 40,200 (FOB) |
| Core Principle | Light-Blocking (Obscuration) Particle Counting |
| Compliance Standards | ISO 11171:1999, ISO 4406:2023, NAS 1638, GB/T 18854–2002, GB/T 14039, MIL-STD-1246C, GJB 420B, DL/T 432 |
| Detection Channels | User-Configurable, up to 24 size thresholds (e.g., ≥4 µm(c), ≥6 µm(c), ≥14 µm(c), ≥21 µm(c), ≥38 µm(c), ≥70 µm(c)) |
| Output Signal | 4–20 mA analog per sensor channel |
| Communication Interface | RS232, optional RS485/Modbus RTU |
| Operating Temperature | –20 °C to +70 °C |
| Fluid Compatibility | Mineral oils, synthetic lubricants, phosphate ester hydraulic fluids, aviation fuels, transformer oil, turbine oil, gear oil, hydraulic fluid (water-glycol & water-oil emulsions), ultra-pure water, aggressive solvents (pH 2–12) |
| Sensor Modules | Particulate (light-blocking), ferrous/non-ferrous wear debris (inductive), water activity (capacitive), viscosity (oscillating piston), density (vibrating U-tube), dielectric constant, pressure, flow rate, temperature |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | OPCI Series |
| Price | ¥58,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 1–150 µm |
| Repeatability | ±1% |
| Measurement Time | 10 s |
| Brand | PULUODY |
|---|---|
| Model | P-ICP |
| Origin | Shaanxi, China |
| Power Supply | 800–1600 W |
| Power Stability | ≤0.2% |
| Detection Limit | down to 1 ppb (µg/L) |
| Repeatability (RSD) | ≤1.5% |
| Stability (RSD) | ≤2.0% |
| Accuracy | ±3% (method-dependent) |
| Spectral Range | 190–800 nm |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Sample Volume Required | >1 mL |
| Operating Temperature | 20–45 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Elemental Coverage | ≥61 elements |
| Analysis Speed | ≥4 elements per minute |
| Linear Dynamic Range | 5 orders of magnitude |
| Certified Standards Compliance | ASTM D6595, ASTM D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | P-ICP |
| Product Category | Laboratory Instrument |
| Analytical Method | Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES) |
| Compliant Standards | ASTM D6595, ASTM D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Customizable Detection Channels | 1000 channels |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Rotating Disc Electrode (RDE) Atomic Emission Spectrometer |
| Sample Introduction | Direct liquid introduction |
| Waste Disposal | Rear exhaust configuration |
| Atomization Mode | Vapor generation / Hydride generation |
| Detectable Elements | Al, Ba, B, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Mo, Ni, P, Si, Ag, Na, Sn, Ti, V, Zn, K, Li, Sb, Sr, Bi, As, In, Zr, W, Co, Ce |
| Detection Limit | ≤1 ppb (μg/L) for most elements |
| Precision | RSD ≤1.5% |
| Stability | RSD ≤2.0% |
| Linear Dynamic Range | 5 orders of magnitude |
| Spectral Range | 190–800 nm |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (±0.05%) |
| RF Power Output | 800–1600 W (±0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Minimum Sample Volume | >1 mL |
| Operating Temperature | 20–45 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Software | PICP-V2.1 multi-language platform (CN/EN/KO/JP), compliant with ASTM D6595, D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Brand | PULUODY |
|---|---|
| Model | P-ICP-II |
| Origin | Shaanxi, China |
| Detection Principle | Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES) |
| Spectral Range | 190–800 nm |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (stability ≤0.05%) |
| RF Power Output | 800–1600 W (stability ≤0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Sample Volume Required | >1 mL |
| Operating Temperature | 20–45 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Elemental Detection Capability | ≥61 elements |
| Detection Limit | down to 1 ppb (µg/L) for most metals |
| Linear Dynamic Range | 5 orders of magnitude |
| Analysis Speed | ≥4 elements per minute |
| Precision (RSD) | ≤1.5% |
| Stability (RSD) | ≤2.0% |
| Accuracy | ±3% (method-dependent) |
| Compliance Standards | ASTM D6595, ASTM D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Multi-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Direct Nebulization |
| Waste Disposal | Rear Exhaust Design |
| Gas Flow Control | Rotameter-Based Pneumatic System |
| Detectable Elements | Al, Ba, B, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Mo, Ni, P, Si, Ag, Na, Sn, Ti, V, Zn, K, Li, Sb, Sr, Bi, As, In, Zr, W, Co, Ce |
| Relative Standard Deviation (RSD) | <1% |
| Linear Dynamic Range | 5 orders of magnitude (0.01–10,000 µg/L) |
| Detection Limits | Sub-ppb (≤0.01 µg/L) for most elements |
| Photomultiplier Tube Wavelength Range | 200–1000 nm |
| Atomizer Temperature Control Range | Ambient to 45 °C |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (stability ≤0.05%) |
| RF Power Output | 800–1600 W (stability ≤0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Sample Volume Requirement | >1 mL |
| Operating Temperature | 15–45 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Brand | PULUODY |
|---|---|
| Model | P-III |
| Instrument Type | Optical Surface Particle Counter |
| Detection Principle | Light Scattering (Laser-Based) |
| Particle Size Channels | Configurable across 6 channel sets (A–F), ranging from 0.1 µm to 25.0 µm |
| Size Accuracy | ≤ ±30% |
| Concentration Accuracy | ≤ ±30% |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | ≤ 5% |
| Flow Rate Options | 2.83 L/min or 28.3 L/min |
| Sampling Duration | 3–60 s (user-selectable) |
| Operating Temperature | −40 °C to +120 °C |
| Environmental Operating Range | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1, ISO 14644-9 |
| Data Interface | RS232, RS485, LAN, USB |
| Audit Trail & User Access Control | Yes |
| Detection Modes | Count, Mass, Net Efficiency |
| Alarm Output | Customizable count/mass thresholds |
| Storage | Real-time and scheduled (unlimited capacity) |
| Optional Accessories | Straight probe (2″), 90° angled probe, multifunctional surface probe (UK4400301) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PCS-3A |
| Application | Handheld/Portable |
| Element Detection Range | C₅–Cₙ organic compounds |
| Quantification Range | 1–2000 (unitless relative scale) |
| Energy Resolution | 0.01 FU (Fluorescence Unit) |
| Repeatability | ≥99% |
| Detector Type | X-ray-excited ultraviolet fluorescence (XUVF) detector |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PDM-301A |
| Instrument Type | Laboratory Benchtop Digital Densimeter |
| Measurement Principle | Oscillating U-Tube Method |
| Sample Type | Liquids Only |
| Density Range | 0.0000–3.0000 g/cm³ |
| Density Resolution | ±0.0001 g/cm³ |
| Density Repeatability | ±0.0002 g/cm³ |
| Temperature Control Range | 15–30 °C |
| Temperature Stability | ±0.1 °C |
| Minimum Sample Volume | 10 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D3505, ISO 12185, GB/T 29617, GB/T 2013, SH/T 0604, SN/T 2383, DB/T 1231, JJG 1058 |
| Brand | PULUODY |
|---|---|
| Model | PDM-301A |
| Measurement Principle | Oscillating U-tube |
| Density Range | 0–3.0000 g/cm³ |
| Resolution | ±0.0001 g/cm³ |
| Repeatability | ±0.0002 g/cm³ |
| Temperature Control Accuracy | ±0.1 °C |
| Thermostatic Range | 15–30 °C |
| Power Supply | 220 V ±10%, 50 Hz |
| Sample Volume | 2–3 mL |
| Data Storage Capacity | >20,000 records |
| Display | LCD |
| Dimensions | 206 × 205 × 200 mm |
| Compliance | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, SN/T 2383–2009, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, IP 559–2008, JJG 1058–2010 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PGS-OC1 |
| Price | USD 3,950 (FOB) |
| Measurement Principle | Electrochemical (Galvanic Cell) |
| Range | 0.0–10 / 100 / 1000 ppm O₂ (selectable) |
| Accuracy | ≤ ±2% FS |
| Sample Flow Rate | 400 ± 10 mL/min |
| Inlet Pressure Range | 0.05–0.5 MPa |
| Response Time (T₉₀) | ≤ 60 s |
| Display | 128×64 OLED, monochrome, high-brightness |
| Data Storage | 3200 records with trend curve |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% (charger) |
| Built-in Sampling Pump | Yes |
| Operating Temperature | –5 °C to +45 °C |
| Operating Humidity | ≤ 90% RH (non-condensing) |
| Alarm Output | User-configurable threshold (factory default: 5 ppm O₂) |
| Compliance | Designed for ISO 8573-3, ASTM D6299, and GLP-aligned field verification workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-0175B |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Heating Power | 1500 W |
| Temperature Control Accuracy | ±0.1 °C |
| Bath Capacity | 4 Test Positions |
| Oxygen Flow Control | Calibrated Precision Flowmeter |
| Cooling Method | Integrated Drain Valve + Forced-Air Fan |
| Operating Environment | Dark Chamber Enclosure |
| Compliance Standard | SH/T 0175 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-0193A |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Main Heating Power | 1500 W |
| Auxiliary Heating Power | 1200 W |
| Pressure Gauge Range | 0–1500 kPa |
| Pressure Gauge Accuracy | ±0.2% FS |
| Oil Bath Temperature Range | 100–160 °C |
| Oil Bath Temperature Stability | ±0.1 °C |
| Printer Model | TpuP-A40PB |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-0193A |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Main Heating Power | 1500 W |
| Auxiliary Heating Power | 1200 W |
| Pressure Gauge Range | 0–1500 kPa |
| Pressure Gauge Accuracy | ±0.2% FS |
| Oil Bath Temperature Range | 100–160 °C |
| Oil Bath Temperature Stability | ±0.1 °C |
| Printer Model | TpuP-A40PB |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Optical Particle Counter |
| Model | PLD-0201 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Measurement Range | 0.01 µm – 1000 µm (configurable sensor modules) |
| Channel Resolution | Up to 1000 user-definable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Flow Control | Dual-mode precision piston pump + ultra-precise electromagnetic flow regulation |
| Viscosity Handling | ≤ 450 mm²/s |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (cleaning) |
| Pressure Range | −0.08 to 0.8 MPa (integrated positive/negative pressure pretreatment) |
| Operating Temperature | Ambient to 65 °C (sample), 0–50 °C (ambient) |
| Data Storage | 3000 tests onboard |
| Compliance Standards | ISO 11171, ISO 4402, ISO 4406, NAS 1638, GB/T 14039, GB/T 18854, JJG/T 066, DL/T 432, GJB 380, GJB 420A/B, MIL-STD-1246, ASTM D6786, USP <788> & <789> (via optional configuration) |
| Software Platform | PULL 8.1 Multi-Language Analysis Suite (English, Chinese, Japanese, Korean, German, French, Spanish, Russian, Arabic, Portuguese) |
| Output Interface | RS232, integrated thermal printer, capacitive touchscreen (7″ color LCD), dual-input (touch + keypad), iPad-compatible data acquisition module |
| Brand | PULUODY |
|---|---|
| Model | PLD-0201 |
| Type | Optical (Light Obscuration) Particle Counter |
| Measurement Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Detection Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Channels | 8 user-configurable size channels |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min |
| Test Duration | Adjustable, down to 12.5 s |
| Viscosity Limit | ≤350 cSt |
| Operating Temperature | Ambient to 65°C |
| Pressure Range | −0.6 to +0.7 kPa (integrated dual-pressure pretreatment system) |
| Compliance Standards | ISO 4406, NAS 1638, GJB 420B, GJB 380, GB/T 14039, GB/T 18854, ISO 11171, ASTM D6786 |
| Calibration Traceability | Certified by China National Defense Science & Technology Commission Level-1 Particle Metrology Station No. 116 |
| Data Output | Real-time particle count per channel, size distribution histogram, contamination grade assignment, RS232 interface, built-in thermal printer |
| Software | P6.4 Analysis Suite (PC & embedded industrial control versions) |
| Control Interface | Integrated capacitive touchscreen LCD |
| Auto-Cleaning Function | Yes |
| Power | 220 VAC, 50 Hz, <80 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measuring Range | 0.5–1000 µm (sensor-dependent) |
| Compliance Standards | ISO 4406, NAS 1638, MOOG, DL/T 1096, GJB 380, DL/T 432, ISO 11500 |
| Control System | Integrated Industrial PC or Embedded Controller |
| Sample Volume | 1 mL to unlimited (programmable) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Display | Touchscreen LCD with Dual Input (Touch + Keypad) |
| Data Output | RS232 Serial Interface |
| Built-in Printer | Yes |
| Software | P6.4 Particle Analysis Suite (Embedded & PC Versions) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 1–450 µm |
| Repeatability | <5% |
| Measurement Time | 20 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | 1000 channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Flow Rate | 5–60 mL/min |
| Rinse Flow Rate | 10–100 mL/min |
| Sample Volume Accuracy | ±1% |
| Test Duration | Adjustable, nominal 20 s per measurement |
| Pressure Range | −0.08 to 0.8 MPa (dual-polarity pre-conditioning system) |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C (sample), 0–50 °C (ambient) |
| Power Supply | 220 V, 50 Hz, <80 W |
| Data Storage | 3000 tests on embedded industrial PC |
| Compliance Standards | ISO 4406, ISO 11171, ISO 11500, NAS 1638, ASTM D6786, DL/T 432, DL/T 1096, GJB 420A/B, GJB 380, MIL-STD-1246, MOOG, USP <788>, and GB/T 14039 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Standard Compliance | ISO 4406, ISO 11171, NAS 1638, GB/T 18854, JJG/T 066, GJB 420B, DL/T 432 |
| Measurement Range | 0.01 µm – 1000 µm (sensor-dependent) |
| Channel Capacity | Up to 1000 adjustable size channels |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Sample Flow Control | Dual-mode precision piston pump + electromagnetic flow regulation |
| Viscosity Handling | ≤ 450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 MPa to +0.8 MPa |
| Sampling Volume Accuracy | ±1% |
| Test Duration | Configurable (standardized at 20 s per ISO 11500) |
| Data Storage | 3000 onboard tests |
| Interface | RS232, touchscreen GUI, integrated thermal printer |
| Software | PULL 8.1 multi-language platform (English, Chinese, Japanese, Korean, etc.), FDA 21 CFR Part 11–ready audit trail mode optional |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-0201 |
| Instrument Type | Optical Laser-Based Particle Counter |
| Detection Principle | Light Scattering (Dual-Laser Narrow-Beam Sensor, 8th Generation) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854, JJG 1061 |
| Compliance Standards | ISO 4406:1999/1987, NAS 1638, MOOG, DL/T 1096, ISO 11218, GJB 380, DL/T 432, ISO 11500 |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Detection Range | 0.03–3000 µm (sensor-dependent) |
| Channel Configuration | Up to 1000 user-configurable size channels |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Data Storage | 3000 tests on embedded industrial PC |
| Interface | RS232 |
| Output | Real-time particle count/mL, size distribution histogram, contamination grade per ISO/NAS, built-in thermal printer |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Control | Industrial PC or integrated touch-enabled HMI with color LCD |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter |
| Model | PLD-0201 (Serial: 02010086) |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 0.01 µm to 1000 µm (sensor-dependent) |
| Channel Capacity | Up to 1000 user-configurable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Viscosity Limit | ≤450 mm²/s |
| Flow Control | Dual-mode precision piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (rinse) |
| Pressure Range | −0.08 to 0.8 MPa |
| Operating Temperature | Ambient to 65 °C |
| Data Storage | 3000 tests onboard |
| Compliance Standards | ISO 11171, ISO 4406, ISO 4402, NAS 1638, GB/T 14039, GB/T 18854, JJG/T 066, GJB 420A/B, DL/T 432, DL/T 1096, MIL-STD-1246, ASTM D6786 |
| Software Platform | PULL 8.1 multi-language analytical suite (English, Chinese, Japanese, Korean, etc.) |
| Output Interface | RS232, integrated thermal printer, touchscreen GUI, iPad-compatible data acquisition |
| Calibration Support | ACFTD & MTD traceable calibration |
