Young Instruments
Filter
Showing 1–30 of 57 results
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HWP15-10S |
| Quotation | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Timing Range | 0–30 min |
| Timing Accuracy | ±0.01 s |
| Time Display Resolution | 1 s |
| Sample Volume | 2 mL |
| Drop Height | 1 m |
| Flame Detection Response Time | ≤6 ms |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | ATC 300A |
| Instrument Type | Bomb Calorimeter |
| Ignition Method | Cotton Thread & Ignition Wire |
| Temperature Resolution | 0.0001 °C |
| Test Mode | Isothermal |
| Test Duration | ≤15 min (Standard Method), ≤10 min (Rapid Method) |
| Calorific Value Range | ≤34,000 J |
| Heat Capacity Precision | ≤0.10% |
| Heat Capacity Drift | ≤0.20% |
| Oxygen Bomb Max Pressure | 240 bar |
| Bomb Material | Stainless Steel & Hastelloy (Corrosion-Resistant) |
| Data Storage Capacity | ≥10,000 Tests |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ATC 300A |
| Pricing | Available Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BAC-1000A |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | RT to 300 °C (–25 °C with optional low-temp module) |
| Adiabatic Chamber Dimensions | Ø420 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall-Sample Temperature Difference Control | 0.02–15 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Needle Penetration Stroke | Programmable |
| Current Capacity (Charge/Discharge Electrodes) | ±1000 A |
| Compliance Standards | GB/T 36276–2023, UL 9540A, SAE J2464–2009, ASTM E1981–98(2012), SN/T 3078.1–2012, UL 1973, SAND99-0497, FreedomCAR SAND2005-3123 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-420A |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter |
| Adiabatic Chamber Dimensions | Ø420 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall-Sample Temperature Difference Control | ≤0.5 °C |
| Temperature Control Range | RT to 300 °C |
| Temperature Tracking Rate | 0.02–13 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Nail Penetration Stroke | Software-Configurable |
| Current Handling Capacity (Charge/Discharge Electrodes) | ±500 A |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | BAC-420B |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Detection Threshold | < 0.02 °C/min |
| Temperature Tracking Rate | 0.02–13 °C/min |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-420R |
| Measurement Mode | Adiabatic Calorimetry |
| Adiabatic Chamber Dimensions | 420 × 520 mm (L × W) |
| Temperature Control Range | RT+5°C to 300°C (optional low-temp module down to −25°C) |
| Temperature Resolution | 0.001°C |
| Chamber Temperature Stability | ±0.05°C |
| Self-Heating Detection Sensitivity | 0.02–0.05°C/min |
| Temperature Tracking Rate | 0.02–13°C/min |
| Wall-to-Sample Temperature Difference (Isothermal Mode) | <0.5°C |
| Max Sample Length | 600 mm |
| Compliance | GB/T 36276-2023, GB 38031-2020, SN/T 3078.1-2012, SAE J2464-2009, SAND2005-3123, UL 9540A-2019, SAND99-0497-1999 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Model | BAC-800A |
| Compliance | GB/T 36276–2023, UL 9540A, SAE J2464-R2009, ASTM E1981–98(2012), UL 1973, SN/T 3078.1–2012, SAND99-0497, FreedomCAR SAND 2005-3123 |
| Adiabatic Chamber Dimensions | Ø800 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall–Sample Temperature Differential | ≤1 °C |
| Temperature Control Range | RT to 300 °C (with optional low-temperature module down to –25 °C) |
| Temperature Tracking Rate | 0.02–15 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Puncture Stroke | Software-Configurable |
| Current Capacity of Charging/Discharging Electrode Posts | ±500 A |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BAC-800B |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Adiabatic Chamber Internal Dimensions | Ø800 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall–Sample Temperature Difference | ≤1 °C |
| Temperature Control Range | RT to 300 °C (with optional low-temp module: –40 °C to 300 °C |
| Pressure Range | 0–2 MPa |
| Temperature Tracking Rate | 0.02–15 °C/min |
| Nail Penetration Max Stroke | Software-Configurable |
| Current Handling Capacity (Charge/Discharge Electrodes) | ±1000 A |
| Compliance Standards | GB/T 36276–2023, UL 9540A, SAE J2464–2009, ASTM E1981–98(2012), SN/T 3078.1–2012, UL 1973, SAND99-0497, FreedomCAR SAND2005-3123 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-800R |
| Compliance | GB/T 36276-2023, GB 38031-2020, SAE J2464-2009, UL 9540A-2019, SN/T 3078.1-2012, SAND 2005-3123, SAND 99-0497-1999 |
| Adiabatic Chamber Dimensions | 800 × 520 mm (L × W) |
| Temperature Control Range | RT+5°C to 300°C (optional low-temp module: –25°C) |
| Temperature Resolution | 0.001°C |
| Chamber Temperature Stability | ±0.05°C |
| Self-Heating Detection Sensitivity | 0.02–0.05°C/min |
| Temperature Tracking Rate | 0.02–15°C/min |
| Wall-to-Sample Temperature Difference (Isothermal Mode) | <1°C |
| Maximum Sample Length | ≤600 mm |
| Safety Features | Pressure Relief Valve + Mechanical Interlock on Lid |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BAC-90A |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | RT to 500 °C |
| Temperature Resolution | 0.001 °C |
| Chamber Dimensions | Ø90 mm × 110 mm depth |
| Temperature Tracking Rate | 0.005–40 °C/min |
| Minimum Detectable Temperature Rise Rate | 0.005–0.02 °C/min |
| Power Supply | 220 V / 50 Hz |
| Max Power Consumption | ≤3000 W |
| Data Interface | USB or RJ45 |
| Operating Environment | 5–40 °C, <85% RH |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | BIC-400A |
| Pricing | Upon Request |
| Automation | Fully Automated |
| Instrument Type | Isothermal Calorimeter |
| Measurement Principle | Power Compensation Isothermal Calorimetry |
| Temperature Range | −40 °C to 100 °C |
| Temperature Resolution | 0.001 °C |
| Thermal Enthalpy Measurement Accuracy | ±1% (Power Compensation Mode) |
| Baseline Noise | 10 mW (Power Compensation), 0.2 mW (Heat Flow Mode) |
| Maximum Sample Dimensions | 345 mm × 230 mm × 100 mm |
| Max Compensation Power | 200 W |
| Sensitivity | 10 mW (Power Compensation), 0.2 mW (Heat Flow) |
| Temperature Stability | ±0.005 °C (Oil Bath Operation) |
| Oil Bath Temp Range | −40 °C to 200 °C |
| Heating Power | 3 kW |
| Cooling Capacity | 1.5 kW @ 20 °C, 1.5 kW @ 0 °C, 1 kW @ −20 °C, 0.3 kW @ −40 °C |
| Circulation Flow Rate | 22–26 L/min |
| Dual-Stage Pump Pressure | 0.4–0.7 bar (Heating/Cooling Loop), 0.2–0.4 bar (Suction) |
| Bath Opening/Volume | 12 × 11 / 16 cm, 5 L |
| Communication Interface | RS-232 (RJ45 adapter available) |
| Optional Battery Cycler | 4-channel, ±400 A / 0–5 V, ±0.1% FS voltage & current accuracy, SOC estimation support |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Thermal Flow DSC |
| Temperature Range | RT to 700 °C |
| Heating Rate | 0.05–200 °C/min |
| Baseline Stability | ≤100 µW (100–300 °C, uncorrected) |
| Baseline Repeatability | ≤40 µW |
| Heat Flow Noise | <8 µW (peak-to-peak) |
| Enthalpy Accuracy | ±0.8% (In) |
| Enthalpy Precision | ±0.08% (In) |
| Phase Transition Temperature Accuracy | ±0.1 °C (In) |
| Phase Transition Temperature Precision | ±0.02 °C (In) |
| Indium Peak Height / FWHM | ≥20.0 mW/K |
| Sampling Frequency | 50 Hz |
| Heat Flow Range | ±750 mW |
| Gas Control | 3-channel, inert/oxidizing, static/dynamic, 0–300 mL/min |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Thermal Flow DSC |
| Sample Capacity | Single-sample |
| Temperature Range | –90 °C to 550 °C (with optional imported high-performance mechanical cryocooler) |
| Cooling Method | Mechanical refrigeration + air cooling |
| Heating/Cooling Rate | 0.05–200 °C/min (heating), 0.1–100 °C/min (cooling) |
| Temperature Accuracy | ±0.1 °C (In), Precision: ±0.02 °C (In) |
| Baseline Drift | ≤100 µW (–50–300 °C, no baseline correction) |
| Baseline Repeatability | ≤40 µW |
| Peak Noise (Heat Flow) | <8 µW |
| Enthalpy Accuracy | ±0.8% (In), Precision: ±0.08% (In) |
| Indium Peak Height/FWHM | ≥20.0 mW/K |
| Data Acquisition Rate | 50 Hz |
| Heat Flow Range | ±750 mW |
| Gas Control | 3-channel mass-flow-controlled atmosphere (inert/oxidizing, static/dynamic, 0–300 mL/min) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ECB-2002A |
| Price | Upon Request |
| Test Vessel Temp. Range | Ambient to 200 °C |
| Max. Design Pressure | ≥2.0 MPa |
| Explosion Pressure Sensor Range | ≥5.0 MPa, Linearity: ±1.0% FS |
| Pressure Sampling Rate | ≥5 kHz |
| Data Points per Test | ≥10,000 |
| Gas Inlet Channels | 3 |
| Max. Stirring Speed | 400 rpm (adjustable) |
| Operating Environment | −5–45 °C, <95% RH |
| Gas Pressure Control Accuracy | ±0.1% FS |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ECD-20A |
| Operating Principle | Pneumatic Dust Dispersion + Controlled Ignition (Chemical or Electrostatic) |
| Explosion Protection Rating | Ex d IIB T4 Gb |
| Relative Uncertainty | ±8.8% (per ISO/IEC 17025-compliant validation protocol) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | FCPP-80A |
| Pricing | Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FP CC-420A |
| Detection Method | Closed-Cup (Continuous) |
| Operation Mode | Fully Automatic |
| Temperature Range | 0 °C to 260 °C (–30 °C to 420 °C with optional low-/high-temperature modules) |
| Ignition Method | High-Voltage Electronic Spark |
| Heating Rate | 2.5 ± 0.3 °C/min, 5.5 ± 0.5 °C/min, or user-defined (0.5–12 °C/min) |
| Temperature Accuracy | ±0.1 °C |
| Pressure Measurement Range | 0–200 kPa |
| Sample Volume | 1 mL or 2 mL |
| Stirring Speed | 50–300 rpm |
| Standards Compliance | ASTM D6450, ASTM D7094, ASTM D93, ASTM D3828, GB/T 261, GB/T 21615, GB/T 5208, GB/T 21790, SH/T 0768, SN/T 3077.1 & 3077.2, DL/T 1354 |
| Interface | RS232 ×1, RJ45 ×1, USB ×2 |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 300 W |
| Dimensions | 225 mm × 310 mm × 415 mm |
| Weight | 13.5 kg |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | FP CC-420A |
| Detection Method | Closed-Cup Method |
| Temperature Range | −30 °C to 420 °C |
| Ignition Method | High-Voltage Electric Arc |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HFM 510A |
| Measurement Principle | Heat Flow Method |
| Thermal Conductivity Range | 0.002–1 W/(m·K), extendable to 1–2 W/(m·K) |
| Plate Temperature Range | −30–90 °C |
| Thickness Measurement Range | 0–100 mm |
| Thickness Resolution | 0.02 mm |
| Contact Pressure | Adjustable up to 21 kPa (1930 N) |
| Thermal Resistance Range | 0.1–8 m²·K/W |
| Accuracy | ±(1–2)% |
| Repeatability | ≤0.5% |
| Sample Dimensions | 300 mm × 300 mm × ≤100 mm |
| Environmental Operating Range | −5–45 °C, <95% RH |
| Cooling System | External Oil Bath with Peltier Heating/Cooling Control |
| Data Acquisition Points | >10 per test cycle |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HWP01-10S |
| Price | Upon Request |
| Operating Environment | 5–30 °C, <85% RH |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±1 °C |
| Uniformity in Test Zone | ±1.5 °C (≤140 °C), ±2 °C (140–180 °C), ±2.5 °C (180–200 °C) |
| Temperature Measurement Range | 0–500 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±2.5 °C (<300 °C), ±0.75% of reading (≥300 °C) |
| Standard Timer Range | 0–24 h |
| Custom Timer Range | 0–48 h |
| Timer Resolution | 1 s |
| Wire Mesh Containers | Small cube: 25 mm side, 0.05 mm aperture |
| Small cover | 30 × 30 × 30 mm |
| Large cube | 100 mm side, 0.05 mm aperture |
| Large cover | 105 × 105 × 105 mm |
| Cage dimensions | 150 × 150 × 250 mm |
| Chamber Interior Dimensions | 350 × 350 × 400 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP01-20S |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±1 °C |
| Uniformity in Test Zone | ±1.0 °C (≤140 °C), ±1.5 °C (140–180 °C), ±2.0 °C (180–200 °C) |
| Thermocouple Range | −40 to 1000 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Measurement Accuracy | ±1.5 °C or ≤±0.004 |
| Response Time | 0.5 s |
| Standard Timer Range | 0–240 h |
| Custom Timer Range | 0–480 h |
| Timer Accuracy | ±0.01 s |
| Timer Display Resolution | 1 s |
| Chamber Volume | ≥27 L |
| Self-Heating Test Mesh Cage Sizes | 25 mm × 25 mm × 25 mm and 100 mm × 100 mm × 100 mm |
| 75 °C Stability Vessel Dimensions | Φ(50.5 ± 0.5) mm × 150 mm |
| Interior Chamber Dimensions | 350 mm × 350 mm × 400 mm |
| Safety Valve Activation Pressure | 60 kPa |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HWP01-20S |
| Pricing | Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP02-20S |
| Quotation | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Ignition Source Temperature | ≥1000 °C |
| Ignition Methods | Gas igniter and silicon nitride rod |
| Combustion Detection Method | Near-infrared (NIR) spectroscopy |
| Combustion Travel Range | 0–250 mm |
| Burning Distance Measurement Accuracy | ±0.5 mm |
| Maximum Combustion Velocity Detection | 250 mm/s |
| Timing Range | 5 min (non-metallic samples) |
| Time Display Resolution | 0.1 s |
| Stacking Mold Dimensions | 260 mm (L) × 20 mm (W), triangular cross-section with internal height of 10 mm |
| Combustion Plate Material | Alumina-mullite ceramic — non-porous, non-combustible, low thermal conductivity |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HWP04-10S |
| Pricing | Upon Request |
| Operating Environment | (-5–45)°C, <95% RH |
| Channel Capacity | Standard 2 channels, customizable up to 8 |
| Temperature Control Range | Ambient to 98°C |
| Temperature Control Accuracy | ≤±0.5°C |
| Temperature Fluctuation | ≤±0.3°C |
| Temperature Uniformity | ±0.5°C |
| Heating Tube Material | SUS316 stainless steel |
| Bath Tank Material | Stainless steel |
| Timing Range | 0–35 days |
| Timing Accuracy | ±0.01 s |
| Time Display Resolution | 1 minute |
| Sample Vessel Volume | 3000 mL (effective volume: 2000 mL) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Model | HWP05-20S |
| Operating Temperature | (-5–45) °C, <95% RH |
| Optical Detection Range | 760–1100 nm (IR), Sampling Frequency: 5000 Hz |
| Mass Measurement Range | 0–3100 g, Resolution: ≤±0.01 g |
| Mass Data Acquisition Rate | ≤5 Hz |
| Heating Element | Inert metal wire (standard geometry), Power: 150 W ±2 W |
| Detection Modes | IR sensor array or analytical balance |
| Balance Accuracy | ±0.1 g |
| Ambient Temp. Range | -10–+60 °C, Accuracy: ±0.5 °C |
| Ambient Humidity Range | 5–95% RH, Accuracy: ±5.0% RH |
| Timer Range | 0–24 h, Resolution: ±0.01 s, Accuracy: ±7 ms/min |
| Test Plate | Alumina ceramic, 150 mm × 150 mm × 6 mm |
| Sample Mold | PTFE, conical (70 mm ID, 60° apex angle) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HWP06-20S |
| Price | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Pressure Vessel Dimensions | Ø60 mm × 89 mm (cylindrical stainless steel, side-mounted pressure sensor) |
| Pressure Sensor Response Time | ≤5 ms (0–3 MPa step change) |
| Pressure Measurement Range | 0–5 MPa |
| Pressure Accuracy | ±0.1% FS |
| Ignition Method | Electronic spark ignition |
| Burst Disc Rated Pressure | 2.5 MPa ±5% |
| Timing Range | 0–60 s |
| Timing Accuracy | ±0.001 ms |
| Timing Resolution | 0.01 ms |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HWP08-10S |
| Pricing | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Standard Test Temperatures | 60.5 °C / 75 °C |
| Temperature Control Range | Customizable |
| Temperature Control Accuracy | ±0.5 °C |
| Ambient Atmospheric Pressure Measurement Range | (0–110) kPa |
| Ambient Atmospheric Pressure Measurement Accuracy | ±0.25 kPa |
| Ignition Timing Options | 30 s / 60 s |
| Sample Volume | (1–3) mL |
| Sample Delivery Accuracy | ±0.05 mL |
| Timing Range | (0–999) s |
| Timing Resolution | 0.1 s |
| Timing Accuracy | ±0.01 s |
| Ignition Method | Spark Plug |
| Sample Vial Capacity | 20 mL |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | Domestic (China) |
| Model | HWP09-10S |
| Quotation | Upon Request |
| Operating Environment | (-5–45) °C, <95% RH |
| Detection Method | Near-Infrared (NIR) |
| Spectral Response Range | 760–1100 nm |
| Spectral Response Frequency | 5000 Hz |
| Ambient Temperature Range | (-10–+60) °C |
| Ambient Temperature Accuracy | ±0.5 °C |
| Ambient Humidity Range | (5–95)% RH |
| Ambient Humidity Accuracy | ±5.0% RH |
| Combustion Detection Response Time | ≤6 ms |
| Ignition Distance Measurement Range | 15–90 cm |
| Burner Positioning Accuracy | ±1 mm |
| Timing Resolution | ±0.01 s |
| Minimum Actuation Duration | 5 s |
| Ignition Source | Gas-fired igniter |
| Aerosol Can Orientation | Motorized vertical/inverted repositioning |
| Compatible Can Dimensions | Height 120–400 mm, Diameter 30–80 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP10-10S |
| Pricing | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Ambient Temperature Range | -10 to +60 °C |
| Ambient Temperature Accuracy | ±0.5 °C |
| Ambient Humidity Range | 5–95% RH |
| Ambient Humidity Accuracy | ±5.0% RH |
| Flame Detection Response Time | ≤6 ms |
| Differential Pressure Range | -5 to +5 kPa |
| Pressure Measurement Accuracy | ±0.1% FS |
| Spectral Response Range | 760–1100 nm (Near-Infrared) |
| Spectral Response Frequency | 5000 Hz |
| Timing Accuracy | ±0.01 s |
| Timing Resolution | 0.1 s |
| Ignition Source | Standardized candle flame |
| Test Chamber Dimensions | Ø600 mm × 720 mm (200 dm³ volume) |
| Aerosol Can Orientation | Motorized dual-axis positioning (vertical/inverted) |
| Compatible Can Dimensions | Height 120–400 mm, Diameter 30–80 mm |
| Nozzle-to-Chamber Distance | Adjustable from 25 to 100 mm |
| Residual Liquid Collection Tray | Removable stainless-steel drip pan |