Zhuochi
Filter
Showing 1–30 of 115 results
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | General Distributor |
| Product Origin | Domestic |
| Model | SK3-2.5-10X |
| Instrument Type | Tube Furnace |
| Max Temperature | 1000 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 2.5 kW |
| Heating Rate (to Max Temp) | ≤50 °C/min |
| Heating Method | Resistance Wire Heating |
| Internal Chamber Dimensions | φ80 mm × 380 mm |
| Controller Size | 80 mm × 610 mm |
| Brand | ZHUOCHI |
|---|---|
| Origin | Zhejiang, China |
| Model | SK3-2.5-13 Complete System |
| Type | Laboratory Benchtop Tube Furnace |
| Temperature Range | 100–1300 °C |
| Temperature Stability | ±1 °C |
| Display Resolution | 1 °C |
| Furnace Chamber Dimensions | φ22 mm × 380 mm |
| Heating Zone Length | 280 mm |
| Max Ramp Rate | ≤50 °C/min (adjustable) |
| Power Rating | 2.5 kW |
| Supply | 220 V, 50 Hz |
| Weight | ~22 kg |
| Control System | LTDE Programmable PID Controller with SSR Output, Dual-Stage Over-Temperature Protection |
| Thermal Insulation | High-Efficiency Ceramic Fiber Blanket |
| Heating Element | Oxidation-Resistant High-Temperature Resistance Wire |
| Thermocouple Type | S-Type (Platinum-Rhodium/Platinum) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | SK3-2.5-13 |
| Type | Laboratory Benchtop Tube Furnace System |
| Temperature Range | 100–1300 °C |
| Temperature Uniformity | ±1 °C |
| Heating Zone Length | 280 mm |
| Tube ID Compatibility | φ22 mm |
| Max Ramp Rate | 50 °C/min (adjustable) |
| Power Rating | 2.5 kW |
| Supply | 220 V, 50 Hz |
| Weight | ~22 kg |
| Compliance | Designed for LYT 1255–1999 (Forestry Industry Standard of the People’s Republic of China: Determination of Total Sulfur in Soils by High-Temperature Combustion–Infrared Absorption Method) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Type | Laboratory Benchtop Combustion-Based Total Sulfur Analyzer |
| Model | LYT 1255-1999 compliant SK3-2.5-13 |
| Temperature Range | 100–1300 °C |
| Temperature Stability | ±1 °C |
| Furnace Tube ID | φ22 mm |
| Heating Zone Length | 280 mm |
| Max Ramp Rate | ≤50 °C/min (adjustable) |
| Power | 2.5 kW |
| Voltage/Frequency | 220 V, 50 Hz |
| Weight | ~22 kg |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | ZC-1N |
| Instrument Type | High-Temperature Forced-Air Drying Oven |
| Temperature Range | Ambient +5°C to 180°C |
| Temperature Uniformity | ±3% |
| Temperature Fluctuation | ±2°C |
| Display Resolution | 1°C |
| Heating Power | 6 kW |
| Circulation Fan Power | 550 W |
| Chamber Dimensions (W×D×H) | 500 × 1300 × 650 mm |
| External Dimensions (W×D×H) | 700 × 1800 × 800 mm |
| Insulation | High-Density Glass Fiber |
| Inner Chamber Material | Stainless Steel (SUS304) |
| Heating Element | Stainless Steel Sheathed Tubular Heaters |
| Air Circulation | Top-Mounted Heavy-Duty Axial Fan with Dual-Side Return Air Ducts |
| Control System | LTDE Programmable PID Controller (30-Stage Ramp/Soak) |
| Safety Features | Dual Independent Over-Temperature Protection, Leakage Current Protection, Motor Overcurrent Protection, High-Temperature Silicone Door Seal |
| Power Supply | 380 V AC, 50 Hz |
| Net Weight | ~280 kg |
| Standard Packaging | Wooden Crate |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | ZC1200KX |
| Max Temperature | 1200 °C |
| Temperature Uniformity | ±1 °C |
| Max Power | 2.5 kW |
| Heating Rate | ≤30 °C/min |
| Heating Method | Resistance Wire (0Cr27Al7Mo2) |
| Internal Chamber Dimensions | 60 mm (ID) × 400 mm (L) |
| Effective Heating Zone Length | 400 mm |
| Tube Configuration | Straight quartz tube (60 mm OD), optional tapered quartz tube (60 mm → 100 mm → 60 mm) |
| Sealing | Stainless steel flanges with float-type mass flow meters |
| Tilt Angle | 0–15° adjustable |
| Rotation Capability | Motor-driven continuous or intermittent tube rotation |
| Vacuum Rating | –0.1 MPa |
| Temperature Sensor | S-type platinum-rhodium thermocouple |
| Control System | LTDE 50-segment programmable PID controller |
| Compliance | Designed for GLP-compliant thermal processing environments |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | 151B-3X |
| Temperature Range | 50–600 °C |
| Temperature Uniformity | ≤ ±1.5% |
| Temperature Stability | ±1% of setpoint |
| Rated Power | 7500 W |
| Voltage | 380 V, 50 Hz |
| Interior Dimensions (W×D×H) | 500 × 600 × 750 mm |
| Shelf Capacity | ≥15 kg per shelf (2 adjustable shelves) |
| Control System | LTDE modular programmable PID controller with 30-segment ramp-soak programming |
| Heating Method | Stainless steel heating elements with distributed forced-air circulation (imported point-distribution technology) |
| Insulation | Ceramic fiber (aluminosilicate wool) |
| Safety Features | Dual-stage overtemperature protection, thermal cutoff relay, fuse, earth leakage circuit breaker, door interlock switch, visual alarm indicator |
| Temperature Sensor | Type K thermocouple |
| Timer Range | 0–9999 minutes |
| Exhaust Port | Rear and top mounted |
| Optional | RS-232/RS-485 interface, data logging software, printer output |
| Brand | Zhuochi |
|---|---|
| Model | 151B-X |
| Temperature Range | 50–600 °C |
| Temperature Uniformity | ≤ ±1.5% |
| Temperature Stability | ±1% of setpoint |
| Control System | LTDE modular programmable PID controller with 30-segment ramp-soak programming |
| Heating Method | Forced-air convection via distributed high-temperature impeller system |
| Chamber Construction | Stainless steel interior, cold-rolled steel exterior with high-temp anti-rust coating and ceramic-fiber insulation (aluminosilicate wool) |
| Power Rating | 12 kW |
| Voltage/Frequency | 380 V, 50 Hz |
| Internal Dimensions | 800 × 800 × 1000 mm (W × D × H) |
| Shelf Capacity | 2 adjustable shelves, ≥25 kg per shelf |
| Safety Features | Dual-stage overtemperature protection, thermal cutoff fuse, earth leakage circuit breaker, door interlock switch, audible/visual alarm system |
| Compliance | Designed to meet general laboratory safety requirements for Class II electrical equipment |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | 30165-10 |
| Type | Horizontal Split-Type Tube Furnace |
| Max Temperature | 1000 °C |
| Furnace Chamber | Ø50 mm × 300 mm |
| Heating Power | 2.5 kW / 220 V |
| Effective Heating Zone | 200 mm |
| Temperature Accuracy | ±1 °C |
| Tube Length Compatibility | ≥400 mm |
| Control System | 30-Stage Programmable PID Controller |
| Safety Features | Dual Over-Temperature Protection, Earth Leakage & Electric Shock Protection |
| Optional | PC-Based Data Logging Software (RS485/USB Interface) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Type | Horizontal Split-Type Tube Furnace |
| Max Temperature | 1000 °C |
| Temperature Uniformity (Steady-State) | ±1 °C |
| Display Resolution | 1 °C |
| Heating Rate (to Max Temp) | ≤50 °C/min |
| Rated Power | 2.5 kW |
| Internal Chamber Dimensions | Ø50 × 300 mm |
| Heating Zone Length | 200 mm |
| Compatible Tube Size | Ø50 × 400–910 mm |
| Heating Element | High-Temperature Resistance Wire |
| Insulation | Lightweight Ceramic Fiber Composite (Dual Semi-Cylindrical Modules) |
| Cooling Method | Air Cooled |
| Thermocouple Type | K-Type (NiCr–NiSi) |
| Controller | LTDE Programmable PID Controller with Ramp/Soak Profiles |
| Safety | Dual-Stage Over-Temperature Protection |
| Power Supply | 220 V, 50 Hz |
| Net Weight | ~20 kg |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | 30165-10A (Vertical) |
| Instrument Type | Tube Furnace |
| Max Temperature | 1000 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 2.5 kW |
| Heating Rate (to Max Temp) | ≤50 °C/min |
| Heating Method | Resistance Wire Heating |
| Internal Chamber Dimensions | φ50 × 300 mm |
| Furnace Weight | ~10 kg |
| Power Supply | 220 V, 50 Hz |
| Temperature Sensor | K-type Thermocouple |
| Controller | LTDE Programmable PID Controller |
| Insulation | High-Efficiency Ceramic Fiber (Dual Semi-Cylindrical Modules) |
| Cooling Method | Air Cooling |
| Safety | Dual-Stage Over-Temperature Protection |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | 30165-10A |
| Maximum Temperature | 1000 °C |
| Furnace Tube Dimensions | Ø50 mm × 300 mm |
| Heating Zone Length | 200 mm |
| Power Rating | 2.5 kW / 220 V |
| Temperature Accuracy | ±1 °C |
| Control System | 30-Stage Programmable PID Controller |
| Safety Features | Dual Over-Temperature Protection + Earth Leakage & Electric Shock Protection |
| Compliance | Designed for GLP-compliant thermal processing in research and QC labs |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | 3DHG |
| Temperature Range | RT +10°C to 250°C |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Resolution | 0.1°C (display), ±0.5°C (control accuracy) |
| Chamber Dimensions (W×D×H) | 300 × 300 × 270 mm |
| External Dimensions (W×D×H) | 510 × 500 × 440 mm |
| Inner Chamber Material | Mirror-finish 304 stainless steel |
| Heating Element | Stainless steel sheathed heater |
| Air Circulation | Adjustable rear inlet + top/bottom outlet, horizontal forced convection via long-shaft fan with aluminum alloy impeller |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power | 500 W |
| Net Weight | 29 kg |
| Compliance | Designed per IEC 61010-1 safety standards for laboratory equipment |
| Brand | Zhuochi |
|---|---|
| Model | 60250-12-6 |
| Temperature Range | 100–1200 °C |
| Max. Temp | 1200 °C |
| Control Accuracy | ±1 °C |
| Display Resolution | 1 °C |
| Max. Power | 3 kW |
| Heating Rate (to max temp) | ≤50 °C/min |
| Heating Element | High-Temperature Resistance Wire |
| Chamber Dimensions | Ø60 × 600 mm |
| Effective Heating Zone | 500 mm |
| Compatible Tube Size | Ø60 × 610–1110 mm |
| Insulation | Dual-Half-Circle Ceramic Fiber Modular Liner |
| Cooling Method | Air Cooling |
| Thermocouple Type | S-Type Platinum-Rhodium/Platinum |
| Controller | LTDE Programmable PID Controller with Ramp/Soak Profiles |
| Safety Features | Dual-Stage Over-Temperature Protection |
| Power Supply | 220 V, 50 Hz |
| Net Weight | ~25 kg |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | 658-2013 |
| Instrument Type | Tube Furnace |
| Max Temperature | 1100 °C |
| Temperature Stability | ±1 °C |
| Display Resolution | 1 °C |
| Heating Power | 2.5 kW |
| Voltage/Frequency | 220 V / 50 Hz |
| Tube Dimensions | Ø20 mm × 600 mm |
| Internal Chamber Diameter | 20 mm |
| Nominal Volume | 20 mL |
| Heating Method | Resistance Wire |
| Control Mode | PID |
| Ramp Rate to Max Temp | 30 min |
| Rated Power | 2500 W |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-1000 |
| Measurement Principle | Combustion-Coulometric Titration |
| Measurement Range | 5–1000 µg/L (as Cl⁻) |
| Accuracy | ±1% |
| Repeatability (RSD) | ≤1% |
| Detection Limit | 0.8–1000 µg/L |
| Resolution | 0.01 µg |
| Compliance | Designed to meet ISO 9562 and EPA Method 1650 requirements for AOX determination |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AOX-3 |
| Price | USD 4,200 (FOB Zhejiang) |
| Measurement Principle | Combustion–Microcoulometric Titration |
| Measurement Range | 0.8–1000 µg/L as Cl⁻ |
| Accuracy | ±<5% (vs. certified reference materials) |
| Repeatability (RSD) | <5% at ≥10 µg/L |
| Limit of Detection (LOD) | 0.8 µg/L as Cl⁻ |
| Resolution | 0.1 µg/L (digital display) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Measurement Principle | Combustion–Coulometric Titration |
| Measurement Range | 0.8–1000 µg/L |
| Accuracy | <5% |
| Repeatability | <5% |
| Limit of Detection (LOD) | 0.8 µg/L |
| Resolution | 0.8 µg/L |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion–Microcoulometric Titration |
| Measurement Range | 0.8–1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8 µg/L |
| Resolution | 0.01 µg |
| Combustion Temperature | Up to 1150 °C |
| Furnace Temperature Stability | ±1 °C |
| Heating Rate | Adjustable up to 50 °C/min |
| Furnace Chamber Dimensions | Ø40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion Coupled with Coulometric Titration |
| Measurement Range | 5–1000 mg sample mass |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8–1000 µg/L |
| Resolution | 0.01 µg |
| Max Operating Temperature | 1150 °C |
| Temperature Stability | ±1 °C |
| Heating Rate | Up to 50 °C/min (adjustable) |
| Furnace Chamber | φ40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion Coupled with Coulometric Titration or Ion Chromatography |
| Detection Range | 0.8 µg/L – 1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| LOD | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Operating Temperature | 1150 °C |
| Temperature Stability | ±1 °C |
| Furnace Chamber Dimensions | Ø40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Measurement Principle | High-Temperature Combustion Coupled with Coulometric Titration |
| Measurement Range | 5–1000 mg sample mass |
| Detection Range | 0.8 µg/L – 1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Operating Temperature | 1150 °C |
| Temperature Stability | ±1 °C |
| Heating Rate | Up to 50 °C/min (adjustable) |
| Furnace Chamber | φ40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion Coupled with Microcoulometric Titration |
| Detection Range | 0.8–1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| LOD | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Combustion Temperature | 1150 °C |
| Furnace Temp Control Stability | ±1 °C |
| Heating Rate | Adjustable up to 50 °C/min |
| Furnace Chamber | φ40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Dimensions (W×D×H) | 345 × 360 × 660 mm |
| Brand | Zhuochi |
|---|---|
| Model | AOX-3 Standard |
| Origin | Zhejiang, China |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Principle | High-Temperature Catalytic Combustion Coupled with Ion Chromatography or Microcoulometric Detection |
| Measurement Range | 0.8 µg/L to 1000 µg/L |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | Nitrogen-pressurized Column Adsorption (Activated Carbon Cartridge) |
| Sample Mass | 5–1000 mg |
| Analysis Time (Combustion & Detection Cycle) | 3–10 min (excluding sample pre-concentration) |
| Carrier Gas | Oxygen ≥99.6% (99.999% recommended) |
| Sample Boat | Modified Quartz Boat for Direct Injection |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AOX-3 |
| Price | USD 3,950 (FOB) |
| Detection Principle | High-Temperature Combustion Coupled with Microcoulometric Titration or Ion Chromatography |
| Detection Range | 0.8–1000 µg/L (as Cl⁻ equivalent) |
| Accuracy | ±1% |
| Repeatability (RSD) | ≤1% |
| Detection Limit | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Combustion Temperature | 1150 °C |
| Temperature Control Stability | ±1 °C |
| Heating Rate | Adjustable up to 50 °C/min |
| Furnace Chamber Dimensions | Ø40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 Standard |
| Measurement Principle | High-Temperature Combustion Coupled with Coulometric Titration |
| Detection Range | 0.8 μg/L to 1000 μg/L |
| Accuracy | <1% |
| Repeatability | <10% |
| Limit of Detection (LOD) | 0.1 μg |
| Resolution | 0.01 μg |
| Max Combustion Temperature | 1150 °C |
| Sample Introduction | Pressurized Nitrogen-Driven Column Adsorption (5–1000 mg) |
| Analysis Time (Combustion & Detection) | 3–10 min (excluding pre-concentration) |
| Required Gases | O₂ ≥99.6% (99.999% recommended), N₂ for adsorption |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AOX-3-ZC |
| Price | USD 4,200 (approx.) |
| Measurement Principle | Combustion-Coulometric Titration |
| Measurement Range | 5–1000 µg AOX per sample |
| Accuracy | ±1% (relative to certified reference material) |
| Repeatability (RSD) | ≤1% |
| Detection Limit | 0.8–1000 µg/L (sample-dependent, based on 100 mL preconcentration volume) |
| Resolution | 0.01 µg (coulometric current integration) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AOX-3J |
| Instrument Type | Tube Furnace |
| Max Temperature | 1150 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 1500 W |
| Heating Rate to Max Temp | 30 min |
| Heating Method | Resistance Wire |
| Internal Chamber Diameter | 20 mm |
| Control System | PID |
| Nominal Volume | 2 L |
| Tube ID | 20 mm |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AOX-S |
| Pricing | Upon Request |
| Measurement Principle | Combustion–Microcoulometric Titration |
| Furnace Temperature Range | 500–1000 °C |
| Temperature Accuracy | ±1% ±5 °C |
| Measurement Accuracy | <5% |
| Repeatability | <5% |
| Limit of Detection (LOD) | 0.1 µg/L (as Cl⁻ equivalent) |
| Resolution | Not specified |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-S Zhuochi |
| Measurement Principle | Combustion-Microcoulometric Titration |
| Temperature Range | 500–1000 °C (±1 % ±5 °C) |
| Accuracy | <5 % |
| Repeatability | <5 % |
| Limit of Detection | 0.1 µg/L |
| Compliance | HJ 1214–2021 (China EPA Standard for Water Quality — Determination of Adsorbable Organic Halogens by Microcoulometry) |