| Brand | Zeiss |
|---|---|
| Origin | Germany |
| Model | Smartzoom 5 |
| Type | Automated Digital Stereo Microscope with Integrated Imaging Engine |
| Optical Configuration | Reflected and Transmitted Light Capable |
| Zoom Range | 10×–2022× Continuous Magnification (including digital zoom) |
| Core Optics | Motorized Zoom Objective with Coaxial Illumination & Panoramic Imaging Capability |
| Compliance | Designed for ISO/IEC 17025, ASTM E2904, and GLP/GMP-aligned workflows |
| Brand | Zeiss |
|---|---|
| Origin | Germany |
| Model | Axiovert 5 Digital |
| Configuration | Integrated digital imaging system with built-in camera and touchscreen interface |
| Optical System | IC2S-corrected optics (achromatic and contrast-optimized) |
| Objective Turret | Encoded 6-position |
| Filter Turret | Encoded 6-position |
| Illumination | Encoded transmitted-light and fluorescence illumination with intensity management |
| Imaging Mode | OSD (On-Screen Display) — direct monitor output without PC |
| AI Module | LabScope AI for automated confluence analysis and cell counting |
| Sample Clearance | Up to 220 mm height |
| Eco Mode | Power-saving operational profile |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Zeiss |
|---|---|
| Origin | Germany |
| Model | Lattice SIM 3 |
| Type | Structured Illumination Microscopy (SIM) System |
| Optical Principle | Lattice Light-Sheet Illumination Combined with High-Frequency Patterned SIM |
| Max. Resolution (XY) | ~120 nm |
| Max. Resolution (Z) | ~300 nm |
| Imaging Speed | Up to 500 frames/sec (full-frame, region-of-interest dependent) |
| Penetration Depth | Up to 100–200 µm in cleared tissue |
| Objective Compatibility | 25×/1.0 NA water-dipping, 40×/1.1 NA water-immersion, 63×/1.2 NA water-immersion |
| Laser Lines | 405, 488, 561, 640 nm (standard) |
| Detection Channels | 4-channel simultaneous spectral detection with GaAsP PMTs or sCMOS cameras |
| Software Platform | ZEN Imaging (with Lattice SIM module), supports 3D deconvolution, drift correction, and multi-color registration |
| Compliance | CE-marked, compliant with ISO 13485 (for IVD-relevant configurations), supports FDA 21 CFR Part 11 audit trail (in validated ZEN Blue environment) |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Lattice SIM 5 |
| Resolution | ≤60 nm (lateral, live-cell compatible) |
| Imaging Modality | 3D super-resolution structured illumination microscopy (3D-SIM) |
| Objective Compatibility | Oil-immersion objectives up to 1.4 NA (e.g., Plan-Apochromat 63×/1.4 Oil) |
| Live-cell Capability | Yes, with low phototoxicity and high temporal resolution |
| Fluorescence Channels | Up to 4-color simultaneous acquisition |
| Software Platform | ZEN Imaging Software (Blue Edition), supports GLP-compliant metadata logging and audit trail (21 CFR Part 11 ready) |
| Brand | Zeiss |
|---|---|
| Origin | Germany |
| Model | LSM 880 with Airyscan |
| Detection Principle | Laser Scanning Confocal Microscopy with Airyscan Detector Array |
| Lateral Resolution | ≤120 nm (xy) |
| Axial Resolution | ≤350 nm (z) |
| Maximum Imaging Speed | 27 fps (480 × 480 pixels) |
| Signal-to-Noise Ratio Enhancement | 4–8× vs. conventional PMT-based confocal |
| Optical Sectioning | True confocal + Airyscan super-resolution mode |
| Compatible Excitation | Single-photon & multiphoton (with optional MP module) |
| Software Platform | ZEN Blue/Black |
| Compliance | Fully compatible with GLP/GMP workflows, FDA 21 CFR Part 11 audit trail support (via ZEN Black), ISO 9001-certified manufacturing |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Primostar 3 |
| Illumination Options | Halogen and LED |
| Objective Turret | 4-position or 5-position |
| Field Number | 20 mm / 22 mm |
| Eyepiece Diopter Adjustment | Yes (both eyepieces) |
| Rotatable Binocular Tube | 360° |
| Stage | Ergonomic mechanical stage with dual slide clips |
| Illumination Control | Brightness management + energy-saving mode |
| Observation Modes | Brightfield, Darkfield, Simple Polarization, Phase Contrast, Fluorescence |
| Digital Integration | Compatible with ZEISS Labscope software and HDcam module |
| Compliance | Designed for ISO 13485-aligned laboratory environments and GLP-compliant teaching labs |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Apotome 3 |
| Type | Structured illumination-based optical sectioning module |
| Compatibility | Integrates with ZEISS Axio inverted and upright widefield fluorescence microscopes (e.g., Axio Observer, Axio Imager), as well as macro zoom systems |
| Optical Principle | Grid-projected structured illumination with computational reconstruction |
| Axial Resolution Enhancement | ~1.5–2× improvement over conventional widefield fluorescence |
| Software Integration | Fully embedded in ZEN imaging platform (ZEN Blue/Black) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Licensing | Requires active ZEN software license (v3.4 or later) |
| Brand | SUSS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DeepVision |
| Pricing | Upon Request |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Metafer |
| Pricing | Available Upon Request |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | LSM 910 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Optical Resolution (XY) | ≤ 80 nm (measured via FWHM of fluorescent beads) |
| Volumetric Imaging Speed | Up to 80 volumes/s |
| System Architecture | Integrated Airyscan Detection |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–enabled software configurations |
| Software Platform | ZEN Intellesis & ZEN Blue with LightField 4D module |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Stemi 355 |
| Total Magnification Range | 7.2×–40× (up to 200× with optional eyepieces and auxiliary lenses) |
| Zoom Ratio | 5.5:1 |
| Field of View Diameter | up to 64 mm |
| Working Distance | up to 185 mm |
| Objective Type | Greenough-type stereoscopic optical system |
| Illumination | Integrated LED illumination with selectable modes — near-vertical incident light, dual-side reflected light, ring light, transmitted light, and mixed illumination |
| Depth of Field | Optimized for high-resolution stereo imaging across zoom range |
| Numerical Aperture (NA) | 0.082 |
| Resolution | 489 lp/mm (at maximum magnification and optimal focus) |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Instrument Type | Point-Scanning Confocal Microscope |
| Model | LSM 990 |
| Detector Technology | GaAsP Hybrid Detectors (HyD) & Airyscan 2 |
| Maximum Lateral Resolution | ≤80 nm (measured via FWHM of fluorescent beads) |
| Volumetric Imaging Speed | Up to 80 volumes/s |
| Excitation Sources | Integrated Multi-Line Lasers (405, 488, 561, 633 nm standard |
| Software Platform | ZEN Intellesis + ZEN Blue |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Lightsheet 7 |
| Type | Light-Sheet Fluorescence Microscope (LSFM) |
| Optical Architecture | Dual-Objective Illumination & Detection |
| Sample Compatibility | Cleared Tissues, Live Organisms, 3D Cultures, Plant Specimens |
| Maximum Imaging Volume | ≥16 mm × 6.6 mm × 16 mm |
| Spatial Resolution | ≤220 nm (lateral), ≤570 nm (axial) |
| Refractive Index Matching Range | 1.38–1.56 |
| Native Pixel Size (configurable) | Down to 222 × 222 × 567 nm |
| Acquisition Speed | Up to 200+ volumes per second (depending on ROI and binning) |
| Detector | sCMOS with >95% quantum efficiency |
| Software Platform | ZEN Connect with Multiview Reconstruction, Deconvolution, and Time-Lapse Registration |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Elyra 7 |
| Category | Imported Instrument |
| Distribution Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | LSM 9 Series with Airyscan 2 |
| Detection Principle | Scanning Laser Confocal Microscopy with Pixel-Reassignment Super-Resolution |
| Resolution (XY) | Up to 90 nm |
| SNR Improvement | 4–8× vs. conventional confocal |
| Imaging Modes | Standard Confocal, Airyscan 2 Multiplex, Airyscan 2 Fast, Lambda Spectral Acquisition, Dynamics Profiler |
| Software Platform | ZEN Blue/Black (GLP-compliant workflow support, audit trail, user access control) |
| Compliance | ISO 13485–certified manufacturing, FDA 21 CFR Part 11–ready configuration available |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Axioscan 7 |
| Imaging Modes | Brightfield, Fluorescence (up to 9 channels), Polarization |
| Objective Compatibility | Plan-Apochromat objectives (e.g., 20×/0.8 NA) |
| Automation | Fully automated slide loading, focus calibration, geometric & chromatic correction, multi-layer scanning |
| Compliance | Designed for GLP/GMP-adjacent workflows |
| Software Platform | ZEN Connect with integrated image management, annotation, and export to DICOM, OME-TIFF, and SVS formats |
| Brand | ZEISS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RIMA Spatial Biology Solution |
| Pricing | Upon Request |
| Brand | Zeiss |
|---|---|
| Origin | Germany |
| Model | Axio Imager 2 Vario |
| Sample Stage Travel (X-Y) | 300 × 300 mm |
| Vertical Working Distance | 254 mm |
| Auto-Focus Range | up to 12,000 µm |
| Cleanroom Compliance | ISO 5 (DIN EN ISO 14644-1) |
| Optical Configuration | Reflected & Transmitted Brightfield, 10× Objective Included |
| Application Focus | Wafer Inspection, TFT Array Metrology, Photovoltaic Quality Control, Cultural Heritage Analysis |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | arivis Pro |
| Compatibility | Native support for >60 image formats including CZI, TIFF, LSM, ND2, OME-TIFF, STK, etc. |
| Deployment | Local workstation (Windows 10/11 64-bit), GPU-accelerated processing (NVIDIA CUDA-compatible GPUs recommended) |
| Data Scale Handling | Optimized for terabyte-scale 2D–5D volumetric datasets (up to 100+ TB via virtual tiling) |
| AI Framework Integration | Built-in inference and training pipelines for Cellpose, Semantic Segmentation, Instance Segmentation, and custom PyTorch/TensorFlow models |
| Compliance | Supports audit trails, user role management, and export logs compliant with GLP/GMP documentation requirements |
| Brand | Zeiss |
|---|---|
| Origin | Germany |
| Model | Axio Observer |
| Optical Path | V-shaped (shortest optical path) |
| Z-axis Resolution | 10 nm |
| Optical System | IC2S Chromatic & Contrast Correction |
| Fluorescence Pathway | Apochromatic with Fluorescence Trap Technology |
| AI Function | Automated Sample Recognition System |
| Sample Access Space | Large open stage for incubation-compatible setups |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13694 (laser-based measurement traceability), ASTM E2857 (microscopy validation guidelines) |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Lattice Lightsheet 7 |
| Import Status | Imported Instrument |
| Distribution Type | Authorized Distributor |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SteREO Discovery |
| Pricing | Upon Request |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Axio Imager MAT&POL |
| Objective Turret | 6- or 7-position encoded turret (HD/POL/DIC, manual/electric/ACR) |
| Reflected Light Turret | 6- or 10-position encoded turret (manual/electric/ACR) |
| Objectives | 5×, 10×, 20×, 50×, 100× (optional: 1.25×, 2.5×, 150× |
| Eyepieces | 10× widefield (FOV 23 mm |
| optional | 16×, 25× |
| Illumination | 12 V / 100 W halogen lamp with intelligent light path manager, auto-adjustable intensity and color temperature |
| Stage Travel | 75 × 50 mm to 225 × 85 mm (X–Y) |
| sample height clearance | 0–63 mm (adjustable) |
| Stage Type | Manual or motorized (including automated scanning stage) |
| Contrast Modules (Reflected Light) | Brightfield (H), Darkfield (D/ADF), Polarized Light (Pol), Differential Interference Contrast (DIC), Circular DIC (C-DIC), Transmission Interference Contrast (TIC), Fluorescence (FI, multi-band) |
| Imaging System | Compatible with high-resolution scientific cameras and digital SLR systems |
| Software Modules | Grain size analysis, quantitative metallography, graphite rating (ASTM E1245, ISO 9276), comparative rating, thin-film thickness measurement, NMI (Non-Metallic Inclusion) analysis, particle sizing, 3D surface profiling |
| Optional Accessories | Motorized focus drive, transmitted light module, heating/cooling stages, spectrophotometric modules |
| Brand | Zeiss |
|---|---|
| Origin | Germany |
| Model | Axio Zoom.V16 |
| Zoom Ratio | 16:1 |
| Maximum Resolution | 1700 lp/mm |
| Z-Axis Positioning Accuracy | 350 nm |
| eZoom Technology | Yes |
| ApoTome.3 Compatibility | Yes |
| Objective Turret | Single- or Dual-Position |
| Fluorescence Brightness | Up to 10× Higher Than Conventional Stereo Microscopes |
| Illumination Modes | Reflected and Transmitted Light (Intelligent eZoom Control) |
| Compliance | Designed for ISO/IEC 17025, GLP, and GMP-Compliant Laboratories |