Common Laboratory Equipment
Filter
Showing 5641–5670 of 17932 results
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLA-2000II |
| Output Flow Rate | 0–2000 mL/min |
| Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Hydrocarbon Content in Output Air | <0.1 ppm |
| Max Input Hydrocarbon Concentration | <100 ppm |
| Operating Temperature | 0–40 °C |
| Operating Humidity | <85% RH |
| Power Consumption | 145 W |
| Dimensions | 450 × 260 × 365 mm |
| Warranty | 12 months |
| Construction | Electropolished stainless-steel tubing, dual-stage filtration, two-stage pressure regulation, auto-drain stainless-steel storage tank |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLH-300II |
| Hydrogen Generation Principle | Alkaline Electrolysis of Deionized Water |
| Output Flow Rate | 0–300 mL/min |
| Output Pressure | 0–0.5 MPa (factory-set at 0.3 MPa) |
| Hydrogen Purity | >99.999% |
| Power Consumption | ≤150 W (220 V ±10%, 50 Hz ±5%) |
| Dimensions | 320 × 180 × 350 mm |
| Weight | 12 kg |
| Operating Environment | 10–40 °C, RH ≤85% |
| Warranty | 1-year full unit, 3-year electrolyzer |
| Brand | Hailong |
|---|---|
| Model | HLHA-300 |
| Hydrogen Purity | 99.999% |
| H₂ Flow Rate | 0–300 mL/min |
| H₂ Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Air Flow Rate | 0–2000 mL/min |
| Air Output Pressure | 0–0.5 MPa |
| Air Hydrocarbon Content | <0.1 ppm |
| Max. Input Air Hydrocarbon Content | <100 ppm |
| Pressure Stability | <0.0001 MPa |
| Max. Power Consumption | 300 W |
| Operating Temperature | 0–40 °C |
| Operating Humidity | <85% RH |
| Warranty | 1-year full unit, 3-year electrolyzer |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLHA-300G, HLHA-500G |
| H₂ Purity | >99.999% |
| Air Quality | Oil-free, Dry, Triple-Filtered |
| H₂ Flow Range | 0–300 mL/min (HLHA-300G) / 0–500 mL/min (HLHA-500G) |
| Air Flow Range | 0–2000 mL/min (HLHA-300G) / 0–5000 mL/min (HLHA-500G) |
| Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa for both gases) |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power | 750 W (HLHA-300G) / 800 W (HLHA-500G) |
| Dimensions (W×D×H) | 300 × 400 × 660 mm |
| Weight | 36 kg |
| Operating Temp. | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Safety | Overpressure protection, alkaline backflow prevention, auto-drain stainless steel air tank |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLHA-300WZ |
| Output Capacity | 300 mL/min H₂ / 300 mL/min Zero Air (typical) |
| Hydrogen Purity | ≥99.999% |
| Zero Air Purity | Hydrocarbon-free (<0.1 ppm THC), CO < 0.1 ppm, CO₂ < 1 ppm, H₂O dew point ≤ −40 °C |
| Operating Pressure | 0–0.4 MPa (adjustable) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions | 360 × 280 × 520 mm |
| Weight | ≤22 kg |
| Auto-refill Reservoir Capacity | 3.5 L |
| Compliance | CE-marked, RoHS-compliant, meets ISO 8573-1 Class 1 compressed air quality for analytical instrumentation |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLHA-500G |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow Rate | 0–500 mL/min |
| Hydrogen Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Air Flow Rate | 0–5000 mL/min |
| Air Output Pressure | 0–0.5 MPa |
| Air Hydrocarbon Content (Output) | <0.1 ppm |
| Air Hydrocarbon Content (Input Tolerance) | <100 ppm |
| Max. Power Consumption | 350 W |
| Pressure Stability | <0.0001 MPa |
| Operating Temperature | 0–40 °C |
| Operating Humidity | <85% RH |
| Warranty | 1-year full unit, 3-year electrolyzer |
| Brand | Hailong |
|---|---|
| Model | HLN-300II |
| Purity | >99.999% |
| Flow Rate | 0–300 mL/min |
| Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power Consumption | 85 W |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 320 × 180 × 350 mm |
| Weight | 12 kg |
| Electrolytic Cell Warranty | 3 years |
| System Warranty | 1 year |
| Brand | Hailong |
|---|---|
| Model | HLN-500II |
| Purity | >99.999% |
| Flow Rate | 0–500 mL/min |
| Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max Power Consumption | 120 W |
| Electrolytic Cell Warranty | 3 years |
| System Warranty | 1 year |
| Origin | Shanghai, China |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLT-300G |
| Nitrogen Purity | >99.999% |
| Hydrogen Purity | >99.999% |
| Air Quality | Oil-free, Dry, Triple-Purified |
| N₂/H₂ Flow Range | 0–300 mL/min |
| Air Flow Range | 0–2000 mL/min |
| H₂ Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| N₂ Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Air Output Pressure | 0–0.4 MPa |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power Consumption | 400 W |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-dust |
| Dimensions (W×D×H) | 460 × 440 × 370 mm |
| Weight | 40 kg |
| Warranty | 1-year system warranty, 3-year electrolyzer warranty |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLT-300II |
| Nitrogen Purity | >99.999% |
| Hydrogen Purity | >99.999% |
| Air Quality | Oil-free, desiccated, triple-purified |
| N₂/H₂ Flow Range | 0–300 mL/min |
| Air Flow Range | 0–2000 mL/min |
| H₂ Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| N₂ Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Air Output Pressure | 0–0.4 MPa |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power Consumption | 400 W |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-dust |
| Dimensions (W×D×H) | 460 × 440 × 370 mm |
| Weight | 40 kg |
| Warranty | 1-year full unit, 3-year electrolytic cell |
| Brand | Hailong |
|---|---|
| Model | HLT-500II |
| Gas Outputs | N₂, H₂, Air |
| N₂ & H₂ Purity | >99.999% |
| Air Quality | Oil-free, Dry, Triple-Purified |
| N₂/H₂ Flow Range | 0–500 mL/min |
| Air Flow Range | 0–5000 mL/min |
| N₂ Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| H₂ Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Air Output Pressure | 0–0.4 MPa |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power Consumption | 500 W |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-dust |
| Warranty | 1-year system warranty |
| Brand | Hailong |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | TD-2000 |
| Primary Desorption Temp Range | 40–380 °C, ±1 °C |
| Valve Heating Range | 40–240 °C, ±1 °C |
| Transfer Line Temp Range | 40–220 °C, ±1 °C |
| Cryo-Focusing Trap Temp Range | −35 to 400 °C |
| Flash Desorption Ramp Rate | >3000 °C/min |
| Peak Width (FWHM) | <3 s |
| Sample Tube ID | ≤6.5 mm |
| Primary Desorption Time | 0–60 min |
| Injection Time | 0–10 min |
| Simulated Sampling Duration | 0–60 min |
| Simulated Sampling Flow Rate | 16–160 mL/min |
| RSD | ≤2.5% (benzene in 0.05 µg methanol standard) |
| Power Consumption | 500 W |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Valve Actuation | Motor-Driven 6-Port Rotary Valve |
| System Architecture | Integrated Benchtop Unit with Embedded Microcontroller and Full-Text LCD Interface |
| Brand | Hailong |
|---|---|
| Model | TD-380 |
| Thermal Desorption Temperature Range | Ambient to 380 °C |
| Valve Oven Temperature Range | Ambient to 150 °C |
| Transfer Line Temperature Range | Ambient to 150 °C |
| Desorption Time | 0–60 min |
| Bake-out (Conditioning) Time | 0–60 min |
| Sample Introduction Time | 0–10 min |
| Carrier Gas Control | High-precision pressure-regulated stainless steel pneumatic system |
| Construction | Passivated 316 SS tubing, PTFE-sealed high-temp valve manifold, silicone O-rings (low-volatility), de-activated inert transfer lines |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | L10060 |
| Pricing | Available Upon Request |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | easyBlood STARline |
| Plate Capacity | 25–55 SLAS/ANSI-compliant deck positions |
| Pipetting Accuracy | ±1–8% CV (volume-dependent) |
| Pipetting Range | 1–1000 µL |
| Sample Throughput | Up to 192 samples per run |
| Dimensions (W × D × H) | 1664 × 795 × 903 mm |
| Brand | HAMILTON |
|---|---|
| Origin | USA |
| Model | MicroLab 600 |
| Instrument Type | Dual-Channel Motorized Liquid Handler |
| Channels | 2 |
| Maximum Syringe Volume | 100 mL |
| Minimum Dispense Volume | 100 nL |
| Accuracy | ±0.1% |
| Operating Principle | Positive-Displacement Syringe Pump Technology |
| Fluid Compatibility | Broad chemical resistance (including concentrated acids, bases, and organic solvents) |
| Residual Volume | <1 µL per cycle |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation |
| Brand | Hamilton |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Microlab NIMBUS 4 |
| Deck Positions | 11 |
| Pipetting Accuracy | ±5% |
| Pipetting Range | 0.5–1000 µL |
| Throughput Configuration | 4-channel independent pipetting |
| Dimensions (W×D×H) | 1041 × 749 × 876 mm |
| Brand | Hamilton |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Microlab PREP |
| Plate Positions | 8 ANSI/SLAS-compliant deck positions |
| Pipetting Accuracy | ±5% |
| Pipetting Range | 0.5–1000 µL |
| Throughput Configuration | 2 independent single-channel + 8-channel pipetting head (configurable) |
| Dimensions (W × D × H) | 533.4 × 609.6 × 609.6 mm |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Microlab STAR |
| Plate Capacity | 25–55 SLAS/ANSI-compliant deck positions |
| Pipetting Accuracy | ±1% to ±8% (volume-dependent, per ISO 8655-6) |
| Pipetting Range | 1–1000 µL |
| Sample Throughput | Up to 384 samples per run |
| Dimensions (W × D × H) | 1664 × 795 × 903 mm |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Hamilton ML STAR V |
| Deck Capacity | 35 or 60 positions |
| Pipetting Accuracy | ±1–8% CV |
| Pipetting Range | 0.35–5000 µL |
| Sample Throughput | Up to 384 samples per run |
| Dimensions (W×D×H) | 1010 × 2000 × 1000 mm |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Manufacturer | Hamilton Company |
| Product Type | Imported |
| Model | Microlab VANTAGE |
| Deck Capacity | >60 SBS-standard plates |
| Pipetting Accuracy | ±1% to ±8% (volume-dependent) |
| Pipetting Range | 0.35–5000 µL |
| Throughput | Up to 384 samples per run |
| Dimensions | 2000 mm × 930 mm × 960 mm |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Hamilton ML Nimbus Presto |
| Plate Positions | 11 |
| Pipetting Accuracy | ±5% |
| Pipetting Range | 0.5–1000 µL |
| Throughput Configuration | 4-channel |
| Instrument Dimensions (W × D × H) | 1041 × 749 × 876 mm |
| Brand | HAMILTON |
|---|---|
| Origin | Switzerland |
| Model | PSD Series |
| Power Supply | 24 VDC, ≤1 A |
| Syringe Compatibility | Hamilton gas-tight glass/PTFE/CTFE/UHMWPE syringes (25 µL to 25 mL) |
| Operating Temperature | 15–25 °C |
| Operating Humidity | 20–90% RH (non-condensing) |
| Communication Interface | RS-232 (1200–9600 baud), TTL I/O (6 in / 6 out) |
| Daisy Chain Capacity | Up to 16 modules |
| Accuracy | ±1.0% full scale |
| Dispense Time per Syringe | 2–60 seconds |
| Memory Storage | 8 user-defined methods (2 KB) |
| Brand | Hamilton |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | PSD/3 |
| Power Supply | 24 VDC (±5%), 1 A typical / 2 A peak |
| Syringe Compatibility | Hamilton GASTIGHT® Half-Height Instrument Syringes (12.5 µL – 12.5 mL) |
| Fluid Contact Materials | Glass, PTFE, CTFE |
| Drive Mechanism | Closed-loop DC servo motor with self-lubricating wear-compensating lead screw |
| Stroke | 30 mm |
| Stroke Time Range | 0.5 s – 60 min (system-configurable) |
| Resolution | Up to 30,000 increments per full stroke |
| Accuracy | ±1.0% at >30% stroke, ±1.2% at 5% stroke (syringe-dependent) |
| Precision | ±0.2% at >30% stroke, ±0.5% at 5% stroke (syringe-dependent) |
| Valve Type | Hamilton HV plug valve |
| Port Sizes | 1.0 mm, 1.5 mm, or 1.8 mm ID |
| Valve Positions | 2-position standard (90°), configurable up to 24 positions (15° increments) |
| Valve Fluid Path | PTFE & CTFE |
| Fittings | 1/4"-28 male tube fittings with flared FEP or PTFE tubing |
| Valve Actuation Time | 390 ms per 90° rotation |
| Operating Temp | 15–35°C |
| Operating Humidity | 20–90% RH (non-condensing) |
| Storage Temp | −20–70°C |
| Storage Humidity | 20–95% RH |
| Communication | RS-232C, 9600 baud, Hamilton Reno Protocol 1 or Bonaduz DIN Protocol |
| Daisy Chain Capacity | Up to 16 modules |
| Onboard Memory | FLASH storage for user methods |
| I/O | 1 TTL I/O port, 1 auxiliary input (e.g., hand probe) |
| Programmable Parameters | Position, speed, prime speed, backlash compensation, on-the-fly speed change, delay timing, valve position/speed |
| Firmware | In-system programmable FLASH |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2mag bioREACTOR 48 |
| Plate Positions | 25–45 |
| Liquid Handling Precision | ±1% CV |
| Liquid Handling Range | 1–5000 µL |
| Sample Throughput | 96 samples per run |
| Dimensions (W×D×H) | 1664 × 781 × 903 mm |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 100 |
| Price Range | USD 112,000 – 140,000 (FOB Jiangsu) |
| Temperature Range | 10–40 °C |
| Reaction Units | 1 |
| Synthesis Scale | 50 μmol – 9 mmol |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Handheld Digital Thermometer |
| Price | Upon Request |
| Temperature Range (°C) | −20 to +120 °C |
| Temperature Range (°F) | −58 to +302 °F |
| Accuracy (°C) | ±0.3 °C (−20 to +90 °C), ±0.5 °C (outside range) |
| Accuracy (°F) | ±0.5 °F (−4 to +194 °F), ±1.0 °F (outside range) |
| Response Time | ≤20 s |
| Power Supply | 1 × 1.4 V battery (3000-hour typical lifespan) |
| Brand | TOYO Corporation |
|---|---|
| Origin | Japan |
| Model | NOGAMI |
| Cutting Thickness Range | 5 µm to 300 µm |
| Feed Mechanism | Manual |
| Maximum Sample Dimensions | Circular apertures Ø1 mm to Ø26 mm |
| Blade Clearance | Adjustable per material and thickness |
| Verticality Control | ≤ 5 µm deviation over 10 mm |
| Upper Blade Tolerance | ±2 µm, ±3 µm, or ±4 µm (specifiable in 1 µm increments) |
| Compatible Materials | Al, Cu, PP/PE separators, SUS304/SUS316, Ni, Ti, Li metal, solid electrolytes, anode composites (e.g., graphite on 10 µm Cu foil, total thickness 175 µm) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Volume Range | 1.0 µL to 50 mL |
| Pricing | Upon Request |
| Brand | Hanil |
|---|---|
| Origin | South Korea |
| Model | CleanVac 12 |
| Maximum Sample Capacity | 12 L |
| Chamber Dimensions | Ø310 × 300 mm (D × H) |
| Condenser Temperature | ≤ –85 °C |
| Vacuum Range | 5 × 10⁻³ to 760 torr (Pirani gauge, semi-log scale, resolution: 0.5 per decade) |
| Compressor | Dual 0.75 HP units |
| Power Supply | 220 V, 60 Hz, single-phase, 1.5 kW |
| Temperature Sensor | Pt100, range –85 to +40 °C, resolution 1 °C |
| Overall Dimensions | 740 W × 600 D × 965 H mm |
| Weight | Approx. 125 kg |