Common Laboratory Equipment
Filter
Showing 5701–5730 of 17696 results
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HN-5L |
| Price | USD 2,780 (FOB Shanghai) |
| Usable Volume | 5 L |
| Vessel Material | High-Borosilicate Glass (3.3) |
| Operating Pressure Range | Atmospheric to -0.098 MPa (gauge) |
| Jacket Inlet/Outlet | Standard 1/2" NPT |
| Temperature Range (Jacket) | -80 °C to +200 °C (with compatible heat transfer fluid) |
| Stirring Motor | AC Gear Motor, 180 W, 50–600 rpm, 300 N·cm max torque |
| Temperature Sensor | Pt100 RTD, ±0.3 °C accuracy |
| Sealing | Mechanical Seal with PTFE Stator/Rotor, DIN/ISO-compliant face seal design |
| Frame | Stainless Steel (304), Mobile Column-Type Support with Locking Casters |
| Lid Configuration | 5-Port Standard Ground-Glass Joint (NS29/32 & NS24/29) |
| Bottom Discharge | PTFE Plug Valve with ISO-KF Flange Interface |
| Vacuum Compatibility | Validated for continuous operation at ≤ –0.098 MPa (≤ 2 mbar abs) |
| Optional | ATEX-certified Explosion-Proof Motor (IECEx / CNEx certified) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HN-650CT |
| Ultrasonic Power | 650 W |
| Ultrasonic Frequency | 20 kHz |
| Heating Power | Standard |
| Temperature Range | −5 to 100 °C |
| Chamber Capacity | 600 mL |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-650CT |
| Ultrasonic Power Range | 100–3000 W |
| Ultrasonic Frequency | 20 kHz |
| Maximum Heating Power | 2 kW |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume Capacity | 100–5000 mL |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-6AL |
| Capacity | 6 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 180 W |
| Power Adjustment Range | 40–100% |
| Temperature Control Range | 10–80 °C |
| Timer Range | 0–30 min |
| Construction | Stainless Steel (SUS304) Tank and Housing |
| Heating Power | 200 W |
| Internal Tank Dimensions | 300 × 150 × 150 mm |
| External Dimensions | 330 × 180 × 280 mm |
| Net Weight | 5.8 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-6AL |
| Capacity | 6 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 120 W (adjustable 40–100%) |
| Heating Power | 100 W |
| Temperature Range | 20–80 °C |
| Timer Range | 0–30 min |
| Tank Material | SUS304 Stainless Steel |
| Lid | Sound-Dampening Cover |
| Drain | Manual Valve |
| Construction | Full SUS304 stainless steel tank, housing, and lid |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN-CSB10L |
| Price Range | USD 1,400–7,200 (FOB) |
| Ultrasonic Power | 5 kW |
| Ultrasonic Frequency | 28 kHz or 40 kHz (selectable) |
| Heating Power | Optional jacketed cooling/heating system (max. 1.5 kW electric heater, ±0.5 °C control accuracy) |
| Temperature Range | Ambient to 100 °C (with optional temperature-controlled jacket) |
| Vessel Capacity | 10 L (usable volume: 3–8 L for optimal cavitation efficiency) |
| Stirring Motor Power | 100 W |
| Stirring Speed | 0–1200 rpm (digital PID-controlled) |
| Probe Tip Diameter | 30 mm |
| Material | ASTM A240 Grade SUS304 stainless steel |
| Compliance | CE-marked per 2014/30/EU (EMC) and 2014/35/EU (LVD) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-G1A |
| Instrument Type | Constant-Temperature Bath |
| Circulation Mode | Internal Circulation |
| Temperature Control | Heating-Only |
| Bath Volume | 10 L |
| Temperature Range | Ambient to 300 °C |
| Temperature Stability | ±0.1 °C |
| Display Resolution | 0.1 °C |
| Tank Dimensions (Ø × D) | 300 × 200 mm |
| Depth | 200 mm |
| Opening Size | Ø170 mm |
| Construction | Triple-Sided Transparent Borosilicate Glass Walls with Stainless Steel Frame |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HN-LZ6 |
| Price | USD 4,200 (FOB Shanghai) |
| Drive Motor | Brushless DC Motor |
| Oscillation Modes | Vertical & Tilted |
| Tilt Angle Range | 0–22° adjustable |
| Frequency Range | 10–300 cycles/min (vertical), 20–250 cycles/min (tilted) |
| Stroke Amplitude | 45 mm |
| Max Load Capacity | 7 kg × 2 (including fixtures) |
| Flask Compatibility | Standard fixture — 50–1000 mL |
| Display | LED digital frequency & cycle counter |
| Operation Modes | Timed or continuous oscillation |
| Start/Stop Ramp | Soft acceleration/deceleration |
| Noise Level | ≤55 dB(A) |
| Power Supply | AC 220 V / 50 Hz |
| Compliance | CE-marked per EN 61000-6-3 (EMC), EN 61000-6-2 (Immunity), EN 61010-1 (Safety) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-LZ6 |
| Extraction Efficiency | 0–99% |
| Extraction Time Range | 0–999 min |
| Oscillation Modes | Vertical or Adjustable Tilt (0–22°) |
| Simultaneous Extraction Capacity | 6 separatory funnels |
| Oscillation Frequency Range | 10–300 rpm (vertical), 20–250 rpm (tilt) |
| Amplitude | 45 mm |
| Max Load per Side | ~7 kg (including fixtures) |
| Noise Level | ≤55 dB(A) |
| Drive System | Brushless DC Motor |
| Fixture Compatibility | 50–3000 mL (standard & large fixtures included) |
| Timer Function | Digital, memory-retentive, supports timed & continuous operation |
| Safety Features | Soft-start & soft-stop acceleration/deceleration profiles |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Range | HN-1L, HN-2L, HN-3L, HN-5L |
| Vessel Capacity | 1–5 L |
| Construction Material | GG17 borosilicate glass (ISO 3585 compliant) |
| Jacket Configuration | Double-wall vacuum-insulated |
| Operating Pressure | Ambient to –0.1 MPa (vacuum capable) |
| Stirring Motor | AC induction, brushless, variable-frequency drive |
| Speed Range | 50–800 rpm |
| Motor Power | 40 W (HN-1L), 90 W (HN-2L to HN-5L) |
| Max Torque | 2400 g·cm (HN-1L), 5000 g·cm (HN-2L–HN-5L) |
| Inner/Outer Diameter | 150×180 mm (1L/2L), 200×230 mm (3L/5L) |
| Lid Port Configuration | Central 50# standard taper, left 29#, right 24#, front 14# or 19#, rear optional (24# on HN-3L/HN-5L) |
| Bottom Discharge | PTFE-coated stainless steel valve with ISO-KF or DIN 2817 flange interface |
| Cooling/Heating Interface | Dual 1/2" NPT jacket inlets with thermal fluid compatibility up to 200 °C (heat transfer oil) and down to –80 °C (ethanol/dry ice or chiller) |
| Brand | Hanuo |
|---|---|
| Capacity | 10–50 L |
| Construction Material | Borosilicate Glass 3.3 (DIN ISO 3585) |
| Operating Pressure | Low-pressure, Vacuum-Compatible |
| Maximum Vacuum | −0.096 MPa (≈ 96 kPa absolute) |
| Stirring Speed Range | 50–600 rpm |
| Motor Type | Brushless AC Induction Motor |
| Power Input | 120–180 W (model-dependent) |
| Torque Output | 162–300 N·cm |
| Voltage | 220 V AC, 50 Hz |
| Jacket Inlet/Outlet | Standard G1/2″ or G3/4″ BSP |
| Lid Diameter | 265 mm |
| Port Configuration | 5 standard NS29/32 ground-glass joints |
| Bottom Discharge | PTFE-lined stainless steel valve with ISO-KF or DN25 flange interface |
| Cooling/Heating Medium Compatibility | Water, glycol/water mixtures, silicone oil, thermal oils (−80 °C to +200 °C) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN100 |
| Ice Production Capacity | 100 kg/24h |
| Storage Capacity | 15 kg |
| Ice Type | Flake Ice |
| Ice Making Method | Dual-Screw Extrusion |
| Power Input | 830 W |
| Voltage | 220 V AC |
| Dimensions (W×D×H) | 560 × 585 × 638 mm |
| Cooling Method | Air-Cooled |
| Water Consumption | Not Applicable (Self-Contained Closed-Loop System) |
| Equipment Type | Laboratory-Grade Flake Ice Generator |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN1L-5L |
| Price | USD 890 (FOB Shanghai) |
| Usable Volume | 1–5 L (Small-scale) |
| Construction Material | Borosilicate Glass 3.3 (DIN ISO 3585) |
| Operating Pressure | Low-pressure, up to 0.1 MPa (gauge) |
| Vacuum Capability | ≤ –0.098 MPa (i.e., ≤ 20 mbar abs) |
| Jacket Inlet/Outlet | Standard 1/2″ FTF ports |
| Stirring Motor | AC gearmotor (40–90 W, adjustable 50–800 rpm) |
| Max Torque | 2400–5000 g·cm |
| Temperature Sensor | Pt100 (IEC 60751 Class B, ±0.3 °C accuracy) |
| Sealing System | Dual-face mechanical seal with PTFE bellows and alloy steel housing |
| Frame | Mobile stainless steel (AISI 304) column stand with leveling feet |
| Lid Configuration | Five-neck standard ground-glass joints (NS 50/NS 29/NS 24/NS 24/NS 19 for HN-5L |
| Bottom Discharge | PTFE plug valve with flanged connection |
| Optional | ATEX-certified explosion-proof motor (IECEx/ATEX Zone 1) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN20M |
| Instrument Type | Precision Circulating Bath |
| Circulation Mode | Internal Circulation |
| Temperature Control | Refrigeration & Heating |
| Bath Volume | 6.5 L |
| Temperature Range | −20 °C to 95 °C |
| Temperature Stability | ±0.01 °C per 10 min |
| Temperature Uniformity | ≤0.01 °C |
| Settling Time | ≤10 min |
| Working Chamber Dimensions | Ø100 × 300 mm |
| Medium | Anhydrous Ethanol (for <30 °C), Deionized Water (for ≥30 °C) |
| Ambient Operating Temperature | <30 °C |
| Power Consumption | 750 W |
| Voltage/Frequency | 220 V / 50 Hz |
| External Dimensions (H × W × D) | 420 × 360 × 650 mm |
| Construction | Stainless Steel (Brushed Finish) Inner Tank and Outer Casing |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN22-500 |
| Capacity | 22 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 500 W |
| Heating Function | Yes (Adjustable Temperature) |
| Lid with Sound Dampening | Yes |
| Manual Fill/Drain | Yes |
| Construction | Stainless Steel Tank & Housing |
| Control System | Microprocessor-Based Digital Timer & Temperature Controller |
| Timer Range | 1–99 min (Digital Preset) |
| Cumulative Operating Hours Counter | Up to 99,999 h |
| Compliance | Designed for GLP-compliant laboratory environments |
| Instrument Type | General-Purpose Benchtop Ultrasonic Cleaner |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN22-600B |
| Capacity | 22 L |
| Ultrasonic Frequencies | 40 / 59 kHz |
| Ultrasonic Power | 600 W |
| Adjustable Power | No |
| Adjustable Temperature | No |
| Adjustable Timer | Yes |
| Sound-Dampening Lid | Included |
| Drainage | Manual Valve |
| Construction | Stainless Steel Tank & Housing |
| Timer Range | 1–99 min (digital display) |
| Cumulative Operating Hours Counter | Up to 99,999 h |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN22-600C |
| Capacity | 22 L |
| Ultrasonic Frequency | 40 / 59 kHz |
| Ultrasonic Power | 600 W |
| Adjustable Temperature | Yes |
| Adjustable Timer | Yes |
| Sound-Dampening Lid | Included |
| Manual Fill/Drain | Yes |
| Heating Function | Integrated |
| Construction | Stainless Steel Tank and Housing |
| Control System | Microprocessor-Based Digital Interface |
| Timer Range | 1–99 min (digital preset) |
| Cumulative Operating Hours Counter | Up to 99,999 h |
| Compliance | Designed for general laboratory and industrial cleaning applications per ISO 13485-aligned handling practices (non-sterile processing) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN3-120 |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 120 W |
| Adjustable Power | No |
| Adjustable Temperature | No |
| Adjustable Timer | Yes (1–99 min) |
| Sound-Dampening Lid | Included |
| Drainage | Manual valve |
| Construction | Stainless steel tank and housing |
| Timer Display | Digital, with cumulative operating time up to 99,999 hours |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN3-120A |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 120 W |
| Adjustable Power | Yes |
| Adjustable Temperature | Yes (Room Temp to 80 °C) |
| Adjustable Timer | Yes (1–99 min) |
| Sound-Dampening Lid | Included |
| Drain Valve | Manual |
| Construction | Stainless Steel Tank and Housing |
| Dual-Frequency Option | 40/59 kHz (model-dependent) |
| Cumulative Operating Hours Counter | Up to 99,999 h |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN300A |
| Temperature Range | Ambient to 300 °C |
| Temperature Stability | ±0.01 °C (30 min) |
| Bath Volume | 23 L |
| Circulation Type | Internal recirculation |
| Working Medium | Methyl silicone oil |
| Uniformity | ±0.01 °C |
| Power Supply | 220 V / 50 Hz |
| Total Power | 3.0 kW |
| Working Chamber Dimensions | Ø150 mm × 480 mm |
| Recommended Ambient Operating Temperature | <35 °C |
| Brand | Hanuo |
|---|---|
| Model | HN70-2 |
| Temperature Range | Ambient +5°C to 70°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Stability | ≤ ±0.2°C |
| Platform Accuracy | < ±0.3°C (at 37°C) |
| Heating Rate | < 25 min (20°C to 70°C) |
| Timer Range | 0–99 h 59 min |
| Capacity | 2 standard microplates (e.g., 96-well or 384-well ELISA plates) |
| Power Consumption | 150 W |
| Dimensions (W×D×H) | 284 × 264 × 157 mm |
| Origin | Shanghai, China |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HNB80 |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ±0.3°C |
| Heating Time | ≤6 min (20°C → 56°C) |
| Dimensions | 145 × 113 × 110 mm |
| Net Weight | 0.8 kg |
| Power Supply | AC 110–240 V, 50–60 Hz |
| Display Resolution | 0.1°C |
| Timer Range | 1 min – 99 h |
| Module Compatibility | M-A (Φ10 mm, 15 wells), M-B (Φ12 mm, 12 wells), M-C (Φ15 mm, 8 wells), M-D (Φ16 mm, 8 wells), M-E (Φ12 mm conical bottom, 14 wells), M-F (Φ9 mm, 18 wells) |
| Safety | Built-in over-temperature protection, 24 V DC internal power architecture |
| Brand | Hanuo |
|---|---|
| Model | HND-2500 |
| Speed Range | 500–2500 rpm |
| Speed Accuracy | ±50 rpm (at 2500 rpm) |
| Orbit Diameter | 4 mm |
| Max Load Capacity | 5 kg |
| Timer Range | 1 min – 99 h 59 min |
| Display | LED digital speed & time |
| Drive Type | Brushless DC motor |
| Vibration Mode | Horizontal orbital motion |
| Platform Dimensions | 311 × 184 mm |
| Overall Dimensions | 426 × 250 × 480 mm |
| Net Weight | 21.5 kg |
| Power Supply | 100–230 V, 50/60 Hz |
| Power Consumption | 60 W |
| Housing Material | Metal frame with polymer composite panels |
| Standard Accessories | 12 mm foam tube rack, tray pad |
| Optional Racks | Φ10/Φ12/Φ13/Φ16/Φ25/Φ29 mm foam racks (50 or 15 positions), replaceable upper & lower tray pads |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HND-2500 |
| Speed Range | 500–2500 rpm |
| Speed Accuracy | ±50 rpm (at 2500 rpm) |
| Orbit Diameter | 4 mm |
| Timer Range | 1 min – 99 h 59 min |
| Max Load Capacity | 5 kg |
| Top Plate Dimensions | 311 × 184 mm |
| Overall Dimensions | 426 × 250 × 480 mm |
| Net Weight | 21.5 kg |
| Power Supply | 100–230 V, 50/60 Hz |
| Power Consumption | 60 W |
| Display | LED |
| Drive Type | Brushless DC Motor |
| Operating Modes | Continuous & Touch-Start (Momentary) |
| Vibration Pattern | Circular Orbit |
| Amplitude | 4 mm |
| Standard Accessories | 12 mm foam tube rack, tray垫 (upper & lower) |
| Optional Accessories | Foam racks for Φ10/12/13/16/25/29 mm tubes (50-position or 15-position configurations) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HND300-1 |
| Heating Method | Dry Block Heating |
| Temperature Range | Ambient +5°C to 160°C |
| Temperature Stability | ±0.5°C (at 40°C), ±1.0°C (at 120°C) |
| Temperature Uniformity | ±0.5°C |
| Display Resolution | 0.1°C |
| Timer Range | 1–99 h 59 min or continuous |
| Ramp Time | ≤15 min (25°C → 160°C) |
| Vertical Travel | 150 mm |
| Gas Flow Rate | 15 L/min |
| Operating Pressure | 0.05 MPa |
| Sample Capacity | 96 positions |
| Compatible Vessels | 0.2 mL PCR tubes, 96-well flat-bottom microplates |
| Heating Block Material | Aluminum alloy |
| Heating Power | 500 W |
| Dimensions (W×D×H) | 220 × 310 × 385 mm |
| Weight | 7.5 kg |
| Input Voltage | AC 220 V, 50–60 Hz |
| Operating Environment | 5–30°C, RH ≤70% |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HND400 |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 160°C |
| Temperature Stability | ±0.5°C (@40°C), ±1°C (@120°C) |
| Temperature Uniformity | ±0.5°C |
| Display Resolution | 0.1°C |
| Timer Range | 1–99 h 59 min or continuous |
| Ramp Time | ≤15 min (25°C → 160°C) |
| Vertical Travel | 200 mm |
| Gas Flow Rate | 15 L/min |
| Operating Pressure | 0.1 MPa |
| Sample Capacity | 12 positions |
| Heating Power | 500 W |
| Dimensions | 260 × 220 × 475 mm |
| Weight | 7.3 kg |
| Compatible Tube Diameters | 10.5–20.5 mm (interchangeable aluminum blocks) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Distributor |
| Product Origin | Domestic (China) |
| Model | HND400-1 |
| Price Range | USD 420 – 1,400 (FOB) |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 160°C |
| Temperature Stability | ±0.5°C (@40°C), ±1.0°C (@120°C) |
| Tube Diameter Compatibility | 10–29 mm |
| Gas Flow Rate | 15 L/min |
| Sample Positions | 12 |
| Heating Power | 500 W |
| Display Resolution | 0.1°C |
| Timer Range | 1–99 h 59 min or continuous |
| Ramp Time | ≤15 min (25°C → 160°C) |
| Vertical Travel | 200 mm |
| Operating Pressure | 0.1 MPa |
| Dimensions (W×D×H) | 260 × 220 × 475 mm |
| Net Weight | 7.3 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDK200-1 |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Stability | ±0.5°C @ 100°C |
| Temperature Accuracy | ±0.5°C (40–100°C), ±1.0°C (100–150°C) |
| Sample Capacity | 12 positions |
| Tube Diameter Compatibility | 10–19 mm |
| Nitrogen Flow Rate | 0–10 L/min |
| Max. Nitrogen Pressure | ≤0.1 MPa |
| Heating Power | 150 W |
| Display Resolution | 0.1°C |
| Timer Range | 0–99 h 59 min |
| Safety Features | Over-temperature protection, real-time fault detection & audible alarm |
| Gas Distribution | Individual on/off control per channel (12-channel manifold) |
| Adjustable Height | Gas needle and heating block height independently adjustable |
| Standard Needle Length | 150 mm |
| Display Type | LED |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDK200-1 |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Stability | ±0.5°C (at 100°C) |
| Temperature Accuracy | ±0.5°C (40–100°C), ±1.0°C (100–150°C) |
| Sample Capacity | 12 positions |
| Tube Diameter Compatibility | Up to 16 mm |
| Nitrogen Flow Rate | 0–10 L/min |
| Max Operating Pressure | ≤0.1 MPa |
| Heating Power | 150 W |
| Timer Range | 0–99 h 59 min |
| Display | LED, 0.1°C resolution |
| Safety Features | Over-temperature protection, real-time temperature monitoring, automatic fault detection and audible alarm |
| Module Dimensions | 95.5 × 76.5 × 50 mm (standard block) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDK200-1 |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Stability | ±0.5°C (at 100°C) |
| Temperature Accuracy | ±0.5°C (40–100°C), ±1.0°C (100–150°C) |
| Sample Capacity | 12 positions |
| Tube Diameter Compatibility | 12–16 mm |
| Nitrogen Flow Rate | 0–10 L/min |
| Maximum Nitrogen Pressure | ≤0.1 MPa |
| Heating Power | 150 W |
| Warm-up Time | ≤30 min (from 40°C to 150°C) |
| Timer Range | 0–99 h 59 min |
| Display | LED, 0.1°C resolution |
| Safety Features | Over-temperature protection, real-time temperature monitoring, automatic fault detection and audible alarm |
| Construction | Adjustable gas manifold with vertically movable gas needles (standard length: 150 mm), ventilated cabinet-compatible design |
